ADB.3... DIRECTIONAL CONTROL

Size: px
Start display at page:

Download "ADB.3... DIRECTIONAL CONTROL"

Transcription

1 SOLENOID VALVES Global solution and hydraulic components DIRECTIONAL CONTROL ADB... DIRECTIONAL CONTROL SOLENOID VALVES CETOP ADB..E...BR.2 (PLASTIC COIL VARIANT) 2100 Reggio Emilia (Italy) 1, Via Natta 1 (Z.I. Mancasale) Phone (+9) Fax. (+9) Web site: sales.ind@brevinifluidpower.com uff.tecnico@aron.it

2 ADB..E... DIRECTIONAL CONTROL VALVES CETOP ADB..E...BR.2 (PLASTIC COIL VARIANT) ADB..E... PRESSURE DROPS PAGE STANDARD SPOOLS PAGE LIMITS OF USE PAGE OVERALL DIMENSIONS PAGE A1 DC COIL PAGE BR DC PLASTIC COIL VARIANT PAGE B1 AC SOLENOID PAGE 6 STANDARD CONNECTORS PAGE 6 The ARON directional control valves NG6 has been designed for subplate mounting with an interface in accordance with UNI ISO standard (ex CETOP R.2--0). The use of solenoids with wet armatures allows a very practical, safe construction completely dispensing with dynamic seals; the solenoid tube is screwed directly onto the valve chest whilst the coil is kept in position by means of a lock nut. Max. pressure ports P/A/B 0 bar Max. pressure port T (DC voltage) 160 bar Max. pressure port T (AC voltage) 100 bar Max flow 60 l/min Max excitation frequency z Fluid viscosity mm 2 /s Fluid temperature -2 C 7 C Ambient temperature -2 C 60 C Max contamination level class 10 in accordance with NAS 168 with filter ß 2 7 Weight with one DC solenoid 1,6 Kg Weight with two DC solenoids 2,02 Kg Weight with one DC plastic coil 1, Kg The operation of the directional valves is in electrical way. The centre position is obtained by means of calibrated length springs which reposition the spool in the centre or end of travel position once the action of the impulse is over. Weight with two DC plastic coils Weight with one AC solenoid Weight with two AC solenoids 1,88 Kg 1,1 Kg 1,72 Kg The solenoids are constructed with a protection class of IP6 to DIN 000 standards and are available in either AC or DC form in different voltage and frequencies. The solenoid coils are normally arranged for DIN 60 ISO 00 type connectors. The valves are designed for use with DIN 12 standard hydraulic mineral oils and it is recommended that filters should be fitted to ensure a maximum contamination level of class 10 in accordance with NAS 168, ß 2 7. Into restrict outside ambient operating conditions, the plastic coils "BR" type variants are suggested. CODICE DI ORDINAZIONE ADB Directional valve CETOP /NG6 E Electrical operator ** Spool (see tables next page) * Mounting (table 1) * Voltage (table 2) ** Variants: 00 = No variants S1 = Solenoid without connectors BR = DC plastc coil (for No. 01/02/0/0/1/16 spools only) * Serial No.: 1 = for AC voltage (B1 coil) 2 = for DC voltage (A1 coil) C E F TAB.1 - MOUNTING TAB.2 - COILS DC VOLTAGE L 12V M 2V AC VOLTAGE A 2V/0z C 110V/0z 110V/60z D 220V/0z O 220V/60z I 2

3 ADB..E... DIRECTIONAL CONTROL VALVES CETOP PRESSURE DROPS Δp (bar) The diagram at the side shows the pressure drop curves for spools during normal usage. The fluid used is a mineral oil with a viscosity of 6 mm 2 /s at 0 C ; the tests have been carried out at a fluid temperature of 0 C. For higher flow rates than those in the diagram, the losses will be those expressed by the following formula: Δp1 = Δp x (Q1/Q) 2 where Δp will be the value for the losses for a specific flow rate Q which can be obtained from the diagram, Δp1 will be the value of the losses for the flow rate Q1 that is used. Spool Connections type P A P B A T B T P T Curve No. STANDARD SPOOL TWO SOLENOIDS, SPRING CENTRED "C" MOUNTING Spool Covering Transient position type * - 22* + 11* + 1* - 28* - ONE SOLENOID, SIDE A "E" MOUNTING Spool Covering Transient position type * * - 28* - ONE SOLENOID, SIDE B "F" MOUNTING The tests have been carried out with solenoids at operating temperature and a voltage 10% less than rated voltage with a fluid temperature of 0 C. The fluid used was a mineral oil with a viscosity of 6 mm 2 /s at 0 C. The values in the diagram refers to tests carried out with the oil flow in two directions simultaneously T = 2 bar (e.g.. from P to A and the same time B to T). In the case where valves /2 and / were used with the flow in one direction only, the limits of use could have variations which may even be negative. Rest times: the values are indicative and depend on following parameters: hydraulic circuit, fluid used and variations in hydraulic scales (pressure P, flow Q, temperature T). Direct current: Energizing 0 0 ms. De-energizing ms. Alternating current: Energizing 10 1 ms. De-energizing 1 2 ms. Spool Covering Transient position type * * - 28* - * PRICE INCREASING I

