About us. 2 make your work surroundings safer

Size: px
Start display at page:

Download "About us. 2 make your work surroundings safer"

Transcription

1

2 About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment in company employees and organization, we continue the tradition of more than 60 years of experience in the field. Long-term company policy relies on our people and delivery of innovative products from our own development teams. Aiming for excellence is for us one of the most important corporate values. Our products are intended for use in potentially explosive atmospheres of gases, vapors and dust in industries such as refineries, offshore installations, petrochemical industry, chemical industry, pharmaceutical industry, food processing, shipbuilding and underground mining. The production program includes Ex light fittings, Ex installation material and accessories, Ex control units, Ex signal devices, Ex terminals, Ex distribution cabinets up to 630 V and 500 A. In accordance with national regulative, all of our products and systems for quality assurance are certified by an authorized certification institution in the Republic of Croatia Ex Agency. At European level, the certification was carried out according to the ATEX Directive 2014/34/EU by an authorized certification notified body CESI and Ex Agency. All of our products and systems for quality assurance are certified according to certification was carried out according to the GOST TR CU (Technical Regulation Customs Union) certificates are official documents certifying the conformity of the production with the standards of the Customs Union formed by Belarus, Kazakhstan and Russian Federation. The production process is conducted according to high standards of ISO 9001 (Quality Assurance System) and ISO (Environmental Management System), ensuring high quality products with constant care for environment. Based on our long history in producing supreme quality explosion protected electrical equipment, we are ready to deal with every demand or specific requirement of our customers. If you would need any additional information regarding our products or our company, we will be glad to answer your questions, with the professional approach from our Communication team. 2 make your work surroundings safer

3 Explosion protected products from the middle of the last century Examples of today's Ex products 3

4 Production The electrical equipment installed in areas with risk of explosion must be designed and tested in such way that it does not cause arcing or high temperatures which would provide a source of ignition for such a mix. For this reason, these materials must be provided only by companies able to attach the relevant product certificate of compliance with international standards. This certificate, issued by competent and government authorized laboratories along with a test report, proves that the product is totally safe and suitable for installation in the concerned plant. TEPEx Quality System conforms to the requirements of: EN ISO 9001:2008 and EN ISO/IEC :2011. All our Ex-protected products are certified in accordance with the European standard ATEX Directive 2014/34/EU, also obtained the certifications for the Russian market (Custom union), EAC. 4 make your work surroundings safer

5 Ex LED light fittings Following new trends in Ex lighting, and the advent of LED sources in explosive areas, TEPEx already in started production of Ex light fitting with LED light source (LED FLXE 118). Currently, several types of Ex certified LED lamps (pendant/max. 80W and linear LED lamps with 36W). The main advantages of LED lighting over conventional (mercury, fluorescent, metal-halide...) lighting. Durability Energy efficiency selectable color temperature environmentally friendly In we plan to start production of Ex pendant light fittings ~120W, and linear LED light fitting in GRP (Polyester) housing, Ex e type PSF 52 LED, PSF 28 LED. Ex LED light fitting type PSF 52 LED linear Modern LED lighting has a significantly longer service life than conventional lighting, does not contain harmful compounds (mercury, cadmium...), does not emit UV rays and releases significantly less heat energy. When creating light-technical calculations it should be noted that the LED lighting (directional light) contribute to the reduction of light pollution of the atmosphere and losses on light scattering. 5

6 Contents Ex BULKHEAD LIGHT FITTINGS, PENDANT LIGHT FITTINGS, FLOODLIGHTS Bulkhead light fitting Pendant light fitting PLFM 16 Pendant light fitting PLFS 20 Pendant light fitting PLFL 22 Floodlight RLF 24 Ex FLUORESCENT LIGHT FITTINGS, EMERGENCY LIGHT FITTING Fluorescent light fitting PSF 28 Emergency light fitting PSF E 30 Fluorescent light fitting FLX 32 Emergency light fitting FLXE LED 36 Fluorescent light fitting SIF 38 Ex LED LIGHT FITTINGS Bulkhead light fitting LED Pendant light fitting PLFM 20 LED 42 Pendant light fitting LED Pendant light fitting PLFS 50 LED 46 Linear LED light fitting FLX 310 LED 48 Linear LED light fitting PSF LED 50 Ex INSTALLATION EQUIPMENT Installation switch SKX SW 54 Junction boxes RK Junction boxes JBX 58 Terminal boxes SKX./E 60 Terminal boxes SKX./E INOX (AISI 316L) 70 CONTROL UNITS Control units SKX 12. SKX Control units SKX SKX Grounding device GGCD 102 DISTRIBUTION CABINETS, BUSBAR ENCLOSURES Distribution cabinets R R Busbar enclosure SKX 110 SIGNALLING DEVISE, PLUGS AND SOCKETS, ACCESSORIES Signal horn dhh, 114 Signal bell dhw 116 Telephone dst1 118 Torchlights DF, headlamp DS 120 Plugs and sockets 122 Adapter ADP 128 Multicore bushing RSM 130 Electronic ballast SMP 132 Cable glands, adapters, reducers, locknuts make your work surroundings safer

7 Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion. The amount of a substance needed to create an explosive atmosphere depends on the substance in question. The area where this possibility exists is defined as a potentially explosive atmosphere. These atmospheres can be found throughout industries, from chemical, pharmaceutical, food, to power, and wood processing. The areas may also be known as hazardous areas or hazardous locations.

8 GUIDE FOR EXPLOSION PROTECTION Equipment and products operating in hazardous areas are required to meet stringent criteria. They must be protected to avoid the possibility of them becoming a source of ignition. If the danger of explosion cannot be completely or only partly avoided by measures of preventing the formation of an hazardous explosive atmosphere, then measures must be taken that avoid the ignition of the explosive atmosphere. Integrated explosion protection PRIMARY Preventing the formation of an explosive atmosphere SECONDARY Avoidance of the ignition of an explosive atmosphere TERTIARY Mitigation of the effects of an explosion to an acceptable extent Categories / Protection levers / Zones AREAS CATEGORIES EPL ZONES EXPLOSIVE ATMOSPHERE Mining - I Other than mines - II EPL - Equipment Protection Level M1 Ma >1,5% CH4 / M2 Mb <1,5% CH4 1G, 1D Ga, Da 0, 20 Continuously, long term ог frequently 2G, 2D Gb, Db 1, 21 Likely to occur 3G, 3D Gc, Dc 2, 22 Not likely to occur, short period G - Gas D - Dust a - very high protection level b - very high protection level c - extended protection level Maximum Surface Temperature Temp. Class Gas Groups 450 C 300 C 200 C 135 C 100 C I IIA 85 C T1 T2 T3 T4 T5 T6 ammonium, ethane, propane, benzene, methanol ethyl n-butanol, n-butyl alcohol IIB LPG mix ethylene benzine, kerosene, n-hexane, diesel fuel hydrogen sulphide methane etileter, acetilaldehid, benzaldehyde, dibutileter, diheksileter - - etileter, dietileter - - IIC hydrogen acetylene carbon disulphide IIIA IIIB IIIC Dust Groups Combustible flyings Non-conductive dust Conductive dust Dust Flash point [ C] layer cloud Minimum ignition energy (cloud) [mj] Lower Explosion Limit (cloud) [g/m 3 ] Cellulose Sugar Strach Wheat Sawdust Aluminium powder Zinc Asphalt make your work surroundings safer

9 Type of protection Types of protection for explosive atmosphere of flammable gases, vapors, mists or dusts EN/IEC General Requirements Type of protection Standard Concept Symbol Category EPL Flameproof EN/IEC d 2G M2 Gb Mb Increased safety EN/IEC e 2G M2 Gb Mb Pressurized EN/IEC px, py, pz M2, 2G, 3G 2D, 3D Mb, Gb, Gc Db, Dc Intrinsic safety EN/IEC ia, ib, ic M1, M2, 1G, 2G, 3G 1D, 2D, 3D Ma, Mb, Ga, Gb, Gc Da, Db, Dc Type of protection n EN/IEC na nc nr 3G Gc Powder filling EN/IEC q M2, 2G Mb, Gb Oil - immersion EN/IEC o M2, 2G Mb, Gb Encapsulation EN/IEC ma mb Mc M1, M2, 1G, 2G, 3G 1D, 2D, 3D Ma, Mb, Ga, Gb,Gc Da, Db, Dc Protection by enclosures EN/IEC td ta, tb, tc 1D, 2D, 3D Da, Db, Dc Optical radiation EN/IEC op _a op _b op _c 1G, 2G, 3G Ga, Gb, Gc Type of protection for non-electrical equipment EN / IEC Flow restricting EN fr 3G, 3D / Flameproof EN d M2, 2G / Constructional safety EN priec c M2, 1G, 2G, 3G 1D, 2D, 3D Mb, Ga, Gb, Gc Da, Db, Dc Control of ignition sources EN priec b M2, 1G, 2G, 3G 1D, 2D, 3D Mb, Ga, Gb, Gc Da, Db, Dc Liquid immersion EN priec k M1, M2, 1G, 2G, 3G 1D, 2D, 3D Ma, Mb, Ga, Gb, Gc Da, Db, Dc Pressurized EN/IEC p M2, 2G, 2D 3G, 3D / 9

10 GUIDE FOR EXPLOSION PROTECTION EXAMPLES OF A CLASSIFICATION INTO ZONES 10 Above drawings are examples only and must not be used as a model for an actual plant whose design is, in every case, the responsibility of the constructor and operator. make your work surroundings safer

11 Typical Electrical Equipment Marking According to 2014/34/EU No. Description 1 Manufacturer s name and address 2 Product identification 3 Technical data 4 Indication of the Equipment Category and Hazardous Atmosphere 5 Marking of explosion protection 6 Conformity symbol, EU symbol 7 Notified body (ExNB) 8 Standard ambient temperature ( C), unless stated on label 9 Certificate number and product number 11

12 NOTES

13 Light fittings

14 Zone E27 IP 64 C IM2 incandescent lamps up to 100 W and halogen lamps up to 77 W Through-wiring possible For use in underground mines CONSTRUCTION Housing: /10, /11, /12 - aluminium powder painted casting /20 - cast iron Diffuser: borosilicate glass protected with steel gird TECHNICAL DATA Certificate: EXA 15 ATEX 0070X RU C-HR.AB24.B Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: Degree of protection: Resistance to shock: IK 08 Protection class : II 2GD, I M2 Ex d e IIC T3-T2 Gb Ex tb IIIC T130 Db Ex d e I Mb -40ºC T a +40/50/60ºC - type II 2GD -20ºC T a +40ºC - type I M2 IP 64, category 1 - type II 2GD IP 54, category 1 - type I M2 I (protective earthing) Rated voltage: Frequency: Rated power: Light output ratio: Lamps: Connecting terminals: Cable entry: Cover fixing: Packing: 230V AC, 110V AC, 24V AC/DC 50Hz (60Hz on request) See selection table η=0,68% Incandescent lamps, E 27 lampholder, up to 100W Halogen lamps, E 27 lampholder, (77W A ECO) Terminals L1 + N for 2 x 4 mm ² flexible/solid Terminals PE for 2 x 4 mm ² flexible/solid/stranded Tightening torque for screw clamp 2,2 Nm 1 x M25x1.5 cable gland (through-wiring possible) 1 x M25x1.5 plug M 6, Hexagonal screw; without switch The packing contains: 1 pcs 360x240x205 mm 14 make your work surroundings safer

15 Bulkhead light fitting MODEL CODE Model code Apparatus category Explosion protection Rated voltage Max. wattage Luminou s flux WEIGHT / /11,12 (signal red or green glass) II 2G Ex d e IIC T2,T3 Gb Ex d e IIC T3 Gb 230/110 V AC 230/110 V AC, 24 V AC/DC 230 V AC 230 V AC 100W max. 60W max. 77W max. / A ECO 1500 lm 800 lm 1320 lm 4,3 kg 40W max. 450 lm 4,3 kg /20 I M2 Ex d e I Mb 230 V AC 100W max lm 7,5 kg POLAR CURVE DIMENSION DRAWING (all dimensions are in mm) MOUNTING Two brackets with two screws M6 SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Ex d lampholder E27 set Ex e cable gland M25 SPU 25 Gasket II M2 Ex e I Cable gland Replacement glass Ex e plug M25 SPC 25 Light bulb 40W, 60W, 100W I M2 Ex e I Plug M All technical data is relevant at the time of print. 15

16 Zone PLFM E27 IP 66 C Low weight/3,5 kg Up to 70W HSE (5900 lm) CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass Accessories: protected galvanized steel gird (INOX on request), assembly kit for wall, pipe and ceiling mounting TECHNICAL DATA Certificate: EXA 14 ATEX 0056X and 0056X/1 RU C-HR.AB24.B Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2GD Degree of protection: IP 66, category 1 Resistance to shock: IK 08 Ex d e IIC T6-T3 Gb Ex d IIC T6-T3 Gb Ex tb IIIC T80ºC - T155ºC Db -20ºC T a +40ºC [ATEX] -50ºC T a +40ºC [EAC] Protection class : Rated voltage: Frequency: Rated power: Light output ratio: Cable entry: Connecting terminals: Weight: Packing: I (protective earthing) 230V AC PLFM FLASH - see model code table 50Hz (60Hz on request) See model code table η=0,75% 2 x M20x1.5 II 2G Ex d e IIC Gb, II 2D Ex tb IIIC Db ADP 23/1 II 2G Ex d e IIC Gb, II 2D Ex tb IIIC Db L, N, PE; max. 2 x 2,5 mm 2 solid, flexible terminal for external -PA connection; max 2x6 mm 2 3,5 kg > PLFM 100/., PLFM FLASH-. 4,5 kg > PLFM 20 LED-., PLFM 70 HSE-. The packing contains: 2 pcs 340x260x170 mm 16 make your work surroundings safer

