ACROBAT SWING STAND MODEL

Size: px
Start display at page:

Download "ACROBAT SWING STAND MODEL"

Transcription

1 Mounting instructions Directions for use ACROBAT SWING STAND MODEL Stand lamps: Mach Mach 120F... Mach Mach 130F... Mach LED Mach LED 120F... Mach LED Mach LED 130F... Order No Order No Order No Order No Order No Order No Order No Order No GmbH u. Co., Flossmannstrasse 28, D Ebersberg Tel.: +49 (0) , Fax +49 (0) Internet: Edition / Bak Page 1/22

2 List of contents 1. Safety instructions... Page 3 2. Installation summary stand lamps... Page 4 3. Mounting instructions... Page Mounting the stand... Page Mounting the stand foot... Page Mounting the stand tube to the stand foot... Page Mounting the spring arm and the lamp head... Page Mounting the spring arm to the stand tube... Page Mounting the lamp head to the spring arm... Page Installation of the stand... Page Cleaning... Page Maintenance... Page Periodical maintenance work... Page Changing the fuses (Mach 130 and Mach 130F only)... Page Changing the power supply (LED 120 and LED 130 only)... Page Adjusting the spring force... Page Maintenance of the securing segment... Page Data... Page Technical data... Page Environmental conditions... Page Disposal... Page CE- mark... Page Dimensions and range of movement... Page Spare parts... Page Spare parts list... Page 19 Appendix to the mounting instructions (toroidal transformer)... Page Edition / Bak Page 2/22

3 1. Safety instructions The stand foot must not be connected to the mains, until it has been fully assembled and installed. Connect the stand only to a correctly installed socket with earthing contact. The socket used must be installed according to the requirements of IEC and VDE This device is not suitable for use in hazardous locations. The devices are not suitable for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. Repairs to the stand and special installation work on the sliding contacts should only be carried out by ourselves or a company expressly authorised by ourselves. The manufacturer is only responsible for operational safety of the stand foot when repairs and modifications are carried out by his own staff or by persons who guarantee compliance with the safety regulations. The manufacturer is not responsible for damage to persons or property caused by incorrect or improper use, or when used for incorrect purposes. General information These installation instructions must be kept at hand together with the relevant operating instructions for consultation at any time. The stand is designed for carrying and positioning of medical examination lamps up to a max. weight of 3kg and to supply the lamps with electricity. The stand is available: with built-in transformer 22,8V sec.; 50/60Hz without transformer 230V; 50/60Hz The output voltage of the transformer is not adjustable. The device is designed for continuous operation. Make sure, that the maximum load does not exceed 3kg. Please read these mounting instructions and directions for use carefully before working with the device. In this way you will profit from all advantages of the device and save yourself and other persons from harm Edition / Bak Page 3/22

4 2. Installation summary stand lamps Type 1: Mach 120; Mach 120F Type 2: Mach 130; Mach 130F 1 Stand type 1 has a built-in transformer 230V / 22,8V 90W and is delivered in combination with the lamp Mach 120/120F. The transformer is positioned in the transformer housing 1 on the stand base. Stand type 2 has no built-in transformer, it is delivered in combination with the lamp Mach 130/130F. The transformer is positioned in the lamp head Edition / Bak Page 4/22

5 3. Mounting instructions 3.1 Mounting the stand 1 Extent of supply for stand foot: 1 stand foot 1 stand tube 1 spring arm 2 3 Mounting accessories: 2 antistatic rollers with brakes 2 rollers without brakes 1 colour foil 2 plastic half-rings 1 plastic bushing 1 security segment 1 washer 1 retaining ring 1 pliers for retaining ring Mounting the stand foot To mount the stand foot proceed as follows: Guide the two antistatic rollers 1 with brakes through the ring terminal of the potential compensation line 2 and insert the two rollers completely into the stand foot 3. Insert the rollers without brakes completely into the stand foot. Check if the rollers are firmly fixed. Pull off the adhesive foil 4, lay colour foil into the eye-shaped depression of the stand foot and press evenly to surface. Pull off protective foil Edition / Bak Page 5/22