4 ADB..E... DIRECTIONAL CONTROL VALVES CETOP LIMITS OF USE DC STANDARD SOLENOIDS BR PLASTIC COIL VARIANT Spool DC Solenoids type Standard Var. BR Curve AC STANDARD SOLENOIDS AC VOLTAGE 220V/60Z ONLY Spool AC Solenoids type Standard 220V/60z Curve For AC voltage at 220V/60z see special diagram. OVERALL DIMENSIONS BR variant (DC Plastic coil) AC Coil E = Manual override Fixing screws UNI 91 Mx0 with material specification min. 8.8 Tightening torque 6 Nm / Kgm Support plane specifications I

5 "A1" DC COILS Type of protection IP 6 Number of cycle Supply tolerance ±10% Ambient temperature -0 C 60 C Insulation class Weight (coil) 0, Kg Weight (solenoid) 0,26 Kg Rated power 0W Max. winding temperature (Ambient temperature at 20 C) 110 C Resistance at 20 C for 12 voltage coil.8 Ohm (±10%) Resistance at 20 C for 2 voltage coil 19.2 Ohm (±10%) ETA1-02/200/e GRAY (A) BLACK (B) V V Q28002 Nut M70008 for tub code M80001 (lenght 8, mm). Q286006C Q Tub M8001 (lenght 8, mm) for nut code M V 2V M M ETA1-CODE - 02/2007/e "A1" DC COILS "BR" PLASTIC VARIANT Type of protection IP 6 Number of cycle Supply tolerance ±10% Ambient temperature - C 60 C Insulation class Weight (coil) 0,08 Kg Weight (solenoid) 0,27 Kg Rated power W Max. winding temperature (Ambient temperature at 20 C) 110 C Resistance at 20 C for 12 voltage coil. Ohm (±10%) Resistance at 20 C for 2 voltage coil 17. Ohm (±10%) ETA1BR - 02/2007/e GRAY (A) BLACK (B) V V ATTENTION! MOUNTING 2 O RING BETWEEN COIL AND NUT Q Nut M70008 for tub code M80001 (lenght 8, mm). Q Q Q28002 Tub M8001 (lenght 8, mm) for nut code M V 2V M M ETA1BR-CODE - 02/2007/e I

6 "B1" AC COILS, 80, Type of protection IP 6 Number of cycle Supply tolerance ±10% Ambient temperature -0 C 60 C Insulation class Weight (coil) 0,290 Kg Weight (solenoid) 0,6 Kg VOLTAGE MAX. WINDING TEMPERATURE RESISTANCE AT 20 C (V) (AMBIENT TEMPERATURE 2 C) (OM) ± 10% 2V/0z 120 C V/0z 11 C V/60z V/0z 91 C V/60z 98 C 86.8 ETB1-01/200/e GRAY (A) BLACK (B) V V M Q28002 Q286006C M70001 M V/0Z M V/0Z M V/60Z M V/0Z M V/60Z M16000 ETB1-CODE - CONNECTORS DIRECTIONAL CONTROL VALVES IN ACCORDANCE WIT DIN 60 / ISO 00 CONNECTOR ORDERING CODE CODE STANDARD (IP6) Grey (side A) V No variant Black (side B) V No variant ETCNTADB - 00/200/e Incorrect use of the products described in this catalogue may cause harm to personnel and equipment. The technical information given for each product in this catalogue may be subject to variation, and the manufacturer reserves the right to make constructional modifications without giving prior notice. Each product presented, its data, features and technical specifications must therefore be examined and checked by members of the user's staff (possessing suitable technical knowledge) taking into consideration the intended use of product. The user must, in particular, assess the operating conditions of each product in relation to the application that he intends to use it for, analysing the data, features and technical specifications in view of the proposed applications, and ensuring that, in use in the product, all of the conditions relating to the safety of personnel andequipment, also in the event of breakdown, are respected. I 6