17 Pendant light fitting PLFM Basic type code Maximal wattage and type of sources: A incandescent lamp 100W max, A ECO halogen lamp 105W max, QT halogen lamp 100W max. 100/1 - LME mixed discharge lamp 100W max. 100/2 - TC-SB compact fluorescent lamp 23W max. 100/3 - LED BULB lamp 15W max. 20 LED - LED MODUL special 20W max. FLASH - XENON MODUL special 5W max. 70 HSE - HSE-I high pressure sodium discharge lamp 70W, HSE-I high pressure sodium discharge lamp 50W. Type of entries: 1 indirect entry type with Ex e junction box, 2 indirect entry type with Ex d adapter ADP 23/1, MODEL CODE Model code Max. wattage Lamp type Nominal voltage Luminous flux PLFM Lamp holder Temp. class (gas) T a =40 C T 0 MAX (dust) T a =40 C 100 W A 230V 1340 lm E27 T4 130 C 116 W Osram 105 W Philips A ECO 230 V 2135 lm Osram 1980 lm Philips E27 T4 130 C 100 W QT 230 V 1800 lm Osram E27 T4 130 C PLFM 100/ W LME 230 V, 50 Hz 1100 lm E27 T3 155 C PLFM 100/2 -. PLFM 100/ W Osram 23 W Philips 12 W Osram 13 W Philips TC-SB 230 V, 50 Hz 1440 lm E27 T6 80 C LED 230 V, 50 Hz 810 lm Osram 1055 lm Philips E27 T6 80 C PLFM 20 LED W LED modul 230 V, 50 Hz 1300 lm - T6 80 C PLFM FLASH -. 5 W XENON PLFM 70 HSE -. MOUNTING 70 W HSE Pendant, on pipe, wall, ceiling V DC 110 V AC 230 V AC 230 V, 50 Hz 50W HSE 230 V, 50 Hz With vertical suspension on the bolt with ring bolt head M8 Wall mounting bracket 4J/90Hz - T6 80 C 5900 lm Osram 5600 lm Philips 3600 lm Osram 3500 lm Osram E27 T4 130 C E27 T4 130 C All technical data is relevant at the time of print. 17

18 Zone PLFM POLAR CURVE PLFM 100-., PLFM 70 HSE With external reflector PLFM 100-., PLFM 70 HSE Without external reflector DIMENSION DRAWING (all dimensions in mm) PLFM 20 LED, 1300 lm SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Replacement glass PLFM PLFM Ex e cable gland M25 SPU 25 Wire guard PLFM PLFM Ex e plug M25, SPC 25 Gasket PLFM PLFM Light bulb According to type table Lampholder with internal reflector PLFM Ballast set PLFM PLFM fixing bracket for tube R 2 PLFM mounting bracket (ceiling mounting) PLFM PLFM Adapter ADP 23 PLFM PLFM mounting bracket (wall mounting) PLFM make your work surroundings safer

19 Pendant light fitting 19

20 Zone PLFS E27 IP 66 IP 67 C Heavy duty construction, aluminium enclosure and borosilicate glass Up to 150W HIE, lm CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass Accessories: protected galvanized steel gird, assembly kit for wall, pipe and ceiling mounting TECHNICAL DATA Certificate: CESI 06 ATEX 052 RU C-HR.AB.B Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2GD Ex d e IIC T4,T5,T6 Ex td A21 IP66 T80 C / T130 C Ex d e IIC T3/T4-20ºC Ta +40ºC / +50ºC [ATEX] -50ºC Ta +40ºC / +50ºC [EAC] Degree of protection: IP 66/67, category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: I (protective earthing) 230 V (-10% / +6%) (other voltage on request) 12 V AC/DC, 24 V AC/DC, 110 V AC, 230 V AC-lamp type PLFS- T/FLASH 50Hz (60Hz on request) See model code table Light output ratio: η=0,66% - 0,75% Cable entry: Connecting terminals: Cable gland and plug: Weight: Packing: two entries Ex e M25x1,5 L1, L2, L3, N; max. 2 x 2,5 mm2 solid, flexible terminal for protective earthing conductor connection -PE; max 2x6mm2 terminal for external -PA connection; max 2x6mm2 tightening torque for screw clamp 1,2 Nm II 2GD Ex e M25 IP66 tightening torque for gland screw 2,5 Nm tightening torque for gland and plug 3,5 Nm 8,6 kg The packing contains: 2 pcs 610x390x280 mm 20 make your work surroundings safer

21 Pendant light fitting MODEL CODE Model code Max. wattage Lamp type PLFS-T/200 PLFS-T/125 PLFS-T/100 PLFS-T/70 Luminous flux Lamp holder Temp. class (gas) T 0 MAX (dust) T a =40 C T a =50 C T a =40 C max. 200 W A 2500 Lm T4 max. 230 W QT 4200 Lm T4 T3 130 C max. 160 W LME 3150 Lm T4 max. 30 W TC-TSE 2300 Lm T6-80 C 125 W HME 6700 Lm W HSE-I 9500 Lm E27 - T4 130 C HSE 9000 Lm W HIE 8400 Lm - 70 W HSE HIE 5800 Lm 5500 Lm T5 T4 95 C PLFS-T/ W HIE Lm T4-130 C PLFS-T/FLASH 15 W / 11 J (in total) XENON - - T6-80 C POLAR CURVE DIMENSION DRAWING (all dimensions in mm) With external reflector Without external reflector SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Replacement glass PLFS-T PLFS-T Ex e cable gland M25 SPU 25 Wire guard PLFS-T PLFS-T Ex e plug M25, SPC 25 Base plate with lamp holder, ballast PLFS-T Light bulb According to type table PLSF-T cover Exe set PLFS-T PLFS-T fixing bracket for tube R 1 1/2 PLFS-T PLFS-T external reflector, wide PLFS-T PLFS-T mounting bracket (ceiling and wall mounting) PLFS-T PLFS-T external reflector, narow PLFS-T All technical data is relevant at the time of print. 21

22 Zone PLFL E40 IP 66 C Up to 250W discharge sources CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass Accessories: protected galvanized steel gird, assembly kit for wall, pipe and ceiling mounting TECHNICAL DATA Certificate: EXA 14 ATEX 0001 RU C-HR.AB24.B Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: Degree of protection: IP 66, category 1 Resistance to shock: IK 08 II 2GD Ex d e IIC T4-T3 Gb Ex d IIC T4-T3 Gb Ex tb IIIC T140ºC - T155ºC Db -20ºC Ta +40ºC / +50ºC [ATEX] -50ºC Ta +40ºC / +50ºC [EAC] Protection class : Rated voltage: Frequency: I (protective earthing) 230 V (-10% / +6%) (other voltage on request) 50Hz (60Hz on request) Rated power: See model code table Light output ratio: η=0,53% - 0,77% Cable entry: Ex d adapter: Connection terminals inside adapter, type PLFL-1/... Connection terminals inside light fitting External PA / PE terminal: Tightening torque: Weight: two entries Ex d, M20x1,5-6H type ADP 23/1, II 2G Ex d e IIC Gb II 2D Ex tb IIIC Db, cable gland ISO 25 for cable v 7-15 mm terminals for connection L + NE + PE; 2,5 mm 2, solid, stranded terminals for connection L + NE + PE; 2,5 mm 2, solid, stranded it is possible through wiring, I max = 16 A max 2 x 6 mm 2 flexible, 3 pcs. housing of Ex d e adapter and Ex d plug 3,5 Nm pressure nut of cable gland 2,5 Nm screws of Ex e terminal 1,2 Nm ca 18 kg PLFL-./500 A,IQ and PLFL/250 LME ca 23 kg - PLFL-./250 HIE, HSE, HME 22 make your work surroundings safer

23 MODEL CODE Pendant light fitting Model code PLFL/250 HIE, HSE, HSE Twinarc PLFL/250 HME Max. wattage 250 W Lamp type Luminous flux HIE HSE HSE Tw HME PLFL/250 LME LME Lamp holder E Temp. class (gas) T 0 MAX (dust) T a =40 C T a =50 C T a =40 C T4 140 C T3 PLFL/500 A,QT 500 W A 8400 QT C POLAR CURVE, DIMENSION DRAWING [mm] , , With external reflector Without external reflector SPARE PARTS AND ACCESSORIES 50 12,5 Sketch Description Code Sketch Description Code 365 Replacement glass PLFL PLFL Gasket set PLFL PLFL Wire guard PLFL PLFL Ex d plug M20, SPC Exd 20 Base plate with lamp holder, ballast PLFL Light bulb Acording to type table Adapter ADP 23 PLFS-T PLFL fixing bracket for tube R 1 1/2 PLFL PLFL externar reflector PLFL PLFL mounting bracket (ceiling and wall mounting) PLFL All technical data is relevant at the time of print. 23

24 Zone RLF E40 IP 66 C Up to 400W discharge sources QL source up to hours life time CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate tube glass Accessories: protected galvanized steel gird, assembly kit for wall, pipe and ceiling mounting TECHNICAL DATA Certificate: EXA 14 ATEX 0047 RU C-HR.AB24.B Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: Degree of protection: IP 66, category 1 II 2GD Ex d e IIC T4-T3 Gb Ex d IIC T4-T3 Gb Ex tb IIIC T130ºC - T195ºC Db -20ºC Ta +40ºC [ATEX] -50ºC Ta +40ºC [EAC] Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Light output ratio: Cable entry: Connection terminals inside light fitting External PA / PE terminal: Weight: Packing: I (protective earthing) RLF/... HIT,HST,HME,QT -230/240 V (-10% / +6%) / 50 Hz RLF/... QL -230 V ( V) - 50/60 Hz or ( V) - DC 50Hz (60Hz on request) See model code table η=0,60% RLF/... HIT,HST,HME,QT - three entries M20, with two Ex d plug and one Ex de adapter, type ADP 03/23, for cable 6-15 mm RLF/... QL - two entries M25 into Ex e junction box with one Ex e cable gland, type SPU 25, for cable v 6-15 mm and one Ex e plug RLF/... HIT,HST,HME,QT -clamps in Ex de adapter for connection L1, L2, N, PE, 2,5mm2 max. / clamp - solid, stranded; max 2 x 6 mm 2 flexible, 3 pcs. See model code table The packing contains: 1 pcs 600x400x300 mm 24 make your work surroundings safer

25 Floodlight MODEL CODE Model code RLF/250 HIT Max. wattage Lamp type Luminous flux HIE RLF/250 HST 250 W HST RLF/250 HME HME RLF/400 HIT HIE W RLF/400 HST HST RLF/500 IQT 500 W IQT RLF/300 IQT 300 W RLF/85 QL 85 W QL 6300 RLF/165 QL 165 W Lamp holder E40 Temp. class (gas) T a =40 C T 0 MAX (dust) T a =40 C Weight T4 130 C 25 kg T3 190 C QL T4 130 C 27 kg 22 kg POLAR CURVE Wide beam reflector Narrow beam reflector QL 165 W DIMENSION DRAWING (all dimensions in mm) RLF/... All technical data is relevant at the time of print. 25

26 Zone RLF SPARE PARTS AND ACCESSORIES If it is not ordered differently, floodlight RLF/... HIT,HST,HME,QT presume floodlight with RLF carrier, one Ex de adapter ADP 03/32 and two Ex d plugs, without light source and mounting accessories. Manufacturer will deliver spare parts and accessories on buyer request. Sketch Description Code Sketch Description Code Light bulb RLF Base plate HME Set RLF Mounting screw M12x40 RLF Gasket RLF RLF U screw M12 RLF Adapter Ex d e ADP 23/1 Base plate HIT, HST Set RLF Ex d plug M20 RLF If it is not ordered differently, floodlight RLF/... QL presume floodlight with RLF QL carrier, one Ex e junction box MMK 13 with Ex e connecting terminals, Ex e M25 cable gland, Ex e M25 plug, and Philips QL Induction Lighting System, without mounting accessories. Manufacturer will deliver spare parts and accessories on buyer request. Sketch Description Code Sketch Description Code MMK 13 gasket RLF QL Ex e plug M25 SPC 25 Ex e cable gland M25 SPU make your work surroundings safer

27 Floodlight 27

28 Zone PSF G13 IP 66 C IM2 T8 fluorescent lamps in parallel configuration Central locking Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply PSF use in underground mines CONSTRUCTION Housing: SMC polyester plastic reinforced with glass fiber Diffuser: PC polycarbonate plastic Gasket: silicone Central locking: can be opened/closed using a socket key SW8, hinged lamp cover The light fitting is normally supplied without light sources, socket key screw, two Ex e cable glands M25, two Ex e plugs M25 and with four ring screw M8 (pendant version). TECHNICAL DATA Certificate: Marking: 0722 EXA 13 ATEX 0014, EAC RU C-HR.AB24.B Apparatus category: II 2GD, I M2 (type PSF 218) Marking of explosion protection: Ambient temperature: Ex d e mb IIC T4 Gb Ex tb IIIC T80 C Db, Ex d e mb l Mb -20ºC Ta +50ºC [ATEX] -50ºC Ta +40ºC [EAC] Degree of protection: IP 66, category 1 Resistance to shock: IK 08 Protection class : I (protective earthing) Rated voltage: V (±10%) Frequency: Power factor: 50/60 Hz =0,95 Ballast lumen factor: 98% Light output ratio: η=0,72% - 0,78% End of life switch: Estimated service life: Connecting terminals: Cable entry: Through wiring: Packing: The electronic ballast, type SMP 07/12 fulfills the requirements according to IEC (simulation of the "end of life effect" of fluorescent lamps h at T amb =40 C L1, L2, L3, N, PE - max. 2,5 mm2 Two entries Ex e M25x1,5 for cable diameters Ø6-15 mm, and two Ex e plugs 3 x 2,5 mm 2, max. 16 A, or looping of the cables (entry and exit on one side) The packing contains: 1 pcs PSF 218 : 825x270x210 mm PSF 236 : 1420x270x210 mm PSF 258 : 1700x270x210 mm 28 make your work surroundings safer

29 Fluorescent light fitting MODEL CODE Model code PSF 218 Max. Wattage 2x18 W Lamp type Nominal voltage Luminous flux [lm] 2 x 1350 Lamp holder Nominal operational current Weight 0,18 A 7,5 kg PSF 236 2x36 W T V 2 x 3350 G13 0,33 A 10 kg PSF 258 2x58W 2x ,5 A 12 kg POLAR CURVE MOUNTING Pendant, on pipe, wall, ceiling DIMENSION DRAWING (all dimensions in mm) 200 L1 130 L1 [mm] L2 [mm] M8 M25 PSF PSF PSF L2 SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Diffuser PSF PSF PSF Ex e cable gland SPU 25 SPU 25 Gasket PSF PSF PSF Ex e plug M25 SPC 25 Internal reflector with lamp holder PSF PSF PSF PSF Ceiling mounting set PSF El. ballast SMP SMP 07/12 SMP 08 (PSF 258) PSF Pipe mounting set PSF Terminals 5x2,5mm 2 PSF PSF Wall mounting set PSF Socket key SW8 PSF Ring bolt M8 PSF All technical data is relevant at the time of print. 29

30 Zone PSF E G13 IP 66 C CONSTRUCTION 1,5 or 3h autonomy Maintained / Non maintained operation Ni-Mh battery Housing: SMC polyester plastic reinforced with glass fiber Diffuser: PC polycarbonate plastic Gasket: EPDM formed gasket Central locking: can be opened/closed using a socket key SW8, hinged lamp cover The light fitting is normally supplied without light sources, with socket key, two Ex e cable glands M25, two Ex e plugs M25 and with four ring screw M8 (pendant version). TECHNICAL DATA Certificate: EXA 13 ATEX 0014/3 Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2GD Ex db eb mb IIC T4 Gb Ex tb IIIC T80 C Db -20ºC Ta +40ºC Degree of protection: IP 66, category 1 Resistance to shock: IK 08 Protection class : I (protective earthing) Rated voltage: V (±10%) Frequency: Power factor: 50/60 Hz =0,95 Ballast lumen factor: 98% Light output ratio: Battery: Nominal autonomy: Connecting terminals: Cable entry: Piktogram: Packing: η=0,78% PSF 218E - Ni-Mh Saft VHT D, 4,8V 6Ah PSF 236E - Ni-Mh Saft VHT F, 4,8V 10Ah 1,5 / 3 hours L1, L2, L3, N, PE - max. 2,5 mm2 Two entries Ex e M25x1,5 for cable diameters Ø6-15 mm, and two Ex e plugs 300x150mm The packing contains: 1 pcs PSF 236 : 1420x270x210 mm PSF 218 : 825x270x210 mm 30 make your work surroundings safer

31 MODEL CODE Model code POLAR CURVE Max. Wattage Lamp type Emergency fluorescent light fitting Nominal voltage Luminous flux [lm] Luminos flux bat. mod [lm] MOUNTING Lamp holder Nominal operational current Weight 1,5h 60% (800lm) PSF 218 2x18 W 2 x ,18 A 9,0 kg h 40% (550lm) T8 G13 V 1,5h 60% (2000lm) PSF 236 2x36 W 2 x ,33 A 12,5 kg 3h 30% (1000lm) Pendant, on pipe, wall, ceiling DIMENSION DRAWING (all dimensions in mm) 200 L1 130 M8 M25 L1 [mm] L2 [mm] PSF 218 E PSF 236 E L2 SPARE PARTS AND ACCESSORIES All technical data is relevant at the time of print. 31

32 Zone G11 22 FLX IP 66 C CONSTRUCTION TC-L fluorescent compact lamps V AC/DC 0-60 Hz Housing: aluminium, corrosion resistant grey polyurethanes painted Diffuser: borosilicate glass tube Gasket: silicon The light fitting is normally supplied with two light sources, two entries M20 and wall/sealing mounting set. TECHNICAL DATA Certificate: CESI 06 ATEX /09, EAC RU C-HR.AB24.B Marking: Apparatus category: 0722 II 2GD Ex de IIC T5/T6 Gb Ex td A21 IP66 T95 C/T80 C Marking of explosion protection: Ambient temperature: -20ºC Ta +50ºC [ATEX] -50ºC Ta +50ºC [EAC] Degree of protection: IP 66, category 1 Resistance to shock: IK 08 Protection class : I (protective earthing) Rated voltage: 100 V 280 V AC/DC Frequency: 0-60 Hz Rated power: See model code table Ballast lumen factor: 98% Light output ratio: η=0,73% Connecting terminals: Cable entry: 32 L1, L2, L3, N, PE - max. 2,5 mm2 PE for outside earthing max. 2 x 6 mm2 2 x M20 2 x 3/4"NPT 2 x M20, with one Ex d plugs and one adapter type ADP 03/24, for cable 6-15 mm Through wiring: With two Ex de adapter ADP 03/24-4 x 2,5 mm2, max. 16 A, Energy classification EEI: A2 Electromagnetic compatibility: in conformity with the EMC Directive 2004/108 EC and harmonized standards EN A1+A2, EN 61547, EN A1, EN make your work surroundings safer

33 Fluorescent light fitting MODEL CODE Model code Max. Wattage Lamp type Nominal voltage Luminous flux [lm] Lamp holder A B Weight FLX 218 2x18 W 2 x ,3 kg FLX 236 2x36 W TC-L V 2 x G ,8 kg FLX 255 2x55 W 2 x ,4 kg POLAR CURVE DIMENSION DRAWING (all dimensions in mm) B A MOUNTING Pendant, on pipe, wall, ceiling mounting. Operates in any position. All technical data is relevant at the time of print. 33

34 Zone FLX SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Cover gasket FLX FLX Ex d cable gland SPU 20 SPU 20 Base plate FLX/... FLX Ex d plug M20 SPC 20 Protective grid FLX set FLX FLX Wall / ceiling mounting set FLX External reflector FLX FLX FLX Pipe mounting set FLX Adapter ADP 23 FLX make your work surroundings safer

35 Fluorescent light fitting 35

36 Zone FLXE 118 LED IP 66 C Used for marking escape routes and exits in potentially explosive atmospheres. Self-test, monitoring and diagnostics reduce costly maintenance checks. >3h autonomy Maintained / Non maintained operation Possibility of supplies with DALI compatible ballast Ni-MH 3,6V/2.2Ah, build in light fitting, microprocessor controlled charging, discharging and control of battery CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass tube, Gasket: silicon The light fitting is normally supplied with two entries M20 and wall/sealing mounting set TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: EXA 15 ATEX 0001X EAC RU C-HR.AB24.B II 2G II 2D Ex d e IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +40ºC /+50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: I (protective earthing) V 110V on request 50Hz / 60Hz Rated power: 2x 1,2W Connecting terminals: Cable entry: Weight: MOUNTING L1, L2, L3, N; max. 2 x 2,5 mm2 PE terminal ; max 2x6mm2 External PA terminal -PA; max 2x6mm2 2 x M20 or 2 x 3/4"NPT or 2 x M20, with one Ex d plugs and one adapter type ADP 03/24 for cable 6-15 mm 4kg Pendant, on pipe, wall, ceiling mounting. Operates in any position. 36 make your work surroundings safer

37 Emergency LED light fitting MODEL CODE The lamp can operate with two types of connection: a) Maintained (Dauerschaltung) The light fitting can be used for general and orientation lighting with mains power supply via L' (installation switch). In case of voltage drop or an interruption in the mains power supply L, the light fitting will continue to operate in battery-powered mode, regardless of the status of installation switch L' (ON/OFF). b) Non maintained (Bereitschaftschaltung) In case of voltage drop or an interruption in the mains power supply L, the light fitting will operate only in batterypowered mode. In both types of the connection in the presence of continuous phase L, it is possible to verify the correctness of the emergency system by turning on the switch in the TEST circuit. ISOCANDELA CURVE [l/cd] DIMENSION DRAWING ±1 220±1 160±0,5 O13 180±0,5 SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Cover gasket FLX FLX External reflector FLX FLX LED Base plate FLXE FLXE FLX Wall / ceiling mounting set FLX Protective grid FLXE set FLXE FLX Pipe mounting set FLX All technical data is relevant at the time of print. 37

38 Zone SIF G13 IP 66 C T8 fluorescent lamps in parallel configuration Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply Recessed mounting set for clear rooms CONSTRUCTION Housing: Epoxi/polyester powder-coated sheet steel Diffuser: flat borosilicate glass with a high thermal and mechanical stability Gasket: EPDM formed gasket All-pole are disconnected via NC switch when glass cover is opened. The light fitting is normally supplied without light sources, two Ex e cable glands M25, one Ex e plug M25 and with two ring screw M8 (pendant version). TECHNICAL DATA Certificate: EXA 13 ATEX 0015 Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2GD -30ºC Ta +50ºC Degree of protection: IP 66, category 1 Resistance to shock: IK 08 Protection class : Ex d e mb IIC T4 Gb Ex tb IIIC T80 C Db I (protective earthing) Rated voltage: V (±10%) Frequency: Power factor: 50/60 Hz =0,95 Ballast lumen factor: 98% Light output ratio: End of life switch: Estimated service life: η=0,72% The electronic ballast, type SMP 07/12 fulfills the requirements according to IEC (simulation of the "end of life effect" of fluorescent lamps h at T amb =40 C Connecting terminals: Cable entry: Through wiring: Disconnection of the light: Packing: L1, L2, L3, N, PE - max. 2,5 mm2 Two entries Ex e M25x1,5 for cable diameters Ø6-15 mm, and two Ex e plugs 5x terminals 4x4 mm 2, max. 16 A, or looping of the cables (entry and exit on one side) Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. The packing contains: 1 pcs 142X415X140 mm 38 make your work surroundings safer

39 Fluorescent light fitting MODEL CODE Model code Max. Wattage Lamp type Nominal voltage Luminous flux [lm] Lamp holder Nominal operational current Weight SIF 236 2x36 W 2 x ,18 A 25 kg T V G13 SIF 436 4x36 W 4 x ,33 A 27 kg POLAR CURVE RECESSED LIGHT FITTING MOUNTING (Pendant, wall/ceiling mounting, recessed ) MOUNTING (Pendant, wall/ceiling mounting, recessed ) SPARE PARTS AND ACCESSORIES Sketch Description Code Sketch Description Code Gasket SIF SIF Ex e cable gland SPU 25 SPU 25 El. ballast SMP 07/12 SMP 06/12 Ex e plug M25 SPC 25 Ring bolt M8 - All technical data is relevant at the time of print. 39

40 Zone LED20 IP 66 C Application in confined or restricted spaces Robust light alloy enclosure weighs only 4 kg Allowing the user to mount in areas where the available space is restricted Fast and easy installation Estimated service life hours CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass, silicone gasket Protected grid: AISI 316 Standard version without protected grid TECHNICAL DATA Certificate: EXA 16 ATEX 0015 Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2G II 2D Ex eb mb IIC T6 Gb Ex tb IIIC T80 C Db -30ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Connecting terminals: Cable entry: I (protective earthing) 230 V 50Hz (60Hz on request) 20 W terminals L1 + N for 2 x 4 mm ² terminals PE for 2 x 4 mm ² 2x M25 (1x M25 Exe cable gland, 1x Exe M25 plug) Weight: Packing: 4 kg The packing contains: 1 pcs 360x240x205 mm MOUNTING Two brackets with two screws M6 40 make your work surroundings safer

41 Bulkhead LED light fitting MODEL CODE MODEL CODE LED power [W] VOLTAGE [V] LUMINOUS FLUX [lm] LIGHT OUTPUT RATIO LED W 230V ,80 POLAR CURVE DIMENSION DRAWING (all dimensions in mm) SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE LEDEx 01 modul LED Ex e cable gland M25 SPU 25 Gasket LED LED Ex e plug M25 SPC 25 Glass cover LED Bracket for wall LED Protective grid LED Bracket for pipe R LED Example of equivalent "traditional" light sources with Ex LED LED LED 20 A - incandescent light bulb /10 20W 100 lm/w 100W 15 lm/w The given information is for rough orientation only. In each individual case a lighting calculation is necessary. All technical data is relevant at the time of print. 41

42 Zone PLFM LED IP 66 C Robust light alloy enclosure weighs only 3,5 kg Fast and easy installation PLFM 100/3 with E27 lampholder for LED bulb Estimated service life for LED module 20W ~ h LED module with 100lm/W CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass Accessories: protected galvanized steel gird (INOX on request), assembly kit for wall, pipe and ceiling mounting Standard version without protected grid TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: EXA 14 ATEX 0056X II 2G II 2D Ex d e IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +40ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Connecting terminals: Cable entry: Weight: Packing: I (protective earthing) 230 V 50Hz (60Hz on request) 12W, 20 W terminals L1 + N for 2 x 4 mm ² terminals PE for 2 x 4 mm ² 2x M20 (1x M20 Ex de adapter ADP 23/1 for cable 7-15mm, 1x Exd M20 plug) 3,5 kg The packing contains: 2 pcs 440x260x170mm MOUNTING Pendant, on pipe, wall, ceiling 42 make your work surroundings safer

43 Pendant LED light fitting MODEL CODE MODEL CODE LED power [W] VOLTAGE [V] 12 W Osram 13 W Philips LUMINOUS FLUX [lm] PLFM 100/ V PLFM 20 LED LED module 2000 LIGHT OUTPUT RATIO 0,80 POLAR CURVE DIMENSION DRAWING LED module 20W, 2000 lm Master LEDbulb Osram 12W, 810 lm SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Replacement glass PLFM PLFM Ex d metal plug M20 SPC 20 Wire guard PLFM PLFM LED bulb E27 prema tablici izvedbi Gasket PLFM PLFM PLFM LED modul, set PLFM Adapter ADP 23/1 PLFM Example of equivalent "traditional" light sources with Ex LED PLFM mounting bracket for pipe R2 PLFM mounting bracket (ceiling) PLFM mounting bracket (wall) PLFM PLFM PLFM LED QT (halogen) CFL (compact fluo) PLFM 20 LED PLFM 100 QT PLFM 100/2 17W 100 lm/w 100W 18 lm/w 23W 65 lm/w The given information is for rough orientation only. In each individual case a lighting calculation is necessary. All technical data is relevant at the time of print. 43

44 Zone LED 30 IP 66 C Robust light alloy enclosure weighs only 3,8 kg Estimated service life hours LED module with 100lm/W CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass, Accessories: assembly kit for wall, pipe and ceiling mounting TECHNICAL DATA Certificate: In progress Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2G II 2D Ex d e IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +40ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Connecting terminals: Cable entry: Weight: MOUNTING Pendant, on pipe, wall, ceiling I (protective earthing) 230 V 50Hz (60Hz on request) 30 W terminals L1 + N for 2 x 4 mm ² terminals PE for 2 x 4 mm ² 2x M25 (1x M25 Ex e cable gland for cable 7-15mm, 1x Exe M25 plug) 3,8 kg 44 make your work surroundings safer

45 Pendant LED light fitting MODEL CODE MODEL CODE LED power [W] VOLTAGE [V] LUMINOUS FLUX [lm] LIGHT OUTPUT LED W 230V ,84 DIMENSION DRAWING 248±1 POLAR CURVE RATIO 246±1 LED module 30W, 2850 lm SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE Replacement glass LED LED module 30W SKETCH DESCRIPTION CODE LED Ex e cable gland M25 SPU LED Gasket LED Example of equivalent "traditional" light sources with Ex LED LED HME (mercury) LED 30 PLFS-T 30W 95 lm/w HIE (metal halide) PLFS-T W 50 lm/w QT (halogen) PLFS-T W 80 lm/w 230W 18 lm/w The given information is for rough orientation only. In each individual case a lighting calculation is necessary. All technical data is relevant at the time of print. 45

46 Zone PLFS 50 LED IP 66 C Highest efficiency with luminous efficacy up to 170lm/ W High colour rendering index CRI 80 Estimated service life hours With OVP, OCP, OTP protection Autonomous reactivation after recovery CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass, Accessories: protected galvanized steel gird, assembly kit for wall, pipe and ceiling mounting Gasket: silicon TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature ATEX: EAC: EXA 14 ATEX 0028 EAC RU C-HR.AB24.B II 2G II 2D Ex d e IIC T6/T5 Gb Ex tb IIIC T80 C/T85 C Db -40ºC T a +40ºC /+50ºC -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Connecting terminals: Cable entry: Weight: Packing: MOUNTING I (protective earthing) V AC V DC 50Hz / 60Hz 35W, 50W, 60W, 80W L1, L2, L3, N; max. 2 x 2,5 mm2 PE terminal ; max 2x6mm2 External PA terminal -PA; max 2x6mm2 2x M25 (1x M25 Ex e cable gland for cable 7-15mm, 1x Exe M25 plug) 6,8kg (PLFS 50 LED-4-11kg) The packing contains: 2 pcs 560 x 270 x 270 mm Pendant, on pipe, wall, ceiling, recessed (clean room LED light fitting) 46 make your work surroundings safer

47 Pendant LED light fitting MODEL CODE MODEL CODE LED power [W] PLFS 50 LED-1 35 W PLFS 50 LED-2 50 W PLFS 50 LED-3 60 W PLFS 50 LED-4 80 W VOLTAGE [V] LUMINOUS FLUX [lm] LIGHT OUTPUT RATIO C +50 C V AC V DC AMBIENT TEMP. 0, C +40 C POLAR CURVE DIMENSION DRAWING PLFS 50 LED-1, -2, -3 PLFS 50 LED-4 x HR ZAGREB PLFS-T/LED HREx ATEX T VAC, VDC 50 W max. II 2G Ex de IIC T6 Gb -20 ta +50 C II 2D Ex tb IIIC T80 C Db IP 66 P- AZ - WARNING - DO NOT OPEN WHEN ENERGIZED SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE Replacement glass PLFS LED Wire guard PLFS LED SKETCH DESCRIPTION CODE PLFS LED PLFS-T fixing bracket for tube R 1 1/2 PLFS PLFS LED PLFS-T mounting bracket (ceiling and PLFS wall mounting) Example of equivalent "traditional" light sources with Ex LED LED HME (mercury)) PLFS 50 LED-1 PLFS-T W 170 lm/w PLFS 50 LED-3 60W 170 lm/w PLFS-T 150 HIE 80W 170 lm/w 230W QT 18 lm/w PLFL W 80 lm/w 250W 52 lm/w PLFL 400 HME QT (halogen) / A PLFS-T W 80 lm/w 125W 50 lm/w PLFL 250 HME PLFS 50 LED-4 HIE (metal halide) PLFS-T W A 15 lm/w PLFL 250 HIE 400W 50 lm/w 250W 80 lm/w The given information is for rough orientation only. In each individual case a lighting calculation is necessary. All technical data is relevant at the time of print. 47

48 Zone FLX 310 LED IP 66 C High colour rendering index CRI >80 Estimated service life working hours at tamb = 40 C LED 3 x 12W chip -on-board technology with OVP, OCP, OTP protection Autonomous activation after recovery Suitable for linear lighting up to 20 modules CONSTRUCTION Housing: aluminium powder painted casting Diffuser: borosilicate glass tube, Gasket: silicon The light fitting is normally supplied with three LED linear sources, two entries M20 and wall/ sealing mounting set TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: EXA 15 ATEX 0050X II 2G II 2D Ex d e IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +40ºC /+50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Connecting terminals: Cable entry: Weight: Packing: I (protective earthing) V 110V on request 50Hz / 60Hz 3x 12W L1, L2, L3, N; max. 2 x 2,5 mm2 PE terminal ; max 2x6mm2 External PA terminal -PA; max 2x6mm2 2 x M20 or 2 x 3/4"NPT or 2 x M20, with one Ex d plugs and one adapter type ADP 03/24 for cable 6-15 mm 7kg The packing contains: 1 pcs 540x230x200 mm MOUNTING Pendant, on pipe, wall, ceiling mounting. Operates in any position. 48 make your work surroundings safer

49 Linear LED light fitting MODEL CODE MODEL CODE LED power [W] VOLTAGE [V] LUMINOUS FLUX [lm] LIGHT OUTPUT RATIO AMBIENT TEMP. FLX 310 LED 36W V ,85-20 C +40 C POLAR CURVE DIMENSION DRAWING SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Cover gasket FLX FLX External reflector FLX FLX LED LED module FLX 310 FLX LED FLX Wall / ceiling mounting set FLX Protective grid FLX set FLX LED FLX Pipe mounting set FLX All technical data is relevant at the time of print. 49

50 Zone PSF LED IP 66 C CONSTRUCTION Central locking with internal switch Through-wiring possible LED modules with innovative encapsulation Estimated service life up to hours High color rendering index CRI 80 Luminous efficacy 154lm/W With OVP, OCP, OTP protection Autonomous reactivation after recovery Housing: SMC polyester plastic reinforced with glass fiber, color RAL 7038 Diffuser: PC polycarbonate plastic Gasket: silicone Central locking: can be opened/closed using a socket key SW8, hinged lamp cover The light fitting is normally supplied with socket key, two Ex e cable glands M25, two Ex e plugs M25 and with mounting set PSF TECHNICAL DATA Certificate: In progress Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: II 2G II 2D Ex db eb mb IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +55ºC -20ºC T a +40ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Frequency: Rated power: Estimated service life: Connecting terminals: Cable entry: Disconnection of the light: Packing: I (protective earthing) VAC VDC Hz See model code table PSF 28 LED-1, PSF 52 LED hours PSF 28 LED-2, PSF 52 LED hours L1, L2, L3, N, PE - max. 2,5 mm2 Two entries Ex e M25x1,5 for cable diameters Ø6-15 mm, and two Ex e plugs Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. The packing contains: 1 pcs PSF 52 LED: 1420x270x210 mm PSF 28 LED: 825x270x210 mm MOUNTING Pendant, on pipe, wall, ceiling 50 make your work surroundings safer

51 MODEL CODE MODEL CODE LED power [W] VOLTAGE [V] LUMINOUS FLUX [lm] Linear LED light fitting LIGHT OUT- PUT RATIO AMBIENT TEMP. WEIGHT PSF 28 LED-1 26 W 4700 lm 7,0 kg VAC 0,84-20ºC T VDC a +55ºC PSF 52 LED-1 48 W 7400 lm 10,0 kg Special types for the ambient temperature -20ºC Ta +40ºC and higher LED power. PSF 28 LED-2 34 W 5650 lm 7,0 kg VAC 0,84-20ºC T VDC a +40ºC PSF 52 LED-2 64 W 9150 lm 10,0 kg POLAR CURVE DIMENSION DRAWING (all dimensions in mm) TYPE PSF LED 28-1 PSF LED 28-2 PSF LED 52-1 PSF LED 52-2 L1 [mm] L2 [mm] L1 130 M25 M8 λ = 84% L2 SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Diffuser PSF PSF LED PSF LED Ex e cable gland SPU 25 SPU 25 Gasket PSF PSF LED PSF LED Ex e plug M25 SPC 25 Internal reflector with LED module PSF LED PSF LED PSF Ceiling mounting set PSF LED driver PSF LED 28 drive PSF LED 52 drive PSF Pipe mounting set PSF Terminals 5x2,5mm 2 PSF PSF Wall mounting set PSF Socket key SW8 PSF Ring bolt M8 PSF All technical data is relevant at the time of print. 51

52 NOTES

53 Installation equipment

54 Zone 1 2 SKX SW IP 66 C Enclosure made of glass-fibre reinforced polyester resin 2 pole OFF switch or changeover switch CONSTRUCTION Enclosure: polyester plastic reinforced with glass fiber, color - black Cover: with integrated thermoplastic elastomer gasket, closes with four M5 stainless steel screws. TECHNICAL DATA Certificate: EXA 15 ATEX 0006X Marking: 0722 Apparatus category: II 2G Marking of explosion protection: Ex d e IIC T6 Gb Ambient temperature ATEX: -20ºC T a +40/+50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated isolating voltage: Thermal current I the : PE terminals (inside of the enclosure): Weight: I (protective earthing) 690 V 16 A for -20 C Ta +40 C 15 A for -20 C Ta +50 C max. 2x4 mm2+2x2,5 mm2, 3x4 mm2, 2x6 mm2 App. 0,6kg 54 make your work surroundings safer

55 Installation switch MODEL CODE Installation switches SKX - SW /. basic type code type of switches 1 - on-off switch 1 pole 2 - on-off switch 2 pole 6 - changeover switch Switching capacity Rated operating voltage Ue Rated operating current Ie AC 5a 230 V 16 A for -20 C Ta +40 C 15 A for -20 C Ta +50 C AC 5b 230 V 16 A for -20 C Ta +40 C 15 A for -20 C Ta +50 C AC V 16 A for -20 C Ta +40 C 15 A for -20 C Ta +50 C AC V 500 V 6 A for -20 C Ta +50 C 4 A for -20 C Ta +50 C DC V 60 V 110 V 6 A for -20 C Ta +50 C 0,8 A for -20 C Ta +50 C 0,5 A for -20 C Ta +50 C WIRING DIAGRAM ON-OFF switch 1 pole ON-OFF switch 2 pole Changeover switch DIMENSION MOUNTING 111± ± All technical data is relevant at the time of print. 55

56 Zone RK IP 66 C Enclosures made of PA glass fiber reinforced polyamide The cover screws and all other external metal parts are made of stainless steel (AISI 316L) Equipped with terminals up to 6mm 2 Pillar (mantle) terminals CONSTRUCTION Enclosure: PA glass fiber reinforced polyamide, color - black Cover: PA glass fiber reinforced polyamide with integrated thermoplastic elastomer gasket, closes with four M5 stainless steel screws. TECHNICAL DATA Certificate: Marking: 0722 CESI 10 ATEX 040, RU C-HR.AB24.B Apparatus category: II 2G II 2D Marking of explosion protection: Ex e II T6 Ex ia/ib IIC T6 Ex td A21 T80 C Ambient temperature ATEX: EAC: -20ºC T a +50ºC, -20ºC T a +70ºC for Exi -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Maximum voltage for Ex i: I (protective earthing) 630 V 60 V Maximum current of terminals : Cable entries, cable glands and screw plugs: PE terminals (inside of the enclosure): Weight: Packing: MOUNTING 6 x M25 for cable 6-15 mm ( mm available on request) 6 x M32 for cable mm ( mm available on request) 4 x M25 for cable 6-15 mm ( mm available on request) 4 x M32 for cable mm ( mm available on request) max. 2x4 mm 2 +2x2,5 mm 2, 3x4 mm 2, 2x6 mm 2 0,55 kg The packing contains: 14 pcs 435x260x220 mm With two screws through the housing holes 6 mm at the peaks the rectangle: 100 x 75 mm 56 make your work surroundings safer

57 Junction box MODEL CODE TYPE DESIGN CABLE GLANDS NUMBER OF TERMINALS MAX. CAPACITY PER TERMINAL RK 01/ x 4mm 2 (L1, L2, L3, N, PE) RK01/514 Ex i cable glands 4xM25 for cable 6-15mm, 2xM25 screw plug 5-1 x 4mm 2 (Blue 1-5) 1x0,5...4mm 2 2x0,5...2,5mm 2 RK 01/ x 6mm 2 (L1, L2, L3, N, PE) 1x1,5...6mm 2 2x1,5...4mm 2 RK 01/544 cable glands 4xM25 for cable 6-15mm 5-4 x 4mm 2 cable glands 6xM25 RK 01/744 for cable 6-15mm 7-4 x 4mm 2 RK 01/544-E 2 x M32 cable glands for armoured cable Ø v 23-32mm 4 x M25 cable glands for armoured cable Ø v 17-23mm 5-4x 4mm 2 4x4mm 2 6x2,5mm 2 1x4mm 2 + 2x2,5mm x1,5mm 2 1x4mm 2 + 5x1,5mm 2 2x4mm 2 + 3x2,5mm 2 Other configuration available on request DIMENSION WARNING DO NOT OPEN WHEN ENERGIZED O HR Zagreb 0722 RK/054 Ui=690V CESI 09 ATEX... II 2G Ex e II T6 II 2D Ex A21 IP66 T80 C P- AZ All technical data is relevant at the time of print. 57

58 Zone JBX IP 66 C Ex d enclosure made of saltwaterresistant, copperfree aluminium cast alloy In terminal box versions standard cable glands without compund can be used CONSTRUCTION Enclosure: corrosion resistant grey polyurethanes painted aluminium color RAL 7000 Gasket: Silicon TECHNICAL DATA Certificate: EXA 13 ATEX 0003U/1, lecex EXA U Marking: 0722 Apparatus category: II 2G II 2D Marking of explosion protection: Ex d IIC Gb Ex tb IIIC Db Ambient temperature: Service temperature: -20ºC T a +60ºC -20ºC T a +80ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : I (protective earthing) External earthing terminal: max. 2 x 6 mm 2 Weight: 0,95 kg MOUNTING With two screws M6 x 20mm on distance 123 mm 58 make your work surroundings safer

59 Junction box MODEL CODE DIMENSION TYPE No. of entries/side Entries JBX 01/11 JBX 01/12 JBX 01/13 JBX 01/31 JBX 01/32 JBX 01/33 JBX 01/41 JBX 01/42 JBX 01/43 2 / B-D 3 / B-C-D 4 / A-B-C-D 2 / B-D 3 / B-C-D 4 / A-B-C-D 2 / B-D 3 / B-C-D 4 / A-B-C-D M20x1,5 - ISO 261 3/4 - NPT - ANSI ASME B /2 - NPT - ANSI ASME B All technical data is relevant at the time of print. 59

60 Zone SKX../E IP 66 C Enclosures in shock-resistant glass fibre reinforced polyester resin 7 basic enclosure sizes Fitted according to the customer's requirements CONSTRUCTION Enclosure: SMC glass fiber reinforced polyamide, color - black Cover: SMC glass fiber reinforced polyamide with integrated thermoplastic elastomer gasket, closes with four M5/M6 stainless steel screws. TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature ATEX: EAC: EXA 15 ATEX 0044, EXA 16 ATEX 0047 EAC RU C-HR.AB24.B II 2G II 2D Ex eb llc TG Gb Ex ia/ib llc TO Gb Ex eb ia/ib llc T6 cb Ex tb lllc T80'C Db -20ºC T a +50ºC -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Nominal current: Maximum safe voltage U m for intrinsically safe circuits Exi: Cable entries, cable glands and screw plugs: I (protective earthing) 630 V Up to 125 A (depend on size and number of terminals) 60 V 6 x M25 for cable f6-15 mm (f13-19 mm available on request) 6 x M32 for cable f12-21 mm (f17-25 mm available on request) 4 x M25 for cable f6-15 mm (f13-19 mm available on request) 4 x M32 for cable f12-21 mm (f17-25 mm available on request) PE terminals (inside of the enclosure): max. 2x4 mm 2 +2x2,5 mm 2, 3x4 mm 2, 2x6 mm 2 N/PE rails inside the enclosure: 2 pcs, 11 terminals 2x4mm 2 max. Weight (without cable glands): SKX 12/E kg SKX 13/E... 0,7kg SKX 14/E kg SKX 15/E ,5kg SKX 16/E... 3,5kg SKX 18/E... 4,5kg SKX 20/E... 7,0kg MOUNTING With two/four screws through the housing holes 6 mm at the peaks the rectangle: SKX 12: 75 x 50 mm SKX 16: 235 x 200 mm SKX 13: 75 x 100 mm SKX 18: 380 x 200 mm SKX 14: 75 x 150 mm SKX 20: 580 x 200 mm SKX 15: 125 x 150 mm 60 make your work surroundings safer

61 Terminal box Terminal box SKX 12/E Nominal cross-section of conductor / terminal [mm 2 ] 4/4 Max. number of terminals Max.ambient temp Ta C Imax [A] C Max. number of mounted cable entries: Side Cable gland M16 M20 M25 D B A-C A B-D Terminal box SKX 13/E Nominal cross-section of conductor / terminal [mm 2 ] Max. number of terminals 4/4 8 6/6 Max.ambient temp Ta C Imax [A] C Max. number of mounted cable entries: D B Side Cable gland M16 M20 M25 A A-C B-D Terminal box SKX 14/E Nominal cross-section of conductor / terminal [mm 2 ] Max. number of terminals 4/4 16 6/6 Max.ambient temp Ta C Imax [A] C Max. number of mounted cable entries: D B Side Cable gland M16 M20 M25 M32 A-C B-D A All technical data is relevant at the time of print. 61

62 Zone Terminal box SKX 15/E SKX../E Table of permitted combinations of conductors on the principle of maximum rated losses (ambient temperature Ta 40 C) Nominal cross-section of conductor / terminal [mm 2 ] Maximum number of terminals Imax [A] 2,5/2, / / / / / / The maximum number of terminals specified by the measures of the terminal boxes 24 + busbar 22PE Width of terminal [mm] Allowed number of conductors per terminal 1x2.5-1 x mm 2 mm 2 1 x6-1.5 mm 2 1 x mm 2 1 x x x 35-6 mm 2 mm 2 mm 2 Width of PE terminal [mm] Width of final terminal [mm] 9 Space for a terminal on DIN rail without end terminals 1) Two conductors are connected on one terminal 2) PE conductors and jumpers are not taken in the calculation max. 140 mm It is possible to connect on one terminal smaller nominal cross-section conductors, but the maximum number of conductors and maximum current for the nominal wire size must be respected according to Table of permitted installation. Combination of many different nominal cross-section terminals and conductors in one terminal box is allowed. Possible combinations are calculated on the basis of the Table of permitted installation so that the total maximum losses and the possibility of a physical installation is possible. 62 make your work surroundings safer

63 Terminal box Max. number of mounted cable entries: DIMENSIONS [mm] Side Cable gland M16 M20 M25 M32 M40 A-C B-D Side Cable gland M16 M20 M25 M32 M40 C A-C B-D *with N/PE rails D B A 63

64 Zone Terminal box SKX 16/E Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) SKX../E Maximum number of terminals 2,5 / 2,5 70 Ambient temperature Ta[ C] Imax [A] 2,5 / 2, C do +40 C 13 2,5 / 2, ,5 / 2,5 70 2,5 / 2, C do +50 C 11 2,5 / 2, / / C do +40 C 18 4 / / / C do +50 C 16 4 / / / C do +40 C 26 6 / / / C do +50 C 22 6 / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / C do +40 C 50 / / C do +50 C 50 / make your work surroundings safer

65 Terminal box Max. number of mounted cable entries: DIMENSIONS [mm] Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C

66 Zone Terminal box SKX 18/E Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) SKX../E Maximum number of terminals 2,5 / 2,5 180 Ambient temperature Ta[ C] Imax [A] 2,5 / 2, C do +40 C 12 2,5 / 2, ,5 / 2, ,5 / 2, C do +50 C 10 2,5 / 2, / / C do +40 C 16 4 / / / C do +50 C 14 4 / / / C do +40 C 23 6 / / / C do +50 C 20 6 / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / make your work surroundings safer

67 Terminal box Max. number of mounted cable entries: DIMENSIONS [mm] Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C

68 Zone Terminal box SKX 20/E SKX../E Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) minals Maximum number of ter- 2,5 / 2,5 200 Ambient temperature Ta[ C] Imax [A] 2,5 / 2, C do +40 C 2,5 / 2, ,5 / 2, ,5 / 2, ,5 / 2, C do +50 C 10 2,5 / 2, / / C do +40 C 4 / / / / C do +50 C 14 4 / / / C do +40 C 23 6 / / / C do +50 C 20 6 / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / make your work surroundings safer

69 Terminal box Max. number of mounted cable entries: DIMENSIONS [mm] Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C

70 Zone SKX..I/E IP 66 C Enclosures in stainless steel AISI 316L 3 basic enclosure sizes Fitted according to the customer's requirements CONSTRUCTION Enclosure: Stainless steel AISI 316L, brush finished, thickness 1.5mm Cover: with integrated thermoplastic elastomer gasket, closes with four M5 stainless steel screws. TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature ATEX: EAC: EXA 16 ATEX 0047 EAC RU C-HR.AB24.B II 2G II 2D Ex eb llc TG Gb Ex ia/ib llc TO Gb Ex eb ia/ib llc T6 cb Ex tb lllc T80'C Db -20ºC T a +50ºC -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Nominal current: Maximum safe voltage U m for intrinsically safe circuits Exi: Cable entries, cable glands and screw plugs: I (protective earthing) 630 V Up to 125 A (depend on size and number of terminals) 60 V 6 x M25 for cable f6-15 mm (f13-19 mm available on request) 6 x M32 for cable f12-21 mm (f17-25 mm available on request) 4 x M25 for cable f6-15 mm (f13-19 mm available on request) 4 x M32 for cable f12-21 mm (f17-25 mm available on request) PE terminals (inside of the enclosure): max. 2x4 mm 2 +2x2,5 mm 2, 3x4 mm 2, 2x6 mm 2 N/PE rails inside the enclosure: 2 pcs, 11 terminals 2x4mm 2 max. Weight (without cable glands): SKX 16I/E 3,1 kg SKX 18I/E-1. 4,8 kg SKX 18I/E-2 5,4 kg SKX 20I/E 5,6 kg MOUNTING With four screws through the housing holes 8 mm at the peaks the rectangle: 70 make your work surroundings safer

71 Terminal box Stainless steel terminal box SKX 16I/E, SKX 18I/E-1, SKX 18I/E-2, SKX 20 I Type A[mm] B[mm] C[mm] SKX 16I/E SKX 18I/E SKX 18I/E SKX 20I/E MOUNTING Type D[mm] E[mm] F[mm] G[mm] SKX 16I/E SKX 18I/E SKX 18I/E SKX 20I/E Max. number of mounted cable entries: TYPE Dimension Cable gland SKX 16I/E 300X200X120 SKX 18I/E-1 400X200X120 SKX 18I/E-2 400X300X120 SKX 20I/E 600X200X120 A-C B-D A-C B-D A-C B-D A-C B-D M20x M25x M32x M40x M50x M60x D A B C All technical data is relevant at the time of print. 71

72 Zone SKX..I/E Terminal box SKX 16I/E (300x200x120 mm) Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) Maximum number of terminals 2,5 / 2,5 60 Ambient temperature Ta[ C] Imax [A] 2,5 / 2, C do +40 C 13 2,5 / 2, ,5 / 2,5 60 2,5 / 2, C do +50 C 11 2,5 / 2, / / C do +40 C 18 4 / / / C do +50 C 16 4 / / / C do +40 C 26 6 / / / C do +50 C 22 6 / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / C do +40 C 50 / / C do +50 C 50 / make your work surroundings safer

73 Terminal box Maximum possible number of terminals definite by enclosure dimensions Maximum possible number of terminals definite by enclosure dimensions Width of single terminal [mm] Allowed cross-section of conductor for single terminal 1x mm 2 1 x4-1.5 mm 2 1 x6-1.5 mm 2 1 x mm 2 1 x mm 2 1 x 25-6 mm 2 1 x 35-6 mm 2 18,5 1 x mm2 Width of PE terminal [mm] Width of end holder 9 Space for terminals on DIN rail without end holders max. 214 mm 73

74 Zone SKX..I/E Terminal box SKX 18I/E-1 (400x200x120 mm), SKX 18I/E-2 (400x300x120 mm) Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) Maximum number of terminals Ambient temperature Ta[ C] Imax [A] 2,5 / 2, ,5 / 2, C do +40 C 12 2,5 / 2, ,5 / 2, ,5 / 2, C do +50 C 10 2,5 / 2, / / C do +40 C 16 4 / / / C do +50 C 14 4 / / / C do +40 C 23 6 / / / C do +50 C 20 6 / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / C do +40 C 50 / / / C do +40 C 50 / / make your work surroundings safer

75 Terminal box Maximum possible number of terminals definite by enclosure dimensions Maximum possible number of terminals definite by enclosure dimensions Width of single terminal [mm] Allowed cross-section of conductor for single terminal 1x mm 2 1 x4-1.5 mm 2 1 x6-1.5 mm 2 1 x mm 2 1 x mm 2 1 x 25-6 mm 2 Width of PE terminal [mm] Width of end holder 9 Space for terminals on DIN rail without end holders max. 300 mm 1 x 35-6 mm 2 18,5 1 x mm Ex terminal box SKX 18I/E-1 Ex terminal box SKX 18I/E

76 Zone SKX..I/E Terminal box SKX 18I/E-1 (400x200x120 mm) Table of allowed number of terminals Nominal cross section of conductors / terminals (mm2) Maximum number of terminals Ambient temperature Ta[ C] Imax [A] 2,5 / 2, ,5 / 2, C do +40 C 9 2,5 / 2, ,5 / 2, ,5 / 2, C do +40 C 8 2,5 / 2, ,5 / 2, / C do +50 C 9 4 / / / C do +40 C 23 4 / / / C do +50 C 20 6 / / / C do +40 C 34 6 / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / / C do +50 C / / / C do +40 C / / C do +50 C 35 / / / / C do +40 C 50 / / / make your work surroundings safer

77 Terminal box Maximum possible number of terminals definite by enclosure dimensions Maximum possible number of terminals definite by enclosure dimensions Width of single terminal [mm] ,5 Allowed cross-section of conductor for single terminal 1x mm 2 1 x4-1.5 mm 2 1 x6-1.5 mm 2 1 x mm 2 1 x mm 2 1 x 25-6 mm 2 1 x 35-6 mm 2 1 x mm2 Width of PE terminal [mm] ,5 Width of end holder 9 Space for terminals on DIN rail without end holders max. 500 mm Ex terminal box SKX 20I/E All technical data is relevant at the time of print. 77

78 NOTES

79 Control units

80 Zone SKX 12 SKX 15 IP 66 C Enclosures made of glass-fibre reinforced polyester resin 4 basic enclosure sizes Alone or in various combinations of merged set Equipped with built -in devices Control devices Indicating lamps Pushbuttons Control switches Ammeters CONSTRUCTION Enclosure: polyester plastic reinforced with glass fiber, color - black Cover: with integrated thermoplastic elastomer gasket, closes with four M5/M6 stainless steel screws. TECHNICAL DATA Certificate: Marking: 0722 CESI 12 ATEX 017X, EXA 13 ATEX 0029,, EAC RU C-HR.AB24.B Apparatus category: II 2GD II 2G Ex d e IIC T6 Gb II 2G Ex d e mb IIC T6 Gb Marking of explosion protection: II 2G Ex e IIC T6 Gb II 2G Ex ia/ib IIC T6 Gb II 2D Ex tb IIIC T80 C Db Ambient temperature ATEX: -20ºC T a +50ºC EAC: -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Thermal current I the : PE terminals (inside of the enclosure): Weight (only GRP boxes): I (protective earthing) 630 V AC (with mantle terminals block SL5, SL8 Ui = 400V AC) 16 A max. at T amb -20 C +40 C 10 A max. at T amb -20 C +50 C max. 2x4 mm2+2x2,5 mm2, 3x4 mm2, 2x6 mm2 SKX kg SKX ,7 kg SKX kg SKX kg MOUNTING With screw kit through the housing holes 6 mm at the peaks the rectangle: SKX 12: 75 x 50 mm SKX 13: 75 x 100 mm SKX 14: 75 x 150 mm SKX 15/15H: 125 x 150 mm 80 make your work surroundings safer

81 Control units Possible combinations and layout of indicators and actuators components SKX 12 SKX 13 SKX 14 SKX 15 * mounting proposals and dimensions Switch actuator SMO 17/. Switch mounting Pushbutton actuator SPO 01/. Front element of signal lamp SPO 02/. Pushbutton, signal lamp and potentiometer mounting Front element of measuring instrument (AM, VM) SAM 72 Measuring instrument mounting AM, VM Enclosure type SKX Max. No. of cable glands side cable gland M16 M20 M25 A-C B-D All technical data is relevant at the time of print. 81

82 Zone Enclosure type SKX 13 SKX 12 SKX Control unit SKX 13/10 Switch SMS 03/1, switch actuator SMO 17/1, cable gland SPU Max. No. of cable glands 100 cable gland side M16 M20 M25 A-C B-D Enclosure type SKX EMERGENCY STOP 152 Control unit SKX 14/MSRU... 2x pushbutton PBT 01, pushbutton actuator SPO 01/1, mushroom-head pushbutton actuator, 1x signal lamp SLP 01, front element SPO 02/02 cable gland SPU 25 Max. No. of cable glands cable gland side M16 M20 M25 M32 A-C B-D make your work surroundings safer

83 Control units Enclosure type SKX Control unit SKX 15/ x pushbutton PBT 01, pushbutton actuator SPO 01/1, SPO 01/2, ammeter AM /1A, front element of measuring instruments SAM 72, 2x cable gland SPU Max. No. of cable glands cable gland side M16 M20 M25 M32 M40 A-C B-D * with built-in N/PE busbar side cable gland M16 M20 M25 M32 M40 A-C B-D Various combinations of merged set (combination) of SKX enclosures 83

84 Zone SKX 12 SKX 15 MODEL CODE The program consists of serial control units and control units according to customer's request. SKX 12/.. Type Build-in components and actuator / indicator Overview SKX 12/1 Signal lamp SLP - red SPO 02/1 - cable gland SPU 25 SKX 12/2 Signal lamp SLP - green SPO 02/2 - cable gland SPU 25 SKX 12/3 Signal lamp SLP - white SPO 02/4 - cable gland SPU 25 - SKX 12/21 Control switch SMS 03/1 - switch actuator SMO 17/1 - cable gland SPU 25 SKX 12/22 Serial switch SMS 03/8 - switch actuator SMO 17/5 - cable gland SPU I - II - III SKX 12/23 Control switch SMS 03/6 - switch actuator SMO 17/2 - cable gland SPU 25 0 SKX 12/31 Pushbutton PBT 01 - Key-operated mushroom-head pushbutton actuator GHG R cable gland SPU 25 - SKX 12/32 Pushbutton PBT 01 - pushbutton actuator SPO 01/1 - cable gland SPU 25 SKX 12/33 Pushbutton PBT 01 - pushbutton actuator SPO 01/2 - cable gland SPU 25 I SKX 12/34 Pushbutton PBT 01 - Mushroom-head pushbutton actuator GHG R cable gland SPU 25 - SKX 12/35 Pushbutton PBT 01 - Mushroom-head pushbutton actuator GHG R0005 with protector - 2x cable gland SPU 20 - SKX 12/36 Pushbutton PBT Key-operated pushbutton GHG R0005-2x cable gland SPU 20 - SKX 12/37 Potentiometer GHG R GHG R cable gland SPU 25 - SKX 12/62 5x4 mm2 EURO 4/35 grey on rail TH 35-7,5-2x SPU 25 - SKX 12/63 5x4 mm2 EURO 4/35 blue on rail TH 35-7,5-2x SPU 25 blue - 84 make your work surroundings safer

85 Control units SKX 13/.. Type Build-in components and actuator / indicator Overview SKX 13/1 2x pushbutton PBT 01 - SPO 01/1 - SPO 01/2 - cable gland SPU 25 SKX 13/11 Pushbutton PBT 01 - SPO 01/1 - Signal lamp SLP - Front element of signal lamp SPO 02/2 - cable gland SPU 25 SKX 13/21 Mantle terminals SL8-6x cable gland SPU 25 - SKX 13/71 SKX 13/72 SKX 13/10 Switch GHG R... (Ex ) - switch actuator SMO 17/2 - cable gland SPU 25 Switch GHG R... (Ex ) - switch actuator SMO 17/1 - cable gland SPU 25 Switch SMS 03/1 - switch actuator SMO 17/1 - cable gland SPU 25 SKX 13/20 SMS 03/4 - SMO 17/2 - SPU 25 SKX 13/30 SMS 03/5 - SMO 17/2 - SPU 25 SKX 13/40 SMS 03/6 - SMO 17/2 - SPU 25 SKX 13/60 SMS 03/3 - SMO 17/3 - SPU 25 SKX 13/70 SMS 03/2 - SMO 17/1 - SPU 25 SKX 13/80 SMS 03/7 - SMO 17/1 - SPU 25 SKX 13/100 SMS 03/8 - SMO 17/5 - SPU 25 SKX 13/110 SMS 03/9 - SMO 17/1 - SPU 25 SKX 13/120 SMS 03/11 - SMO 17/2 - SPU SKX 14/.. Type Build-in components and actuator / indicator Overview SKX 14/1 2x pushbutton PBT 01 - SPO 01/1 - SPO 01/2 - Signal lamp SLP - SPO 02/2 - cable gland SPU 25 SKX 14/11 3x pushbutton PBT 01 - pushbutton actuator SPO 01/1 - SPO 01/2 - SPO 01/3 - cable gland SPU 25 SKX 14/21 Mantle terminals SL 8-8x cable gland SPU 25 - SKX 14/22 SKX 14/31 3x signal lamp SLP front element of signal lamp SPO 02/1 - SPO 02/2 - SPO 02/3 - cable gland SPU 25 3x pushbutton PBT 01 - pushbutton actuator SPO 01/1 - SPO 01/2 Mushroom-head pushbutton actuator GHG R cable gland SPU

86 Zone SKX 12 SKX 15 SKX 15/.. Type Build-in components and actuator / indicator Overview SKX 15/1 2x pushbutton PBT 01 - SPO 01/1 - SPO 01/2-2x signal lamp SLP - 02/1 - SPO 02/2-2x cable gland SPU 25 SKX 15/ x pushbutton PBT 01 - pushbutton actuator SPO 01/1 - SPO 01/2 - ammeter AM /1A - 2x cable gland SPU 25 SKX 15/ xPBT 01 - SPO 01/1 - SPO 01/2 - AM 72 50/1 A - 2xSPU 25 SKX 15/ xPBT 01 - SPO 01/1 - SPO 01/2 - AM /5 A - 2xSPU SKX 15/ xPBT 01 - SPO 01/1 - SPO 01/2 - AM 72 50/1 A - 2xSPU 25 SKX 15/21-11 SKX 15/21-12 SKX 15/21-21 SKX 15/21-22 SKX 15/34 SKX 15/41 SKX 15/50 SKX 15/90 SKX 15/51 SKX 15/61 SKX 15/62 SKX 15/65 Switch GHG 23..R.. - switch actuator SMO 17/1 - ammeter AM /1 A - 2x uvodnica SPU 25 Switch GHG R - switch actuator SMO 17/1 - ammeter AM /1 A - 2x uvodnicaspu 25 Switch GHG R... - Switch actuator SMO 17/1 - ammeter AM /5 A - 2x uvodnica SPU 25 Switch GHG R... - switch actuator SMO 17/1 - ammeter AM 72 50/5 A - 2x cable gland SPU 25 4x pushbutton PBT/1-2xSPO 01/1-2xSPO 01/2-2x cable gland SPU 25 Switch SMS 03/1-2x terminal EURO E x cable gland SPU 25 Switch SMS 03/12 - SMO 17/2 - cable gland SPU 25 Switch SMS 03/10 - SMO 17/3 - cable gland SPU 25 Switch SMS 03/9 - SMO 17/1-2x pushbutton PBT/1 - SPO 01/1 - SPO01/2-2x cable gland SPU 25 Switch GHG R... (Ex ) - SMO 17/2-5x terminal EURO E4 - cable gland SPU 25 Switch GHG R... (Ex ) - SMO 17/1-5x terminal EURO E4 - cable gland SPU 25 4x mantle terminals SL5-8x cable gland SPU make your work surroundings safer

87 Control units BUILD-IN COMPONENTS Description, type Schema / type Overview Control switch SMS 03/. II 2G I M2 Ex de I/IIC Gb Mb Rated voltage: 630 V AC Rated current: 16 A Terminals: 2,5 mm

88 Zone SKX 12 SKX 15 BUILD-IN COMPONENTS Description, type Schema Overview Control switch GHG 23. II 2GD Ex de IIC Rated voltage: 690 V AC Rated current : 10 A Terminals: 2,5 mm 2 88 make your work surroundings safer

89 Control units BUILD-IN COMPONENTS Description, type Schema Overview Pushbutton PBT/. Rated voltage: 630V AC Rated current: 16A Terminals: 2,5 mm 2 Signal lamp SLP Rated voltage: V AC/DC Max. current: 20-8 ma Terminals: 2,5 mm 2 Potentionmeter PBT/POT Rated voltage: 315 V AC/DC Rated power: 1W Scale: 0-100% / 270 Tolerance: ±20% Characteristic: linear Terminals: 2,5 mm 2 Resistance R: 1,0 k 2,2 k 4,7 k 10 k 470 k Measuring instruments AM 72, VM 72 Measuring range: AM: n/1 A, 0-20 ma, 0-25 A direct 4-20 ma VM: n/1a, 6-415V, V Scale: according to customer demand Terminals: 1,5-4 mm 2 - Mantle terminals SL5, SL8 Rated voltage: 400 V Rated current: 16 A AC Terminals: 4 mm 2 Max. No. of wire under one clamp: 2x4mm 2 + 2x2,5mm 2, 3x4mm2 - Terminals TH terminals 4mm 2 2 terminals 16mm 2 Rated voltage: 690 V AC Rated current: 16 A - N/PE busbar (only for SKX 15) 11x max. 2x4mm

90 Zone SKX 12 SKX 15 ACTUATORS AND INDICATORS Description, type Mounting Overview Switch actuator SMO 17/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db 0 I I II I 0 II I II III 0 SMO 17/1 SMO 17/2 SMO 17/3 SMO 17/ III I II SMO 17/5 SMO 17/6 SMO 17/7 SMO 17/8 SMO 17/9 3 4 Front element of measuring instruments SAM 72 II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db Type SPO 01/. SPO 01/01 0 Puschbitton actuator SPO 01/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db SPO 01/02 SPO 01/03 SPO 01/04 SPO 01/05 SPO 01/06 SPO 01/07 SPO 01/08 SPO 01/09 SPO 01/10 I II RED GREEN WHITE START STOP ON OFF Front element of signal lamp SPO 02/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db Type SPO 02/. SPO 02/01 RED SPO 02/02 GREEN SPO 02/03 YELLOW SPO 02/04 TRANSPARENT Key-operated pushbutton actuator GHG R0012 II 2GD Ex e II IP66 90 make your work surroundings safer

91 Control units BUILD-IN COMPONENTS Description, type Mounting Overview Mushroom-head pushbutton actuator GHG R.. (EMERGENCY-STOP) II 2GD Ex e II IP66 Key-operated mushroom-head pushbutton actuator GHG R.. (EMERGENCY-STOP) II 2GD Ex e II IP66 Potentiometer acuator GHG R0010 II 2GD Ex e II IP66 Cable gland SPU ISO 16 - ISO 40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Cable gland for armourd cable SPU A ISO 16 - ISO 40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Plug SPC.. ISO 16 - ISO M40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Connection part SKX 91

92 Zone SKX 16, 18, 20 IP C -20 Enclosures made of glass-fibre reinforced polyester resin or stainless steel AISI 316L 3 basic enclosure sizes in GRP 3 basic enclosure sizes in stainless steel CONSTRUCTION Enclosure: polyester plastic reinforced with glass fiber, color - black Stainless steel AISI 316L, brush finished, thickness 1.5mm Cover: with integrated thermoplastic elastomer gasket, closes with four/six M5/M6 stainless steel screws. TECHNICAL DATA Certificate: EXA 13 ATEX 0029, EXA 15 ATEX 0036 RU C-HR.AB24.B.03291, RU C-HR.AB24.B Alone or in various combinations of merged set Marking: 0722 Equipped with built -in components Ambient temperature ATEX: EAC: Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: I (protective earthing) 690 V AC (with mantle terminals block SL5, SL8 Ui = 400V AC) Up to 80 A Control devices Apparatus category: Marking of explosion protection: Indicating lamps Pushbuttons Switches Nominal current: PE terminals (inside of the enclosure): Ammeters Connection: Version with hinged doors II 2GD max. 2x4 mm2+2x2,5 mm2, 3x4 mm2, 2x6 mm2 Depending on order requirements at the built-in components or at the terminal blocks. The rated operational voltage, the rated operational current and the rated cross-section depend on the terminal type used and the explosion protected components. Control units SKX 16, SKX 18, SKX 20 are Ex combinations configured according to customer demand. Type designation consists of a basic type designation - SKX 16, SKX 18, SKX 20, I for enclosure made of SS AISI 316L and SRU number that represents the number of production and assigns to the increment. Example: SKX 18 I / SRU managing the combination of the housing MMK I - stainless steel enclosure AISI 316L performed by production number make your work surroundings safer

93 Control units GRP enclosure SKX 16 Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C GRP enclosure SKX 18 Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C All technical data is relevant at the time of print. 93

94 Zone SKX 16, 18, 20 GRP enclosure SKX 20 Side Cable gland M20 M25 M32 M40 M50 M63 B-D A-C Example: Ex control units with GRP enclosures 94 make your work surroundings safer

95 Control units Stainless steel AISI 316L enclosure SKX 16 I, SKX 18 I, SKX 20 I A[mm] B[mm] C[mm] SKX 16 I SKX 18 I SKX 20 I MOUNTING D[mm] E[mm] F[mm] G[mm] SKX 16 I SKX 18 I SKX 20 I Example: Ex control units with stainless steel AISI 316L enclosures 95

96 Zone SKX 16, 18, 20 BUILD-IN COMPONENTS Description, type Schema Overview Control switch SMS 03/. II 2G I M2 Ex de I/IIC Gb Mb Rated voltage: 630 V AC Rated current: 16 A Terminals: 2,5 mm 2 Main curent switch GHG 260 Rated voltage: 690 V AC Rated current : A Terminals: mm 2 96 make your work surroundings safer

97 Control units BUILD-IN COMPONENTS Description, type Schema Overview Control switch GHG 23. II 2GD Ex de IIC Rated voltage: 690 V AC Rated current : 10 A Terminals: 2,5 mm

98 Zone SKX 16, 18, 20 BUILD-IN COMPONENTS Description, type Schema Overview Pushbutton PBT/. Rated voltage: 630V AC Rated current: 16A Terminals: 2,5 mm 2 Signal lamp SLP Rated voltage: V AC/DC Max. current: 20-8 ma Terminals: 2,5 mm 2 Potentionmeter PBT/POT Rated voltage: 315 V AC/DC Rated power: 1W Scale: 0-100% / 270 Tolerance: ±20% Characteristic: linear Terminals: 2,5 mm 2 Resistance R: 1,0 k 2,2 k 4,7 k 10 k 470 k Measuring instruments AM 72, VM 72 Measuring range: AM: n/1 A, 0-20 ma, 0-25 A direct 4-20 ma VM: n/1a, 6-415V, V Scale: according to customer demand Terminals: 1,5-4 mm 2 - Mantle terminals SL5, SL8 Rated voltage: 400 V Rated current: 16 A AC Terminals: 4 mm 2 Max. No. of wire under one clamp: 2x4mm 2 + 2x2,5mm 2, 3x4mm2 - Terminals TH terminals 4mm 2 2 terminals 16mm 2 Rated voltage: 690 V AC Rated current: 16 A - N/PE busbar (only for SKX 15) 11x max. 2x4mm 2-98 make your work surroundings safer

99 Control units ACTUATORS AND INDICATORS Description, type Mounting Overview Switch actuator SMO 17/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db 0 I I II I 0 II I II III 0 SMO 17/1 SMO 17/2 SMO 17/3 SMO 17/ III I II SMO 17/5 SMO 17/6 SMO 17/7 SMO 17/8 SMO 17/9 3 4 Ø87,5 60 Ø5x6 Switch actuator GHG Ø13 Front element of measuring instruments SAM 72 II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db Type SPO 01/. SPO 01/01 0 Puschbitton actuator SPO 01/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db SPO 01/02 SPO 01/03 SPO 01/04 SPO 01/05 SPO 01/06 SPO 01/07 SPO 01/08 SPO 01/09 SPO 01/10 I II RED GREEN WHITE START STOP ON OFF Front element of signal lamp SPO 02/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Ex t IIIC Db Type SPO 02/. SPO 02/01 RED SPO 02/02 GREEN SPO 02/03 YELLOW SPO 02/04 TRANSPARENT Key-operated pushbutton actuator GHG R0012 II 2GD Ex e II IP

100 Zone ACTUATORS AND INDICATORS Description, type Mounting Overview Mushroom-head pushbutton actuator GHG R.. (EMERGENCY-STOP) II 2GD Ex e II IP66 SKX 16, 18, 20 Key-operated mushroom-head pushbutton actuator GHG R.. (EMERGENCY-STOP) II 2GD Ex e II IP66 Potentiometer acuator GHG R0010 II 2GD Ex e II IP66 Cable gland SPU ISO 16 - ISO 40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Cable gland for armourd cable SPU A ISO 16 - ISO 40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Plug SPC.. ISO 16 - ISO M40 II 2G II 2D Ex e I/IIC Gb Ex t IIIC Db Connection part SKX 100 make your work surroundings safer

101 Control units BUILD-IN COMPONENTS Description, type Schema Overview Main fuse NH0 300XX, NH0, 301XX - BUILD IN SOCKET 16 A (3p/5p), 32A (4p) II 2G Ex de IIC II 2D Ex td A21 IP66 T80 C - RESIDUAL CURRENT CIRCUIT BREAKERS 2p/4p 25/40/63 A, 30 ma, 10 ka with or without auxiliary contact - II 2G Ex d e IIC Gb DIGITAL INDIKATOR VEGADIS 175 Ex II 1G EEx ia IIC T6 - HRC FUSE, Ex d HOUSING 3p NH00C the base and fuse II 2G Ex de IIC I M2 Ex de I

102 Zone 1 2 GGCD IP 66 C Active grounding system for static grounding and permanent monitoring Permanent removal of electrostatic charge during filling or emptying tanks (road tracks, railcar tanks, barrels) Two output contacts TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature ATEX: EAC: II 2G CESI 11 ATEX 041, EAC RU C-HR.AB24.B Ex d e [ib] mb IIC T5 Gb -20ºC T a +50ºC -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : I (protective earthing) Rated voltage: 230 V± 10% Rated current: Frequency: Output circuit: Cable entry: Weight: Packing: MOUNTING 50 ma 50Hz CONSTRUCTION Enclosure: polyester plastic reinforced with glass fiber, color - black Cover: with integrated Thermoplastic elastomer gasket, closes with four M6 stainless steel screws. 2 NO/NC Un=250VAC, In=8A / 230V, 4A at cos =0.4 3 x M25 - power supply, two output circuit 4 x M25-2x connection clamp, 2x wire to equipotential busbar or grounding 6 kg (without clamp and cable) weight of clamps with 10 m cable ca. 2,5 kg The packing contains: 1 pcs 430x350x230 mm Wall bracket with four screws O make your work surroundings safer

103 Grounding and grounding control device DIMENSION DRAWING (all dimensions in mm) MODEL CODE DESCRIPTION GGCD-01/K1 Type with one a clamp K1 with 10m spiral cable GGCD-01/K2 Type with two clamps K1 with 2x10m spiral cable MODEL CODE Principle of work for GGCD-01/.. All technical data is relevant at the time of print

104 NOTES

105 Distribution cabinets Busbar enclosures

106 Zone R R3006 IP 66 IK 08 C IM2 Enclosure in sheet steel 5 basic enclosure sizes Enclosures can be combined (modular system) Available as empty enclosures or as completely fitted and wired control and distribution units For use in underground mines Cable entries available: Direct : cable glands, Indirect : via Ex e enclosure multiwire bushing, conductor insulator CONSTRUCTION Enclosure: sheet steel (Exd enclosure 12mm thickness, Exe enclosure 3mm thickness Gasket: EPDM formed gasket TECHNICAL DATA Certificate: Marking: 0722 II 2G Apparatus category: II 2D I M2 Ex de I/IIC T6 Gb Mb Marking of explosion protection: Ex tb IIIC Db Ambient temperature ATEX: -20ºC T a +50ºC EAC: -50ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 09 Protection class : Rated voltage: Rated current: EXA 14 ATEX 0050X, RU C-HR.AB24.B I (protective earthing) Up to 690 V AC Terminal cross-section: 240 mm 2 Weight: - Enclosure R Enclosure R Enclosure R Enclosure R Enclosure R3006 Color: Up to 500 A (depends upon built-in device) 70 kg 18 kg 47 kg 15 kg 9 kg Yellow, RAL1016 (other color on request) 106 make your work surroundings safer

107 Distribution cabinets DIMENSION DRAWING (all dimensions in mm) R3003 R3003 R R3005 R3005 R3006 R3002 R R3004 R3004 R R Free-standing modular system with protection canopy All technical data is relevant at the time of print. 107

108 Zone R R3006 A distribution cabinets type R3002 and R3004 is made of steel with Ex d flameproof protection type. Closing of the cabinet is of threaded type and is protected against opening by lock switch, so that it can be opened only when it is not under voltage. The units is protected against corrosion by its painting inside and outside. Ex d steel enclosures (type R3002 and R3004) and Ex e sheet steel enclosures (type R3003, R3005, R3006) can be used as single enclosures and combinations. The dimensions of the enclosures are so designed that they can be combined into a large modular unit. A large number of components, such as contactors, switches, instruments and PLCs can be built into these enclosures. Naturally, customer-supplied equipment can also be incorporated into the layout. The equipment layout is designed by us to customer's requirements. Cable entry is either direct (cable glands or conduit entries) or indirect via an Ex e enclosures type R3003, R3005, R3006. The "flameproof" type protection 'Ex d' is based on the principle that electrical components which may cause sparks or arcing in normal operation (switches, contactors etc.) are in an enclosure constructed so that it will contain an explosion of flammable gas or vapor and will not permit ignition of a surrounding explosive atmosphere. Further, the temperature of the outside surface of the enclosures must not exceed the prescribed temperature limit for the appropriate temperature class. That means, the heat loss from the components fitted must not exceed a specified value. Data required for the layout of control and distribution boards We produce distribution cabinets accordint to customer requirements and basis to the project data: the required minimum type of protection as appropriate, details of the hazardous atmosphere for which the equipment must be suitable single line or wiring diagram schematic for control systems operating, auxiliary and control voltages frequency power and current ratings of connected loads quantities and types of components required, e.g. contactors, switches, circuit-breakers, fuses, thermal relays, instruments, terminals etc quantity and types of cables number and size of conductors quantity and location of entries (from top, bottom, side, centre) environmental conditions method of installation TYPE OF INSTALLATION A) temporary B) wall-mounted C) free-standing With or without protection canopy 108 make your work surroundings safer

109 SPOJ ZA DIRKTNO POKRETANJE TROFAZNOG MOTORA I DVA SMJERA VRTNJE SPOJ ZA POKRETANJE TROFAZNOG MOTORA U SPOJU ZVIJEZDA - TROKUT Distribution cabinets Examples of wiring diagram for distribution cabinets -F1 L1 L2 L3 -F1 L1 L2 L3 -Q1 I I I Q Q Q Q Q F Pe F Pe U V W M SPOJ ZA DIRKTNO POKRETANJE 3 TROFAZNOG MOTORA U1 V1 W1 3 M V2 W2 U2 A) Direct on line start of tree phase motor; B) STAR-DELTA switching of three phase motor two directions of rotation L1 L2 L3 -F1 -Q F Pe EXIT U V W 3 M C) Direct on line start of tree phase motor D) Light fittings control panel 109

110 Zone SKX busbar IP 66 IK 09 C For terminals from mm 2 Rated operational current up to max. 450 A depending on enclosure version and size CONSTRUCTION Enclosure: Stainless steel AISI 316L, 1.5mm Gasket: EPDM formed gasket TECHNICAL DATA Certificate: EXA 14 ATEX 0002 Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature ATEX: II 2G II 2D Ex e IIC T6 Gb Ex tb IIIC T80 C Db -20ºC T a +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 09 Protection class : I (protective earthing) Nominal voltage U n : 690 V ±10% Table of maximum currents: Terminal Cross section t amb 40 C do +40 C t amb 40 C do +50 C 240 mm A 425 A 300mm mm A 390 A 150 mm A 350 A 120 mm A 300 A 95 mm A 250 A 120 mm 2 70 mm A 185 A 50 mm A 130 A 35 mm A 80 A 110 make your work surroundings safer

111 Busbar enclosure MODEL CODE SKX xxxxxxxx-. /... number of cable entries number and size of terminals type and design of enclosure SKX (600x400x160 mm) SKX (1000x800x160 mm) DIMENSION DRAWING (all dimensions in mm) A C D F B E Type A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] SKX SKX SPARE PARTS AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Cover Gasket SKX / SKX / Terminal 35 mm 2 SKX / Terminal 120 mm 2 SKX / Cover screw M5x25 SKX / Terminal 300 mm 2 SKX / Mounting set SKX / Strain relief set 3/4" SKX / Busbar holder PE SKX / Strain relief set 1" SKX / Busbar holder SKX / Strain relief set 5/4" SKX / Busbar Cu 30x10 SKX / Strain relief set 6/4" SKX / All technical data is relevant at the time of print. 111

112 NOTES

113 Signalling devices Plugs and sockets Accessories

114 Zone dhh, mhpt C IP 66 Loud signal horn with typical horn tone Lower weight, robust and corrosion proof design Insulation class II, no equipotential bonding required CONSTRUCTION Glassfibre reinforced polyester TECHNICAL DATA type dhh Certificate: PBT 01 ATEX 1133 Marking: 0102 Apparatus category: II 2G II 2D Marking of explosion protection: Ex de IIC T5, T6 Gb Ex tb IIIC T95 C, T80 C Db Ambient temperature: -25 C T a +75 C Degree of protection: IP 66 Rated voltage: Terminals: 2,5mm 2 6V AC/DC 220V AC/DC Cable entries: 1 x cable gland M20x1,5, 1 x plug M20 x1,5 Weight: 5,5 kg DIMENSION 114 make your work surroundings safer

115 Signal devices TECHNICAL DATA type mhpt Certificate: PBT 01 ATEX 1133 Marking: 0102 Apparatus category: II 2G Marking of explosion protection: Ex e mb IIC T5 Ambient temperature: -20 C T a +70 C Degree of protection: IP 54 Rated voltage: 24V DC, 115 V AC, 230 V AC Terminals: 2,5mm 2 Cable entries: 1 x cable gland M20x1,5 Weight: 1,5 kg DIMENSION All technical data is relevant at the time of print. 115

116 Zone dhw C IP 66 Loud signal bell with typical bell tone Insulation class II, no equipotential bonding required CONSTRUCTION Glassfibre reinforced polyester TECHNICAL DATA type dhw Certificate: PBT 01 ATEX 1134 Marking: 0102 Apparatus category: II 2G II 2D Marking of explosion protection: Ex de IIC T6 Ex td A21 IP66 T80 C Ambient temperature: -20 C T a +40 C Degree of protection: IP 66 Rated voltage: Terminals: 2,5mm 2 6V AC/DC 220V AC/DC Cable entries: 1 x cable gland M20x1,5, 1 x plug M20 x1,5 Weight: DIMENSION 6 kg 116 make your work surroundings safer

117 Signal devices All technical data is relevant at the time of print

118 Zone dst1 IP 66 IK 09 C Explosion-proof telephone for universal applications in the industry (onshore and offshore) Resistant against high temperature differences, humidity,seawater, acids, alkalis etc. 10 ringing tone melodies selectable CONSTRUCTION Glassfibre reinforced polyester TECHNICAL DATA type dst1 Certificate: DMT 03 ATEX E 034 Marking: 0158 Apparatus category: II 2G II 2D Marking of explosion protection: Ex e mb [ib] IIC T5 Gb Ex tb [ib] IIIC T100 C Db Ambient temperature: -25 C T a +60 C Degree of protection: IP 66 Rated voltage: Terminals: 4 mm 2 Cable entries: Weight: 24 V DC-66 V DC 1 x M20x1,5 2 x blind plug M20x1,5 5,5 kg DIMENSION 118 make your work surroundings safer

119 Telephone All technical data is relevant at the time of print

120 Zone DF1013 / DF104 / DS-14 IP 68 C For inspection and maintenance work TECHNICAL DATA type DF1013 Apparatus category: II 1G Marking of explosion protection: Ex ia IIC T4 Ga Ambient temperature: -20 ºC T amb +40ºC Degree of protection: IP 68 Luminous flux: 60 lm Lenght of light beam: 130 m Batterry: 4x AA type Autonomy: app. 14 hours Weight: 100 g (without batterry) Dimension: 175x45x45 mm Push Button LED 120 make your work surroundings safer

121 Torchlights / headlamp TECHNICAL DATA type DF104 Apparatus category: II 1G Marking of explosion protection: Ex ia IIC T4 Ga Ambient temperature: -20 ºC T amb +40ºC Degree of protection: IP 68 Luminous flux: 43 lm Lenght of light beam: 32 m Batterry: 3x C type Autonomy: app. 70 hours Weight: 190 g (without batterry) Dimension: 220x60x85 mm 12 Ø5 LEDs Push Button TECHNICAL DATA type DS-14 (headlamp) Apparatus category: II 1G Marking of explosion protection: Ex ia IIC T4 Ga Ambient temperature: -20 ºC T amb +40ºC Degree of protection: IP 67 Luminous flux: 75lm / low mode, 150lm / High mode Lenght of light beam: 75m / 100m Batterry: 3x AAA type Autonomy: app. 4 hours Weight: 145 g (without batterry) Dimension: 80x50x45 mm HELMET MOUNTABLE RUBBERISED BUTTON SMOOTH REFLECTION LOCKING BATTERY COMPARTMENT All technical data is relevant at the time of print. 121

122 Zone PRE IP 66 IK 09 C Plugs and sockets receptacles 16A to 63A, 12V to 690V All sockets incorporate switching technology that prevents removal of the plug under electrical load and does not disturb the potentially explosive atmospheres CONSTRUCTION Socket/ 2P - 2P+E - 3P: polycarbonate Socket / 3P+E - 3P+N+E: SMC Plug, mobile socket, flush socket: polyamide TECHNICAL DATA Certificate: LCIE 02 ATEX 6068, LCIE 02 ATEX 0001U Marking: Apparatus category: II 2G II 2D Marking of explosion protection: Ex de IIC T6 Ex td A21 T68ºC Ambient temperature: -40 ºC T amb +55ºC Degree of protection: IP 66 Impact resistance: IK09 Plug Wall socket Mobile socket Flush socket 122 make your work surroundings safer

123 Plugs and sockets MODEL CODE / 16A All technical data is relevant at the time of print

124 Zone MODEL CODE / 32A PRE 124 make your work surroundings safer

125 Plugs and sockets MODEL CODE / 63A 125

126 Zone DIMENSION / 16A PRE 125 make your work surroundings safer

127 Plugs and sockets DIMENSION / 32A DIMENSION / 63A 126

128 Zone ADP IP 66 IK 08 Ex e side Ex d side For electrical connection between Exd and Exe enclosure without usage of the special Ex d cable glands Multi-core bushing with external thread M 20 or ½ " NPT and mounted connection terminals designed in type of protection increased safety "e". CONSTRUCTION Enclosure: PA cover Multi-core bushing: brass nickel plated (SS AISI 316 on special request) TECHNICAL DATA Certificate: EXA 14 ATEX 0043U Marking: 0722 Apparatus category: II 2G II 2D Marking of explosion protection: Ex d e IIC Gb Ex tb IIIC Db Service temperature: -20 ºC T service +60 ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: Rated current: I (protective earthing) 400V 16 A Connection terminal : L1, L2, L3, N, PE, 2 x max.2,5 mm 2 Cable gland: For cable 6-15 mm 128 make your work surroundings safer

129 Adapter MODEL CODE TYPE WIRING ADP 22 2x1.5mm 2 ;black, black ADP 23 3x1.5mm 2 ; brown, blue, yellow-green ADP 24 4x1.5mm 2 ; black, brown, blue, yellow-green Other configurations available on request DIMENSION DRAWING (all dimensions in mm) WIRE LENGHT (Ex d side) 200 mm OVERVIEW OF APPLICATIONS M20 Ø52 All technical data is relevant at the time of print. 129

130 Zone 1 2 RSM IK 08 C CONSTRUCTION For electrical connection between flameproof enclosures or between flameproof enclosure and enclosure with another type of protection Brass body (SS AISI 316 on special request) TECHNICAL DATA Certificate: EXA 16 ATEX 0002U, IECEx EXA U Marking: 0722 Apparatus category: Marking of explosion protection: Service temperature: Rated voltage U o / U: : Rated current I e : Wire: II 2G I M2 Ex db IIC Gb Ex db I Mb -50ºC T service +120ºC 400/1000 V AC Determined by technical data of device - rated cross-section 1,5-50 mm 2 - type RADOX 155 or BETAtherm 155 IEC class 5 MODEL CODE TYPE NUMBER AND CROSS-SECTION OF WIRES SIZE OF THREAD/ THREAD LENGTH (mm) KEY SIZE AF/ BUSHING LENGTH (mm) WIRE LENGTH (THREAD SIDE) (mm) TOTAL WIRE LENGTH (mm) RSM 21 4 x 1,5mm 2 RSM 23 6 x 1,5mm 2 M25x1,5-6g/18 OK 30 / RSM 25 8 x 1,5mm RSM x 1,5mm 2 RSM x 1,5mm RSM 33 6 x 2,5 mm 2 M33x1,5-6g/18 OK 36 / 30 RSM 35 6 x 4 mm 2 RSM 37 6 x 6 mm x x310 RSM 41 6 x 10 mm 2 M36x1,5-6g/18 OK 41 / 30 RSM 51 6 x 16mm 2 RSM 53 3 x 25mm 2 M42x1,5-6g/18 OK 46 / 30 RSM 55 3 x 35mm 2 RSM 61 6 x 25mm RSM 63 6 x 35mm 2 M50x1,5-6g/18 OK 55 / 30 RSM 65 3 x 50mm 2 RSM x 1,5mm 2 2 x M32x1,5-6g/18 OK 41 / Other configurations available on request 130 make your work surroundings safer

131 Multicore bushing All technical data is relevant at the time of print

132 Zone 1 2 SMP IP 20 C CONSTRUCTION Ex electronica ballast for T8 fluorescent tube 18, 36 and 58 W 18W and 36W in parallel configuration With overcurrent, overvoltage and over temperature protection SMP enclosure: plastic PA6 TECHNICAL DATA Certificate: Marking: 0722 Apparatus category: Marking of explosion protection: Ambient temperature: Degree of protection: IP 20 Frequency: Protection class : Lamps type: EXA 13 ATEX 0016U II 2G Ex db IIC Gb Ex db I Mb -25 ºC T amb +70ºC Hz I (protective earthing) Fluo lamps T8 1-2 x 18/36/58 W Power factor: ~0.95 BLF - Ballast lumen factor: ~ 97 % Estimated service life: Connection terminal: hours at T amb =65 C hours at T amb =70 C 1,0-2.5mm 2, PE terminal 132 make your work surroundings safer

133 Electronic ballast MODEL CODE TYPE LAMP TYPE SMP 07/11 1 x 18/36W T8 Parallel configuration SMP 07/12 2 x 18/36W T8 / double channel SMP 08 2 x 58W T8 Single channel DIMENSION DRAWING (all dimensions in mm) SMP PE N L Medarska 69, Zagreb, Croatia Made in Croatia 0722 SMP V 50Hz 500mA 2 x 58 W T8 II 2G Ex eb mb IIC Gb -20 C<T service <+80 C MA -... EXA 16 ATEX.... U DAT -... L2 LL L PE N L Medarska 69, Zagreb, Cro Made in Croatia SMP V 2 x 58 W T8 II 2G Ex eb -20 C<T service <+ EXA 16 ATEX WIRING DIAGRAM All technical data is relevant at the time of print. 133

134 Zone SPU/SPC IP 68 C PLASTIC CABLE GLANDS Exe Polyamide body / neoprene gasket Ex e plastic cable glands Ex d metal cable glands for armored cable TECHNICAL DATA Apparatus category: II 2GD Marking of explosion protection: Ex e Ambient temperature: -35 ºC T amb +95ºC Degree of protection: IP 68 MODEL CODE THREADS CLAMPING RANGE H (mm) E (mm) L (mm) RAL 5012 RAL 9005 M12 4,0-6, F E F E M16 6,0-10, F E F E M20 7,0-12, F E F E M25 10,0-18, F E F E M25 6,00-15, SPU 25 B SPU 25 M32 17,0-24, F E F E M40 17,0-31, F E F E M50 24,5-37, F E F E M63 34,0-47, F E F E ISO E H L 134 make your work surroundings safer

135 Cable glands, plugs, adapters, reducers, locknuts METAL Ex d/e CABLE GLANDS (double sealing, for armoured cable) type 4F Brass nickel plated (AISI 316 on special request) TECHNICAL DATA Apparatus category: Marking of explosion protection: II 2GD Ex d/e Ambient temperature: -40 ºC T amb +95ºC Degree of protection: IP 68 MODEL CODE THREADS CLAMPING RANGE H (mm) E (mm) CODE M16 7,0-12, M20 9,0-16, M20 13,0-21, M25 13,0-21, M25 17,0-27, M32 22,0-34, M40 28,0-41, M50 34,0-48, M63 39,0-54, M63 48,0-65, M75 55,0-74, E OTHER ACCESSORIES Other accessories (Exd metal plugs, Exe plastic plugs, adapters, reducers, locknuts, earth tags) are available according to customer request. All technical data is relevant at the time of print. 135

136 NOTES

137 Availability, design and specifi cations are subject to change without notice. All rights reserved. Printed in the Republic of Croatia, april 2017, TEPEx d.o.o.

138 Prilaz dr.f.tuđmana 6, ZABOK, CROATIA Tel: , Fax: Web:

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ d.o.o. tel. 049 222 900 fax. 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/ No: TEPEx.RS.028 Rev : 1 Date: 09.2014. SADRŽAJ 1. Manufacturer 1 2. General

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

EWE. Ex de. Cooling fins

EWE. Ex de. Cooling fins EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08 Zone 1 21 22 2 SKX 16, 18, 20 IP 66 +50 C 20 Enclosures made of glassfibre reinforced polyester resin or stainless steel AISI 316L 3 basic enclosure sizes in GRP 3 basic enclosure sizes in stainless steel

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

EWE. Cooling fins. Ex de

EWE. Cooling fins. Ex de EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

FHL. Ex d. Body in aluminium

FHL. Ex d. Body in aluminium Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W /27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3

More information

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS 4 5 6 8 EX-CEILING LIGHT FITTINGS EX-PENDANT LIGHT FITTINGS 4.4 4.0 EX-FLOODLIGHTS EX-VESSEL LIGHT FITTING 4.8 4.46 0 ZONE / EX-PENDANT LIGHT FITTINGS

More information

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 SLEE - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22 S u p p or t i n g br a c ket Hin ge for op en in g

More information

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood

More information

Easy and safe installation

Easy and safe installation ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Sheet-Steel Light Fittings Series 6014 / 6414

Sheet-Steel Light Fittings Series 6014 / 6414 > As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive

More information

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22 Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb

More information

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408 > As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 1 EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS 2 ouse se-hin inds 20 08 - all righ ghts re serv rved C ou Co oper Cr 3 4 5 6 7 EX-CEILING LIGHT FITTINGS 5.41 8 EX-PENDANT LIGHT FITTINGS EX-FLOODLIGHTS

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVDL LED fitting - zones 21, & 22 ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article

More information

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114 > As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

Industrial luminaires

Industrial luminaires Industrial luminaires Acciaio 112 Leader BS 101 114 Leader BS 103 3G 115 Leader BS 111 116 Leader BS 113 117 Leader 21-01, 21-04 118 BS100, BS110 119 Tores 23-01 120 Castor 25-05 121 Lumino 26-91 122 Leo

More information

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22 LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray

More information

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Intrinsically Safe Explained Ha ardous Area Classification Zone 0, Zone, Zone This diagram shows

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

PROTECTA III. Construction Tough glass reinforced polyester body

PROTECTA III. Construction Tough glass reinforced polyester body PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure

More information

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens Part #: EPL-HB-25LED-RT Page: 1 The Larson Electronics EPL-HB-25LED-RT Explosion Proof High Bay light

More information

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , 1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection

More information

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 > For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety : : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety : : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2 Features Wide or narrow beam Ex e integral junction box Flat or pole mounting Supplied with lamp installed Including accessories (cable gland & plug) Supplied with offshore grade paint Manufactured from

More information

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Industrial luminaires

Industrial luminaires Industrial luminaires acciaio When rapidity is money......you install 4 fittings in the time of 1 Industrial luminaires T5 and T8 Material: body: in zinc steel painted color: gray Degree of protection:

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings Fluorescent fitting EVN - Zones 2 & 22 Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion EX-PROTECTION ADVANTAGES Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all zones The

More information