6 3.1.2 Mounting the stand tube to the stand foot 2 3 Nase For mounting the stand tube proceed as follows: Mach 120 / Mach 120F Loosen winged screw (with lock washer) 1 at stand tube 2 and remove. Insert stand tube 2 in such a way, that the recess of tube 3 fits into the nose of stand foot 4 and tube 3 can no more be rotated. Check if the stand tube is firmly fixed. Insert winged screw (with lock washer) 1 and tighten. Caution: If the nose of the stand does not snap in and the stand tube is not fixed by the winged screw and lock washer, it is possible, that the stand tilts Nase 4 6 Mach 130 / Mach 130F The stands for Mach 130 and Mach 130F are equipped with an additional weight 5 on their bottom side. Loosen screw (with lock washer) 6 at stand tube 2 and remove. Insert stand tube 2 in such a way, that the recess of tube 3 fits into the nose of stand foot 4 and tube 3 can no more be rotated. Check if the stand tube is firmly fixed. Insert screw (with lock washer) 1 and tighten. Caution: If the stand has not be fixed properly as described above, it will tip over. 8 Nur Mach Mach 130 only Press the plastic semi-rings 7 into the stand foot 4. Screw in recessed head screws 8 and check if the semi-rings are firmly fixed Edition / Bak Page 6/22

7 3.2 Mounting the spring arm and the lamp head Mounting the spring arm to the stand tube For mounting the spring arm proceed as follows: Unscrew recessed head screw 1, pull off cover cap 2 and remove it by pulling it upward. Insert spring arm journal, place washer 4 and secure the spring arm with retaining ring 5. Check if the retaining ring 5 is firmly fixed. Caution: If not handled properly the retaining ring 5 gets loose and the spring arm falls off the connection. Always mount washer 4. Close electrical connection 6. Replace cover cap 2 and fix it with recessed head screw Edition / Bak Page 7/22

8 3.2.2 Mounting the lamp head to the spring arm ATTENTION! Notice the rated voltage information! Coupling journal Lamp bow Sticker with voltage information Each lamp has a red sticker applied near the coupling journal at the lamp bow. The sticker shows the rated voltage of the lamp. Connect the lamp only to the prescribed voltage, to avoid irreparable damage (e.g. the electrical components). Following rated voltage is usual: 22,8 V 230 V 120 V 110 V 24-28V DC After mounting the lamp take off the sticker and dispose it, otherwise it could fall down in the OT-field after some time! Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm. Note: Maximum permissible load of spring arm: 3kg! Edition / Bak Page 8/22

9 Do not remove screw 13, it is designed to fix the sliding contact and provides earthling! Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm. Mounting the lamp Mach 120/120F to the spring arm Loosen brake screw 1, so the plastic bushing 2 can be slipped easy onto the spring arm. Slip plastic bushing 2 onto the spring arm to overlap slots 3. Check if the journal 4 of the lamp is greased. Insert the greased journal 4 of the lamp and insert security segment 5 completely into slot 3, so that the security segment leads in groove 6. Rotate plastic bushing 2 by 180 up to the provided drilling for the brake screw and screw in brake screw 1 until you reach the desired brake effect for lamp head 4. Check if lamp head 4 is firmly fixed Mounting the lamp Mach 130/130F to the spring arm Loosen brake screw 12, so the plastic bushing 7 can be slipped easy onto the spring arm. Slip plastic bushing 7 onto the spring arm to overlap slots 8. Check if the journal 9 of the lamp is greased. Insert the greased journal 9 of the lamp and insert security segment 10 completely into slot 8, that the security segment leads in groove 11. Rotate plastic bushing 7 by 180 up to the provided drilling for the brake screw and screw in brake screw 12 until you reach the desired brake effect for lamp head 9. Check if lamp head 9 is firmly fixed Edition / Bak Page 9/22

10 3.3 Installation of the stand 1. Take the stand to the working place and arrest the two rollers with brakes. Caution: Do not touch damaged electrical parts. Danger of electrical shock! If you notice a damaged mains cable or plug do not plug in. Call your service number and report the damage. 2. Check if mains plug or mains cable are damaged. 3. Please check that an earthed socket is available within the working area of the lamp. The socket to be used for the lamp must be installed according to the requirements stipulated by the IEC or VDE Remark: Do not overrun any objects on the floor or the mains cable. The stand might tip over. 4. Cleaning Note: Before doing any cleaning work turn off the lamp, draw plug from mains and make sure that the lamp cannot be switched on again. Please ensure, that no disinfection liquid flows into the joints or lamp head. The surface of the stand can be easily kept clean by simply wiping with a wet cloth. You can use conventional cleaning agents. Caution: In order to prevent any damage at plastic parts do not use scouring agents or alkaline, acidic and alcoholic cleaning agents. For cleaning proceed as follows: Draw plug from mains. Wipe the surface of the stand with a wet cloth. As a cleaning agent you can use water or a soap solution (washing-up liquid). 5. Maintenance Note: Before doing any maintenance work, turn off the lamp, draw plug from mains and make sure, that the lamp cannot be switched on again. 5.1 Periodical maintenance work The following maintenance work / tests has / have to be done every six months: check on defects in paint work; check on fissures at plastic parts; check on deformation of the suspension. The following maintenance work / tests has / have to be done once a year: check the function; electrical safety test; check the suspension; Edition / Bak Page 10/22