7 80,8 "B1" AC SOLENOIDS FOR CETOP Type of protection (in relation to the connector used) IP 6 Number of cycles Supply tolerance +10% / -10% Ambient temperature -0 C 60 C Insulation class wire Weight 0,6 Kg MOUNTING COMPATIBILITY CETOP * C. I PAGE 8 AD.E... * C. I PAGE 11 (*) serial No. (AC voltage) ES MANUAL EMERGENCY P2 ROTARY EMERGENCY 81,1 8, 112 VOLTAGE MAX. WINDING TEMPERATURE RESISTANCE AT 20 C RATED POWER PICKUP CURRENT (V) (AMBIENT TEMPERATURE 2 C) (OM) ±10% (VA) (A) 2V/0z - 2V/60z 100 C - 96 C V/0z - 8V/60z 112 C - 98C V/0z - 120V/60z 1 C - 101C V/0z - 20V/60z 120 C - 10C SPARE PARTS B A B1 AC COIL VOLTAGE CONNECTION IRSCMANN (STANDARD) C E F 2V/0-60Z (A) 8V/0-60Z (B) 11V/0Z (J) 120V/60Z 20V/0Z (Y) 20V/60Z M16000 M M M D B = SEE B1 COIL TABLE A / C / D / E / F = SINGLE SPARE PARTS (SEE CODES TABLE) COMPLETE KIT TUBE KIT ROTARY EMERGENCY P2 MANUAL EMERGENCY ES CODE V V M CODE A B C D E F MOUNTING SPARE PARTS O RING COIL O RING RING NUT TUBE EX. PUSROD AVAILABLE ADE* Q28002 Q M70001 M M C - E - F - M M G - - I - L M72000 D SEE B1 (*) serial No. (AC voltage) File: TCOILCODE_E XII 6 08/2011/e

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

DIRECTIONAL CONTROL VALVES CETOP 3/NG6 CETOP 3/NG06 STANDARD SPOOLS CH. I PAGE 0 AD.3.E... CH. I PAGE AD.3.E...J* CH. I PAGE 2 AD3.XS... CH. I PAGE 3 AD3.XD... CH. I PAGE 4 AD.3.V... CH. I PAGE 5 AD.3.L... CH. I PAGE 6 OTHER OPERATOR CH. I

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

DIRECTIONAL CONTROL VALVES CETOP 5/NG10

DIRECTIONAL CONTROL VALVES CETOP 5/NG10 INTRODUCTION The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CTOP R 35 H 4.2-4-05), and can be used in

More information

DIRECTIONAL CONTROL VALVES CETOP 5/NG10

DIRECTIONAL CONTROL VALVES CETOP 5/NG10 CETOP 5/NG0 STANDARD SPOOLS CH. I PAGE 30 AD.5.E... CH. I PAGE 3 AD.5.E...J* CH. I PAGE 32 AD.5.E...Q5 CH. I PAGE 32 AD.5.O... CH. I PAGE 33 AD.5.D... CH. I PAGE 33 AD.5.L... CH. I PAGE 34 A6 DC SOLENOID

More information

ADH /3 AND 4/2

ADH /3 AND 4/2 ADH.7... STANDARD SPOOLS FOR ADH.7 CH. I PAGE 53 TECH. SPECIFICATIONS ADH.7... CH. I PAGE 54 SUBPLATES.7... CH. I PAGE 55/56 CETOP 3/NG06 CH. I PAGE 8 STANDARD SPOOLS FOR AD.3.E CH. I PAGE 0 AD.3.E...

More information

ADH /3 AND 4/2

ADH /3 AND 4/2 ADH.7... STANDARD SPOOLS FOR ADH.7 CH. I PAGE 53 ADH.7... CH. I PAGE 54.7... CH. I PAGE 55/56 CETOP 3/NG06 CH. I PAGE 8 STANDARD SPOOLS FOR AD.3.E CH. I PAGE 0 AD.3.E... CH. I PAGE ADC.3... CH. I PAGE

More information

V*L Pressure control valves in line

V*L Pressure control valves in line V*P / V*L... V*P... cap. II 7 V*PE... cap. II 8 V*L... cap. II 9 - Cap. II 10 BSVMP... cap. II 11 KEC16/5... cap. II 9 C*P16/5... cap. II 9 CETOP 3/NG06 cap. II 8 Standard spools for AD3E Cap. II 10 AD3E...

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

TECHNICAL CATALOGUE ARON 2005

TECHNICAL CATALOGUE ARON 2005 AP AS BP H H DA DP TEHNIAL ATALOGUE ARON 2005 ABBREVIATIONS HIGH PRESSURE ONNETION PHASE LAG (DEGREES) LOW PRESSURE ONNETION STROKE (MM) AROSS FLATS INTERNAL AROSS FLATS AMPLITUDE DEAY (DB) DIFFERENTIAL

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P) / - / Proportional directional valves L solenoid (LCP) operated (for open loop control) L (LCP) RE - Edition:. Replaces: 7. 7. Size Series Maximum operating pressure bar ( psi) Maximum flow l/min (.7 gpm)

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

VALVES AND ELECTRONICS. Technical Catalogue

VALVES AND ELECTRONICS. Technical Catalogue VALVES AND ELECTRONICS Technical Catalogue July 202 VALVES AND ELECTRONICS TECHNICAL CATALOGUE 202 CH. I DIRECTIONAL CONTROL Plant Aron: Via Natta, 4224 Reggio Emilia - Italy Tel. +39 0522 5058 Fax +39

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

4/3, 4/2 proportional directional valves solenoid operated (for open loop control) /, / proportional directional valves solenoid operated (for open loop control) RE -/7. Replaces: RE7/.7 / Type L (LCP) Size Series Maximum operating pressure bar [ psi] Nominal flow rated l/min [.7 gpm]

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

CDL STACKABLE CIRCUIT

CDL STACKABLE CIRCUIT CD.04.6... A09 DC COI CH. I PAGE 67 CONNECTORS STANDARD CH. I PAGE 9 CD.04.6... STACKABE CIRCUIT SEECTOR VAVES The stackable circuit selector valves, type CD.04.6, allows one single drive of 5 users with

More information

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000 Solenoid Operated Directional Valves RPE2-04 HA 4012 3/2002 Size 04 p max up to 320 bar Q max up to 20 l/min Replaces HA 4012 6/2000 Special model - special installation dimensions 4/3-, 4/2- and 3/2-way

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters L (VS151-VS152-VS155) 6/2 ways/positions flow diverters L721... (VS151-VS152-VS155) RE 1832-5 Edition: 2.216 Replaces: 5.214 Size 6 Series 1 Maximum operating pressure 31 bar (45 psi) Maximum flow 6 l/min (15.85 gpm) Ports

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 1832-5/12.9 1/8 L721... (VS151-VS152-VS155) Size 6 Series 1 Maximum

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-09/12.09 1/10 L732... (VS241F-VS245F-VS246F-VS247F)

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 18302-07/12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00

More information

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters L (VS120-VS125-VS129) 6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports

More information

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) 10/2010 Replaces 12/2007 4/3-, 4/2- way directional control valves with solenoid control Solenoids

More information

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min 41 330/116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-05 p max 320 bar Q max 125 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-05-04-0-05 (CETOP 4.2-4-05-320)

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters 6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

3/2 ways/positions flow diverters L (VS91-VS92-VS95) 3/2 ways/positions flow diverters L706... (VS91-VS92-VS95) RE 18302-03 Edition: 04.2016 Replaces: 02.2016 Size 12 Series 00 Maximum operating pressure 310 bar (4500 psi) Maximum flow 140 l/min (36.98 gpm)

More information

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10 table HD-0/ (07/0) DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD-ES-*-/0 CETOP 0-5 MPa /5 HOW TO READ THE MODEL CODE FOR HD-ES - Pressure 5 MPa (50 bar) HD - ES - () (C) - * - (0C) (-) / 0 5 6 7

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z) 4/3-4/2 Directional valve elements LF1_1 LC1F-Z) RE 18305-01 Edition: 02.2016 Replaces: 07.12 07.2012 Size 6 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 35 l/min 9.25 gpm) Ports

More information

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Directional Control Valves, electrically operated Type WE 5 Huade América 1 Directional Control Valves, electrically operated Type WE 5 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Directional control valves, electrically operated Type WE 5 Size5 up to 25

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

3/2 ways/positions flow diverters

3/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 3/2 ways/positions flow diverters RE 18302-02/12.09 1/8 L705... (VS81-VS82-VS84-VS85) Size 6 Series 00

More information

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve. AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min Proportional Directional Control Valves Size 06 p max 50 bar Q max 40 L/min PRM-06 HA 5104 /014 Replaces HA 5104 /01 Compact design with integrated High reliability Simple replacement of the exciting coils