11 Remark: Check the fixing screw at the lower part of the stand once a year and, if necessary, adjust. Check and grease the security segment once a year. 5.2 Changing the fuses (Mach 130 and Mach 130F only) 1 The fuses are positioned inside the handle of the stand. Unplug from mains. Open the handle 1 of the stand by loosening the two fixing screws (suitable tools: slotted screwdriver 2,5x75 or screwdriver TORX TX9). 2 Remove the two fuse holders 2 and Remove the two fuses from the fuse holders 2 and 3, exchange the fuses and mount the fuse holders into the handle of the stand. Visible fuse 5x20 / 10AT / 250V A X Place cap A into the handle half. Mount the handle 1 with the two fixing screws. Attention: While mounting the handle make sure not do damage the coating of the power cord in the shown position X Edition / Bak Page 11/22

12 5.3 Exchanging the power supply (Mach LED 120 and LED 130 only) In case of the mobile lights LED 120 and LED 130 the power supply is located inside the handle of the mobile stand. For exchanging the power supply proceed as follows: Disconnect the light from mains. Loosen the two fixing screws of the mobile stand handle (required tool: cross-head screw-driver). Fold the handle apart. Disconnect the power supply cables from the electrical terminals. Loosen the two fixing screws of the power supply. Remove the power supply. Mount the new power supply in reverse order and connect the cables. Check the function of the light Edition / Bak Page 12/22

13 5.4 Adjusting the spring force Springs are wearing parts, thus the spring force can decrease in time and must be readjusted. Note: Set the spring force in such a way, that the spring arm with the lamp head holds its position at every set height. B A In case the spring arm with the lamp moves down on its own, proceed as follows: Remove lateral cover A. The adjusting screw (B) for the spring force is visible now. Push the lamp and spring arm upwards as much as possible, so the spring is without charge. Insert a slotted screwdriver into the screw B. Turn the adjusting screw to the left (anticlockwise), until the lamp holds its position at every set height. B In case the spring arm with the lamp moves up on its own, proceed as follows: Remove lateral cover A. The adjusting screw (B) for the spring force is visible now. Push the lamp and spring arm upwards as much as possible, so the spring is without charge. Insert a slotted screwdriver into the screw B. Turn the adjusting screw to the right (clockwise), until the lamp holds its position at every set height. 5.5 Maintenance of the securing segment Dismount the lamp head in reverse order of mounting (see chapter 3.2.2). Check the thickness of the segment. It must be at least 1,5mm. In case the thickness of the segment is less than 1,5mm it has to be changed. Grease the segment and the coupling journal of the lamp. Mount the lamp to the spring arm, as described in chapter Edition / Bak Page 13/22

14 6. Data Mobile stand for Mach 120 Electrical data Rated voltage depending on design Maximum power consumption depending on design Rated frequency 100 V / 120 V / 230 V 40 W / 90 W 50 / 60 Hz Fuses 5 x 20 mm, delay T Rated voltage, primary Rated power consumption-transformer Rated current of the fuses 120 V 60 VA (electronic) 1,0 A 230 V 60 VA (electronic) 0,5 A 100 V bis 127 V 60 VA (electronic) 1,25 A 213 V bis 247 V 60 VA (electronic) 0,63 A 120 V 90 VA (thoroidal) 1,6 A 230V 90 VA (thoroidal) 0,8 A Mobile stand LED 120 LED 130 Mach 120 Mach 130 Rated voltage 230V 230V 230V 230V Rated frequency 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz Power consumption 18W 28W 50W 50W Rated current at 24V 0,64A 1,00A 2,1A 2,1A Protection class I. I. I. I. The device is not suitable for use in combustible blends of anaesthesia agents with air or for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. The device is designed for continuous operation Edition / Bak Page 14/22

15 6.2 Environmental conditions Operation Min. Max. Temperature +10 C +40 C Relative athmospheric humidity 30% 75% Air pressure 700hPa 1060hPa Transport / storage Min. Max. Temperature +10 C +40 C Relative athmospheric humidity 30% 75% Air pressure 700hPa 1060hPa 7. Disposal The stands do not contain any danger goods. The components of the stand should be properly disposed at the end of its shelf life. In order to respect all regulations for disposal, please contact us before disposing the product. 8. CE- mark The stands comply to the standards 93/42/EEC for medical products of the European Community s Council Edition / Bak Page 15/22