More information

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60 41 300/198 ED D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 0 ALTERNATING CURRENT - SERIES 60 CETOP 0 p max 30 bar Q max 100 l/min MOUNTING INTERFACE DIRECT-ACTING SOLENOID OPERATED

More information

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004 Solenoid Operated Directional Control Valves with Wirebox RPEW4-06 2/2005 Size 06 p max up to 320 bar Q max up to 80 L/min Replaces 2/2004 4/3, 4/2 way directional control valves Four-land spool - reduced

More information

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING / and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure

More information

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05

More information

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) RE 18305-03 Edition: 02.2016 Replaces: 07.12 07.2012 Size 10 Series 00 Maximum operating pressure 250 bar (3600 psi) Maximum flow 90

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F)

More information

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING 4/3 and 4/2 Proportional directional valve elements L881 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING L881 (EDC-P1) RE 1831-1 Edition: 6.218 Replaces: 7.12.217 Size 6 Series Maximum

More information

SOLENOID DIRECTIONAL VALVE

SOLENOID DIRECTIONAL VALVE SOLENOID DIRECTIONAL VALVE type DHE direct operated, high performances, ISO 4401 dimensione 06 Spool type, two or three position direct operated valves with high performance threaded solenoids certified

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/07.12 Replaces: 12.09 1/8 L711... (VS120F-VS125F) Size 4 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 20

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/12.09 1/10 L711... (VS120F-VS125F)

More information

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10 41 320/110 ED DS5JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVE ALTERNATING CURRENT NFPA D05 (ISO 4401-05 / CETOP 05) p max 4600 psi Q max 32 GPM MOUNTING INTERFACE NFPA D05 ISO 4401-05-0-04-05 (CETOP

More information

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A) 4/3-4/2 Directional valve elements B8_A with or without (EDB-A) secondary relief valves, with or without LS connections B8_A (EDB-A) RE 183-56 Edition: 11.218 Replaces: 7.12 Size 4 Series Maximum operating

More information

Sepehr Hydraulic Asia

Sepehr Hydraulic Asia Vickers Solenoid Operated Directional Valves Explosion Proof ATEX, UL, CSA Sepehr Hydraulic Asia DG4V-3S, X4 & X5 DG4V4-1, X5 Table of Contents Introduction General Description... 3 Features and Benefits...

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

RSE 4-06 ORDERING CODE. DIRECTIONAL CONTROL VALVES KE qqqq Q(uD4 D n. 06 p max 35 MPa Q max 80 dm 3 /min. Du8

RSE 4-06 ORDERING CODE. DIRECTIONAL CONTROL VALVES KE qqqq Q(uD4 D n. 06 p max 35 MPa Q max 80 dm 3 /min. Du8 DIRECTIONAL CONTROL VALVES KE qqqq Q(uD4 D n 06 p max 35 MPa Q max 80 dm 3 /min Selenoid operated directional control valves of type RSE4)06 are used to control start3 stop and direction of luid in hydraulic

More information

Stand alone 4/3, 4/2 solenoid operated directional valve

Stand alone 4/3, 4/2 solenoid operated directional valve Stand alone 4/3, 4/2 solenoid operated directional valve (LF ) FAN DRIVE (LF ) RE 1835-4 Edition: 2.216 Replaces: 7.12 7.212 LF1 Size 6 LF2 Size 1 Series LF1 Maximum operating pressure 31 (45 ) LF2 Maximum

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/07.12 Replaces: 12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F) Size 10 Series 00 Maximum operating pressure 310 bar [4500

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve RE 183-54/7.12 Replaces: 1.9 1/8 8_58 (EDZ-VEI) Size 4 Series

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ) 4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ) RE 1831-11 Edition: 6.218 Replaces: 7.12 2.216 Size 6 Series Maximum operating pressure

More information

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES 41 230/102 AD MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES ALTERNATING CURRENT NFPA D03 (CETOP 03) p max 5,000 psi Q max 18 GPM MOUNTING INTERFACE OPERATING PRINCIPLE NFPA D03 CETOP 4.2-4-03-350

More information

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4 EV FT3 ES-FT5 ES/GB 4 15-07-2008 16:09 Pagina 4 5 1 HOW TO READ THE MODEL CODE FOR VALVES FT3 - ES - * FT3 - ES - (1) (C) - * - (024C) / 10 2 FUNCTIONAL SYMBOLS 1C 1N 1 2 3 4 5 6 7 1 FT3 4-way directional