16 9. Dimensions and range of movement Edition / Bak Page 16/22

17 10. Spare parts , , Mach Mach ,20,32 09, , Edition / Bak Page 17/22 15

18 , Edition / Bak Page 18/22

19 11. Spare parts list Item Qty. Name EDVNO Remarks 01 1 Decorative foil Sheet metal screw M2x9 DIN Plastic semi-circular ring Securing sleeve Ondal Securing segment Brake screw Screw M3x4 DIN 966:Ni for cover Cover RAL Halogen lights 33 1 Cover RAL LED lights 10 1 Lateral cover, left Stopper Handle half RAL Halogen lights 1 Handle half RAL LED lights 13 1 Four-foot base for Mach Four-foot base with weighting plate for Mach Roller Roller with brake Connecting cable with plug Electronic transformer 230V/24V 80W* Mach 120 only 19 1 Spring arm for stand 1,7 kg for Mach Spring arm for stand 3,2 kg for Mach Spring arm for stand 1,8-2,7 kg for LED 120/ Screw M3x10 D7985:Zn Lock washer A3, Fuse holder incl. fuse T 10A L for Mach Stand tube with transformer, complete for Mach Stand tube without transformer, complete for Mach Cover for toroidal transf., consisting of: - Cover, 1 piece - Clamp ring, 1 piece - PT-screw M3x4, 1 piece 27 1 Transfomer base, complete, consisting of: - Base with 2 clamps, 1 piece - Base, 1 piece - Clip, 2 pieces - PT-screw M4x30, 2 pieces Ondal Ondal Toroidal transformer 90W Support plate for transformer, Ø90xØ50x1,5 Ondal Fuses 5 x 20 mm, 0,8A time lag T 230V 31 2 Fuses 5 x 20 mm, 1,6A time lag T 120V Edition / Bak Page 19/22

20 Appendix to the mounting instructions Acrobat-Swing mobile stand (Mobile stand with pre-mounted toroidal transformer) This applies to mach 120 only! 1. Mounting of the half rings are not applicable. 2. To adjust the cover to the base Turn the cover clockwise Edition / Bak Page 20/22

21 Tighten the 2 fixing screws M4x8. Fixing screws 3. Changing the fuses To protect the transformer and the end device, the fuses are installed. WARNING! ELECTRICAL SHOCK For all maintenance work, switch off the equipment, pull out the main plug and secure it form being switched on again. The technical specification for the fuses can be found on the back side of this document and on the label inside the cover. CAUTION! Damage to the equipment Apply only the specified fuses. Change the fuses corresponding to the following steps: 1. Open the cover Loosen the screw, but do not unscrew it completely Edition / Bak Page 21/22

22 Push up clamp ring and cover and secure them. 2. Changing the fuses Change the broken fuse. 3. Close the cover Push up clamp ring and cover downwards. Tighten the screw Edition / Bak Page 22/22

STAND MODEL FOR MACH M2

STAND MODEL FOR MACH M2 Mounting instructions Directions for use STAND MODEL FOR MACH M2 Stand lamps: Mach M2... Mach M2 F... Order No. 170 120 1300 Order No. 170 230 1300 GmbH u. Co. KG, Flossmannstrasse 28, D-85560 Ebersberg

More information

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com,

More information

CEILING ATTACHMENT FOR MACH M2

CEILING ATTACHMENT FOR MACH M2 Mounting instructions Directions for use CEILING ATTACHMENT FOR MACH M2 Ceiling lamps: Mach M2... Mach M2 F... Order No. 170 120 3330 Order No. 170 230 3330 GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg

More information

CEILING ATTACHMENT ACROBAT SWING

CEILING ATTACHMENT ACROBAT SWING Mounting instructions Directions for use CEILING ATTACHMENT ACROBAT SWING Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: HUwww.dr-mach.com

More information

STAND FOOT - STAND TUBE

STAND FOOT - STAND TUBE Mounting instructions Directions for use STAND FOOT - STAND TUBE Stand lamps: Mach 130 / Mach 130F Soloflex Triaflex / Triaflex R96 Trigenflex / Trigenflex R96 GmbH u. Co., Flossmannstrasse 28, D-85560

More information

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital Mounting instructions Directions for use MAKROLUX Halogen-spot lamp for consulting room and hospital Stand model with five-feet base, design without heat protection filter 1100 1012 00 Stand model with

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Mounting instructions MACH LED 3MC/SC STAND MODEL Mach LED 3MC stand lamp Order No. 370 530 1200 Mach LED 3SC stand lamp Order No. 360 530 1200 Accessories Surcharge for integrated laser pointer Order

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Directions for use SOLOFLEX Stand lamp one-handed height adjustment Order No. 1281 3011 00 Stand lamp - swivel arm Order No. 1281 3012 00 Wall lamp Order No. 1281 3021 00 Ceiling lamp for room heights

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering DIRECTIONS FOR USE Triaflex Stand lamp Order No. 3001 1012 00 Wall lamp Order No. 3001 1021 00 Single ceiling lamp Order No. 3001 1031 25 Order No. 3001 1031 30 Ceiling lamps combinations Emergency power

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH

More information

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering Mounting instructions Directions for use EMERGENCY POWER LAMP Triaflex / Triaflex R96 emergency power lamp Trigenflex / Trigenflex R96 emergency power lamp Mach M3 F- / DF- / F/H- / DF/H emergency power

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed. Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents

More information

Service manual. English. F5 Corpus

Service manual. English. F5 Corpus Service manual English F5 Corpus Introduction The Service Manual is intended for technical personnel who maintain and repair power wheelchairs. It is important that anyone who performs maintenance and

More information

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: & HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting

More information

Ropox Shower & Changing Bed

Ropox Shower & Changing Bed Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,

More information

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting

More information

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair SERVICE MANUAL US Permobil M300/M400 Power Wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 2, 2011-06 Article no.: 205261-US-0

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations.

More information

D-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M

D-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M DENTAL LIGHT D-LUX TM Model AL-711M Model AL-712M Model AL-715M INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that

More information

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z Operating manual ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz 574 228 / Z-008-1380 02418V10 [GB] - 2016 Subject to change! Änderungen vorbehalten! ZSK Stickmaschinen GmbH Printed in Germany [ GB ] 02418V10

More information

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1 OPERATING MANUAL BAK Thermoplastic Welding Technology AG 1 SAFETY Danger to life Unplug the tool before opening it as live components and connections are exposed. Danger of fire and explosion in case of

More information

Operating instructions Assembly instructions

Operating instructions Assembly instructions MOBILITY MADE SIMPLE! Adapter & Adaptation Operating Instructions Operating instructions Assembly instructions Adapter & adaptation for NJ1 e-assistant, NJ1 adaptive bike, SPIKE adaptive bike and FREEWAY

More information

HEINE NT4 MED V

HEINE NT4 MED V HEINE NT4 MED 113594 2018-01-23 V-200.00.601 HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively

More information

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit Installation Guide Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter. 2. Describe attachment of Mounting

More information

Maintenance Information

Maintenance Information Form 16575334 Edition 1 April 2005 Electric Screwdrivers EL, EP and ET 34V DC Series Maintenance Information Save These Instructions WARNING Maintenance procedures have the potential for severe shock hazard

More information

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company Oreck Magnesium Series Service Manual The Oreck Manufacturing Company 08/2012 10/2011 The Oreck Manufacturing Company Contents Covering all Magnesium Upright Models Including: LW100, LW125, LW1000, AND

More information

Hydraulic Impact Wrench Type

Hydraulic Impact Wrench Type M a s c h i n e n f a b r i k G m b H Hydraulic Impact Wrench Type 6 1520 0010 Illustration can differ from the original Operation and Maintenance Manual 615200010_en_Version_03 Page 1 of 19 TECHNICAL

More information

User manual. Model Mini, Small, Medium and Large

User manual. Model Mini, Small, Medium and Large User manual Model Mini, Small, Medium and Large 2 Contents Introduction..3 CE marking and labels...3 Safety precautions..3 Prior to first use 4 Meywalk 4 parts...4 Joining the top part and bottom frame.5

More information

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter (page 2). 2. Describe

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Drive unit. Installing/removing ebike components. Tool: Allen key size 8. ISIS crank-puller. Spider-Tool. Lever (e.g.

Drive unit. Installing/removing ebike components. Tool: Allen key size 8. ISIS crank-puller. Spider-Tool. Lever (e.g. Removing the chain wheel Remove the crank arms (Allen key size 8, ISIS crank-puller). Block the rear wheel. Tip: Clamp the brake lever with Velcro. Unscrew the lock ring () with the Spider-Tool (). Caution:

More information

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908 DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS

More information

Register your instrument! HeatSealer S100. Operating manual

Register your instrument!   HeatSealer S100. Operating manual 00N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2015 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

NOKOMMS. kéï=~ë=çñw= pfoliru c^kq^pqf` fåëí~ää~íáçå=fåëíêìåíáçåë=iáöüí=qê~åâ=póëíéã. båöäáëü

NOKOMMS. kéï=~ë=çñw= pfoliru c^kq^pqf` fåëí~ää~íáçå=fåëíêìåíáçåë=iáöüí=qê~åâ=póëíéã. båöäáëü kéï=~ë=çñw= NOKOMMS pfoliru c^kq^pqf` fåëí~ää~íáçå=fåëíêìåíáçåë=iáöüí=qê~åâ=póëíéã båöäáëü General information Sirona Dental Systems GmbH General information About this document This document describes

More information

PIL0478 ISSUE 01/ 07/16

PIL0478 ISSUE 01/ 07/16 ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW

More information

Bulb Replacement REPLACING BULBS

Bulb Replacement REPLACING BULBS Bulb Replacement REPLACING BULBS Check the operation of all exterior lamps before you drive the vehicle. Caution: Before attempting to replace a bulb, ensure that both the affected lamp and the vehicle's

More information

Globe Control Valve Series 1a

Globe Control Valve Series 1a Maintenance Globe Control Valve Series 1a are subject to alteration without notice. The text and illustrations do not necessarily display the scope of supply or any ordering of spare parts. Drawings and

More information

Maintenance Information

Maintenance Information 80234313 Edition 1 June 2006 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

Isolation Transformer for Medical Applications

Isolation Transformer for Medical Applications User Instructions Isolation Transformer for Medical Applications Type: Isolation Transformers REOMED 300VA; REOMED 600VA; REOMED 1000VA REO (UK) Limited Units 2 4 Callow Hill Road, Craven Arms Business

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: ) EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words

More information

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 v1.5 07.07.2011 Table of contents 1. Safety measures... 2 2. Phase spin direction test... 3 3. Motor shaft spin direction (using

More information

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2 INSTRUCTION MANUAL Contents Introduction Inspection Notes on Safety Precautions i i ii vii Chapter 1 Overview 1 1.1 Product Overview 1 1.2 Names of Parts 2 Chapter 2 Specifications 5 2.1 Product Specifications

More information

Maintenance Information

Maintenance Information 80234313 Edition 2 May 2014 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the

More information

Servicing front brakes

Servicing front brakes 46-1 Servicing front brakes C54 brake caliper, servicing Special tools and workshop equipment required VAG 1331 Torque wrench (or equivalent) VAG 1410 Torque wrench (or equivalent) VAG 1869/2 Brake pedal

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL

SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL SO-161-R Ophthalmic Microscope User Manual Page 2 of 18 CONTENTS CONTENTS 2 LIST OF FIGURES 2 INTRODUCTION 3 INTRODUCTION 3 PARTS LIST 5 ASSEMBLY INSTRUCTIONS

More information

Cordless Screwdriver

Cordless Screwdriver ENGLISH Cordless Screwdriver MODEL 6796D MODEL 6796FD MODEL 6797D MODEL 6797FD MODEL 6798D MODEL 6798FD 00260 I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before

More information

Hydraulic Rotary Hammer Drill

Hydraulic Rotary Hammer Drill M a s c h i n e n f a b r i k G m b H Hydraulic Rotary Hammer Drill Type 2 2406 0010 Techn. Doc. No. 262 Illustration can differ from the original Repair Manual and Spare Parts List 224060010_Inst_en_Version_06.doc

More information

Maintenance Information

Maintenance Information 04581245 Edition 2 May 2014 Air Grinder, Die Grinder and Sander Series G2 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,

More information

Operating instructions ErgoPack 600 E

Operating instructions ErgoPack 600 E Operating instructions ErgoPack 600 E Operation of the device is only permitted if the operating instructions have been carefully read and understood before use! Declaration of conformity EU declaration

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

6 x 10 Belt Disc Sander

6 x 10 Belt Disc Sander 6 x 10 Belt Disc Sander FOR HELP OR ADVISE ON THIS PRODUCT PLEASE CALL OUR CUSTOMER SERVICE HELP LINE : 01509 500400 THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE DESIGN OR SPECIFICATION TO THIS PRODUCT

More information

Disassembly. 1 Pull off the QUIK-LOK cable from the machine.

Disassembly. 1 Pull off the QUIK-LOK cable from the machine. Special Tools Require Important! Torx TX0 bit 0 0 Screwdriver Torx 0 0 0 Forcing Discs 0 Before beginning the maintenance work, perform an initial check with a high voltage test according to VDE (see chapter

More information

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3 Page 1 Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3 Please Note: It is preferable to park on a flat surface, as you will have to engage and disengage

More information

Linear Luminaire for Fluorescent Lamps

Linear Luminaire for Fluorescent Lamps Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP Operating Manual for extrusion valve MMKD-40 KV/LV/LVP Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau

More information

Spear & Jackson 37 cc Petrol Chainsaw Original Operating Instructions

Spear & Jackson 37 cc Petrol Chainsaw Original Operating Instructions Spear & Jackson 37 cc Petrol Chainsaw Original Operating Instructions Assembly Manual After Sales Support UK/Ireland 0151 649 1500 Republic of Ireland 1890 946 244 Web www.einhell.co.uk Important - Please

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Re.Formance Line INSTRUCTION MANUAL 1703

Re.Formance Line INSTRUCTION MANUAL 1703 Re.Formance Line INSTRUCTION MANUAL 1703 320.8779.02 / 1703 Re.Formance Line Table of contents 1. Overview... 3 1.1 Re.Forma Hi.... 3 1.2 Re.Forma... 3 1.3 Re.Forma Lite.... 3 2. Notes... 4 2.1 Warranty

More information

Maintenance Information

Maintenance Information 45530136 Edition 1 July 2008 Electric Screwdrivers EL 24V DC Series Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing maintenance on this tool.

More information

Before use please read & understand this manual, paying particular attention to the safety instructions.

Before use please read & understand this manual, paying particular attention to the safety instructions. OPERATOR S MANUAL AND PARTS LIST 800W ELECTRIC TILLER - THET-A Sales & Helpline 01793 333212 www.thehandy.co.uk Before use please read & understand this manual, paying particular attention to the safety

More information

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN Type 3571 Pneumatic Actuator Actuator areas: 27 in² 54 in² 116 in² Original instructions Mounting and Operating Instructions Edition April 2016 Note on these mounting and operating instructions These mounting

More information

User Manual SONESTA S2 & S3

User Manual SONESTA S2 & S3 User Manual SONESTA S2 & S3 Sonesta manufactures and sells tables and chairs for urology, gynecology, urodynamic diagnostics and upper GI procedures Copyright 2018 SONESTA MEDICAL AB. All rights reserved.

More information

The pneumatic applicator complies with the following safety guidelines: CE

The pneumatic applicator complies with the following safety guidelines: CE Copyright by Carl Valentin GmbH / 7952525A02.11 Information on the scope of delivery, appearance, performance, dimensions and weight reflect our knowledge at the time of printing. We reserve the rights

More information

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (12V) Troubleshooting Guide: 355 Lights (12V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling)

More information

M M 4 M M 8 M M 1 2 M M 1 2 M : : C

M M 4 M M 8 M M 1 2 M M 1 2 M : : C MM4 MM8 MM12 MM12M User s manual Reference : 39786125818 Edition : C - 20/02/2003 Summary Installation and maintenance should be performed by qualified service personnel Installation.......................................................p.

More information

AF7006 Alarming Camera Display Unit (6.5 ) AF7015 Alarming Camera Display Unit (4.5") AF7216 Camera Sensor

AF7006 Alarming Camera Display Unit (6.5 ) AF7015 Alarming Camera Display Unit (4.5) AF7216 Camera Sensor How to Setup a Display Unit AF700 or AF70 AF7 AF700 Alarming Camera Display Unit (. ) AF70 Alarming Camera Display Unit (.") AF7 Camera Sensor Battery-powered alarming system with AC power connections

More information

TB-356/356 S. Conveyor / Stacker INSTRUCTION MANUAL

TB-356/356 S. Conveyor / Stacker INSTRUCTION MANUAL TB-356/356 S Conveyor / Stacker INSTRUCTION MANUAL Rev. 3/17/04 Part#: M-3027 RENA Systems, Inc. 136 Green Tree Rd Ste 140 PO Box 1069 Oaks, PA 19456-1069 Telephone: 610/650-9170 Fax: 610/650-9171 Every

More information

Installation Guide Roll Stand Kit for Philips MP20/30 Monitor

Installation Guide Roll Stand Kit for Philips MP20/30 Monitor Installation Guide Roll Stand Kit for Philips MP20/30 Monitor The purpose of this guide is to: 1. Describe attachment of Post to Base (page 2). 2. Describe attachment of the Utility Basket to the Roll

More information

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 OPERATION 8 SPECIFICATIONS 8 MAINTENANCE 9 HOME CHARGER MODE 2 Series 31328 to 31340 16/32A single phase FCC INFORMATION 9 WARRANTY

More information

User manual Patient chair Malin

User manual Patient chair Malin User manual Patient chair Malin - Model 120-00103-00 Rock - Model 120-00103-01 Swing - Model 120-00103-02 Slim Behandlingsstol 120-00103-0n 2007-0013 issue 7 Tel +46-8- Table of content 1. Rini patient

More information

HD18F2M1.

HD18F2M1. HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed

More information

Linear Luminaire with LED

Linear Luminaire with LED Linear Luminaire with LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3

More information

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011

More information

OLYMPIAN MODEL 740 Operation and Service Manual

OLYMPIAN MODEL 740 Operation and Service Manual OLYMPIAN MODEL 740 Operation and Service Manual P/N 133911-102 FCI MANUAL P/N 133865-001 Data herein has been verified and validated and believed adequate for the intended use. If the machine or procedures

More information

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL Imported exclusively by Pacific Hoists Pty. Ltd. & Pacific Hoists Ltd. In support of cancer charities in Australia & New Zealand 2 www.jbstools.com WWW.CHALLENGERHOISTS.COM.AU

More information

Operating Manual for sprayvalve MKDD-IS

Operating Manual for sprayvalve MKDD-IS Operating Manual for sprayvalve MKDD-IS Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau GmbH - Spritztechnik

More information

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3

More information

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER Table of Contents Page Tools Needed (A) 3 Replacement

More information

Instruction Manual. Made in Israel Distributed by:

Instruction Manual. Made in Israel Distributed by: Instruction Manual Made in Israel Distributed by: 1333 South Claudina Street Anaheim, CA 92805, U. S. A. Toll Free: (800) 854 9305 Telephone: (714) 533 2221 FAX: (714) 635 7539 Web Site: http://www.mettlerelectronics.com

More information

Operating Instructions Type MPT 53

Operating Instructions  Type MPT 53 Operating Instructions www.turnstiles.us Type MPT 53 Contents 1. Delivery... 2 2. Safety...3-4 3 Description and operation... 5 4. Technical Data 6 5. oundation...6-9 6. Assembly and installation...10-13

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the

More information

2006 MINI Cooper SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S

2006 MINI Cooper SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S WHEELS 2002-05 SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S 36 10 300 REMOVING OR INSTALLING FRONT OR REAR WHEEL NOTE: For Special Tool identification, see WHEEL AND

More information

Peristaltic Pump Operating Instructions

Peristaltic Pump Operating Instructions Peristaltic Pump Operating Model 410 IMPORTANT Pump is water resistant but not waterproof. Do not submerge in water. Pumping rates will decrease as the amount of lift increases. Remove tubing when stored.

More information

Instructions for Fitting, Operating and Maintenance

Instructions for Fitting, Operating and Maintenance EN Instructions for Fitting, Operating and Maintenance Retractable Door 1 818 024 RE / 10.2011 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words used...

More information

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection 1 PRODUCT DESCRIPTION 1.1 Usage in accordance with safety standards 1.1.1 General Information 1.1.1.1 Hazards and precautions 1.1.1.2 Brief description 1.1.1.3 Safety standards 1.1.1.4 Included items 1.1.1.5

More information

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1 1 2 1 5 4 3 2 2 1 6 3 8 7 1 9 4 C A B 5 0 0 D E 6 G 7 F F H 8 K 9 M O O I J L N 1 GENERAL OPERATIONAL PRECAUTIONS 1. Keep work area clean. Cluttered areas and benches invite accidents. 2. Avoid dangerous

More information

BPW height-adjustable drawbars

BPW height-adjustable drawbars Maintenance instructions ZAV BPW BERGISCHE ACHSEN BPW height-adjustable drawbars Series ZAV REPAIR, MAINTENANCE AND OPERATING INSTRUCTIONS Maintenance and Operating Instructions ZAV Table of contents:

More information

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating

More information

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm² Type 3271 and Type 3277 Pneumatic Actuators Actuator areas: 175v2, 350v2, and 750v2 cm² Translation of original instructions Type 3271 (left) and Type 3277 (right) Pneumatic Actuators Mounting and Operating

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Light Source User Guide

Light Source User Guide Light Source User Guide Compact Light Source Range Models covered by this manual: UFO 70/150 CG Glass, White Light - 240V UFO 70/150 CP Plastic, White Light - 240V UFO 70/150 CGC Glass, Colour Wheel (continuous)

More information