More information

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections 4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 183-52/7.12 Replaces: 1.9 1/8 8_8 (EDZ) Size 4 Series Maximum operating pressure 31 bar

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min DIRECTIONAL CONTROL VALVES KE 2053 07/13 D n 06 p max 32 MPa Q max 80 dm 3 /min Manually operated directional control valves of type RSP7 06 operated by hand lever are used to control start, stop and direction

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A600/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par 41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511 ywire Elements Flow Sharing Element Interface IW05 efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES Technical data Nominal flow Nominal pressure 35 l/min - P=8 bar

More information

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data Seated valves Type WV700 Features Direct operated Leakage free (double tight) High operational safety and reliable switching High duty cycles and long lifetime Applications Control of cylinders and motors

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......

More information

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve 01/06 4/3, 4/2 and 3/2 explosion-proof solenoid directional valve Type G...WE10...L3X 2.22 Size (NG) 10 Up to 315 bar Up to 120 L/min Contents Function and configuration Specifications 03 Spool symbols

More information

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012 4/2 and 4/3 Way Directional Control Valves Pilot Operated RNEH4-25 HA 4024 7/2015 Size 25 (D 08) 320 bar (4600 PSI) 600 L/min (159 GPM) Replaces HA 4024 6/2012 Solenoid pilot operated directional valves

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

20 l/min (5 GPM) p max. Technical Features

20 l/min (5 GPM) p max. Technical Features Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional

More information

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

6/2 WAY DIRECTIONAL VALVE KV (NG 6) 6/2 WAY DIRECTIONAL VALVE KV (NG 6) NG 6 Up to 350 bar [5 076 PSI] Up to 50 L/min [13.2 GPM] Plug-in connector for solenoids to ISO 4400. Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas),

More information

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006 Solenoid Operated Directional Control Valves with Wirebox RPEW-10 5/2012 Size 10 (D 05) 350 bar (5076 PSI) 10 L/min (37 GPM ) Replaces 2/2006 /3, /2 way directional control valves Four-land spool - reduced

More information

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41 83 250/198 ED D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP 05 p max 250 bar Q max (see performance ratings table) MOUNTING INTERFACE OPERATING

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25

More information

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10 Table TE030-0/E Solenoid directional valves Pmax 40 bar direct operated, ISO 440 size 06 and size 0 HEP-07*-** HEP; KEP, direct operated solenoid valves with max pressure up to 40 bar for heavy duty applications

More information

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002 4/2 and 4/3 Way Directional Control Valves Pilot Operated RPEH4-16 HA 4023 2/2003 Size 16 p max up to 320 bar Q max up to 300 L/min Replaces HA 4023 2/2002 Solenoid pilot operated directional valves (RPEH)

More information

Solenoid directional valves type DPHI, DPHU

Solenoid directional valves type DPHI, DPHU www.atos.com Table E0805/E Solenoid directional valves type, two stage, ISO 4401 size 10, 16, 25 and 32 37**/HM..... and are spool type, two or three position directional two stage solenoid valves designed

More information

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES

More information

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min 52 000/103 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RA 183-52/1.11 1/1 4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections B8_8 (EDBZ) Summary Description Page General specifications 1 Ordering

More information

Type of operation Depending on requirement either one or two dry DC-solenoid,

Type of operation Depending on requirement either one or two dry DC-solenoid, Features Leakage free High availability 100% duty cycle Porting NG 6 according to DIN 24340 Positive overlap Function and design The seated valves are direct operated. Depending on the desired control

More information

40 l/min (11 GPM) p max

40 l/min (11 GPM) p max Proportional Directional Control Valve, with Analog Control Electronics PRM2-06 Functional Description Size 06 (D03) Q max 40 l/min (11 GPM) p max 350 bar (5100 PSI) Technical Features Direct acting, proportional

More information

2/2-way poppet valves with solenoid operation Type KSDER1

2/2-way poppet valves with solenoid operation Type KSDER1 RE 8 36-0/0.0 Replaces: 07.0 /-way poppet valves with solenoid operation Type KSDER Build size T-3A cavity Maximum operating pressure 350 bar Maximum flow 0 L/min H/A/D 680/0 Type KSDER.A/HC... Overview

More information

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32 www.atos.com Table E0857/E Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32 DPHE471*/H Spool type, two stage directional valves with solenoids certified according

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009 Proportional Directional Control Valves PRM7-6/ Size D () bar (6 PSI) L/min (. GPM ) Replaces /9 Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis