PT Series. Tank Top Filters

Size: px
Start display at page:

Download "PT Series. Tank Top Filters"

Transcription

1 PT Series Tank Top Filters 9

2 PT Series Applications Together we can Preserve the environment. Minimize waste and promote energy effi ciency. Achieve worldwide fi ltration solutions. Build global confi dence. Redefi ne new limits. Forge ahead with advanced technology. Keep contamination under control. Reduce maintenance costs. Enhance total system reliability. Focus on customer satisfaction. Reach optimum potential. Drill to greater depths. engineer your success. The new PT series fi lter is available in two diameters and three lengths for fl ow ranges from 5-5 gpm. The PT2 and PT4 fi lter cartridges utilize Microglass media in 2, 5, 1 and 2 microns for the industry s best particle removal effi ciency and retention. This unique design simply threads into a ported weld ring or fl ange, which can be bolted to a metal reservoir. The disposable fi lter cartridge is a single-piece construction, which incorporates the nylon cover and integral 25 psi bypass valve. The fl ow path is inside-out and requires no special tools for service. This concept assures minimal installation costs with the least space requirements for return line applications. Typical Applications Turf Maintenance Material Handling Aerial Lifts Fan Drive The PT Series fi lter combines high effi ciency Microglass fi ltration with low cost installation featured in a new patented element design. 1

3 PT Series Features Easy element assembly removal 2 Unique high flow top end cap 4 3 Lightweight cast aluminum head 4 Patented filter element assembly 5 Bowl-less, inside-out flow Downstream element support with no aeration design Solid bottom endcap with integrated bypass valve Low profile tank top design

4 PT Series Patented Filter Element Premium original equipment performance every time Tank Top, Bowl-Less Design Reduces weight Significant cost savings over filters with bowls Bottom Endcap Integrated Bypass Valve New bypass valve with every element change Insures reliable performance Inside-Out Element Flow Path Contamination contained within the element No system contamination during element servicing No Aeration Design Oil cascades down the perforated outer support core No system aeration High Flow, Low Pressure Drop Top Endcap Design Long element life Lower maintenance costs Premium Microglass Media Superior dirt holding capacity and efficiency Less maintenance and downtime 12

5 PT Series PT2-1 Element Performance Beta Rating 1 Efficiency Efficiency % PSID 1 Capacity BAR Q 5Q 1Q 2Q s Q 5Q 1Q 2Q Micron Size (c) Capacity grams 1 Flow vs. Pressure Loss* LPM PSID BAR GPM Results typical from Multi-pass tests run per test standard ISO 1 gpm to 1 psid terminal - 1 mg/l BUGL. Refer to Appendix on pages for relationship to test standard ISO *Note: Pressure drop calculations are based on SAE-12 porting. 13

6 PT Series PT2-2 Element Performance PSID 1 Capacity BAR Q 5Q 1Q 2Q Capacity grams 1 Flow vs. Pressure Loss* LPM PSID BAR GPM Results typical from Multi-pass tests run per test standard ISO 15 gpm to 1 psid terminal - 1 mg/l BUGL. Refer to Appendix on pages for relationship to test standard ISO *Note: Pressure drop calculations are based on SAE-12 porting. 14

7 PT Series PT4-1 Element Performance PSID 1 Capacity BAR Q 5Q 1Q 2Q Capacity grams Flow vs. Pressure Loss* LPM PSID BAR GPM. Results typical from Multi-pass tests run per test standard ISO 15 gpm to 1 psid terminal - 1 mg/l BUGL. Refer to Appendix on pages for relationship to test standard ISO *Note: Pressure drop calculations are based on SAE-16 porting. 15

8 PT Series PT4-2 Element Performance PSID 1 Capacity BAR Q 5Q 1Q 2Q Capacity grams Flow vs. Pressure Loss* LPM PSID.5 BAR GPM. Results typical from Multi-pass tests run per test standard ISO 3 gpm to 1 psid terminal - 1 mg/l BUGL. Refer to Appendix on pages for relationship to test standard ISO *Note: Pressure drop calculations are based on SAE-16 porting. 16

9 PT Series PT4-3 Element Performance PSID 1 Capacity BAR Q 5Q 1Q 2Q Capacity grams Flow vs. Pressure Loss* LPM PSID.5 BAR GPM. Results typical from Multi-pass tests run per test standard ISO 45 gpm to 1 psid terminal - 1 mg/l BUGL. Refer to Appendix on pages for relationship to test standard ISO *Note: Pressure drop calculations are based on SAE-16 porting. 17

10 PT Series Specifi cations - PT2 Maximum Allowable Operating Pressure (MAOP): 15 psi ( 1.3 bar) Element Burst Rating: 15 psid Operating Temperatures: Buna: -4 F (-4 C) to 225 F (17 C) Materials: Tank Flange: aluminum Endcaps: nylon Drawings are for reference only. Contact factory for current version. 18

11 PT Series Specifi cations - PT4 Maximum Allowable Operating Pressure (MAOP): 15 psi ( 1.3 bar) Element Burst Rating: 15 psid Operating Temperatures: Buna: -4 F (-4 C) to 225 F (17 C) Materials: Tank Flange: aluminum Endcaps: nylon Drawings are for reference only. Contact factory for current version BUTTRESS 1/8-27 PTF 2 PLC'S REF. Ø4.6 PORT OPTIONS - SEE TABLE /16 (24MM) HEX TORQUE 2-24 IN-LBS Ø3.33 THRU. HOLE O-RING A A.9 DIA FLAT 5 PLC'S 6.2±.6 SINGLE 9.79±.6 DOUBLE `.6 TRIPLE n.345 ON A Ø5.5 B.C. 5 PLC'S EQ. SPACED 1/8-27 PTF 2 PLC'S.4 MIN CLEARANCE FROM TANK BOTTOM Ø3.9 SECTION A-A 19

12 PT Series PT2 Parts List INDEX PART DESCRIPTION PART NUMBER 1 PT2-1-2Q-25 psid bypass PT2-1-5Q-25 psid bypass PT2-1-1Q-25 psid bypass PT2-1-2Q-25 psid bypass PT2-2-2Q-25 psid bypass PT2-2-5Q-25 psid bypass PT2-2-1Q-25 psid bypass PT2-2-2Q-25 psid bypass PT2 DIE CAST SAE-12 ( UN-2B) PT2 DIE CAST SAE-16 ( UN-2B) PT2 DIE CAST 3/4 NPT ( NPTF-1) PT2 DIE CAST 1 NPT ( NPTF-1) PT2 DIE CAST G3/4 BSPF PT2 DIE CAST G1 BSPF O-RING /8-27 PIPE PLUG /8-27 PRESSURE GAUGE /8 NPT THREAD Linear measure = inches mm Pressure Switch (926923) 2

13 PT Series PT4 Parts List INDEX PART DESCRIPTION PART NUMBER 1 PT4-1-2Q-25 psid bypass PT4-1-5Q-25 psid bypass PT4-1-1Q-25 psid bypass PT4-1-2Q-25 psid bypass PT4-2-2Q-25 psid bypass PT4-2-5Q-25 psid bypass PT4-2-1Q-25 psid bypass PT4-2-2Q-25 psid bypass PT4-3-2Q-25 psid bypass PT4-3-5Q-25 psid bypass PT4-3-1Q-25 psid bypass PT4-3-2Q-25 psid bypass PT4 DIE CAST SAE-16 ( UN-2B) PT4 DIE CAST SAE-2 ( UN-2B) PT4 DIE CAST 1 NPT ( NPTF-1) PT4 DIE CAST 1 1/4 NPT ( NPTF-1) PT4 DIE CAST G1 BSPF PT4 DIE CAST G1 1/4 BSPF O-RING /8-27 PIPE PLUG /8-27 PRESSURE GAUGE /8 NPT THREAD Linear measure = inches mm Pressure Switch (926923) 21

14 PT Series How to Order Select the desired symbol (in the correct position) to construct a model code. Example: BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 PT2 1 1Q B G G S16 1 BOX 1: Filter Series 1 Symbol PT2 PT4 Tank top filter Tank top filter BOX 2: Element Length Symbol 1 Single 2 Double 3 Triple (Avail. on PT4 only) Consult factory for additional element lengths BOX 3: Media Code Symbol 2Q 5Q 1Q Microglass III, 2 micron Microglass III, 5 micron Microglass III, 1 micron BOX 4: Seals Symbol B V BOX 5: Indicator Symbol P G S Nitrile (NBR) Fluorocarbon (FKM) Port plugged Pressure Gauge, 25 psi Pressure Switch BOX 6: Bypass Symbol Pressure Setting G 25 PSI (1.7 bar) BOX 7: Ports Symbol G12 G16 N12 N16 S12 S16 G16 G2 N16 N2 S16 S2 PT2 G¾ BSPP G1 BSPP ¾ NPT 1 NPT SAE-12 SAE-16 PT4 G1 BSPP G1¼ BSPP 1 NPT 1¼ NPT SAE-16 SAE-2 2Q Microglass III, 2 micron BOX 8: Options Symbol 1 None W 2 Steel weld ring Notes: 1. The fi lters include the element you select already installed. 2. When W is selected in Box 8, the PT2 port options are N12 and S12 ; the PT4 port options are N16 and S16. Please note the bolded options reflect standard options with a reduced lead-time. Consult factory on all other lead-time options. Global products as identified are offered worldwide through all Parker locations and utilize a common ordering code. 22

15 KLT and KLS Series Tank Top Return Line Filters 23

16 KLT/KLS Series Tank Top Return Line Filters Applications for KLT and KLS Filters Mobile Equipment Construction, Refuse Industrial Power Units Machine Tool Oil Field Parker s new KLS /KLT Tank Top Return Line Filters are ideally suited for Mobile and Industrial high to medium fl ow return applications, from 3 to 12 GPM. This cost-effective, in-tank fi lter series provides maximum fl ow and dirt holding capacity for longer fi lter element life in a simple, easy-toinstall-and-service assembly. The generous element size with extensive media area ensures continuous fi ltration during cold start up conditions. The inside-to-out fl ow path with closed bottom provides additional assurance that all contaminants remain captured during element service removal. The fi lters have a pressure rating of 15 psi static, a temperature range of -4 F to 225 F, and are available in a wide range of high-effi ciency Microglass III media in 2, 5, 1 and 2 micron for all system cleanliness requirements. Bypass valves are built into the element to ensure further performance integrity. A new bypass is provided with each element change. This rugged design meets the needs for the demanding applications in mobile off -highway and onhighway applications for construction equipment, logging, refuse vehicles, mining, oil and gas recovery, marine, and industrial power units. Tank top mounted fi lter Feature Advantage Benefit Two-piece head and element construction perforated with metal outer wrap High effi ciency Microglass media maximizing fi ltration area Element design includes intergral disposable bypass valve with closed bottom end cap Magnetic prefi ltration Fill and gauge ports Saves space and reduces mounting hardware No bowl required Provides excellent fl ow diffusing, eliminating aeration Combines high particle capture effi ciency with high dirt holding capacity and lower P New bypass with each element change Ensures captured contaminants are removed with each element change Removes large ferrous contaminants Add fl uid through high performance fi lter media Gauge ports allow for added instrumentation 24 Lower cost, easy to integrate KLS model directly retrofi ts competitive housing Reduced cost and assembly weight Improved performance Cleaner fl uids, longer lasting with fewer service intervals Continuous fi ltration for cold start ups Lower operating costs Ensures reliable bypass performance No leakage Cleaner fl uids reduce risk for contamination during service Extends element life Visual indication of component wear Initial fl uid integrity extends system component life Monitor element life

17 KLT/KLS Series Specifi cations Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 15 psi (1.3 bar) Operating Temperatures: -4 F (-4 C) to 225 F (17 C) Element Burst Rating: 15 psid (1.3 bar) Filtration Rating: 2, 5, 1 & 2 Microns at Beta > 2 Element Condition Indicators: Gauge: -6 psi color coded Switch: SPDT 24 VDC and 25 VAC Materials: Head & Cover: Cast Aluminum Alloy Bypass Valve: Nylon Filter Media: Microglass III Element End Caps: Nylon Weights (approximate): KLT lbs. (1.36 kg) KLT lbs. (1.81 kg) KLT(S) lbs. (3.63 kg) KLT(S) lbs. (4.54 kg) KLT Weld Plate Drawings B 3.4 (86) ¼ NPT THREAD B 18. (457) WIRE LEADS COMMON BLACK N.O. : RED N.C. : GREEN ½ NPT CONDUIT CONNECTION THREAD A 18 TO 22 PSI (YELLOW FIELD) 22 TO 6 PSI (RED FIELD) 1.6 (27) 1.89 (48) C 2.8 (53).55 (14) SQ. D HOLE IN RESERVOIR TO 18 PSI (GREEN FIELD) ¼ NPT THREAD Linear Measure: inch (mm) Dimension KLT Filter Model KLT-2/KLT-4 KLT-7/KLT-8 A 5/16-18 UNC-2A 3/8-16 UNC-2A B 5.33 (135) 7.15 (182) C 1. (25) 1. (25) D 4.5/3.75 (114/95) 6.25/5.5 (159/14) Drawings are for reference only. Contact factory for current version. 25

18 KLT Series Dimensional Drawings KLT 2 / KLT 4 KLT 7 / KLT (68) 3.54 (9) TORQUE: 3 FT-LB (4 N-m) TORQUE: 7 FT-LB (1 N-m) 4.72 (12) TYP SAE-16 STRAIGHT THREAD O-RING PORT 6.54 (166) TYP. SAE-24 STRAIGHT THREAD O-RING PORT.35 (9) DIA. MOUNTING HOLES (4 PLACES) ON 4.96 (126) B.C. RECOMMENDED HEAD TO TANK TORQUE: 11 FT-LB (15 N-m).43 (11) DIA. MOUNTING HOLES (4 PLACES) ON 6.89 (175) B.C. RECOMMENDED HEAD TO TANK TORQUE: 3 FT-LB (4 N-m) C MIN. SERVICE CLEARANCE 2.83 (72) ¼ NPT PLUGGED GAUGE PORT(S) (3 PLACES) C MIN. SERVICE CLEARANCE 3.66 (93) ¼ NPT PLUGGED GAUGE PORT(S) (3 PLACES) 1.42 (36) 1.1 (28) D D RESERVOIR CUTOUT DIAMETER RESERVOIR CUTOUT DIAMETER L L Linear Measure: inch (mm) Drawings are for reference only. Contact factory for current version. Dimensions KLT Filter Model KLT-2 KLT-4 C 5.75 (146) 9.5 (241) L 4.16 (16) 7.75 (197) D 3.6 (93) 3.56 (9) Dimensions KLT Filter Model KLT-7 KLT-8 C 13. (33) (489) L (291) 17.7 (45) D 5.36 (136) 5.26 (133) 26

19 KLT Series Dimensional Drawings KLS 7 / KLS (86).43 (11) DIA. MOUNTING HOLES (4 PLACES) ON 6.25 (158.8) B.C. RECOMMENDED HEAD TO TANK TORQUE: 3 FT-LB (4 N-m) 6.76 (172) TORQUE: 12 FT-LB (16 N-m) C MIN. SERVICE CLEARANCE SAE-24 STRAIGHT THREAD O-RING PORTS (BOTH SIDES) 3.62 (92) 1.62 (41) ¼ NPT PLUGGED GAUGE PORTS (2 PLACES) D RESERVOIR CUTOUT DIAMETER L Linear Measure: inch (mm) Dimensions KLS Filter Model KLS-7 KLS-8 C 13. (33) (489) L (291) 17.7 (45) D 5. (127) 4.8 (122) Drawings are for reference only. Contact factory for current version. 27

20 KLT Series Dimensional Drawing KLT with 2 Port 5/16-18 UNC-2B TAP THRU. 4 PLC'S 1/4" NPT 3 PLC'S 3.62 REF REF REF..844 REF REF REF. Ø PLC'S EQUALLY SPACED 1/2-13 UNC-2B Drawings are for reference only. Contact factory for current version. 28

21 KLT Series KLT-2 Element Performance Beta Rating 1 Efficiency Efficiency % 2Q 5Q 1 1Q Q Micron Size (c) Multipass tests 15 gpm to 25 psid terminal - 1 mg/l BUGL Flow vs. Pressure Loss 29

22 KLT Series KLT-4 Element Performance Beta Rating 1 Efficiency Efficiency % 2Q 5Q 1 1Q Q Micron Size (c) Multipass tests 3 gpm to 25 psid terminal - 1 mg/l BUGL Flow vs. Pressure Loss 3

23 KLT/KLS Series KLT/KLS-7 Element Performance Beta Rating 1 Efficiency Efficiency % 2Q 5Q 1 1Q Q Micron Size (c) Multipass tests 5 gpm to 25 psid terminal - 1 mg/l BUGL Flow vs. Pressure Loss 31

24 KLT/KLS Series KLT/KLS-8 Element Performance Beta Rating 1 Efficiency Efficiency % 2Q 5Q 1 1Q Q Micron Size (c) Multipass tests 7 gpm to 25 psid terminal - 1 mg/l BUGL Flow vs. Pressure Loss 32

25 KLT/KLS Series KLT with 2 Port - Element Performance Effi ciency Beta Rating Efficiency % 1 2Q 1 5Q 1Q Q Micron Size (c) Flow vs. Pressure Loss LPM SUS 16. 2Q PSID BAR 5Q Q Q GPM 33

26 KLT and KLS Series Operating and Maintenance Instructions A. Mounting 1. Standard mounting. a. Cut proper size hole in the top of the reservoir. b. Drill holes for studs within the proper bolt circle. c. Set the fi lter into the cutout hole and secure with proper size bolts, nuts and lock washers. d. Torque nuts in accordance with drawing. 2. Mounting procedure using weld plate. a. Rough cut proper size hole in the top of reservoir. b. Weld the weld plate concentric to the rough cut hole. c. Mount the fi lter onto the studs and secure with nuts and lock washers. d. Torque nuts in accordance with drawing. 3. Utilize proper fi ttings. B. Start-Up 1. Check for and eliminate leaks upon system start-up. 2. Check differential pressure indicator, if installed, to monitor element condition. C. Service 1. An element must be serviced when the indicator indicates service is required. NOTE: If the fi lter is not equipped with an indicator, the element should be serviced according to machine manufacturer s instructions Index Parts List D. Servicing Dirty Element 1. Shut system down to assure that there is NO PRESSURE OR FLOW into the fi lter housing. 2. Remove the fi lter cover. 3. Remove and discard the contaminated element cartridge. E. Before Installing a New Element Cartridge 1. Clean the magnetic core with a lint-free cloth. 2. Check all seals and replace if necessary. F. To Install a New Element Cartridge 1. Lubricate all seals. 2. Mount new fi lter cartridge. 3. Re-install the cover. 4. Torque the cover nuts per drawing. Part Number 1 Cover Assembly (Includes Cover o-ring) Quantity KLT2/KLT KLT7/KLT KLS7/KLS Cover o-ring KLT2/KLT4, Nitrile N KLT2/KLT4, FKM V KLT7/KLT8, Nitrile N KLT7/KLT8, FKM V KLS7/KLS8, Nitrile N KLS7/KLS8, FKM V Element (see How to Order page) 4 Filter Head (Includes gauge plugs & studs) KLT2/KLT4 (S16) KLT7/KLT8 (S24) KLS7/KLS8 (S24) KLS7/KLS8 (2 Flange) Tank Gasket Not Shown KLT2/KLT4 18x98x5.5B 1 KLT7/KLT8 152x136x6B 1 KLS7/KLS8 (O-Ring) N72355 (C.F.) 1 Weld Plate KLT2/KLT KLT7/KLT Not Shown Pressure Switch NS-1C-19R/EL 1 Not Shown Pressure Gauge C.F. = Consult Factory Perform procedures B1 and B2 to ensure no leaks are present. 34

27 KLT and KLS Series How to Order Select the desired symbol (in the correct position) to construct a model code. Example: BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 KLT 7 1Q B P G S24 1 BOX 1: Filter Series Symbol KLT KLS Single port return-line filter Dual port return-line filter (-7 and -8 models only) BOX 2: Filter Model Symbol 2 3 GPM (115 l/m nominal flow) 4 5 GPM (19 l/m nominal flow) 7 1 GPM (38 l/m nominal flow) 8 12 GPM (455 l/m nominal flow) BOX 3: Media Code Symbol 2Q 5Q 1Q 2Q WR Microglass III, 2 micron Microglass III, 5 micron Microglass III, 1 micron Microglass III, 2 micron Water Removal BOX 4: Seals Symbol B V BOX 5: Indicator Symbol P G S Nitrile (NBR) Fluorocarbon *NOTE: Nitrile tank gasket always supplied. No indicator; plugged pressure port(s) Pressure gauge, -6 psig Pressure switch BOX 6: Bypass Symbol Pressure Setting G 25 psid (1.7 bar) BOX 7: Ports Symbol BOX 8: Options Symbol 1 None TP KLT-2/4 S16 SAE-16 (1 5/16-12) KLT-7/8 S24 SAE-24 (1 7/8-12) N24 Y32 1 1/2 NPT 2 Code 61 Flange Face KLS-7/8 S24 2 x SAE-24 (1 7/8-12) N24 2 x 1 1/2-NPT Weld plate (KLT only) Replacement Elements Element Nitrile Fluorocarbon Code Q Q Q Q Q Q Q Q Q 1Q Q 93697Q Q Q Q Q Q 93728Q 5Q Q Q Q Q Q Q Q Q 2Q Q Q Q Q Q 93727Q Q Q WR C.F. C.F. C.F. C.F. C.F. = Consult Factory Global products as identified are offered worldwide through all Parker locations and utilize a common ordering code. 35

28 Moduflow Low Pressure Filters Series 36

29 Moduflow Applications Series - Power Unit Fabrication - Off-line Filter Loops - Mobile Equipment The Moduflow filter is widely considered the most versatile filter available on the market. The patented end cap minimizes turbulence and pressure loss through the filter, improving system performance. The newly designed closed bottom elements for the RFP and ILP models insures all contamination remains trapped within the element as the filter is serviced. A wide variety of visual and electrical indicators allows you to know exactly when the element needs to be serviced. There is even a no element indicator that can sense when there is not an element installed in the filter. From top to bottom, the Moduflow filter series provides the high level of filtration and long term dependability so vital to today s hydraulic systems. Parker s new patented Moduflow element was designed with built-in diverter and bypass valve, to meet your application needs. Mounting / Porting Styles RFP Return Filter ILP In-Line Filter RETURN OUT FILTER HEAD IN BOWL TANK BOWL OUTLET PORT 37

30 Moduflow Features Series Flanges - NPT or SAE ¾ to 2 - Lightweight aluminum Cover - Slotted for quick release - Lightweight aluminum Indicators - Visual or electrical - Mounted on either side - Standard no element indication Bowl - Single or double length - Durable steel construction Bypass (not visible) - Integral 35 psi bypass replaced with every element change Element (not visible) - Available in high performance Microglass III media - Single or double length Top access element service Slotted cover Closed bottom elements Feature Advantage Benefit Oil remains in housing Quicker elements change Quick release cover Cap screws remain in housing Removes all contaminant during element service No Spills Reduced maintenance costs Reduced maintenance costs No loose parts to lose No downtime contamination from servicing Visual or electrical indicators Know exactly when to service elements Helps prevent bypass condition No premature disposal Flange face ports Flexible mounting (3/4 to 2 ) Easy plumbing to your system 38

31 Moduflow Series RFP-1 and ILP-1 Element Performance Beta Rating 1 1 2Q Efficiency 5Q 1Q Efficiency % 99.9 PSID 5 4 Capacity 2Q 5Q 1Q 2Q BAR Q Micron Size (c) Capacity grams. Multipass tests 4 gpm to 5 psid terminal - 5mg/L BUGL LPM Flow vs. Pressure Loss LPM SUS 2Q 5Q SUS Empty Housing.6.5 PSID Q 2Q BAR PSID SAE flange BAR GPM GPM 39

32 Moduflow Series RFP-2 and ILP-2 Element Performance Beta Rating 1 1 2Q Efficiency 5Q 1Q Efficiency % 99.9 PSID 5 4 Capacity 2Q 5Q 1Q 2Q BAR Q Micron Size (c) Capacity grams. Multipass tests 8 gpm to 5 psid terminal - 5mg/L BUGL Flow vs. Pressure Loss LPM LPM SUS SUS Empty Housing.6.5 PSID Q 5Q.8.6 BAR PSID BAR 4 1Q 2Q SAE flange GPM GPM 4

33 Moduflow Specifi cations: RFP, ILP Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 2 psi (13.8 bar) Design Safety Factor: 2:1 Rated Fatigue Pressure: 15 psi (1.3 bar) Element Burst Rating: 7 psid (4.8 bar) Filter Materials: Head, Cover, Flanges: die cast aluminum Bowl: steel Operating Temperatures: Nitrile: -4 F to 225 F (-4 C to 17 C) Fluorocarbon: -15 F to 275 F (-26 C to 135 C) Weight (approximate): Single: 2 lbs. (9.1 kg) Double: 25 lbs. (11.3 kg) Indicators: Visual (optional) Electrical (optional) 25VAC 125 VDC Electrical ( D option) 25VAC / 28 VDC Color Coding: White (normally closed) Red (normally open) Black (common) ILP OUTLET OPTIONAL 3-PIN MALE RECEPTACLE Series MINIMUM ELEMENT REMOVAL CLEARANCE Single: Double: Dimensions: mm inch Model A B C D RFP-1 with optional 2 fitting RFP-1 without optional 2 fitting RFP-2 with optional 2 fitting RFP-2 without optional 2 fitting ILP ILP _ _ Drawings are for reference only. Contact factory for current version _ _ N/A N/A A OPTIONAL PORT FLANGE IL & RF INLET Linear Measure: millimeter inch C OPTIONAL BMOUNTING BRACKET OPTIONAL TANK FLANGE (99 OPTION) RFP-1 OUTLET RFP OUTLET D 2-11½ NPTF OPTIONAL FITTING 41

34 Moduflow Series Drawings Specifi cations: DILP Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 2 psi (13.8 bar) Design Safety Factor: 2:1 Rated Fatigue Pressure: 15 psi (1.3 bar) Element Burst Rating: 7 psid (4.8 bar) Filter Materials: Diverter Valve Assembly: die cast aluminum Check Valve Assembly: die cast aluminum Filter Assembly: see IL2 specifications Operating Temperatures: Nitrile: -4 F to 225 F (-4 C to 17 C) Fluorocarbon: -15 F to 275 F (-26 C to 135 C) Weight (approximate): Single: 55 lbs. (24.9 kg) / Double: 65 lbs. (29.5 kg) Indicators: Visual (optional) Electrical (optional) 25VAC 125 VDC Electrical ( D option) 25VAC / 28 VDC Color Coding: White (normally closed) Red (normally open) Black (common) FILTER SCHEMATIC FILTER BYPASS OUTLET FILTER BYPASS OPTIONAL FLANGE INLET ¼-18 NPT DRAIN VENT CONNECT TO TANK are for reference only. Contact factory for current version Linear Measure: millimeter inch AIR BLEED EACH FILTER ½-13 SHCS TORQUE FT-LB OUTLET SINGLE DOUBLE INLET DRAIN VENT OPTIONAL MECHANICAL INDICATOR Torque (Ft-Lbs) BOTH CHECK VALVES MOVE SAME DIRECTION Approximate handle torque required for changeover System Pressure (psi) BAR PSID DIFF. PRESSURE Typical Flow/Pressure Curves For Duplex Valves (Add to differential pressure of filter assembly for total duplex pressure differential) *Diverter/check valves combined 3 SUS 2 SUS GPM FLOW LP M

35 Moduflow Specifi cations Series For return line applications (RFP), the fluid returning to the reservoir holds the check valve open. When the system is shut down, the check valve closes automatically Check Valve Flow/Pressure Drop *Check valve pressure drop must be added to assembly pressure drop to get total Pressure Loss (psid) Flow (GPM) Linear Measure: millimeter inch RFP SINGLE ELEMENT RFP DOUBLE ELEMENT Drawings are for reference only. Contact factory for current version MAX. O.D OVER WELD (RFP & DOUBLE LENGTH) 43

36 Moduflow Specifi cations Series Lower Cost than many single unit filters. Moduflow Manifold Extended Filter Range Use Model MM Manifold to handle return line flows up to 13 gpm. Rated static pressure: 3 psi Typical burst pressure: 9 psi Easily mounted on ModuFlow High Flows At Low Cost The model MM manifold is designed to extend the flow range of ModuFlow TM Filters when operating with 1 Micron and finer filter media. When mounted to a pair of RFP-2 or ILP-2 filters, this manifold will allow flows up to 13 gpm in return lines (15 fps velocity). Note: The Model MM manifold is not applicable to suction lines due to its pressure drop characteristics. When used with two ModuFlow TM filters, the total cost is often less than a single unit filter rated for 13 gpm flow. Tank-top mounted (Model RFP) filters will require only one manifold on the filter inlet pports. In-line mounted (Model ILPav) filters will require two manifolds, one on the inlet and one on the outlet ports Proven Reliability The rugged design of the Model MM manifold has been proven in demanding mobil equipment applications, At the factory, we have cycle tested the Model MM through the full range of rated flow and pressure to insure reliable service. Parker Filter Division maintains the same high standards in delivery, quality, and service. Considering this, plus features, flexibility, price, and performance, the Model MM manifold is a valuable addition to your fluid power component list. FLOW/PRESSURE CURVE (PSI) DIFF. PRESS. (BAR ) TYPICAL FLOW/PRESSURE CURVES FOR SUS MODEL MM 38B6 Multiple Uses Although designed for manifold ModuFlow TM filters, the Model MM can be used in a variety of applications which require: Splitting flow between components (GPM) INLET FLOW (LPM) Such applications are frequently encountered on mobile equipment, machine tools, and large lubricating systems. In such applications, use of a manifold can often reduce total piping and installation costs. 44

37 Moduflow Specifi cations Series MANIFOLD SPECIFICATIONS Rated Static Pressure, maximum: 2.7 bar (3 psi) Typical Burst Pressure: 62.1 bar (9 psi) Operating Temperature (Buna seals): +121ºC to 4ºC (+25ºF to 4ºF) HOW TO ORDER MANIFOLDS: Part Number Moduflow Manifold Housing Material: ANSI 356-T6 cast aluminum Approximate Shipping Weight: 3.6 kg (8 lbs) Porting: See Options Below Order Screws and O-Rings Seperately: Inlet & outlet screws (12 required): Order P/N 9228 Outlet port o-rings (2 required): Nitrite: Order P/N N72228 Fluorocarbon: Order P/N V92228 * Tank-top mounted RFP filters will require one manifold on filter inlets: in-line mounted ILP filters will require two manifolds on both inlets and outlets. 12.7mm mm mm mm 3.5 INSTALLATION DIMENSIONS 155.6mm mm mm 3.62 (TORQUE SCREWS TO FT-LBS) 42.9mm mm mm 3.62 (TORQUE SCREWS TO FT-LBS) 66.8mm 2.63 VIEW AT C-C 273.8mm 1.78 STANDARD OUTLET, 2 PLS 2- SAE 4-BOLT FLANGE WITH O-RING GROOVE Drawings are for reference only. Contact factory for current version. C C TOLERANCES To one decimal place: To two decimal places: 3.mm.12.8mm.3 To three decimal places:.4mm.15 Linear Measure: Millimeter Inch 45

38 Moduflow Accessories Series Linear Measure: millimeter inch M OPTION-VISUAL INDICATOR, NO ELEMENT WARNING OPTIONAL MOUNTING BRACKET (92494) DIA. THRU PLACES TYP R DIA. THRU 4 PLACES DIA. THRU TYP Drawings are for reference only. Contact factory for current version E OPTION-ELECTRICAL INDICATOR 46

39 Moduflow Parts List Series Size Flange Kits (flange, 4 bolts, o-ring) Part Number Code Buna Fluorocarbon ¾ inch NPTF YB inch NPTF YC ¼ inch NPTF YD ½ inch NPTF YE inch NPTF YF SAE - 12 YM SAE - 16 YN SAE - 2 YO SAE - 24 YP BLANK FLANGE RFP / ILP / DILP Replacement Elements Nitrile Seals Fluorocarbon Seals Media New Single Replaces Old Single New Double Replaces Old Double New Single Replaces Old Single New Double Replaces Old Double 2Q Q Q Q Q 93741Q Q 93745Q Q 5Q Q Q Q Q 93742Q 93269Q 93746Q Q 1Q Q Q Q Q 93743Q Q 93747Q Q 2Q Q Q 9374Q Q 93744Q Q 93748Q Q WR

40 Moduflow Parts List Series Index Part No. Quantity 1 Screws, Nameplate Name Plate, Unstamped Cover Screws, 5/16-18 UNC x Bowl Screws, 5/16-18 UNC x Cover, Without nameplate O-Ring, cover Nitrile... Fluorocarbon... 7 Element Seal Nitrile... Fluorocarbon... Filter Assembly Exploded View 6 N7235 V Element... Refer to Table 1 9 Head, Machined only... 2 SAE Flange 1½ SAE Flange 1½ NPTF 1 Bowl, Select desired model ILP-1... ILP-2... RFP-1... RFP-1 with 2 inch NPTF fitting... RFP-2... RFP-2 with 2 inch NPTF fitting Index Part No. Quantity 11 Check Valve Assy Flange Kits... O-Ring 13 Plug Kit, Fastener, self-sealing, o-ring seal included with fastener 14 Indicator Electrical 35 psid psid, 3-pin male receptacle... Gasket O-Ring 15 Indicator Visual 35 psid 4-band... Bracket, Inline mounting... Indicator Kit, Remote mount Not Shown Not Shown Changeover Valve Assy., Duplex Check Valve Assy., Duplex... Drain Plug, SAE-24 for RFP model Nitrile... Fluorocarbon... O-Ring between tank and bowl Refer to Table V V N72265 Optional 2 2 Optional Optional Optional Optional Optional Drawings are for reference only. Contact factory for current version. 48

41 Moduflow How to Order Series BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 ILP 1 1Q B MP 35 Y9Y9 1 BOX 1: Filter Series Symbol RFP ILP DILP BOX 2: Element Length Symbol 1 Single Return-line filter, inlet on side outlet on bottom In-line filter In-line duplex 2 Double BOX 3: Media Code Symbol 2Q 5Q 1Q 2Q WR BOX 4: Seals Symbol B E V Microglass III, 2 micron Microglass III, 5 micron Microglass III, 1 micron Microglass III, 2 micron Water Removal Nitrile EPR Fluorocarbon BOX 5: Indicator Symbol P M E D Note: First letter of indicator code = left side of filter head when looking into inlet with bowl down; second letter = right side of filter head when looking into inlet with bowl down. BOX 6: Bypass Setting Symbol Pressure ports drilled & plugged only; no indicator Visual indicator w/ no element warning Electrical indicator only Electrical indicator only, 3-pin male receptacle psid BOX 7: Port Options Filter Model Inlet Symbol/ Y9 2 flange face 99 No fitting RFP P9 SAE-24 integral threads Y9 2 flange face Y9 2 flange face 1) First pair of symbols denotes inlet for all filter styles; second pair of symbols denotes outlet. 2) Four symbols required: two for inlet, two for outlet. 3) Unused ports in filters come plugged with a blank flange. 4) See Flange Kits table for port flange options. Flange Kits are ordered separately. F9 F8 2 NPTF External check valve Y9 2 flange face Y9 2 flange face ILP P9 SAE-24 integral threads DILP BOX 8: Options Symbol 1 None Outlet Symbol/ P9 E9 SAE-24 integral threads 1½ NPTF integral threads 49

42 Moduflow TFP Series 3.24 [82.4] Bowl-less Design INLET FLANGE KIT ACCESSORY 1.19 [3.2] 6.62 [168.1] COVER 5/16-18 UNC HEX HEAD COVER SCREW TORQUE TO 16-2 FT-LBS 3.6 [77.8] 3.18 [8.7] 2.47 [62.7] INLET [63.] INLET CONFIGURATION: 2 SAE FLANGE FACE (REF. SAE J518 CODE 61) WITH INTEGRAL SAE-24 (1 7/8-12 UN-2B THREAD) O-RING BOSS PORT (REF. SAE J1926/1) TANK MOUNTING SURFACE (.1 MIN. FLATNESS REQUIRED FOR SEAL) 4.7 [119.4] TANK HOLE RECOMMENDED (5. [127.] MAX ALLOWED) FLANGE SEAL P/N N72251 (SIZE 2-251) [39.6] TFP [545.1] TFP-2.5 [12.7] MIN INSTALLATION CLEARANCE TANK BOTTOM SURFACE BYPASS FLOW DIA TANK MOUNT HOLES 4-TOTAL ON 6.75 BOLT CIRCLE BOTTOM VIEW Features Advantages Shorter port-to-port distance. Direct tank mount capability eliminates need for adaptor flanges and bowl. Standard head incorporates 2 SAE flange face with integral SAE-24 port configuration. Filter head and element 2-piece construction requires no filter bowl. Patented element design with integral bypass valve and inside to out flow path. Provides a smaller footprint and reduced weight. Aluminum die cast head reduces weight and direct tank mount flange reduces installation time and cost. Enables one common head to be used. Simplifies ordering model code. Reduces assembly cost by 25%. 5 Ensures all contaminants remain captured during service. New bypass valve with each element ensures operation reliability.

43 Moduflow How to Order TFP Series BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 TFP 1 1Q B MP 35 C32 1 BOX 1: Series Symbol TFP TFPW Box 2: Element Length Symbol 1 Single 2 Double Box 3: Media Code Symbol 2Q 5Q 1Q 2Q WR Return-line filter Return-line filter anodized for HWHC fluid Microglass III, 2 micron Microglass III, 5 micron Microglass III, 1 micron Microglass III, 2 micron Water Removal BOX 5: Indicator Symbol P M E D Pressure ports drilled & plugged only; no indicator Visual indicator w/ no element warning Electrical indicator only Electrical indicator only, 3-pin male receptacle Note: Two letters are required for the indicator code (e.g. MP ) BOX 6: Bypass Symbol (2.4 bar) psid BOX 8: Ports Symbol C32 BOX 8: Options Symbol 1 None 2 SAE flange face/sae- 24 combination inlet port BOX 4: Seals Symbol B E V Nitrile EPR Fluorocarbon Media Nitrile TFP-1 Fluorocarbon Replacement Elements Ethylene Propylene Media Nitrile TFP-2 Fluorocarbon 2Q Q 93741Q Q 2Q Q 93745Q Q 5Q Q 93742Q Q 5Q Q 93746Q Q 1Q Q 93743Q Q 1Q Q 93747Q Q 2Q Q 93744Q Q 2Q 9374Q 93748Q Q WR N/A WR N/A Ethylene Propylene 51

44 RF7 Series Low Pressure Filters 52

45 RF7 Series Applications - Mobile equipment - Power unit fabricators - Off-line filter loops The Parker RF7 filter is designed for those applications where depend able, yet economical, return line system protection is required. The in-tank mounting design makes the RF7 ideally suited for use by power unit fabricators and mobile equipment manufacturers...or anyone who views equipment space at a premium, but not at the expense of performance. Element Condition Indicator - True pressure differential - Know, at a glance, when to change the filter element - Gauge also available Two-Piece Construction (Head/Tube) - Easy in-tank mounting Diffuser Tube - Disperses return flow below reservoir fluid level - Prevents fluid aeration - Closed bottom provides for even fluid dispersal - Prevents objects from falling into the reservoir during element servicing Bypass Valves - Virtually zero leakage - Multiple valves for high flow Vent - For variable displacement pump applications Cartridge/Element Handle - Easy to remove entire assembly for servicing Bypass Filter Screen - Prevents gross contamination from passing through the filter even during bypass 53 Cover Lock-Band with T Handle - Easy access for servicing - No loose parts to remove and handle - No special tools required for removal

46 RF7 Series Element Features Inside each Parker Filter... a quality Parker Element The important item in a filter assembly is the element. It has to capture and hold contaminants that can damage or stop a machine...while at the same time allowing the required flow of clean fluid so the machine can function properly. There are many ways to design and build an element, and it s easy to produce a low cost element. However, cost is not a good selection criteria... especially when the risk is loss of critical performance. For instance, consider wire mesh reinforcement. Not all filter elements have it. It s used in Parker elements to keep the pleats from collapsing or bunching. If pleats bunch, the effective surface area of the element is reduced, excessive pressure drop develops, and the filter assembly may go into the bypass mode. This condition wastes energy and allows unfiltered fluid flow back into the system, effectively shortening filter life. Gasket Ring Seal - Positive sealing for optimum element efficiency Protective Perforated Cylinder - Necessary for inside-to-outside flow - Prevents media blow out Wire Reinforced Media (Not Visible) - Prevents pleat bunching - Helps prevent media migration - Maintains media efficiency Engineered Element Design - The right combination of pleat depth and number of pleats means lower pressure losses (longer life) - Dirt holding capability is maximized for less frequent element change-out Elements for Every Application - Standard Microglass III media for long life and excellent system protection - Economical cellulose elements also available Tank mounted design. Features Advantage Benefits Saves space and reduces hardware requirements. 54 Easy to integrate into system design. Cover fill port. Allows 1% filtration of all new system oil. Eliminates contamination before it can cause problems. High flow capacity. One filter may handle all return line flows. Cost savings in filters and hardware. Broad range of filter media available including water removal. Inside-to-outside flow through element with a closed bottom end cap. Wire reinforced Microglass III elements. Multipass tested elements (per ANSI/NFPA T R1-199 modified for fine filtration). Complete element performance data disclosure. Choose the proper medium for system parameters. All contamination is trapped inside of element assembly. Rugged construction stands up to abuse of cyclic flows without performance loss. Wire support reduces pleat bunching, keeps pressure drop consistent. Filter performance backed by recognized and accepted laboratory test standards. All pertinent information is provided in an easy-to-compare format. Cost savings by avoiding both over and under filtration. Contamination is not reintroduced into the system during replacement. The reliable filtration provided assures equipment protection, reduces downtime, maximizes element life, and allows the hydraulic system to operate properly. Filters you select have consistent performance levels. Provides an easy guide to proper filter selection.

47 RF7 Series RF7-1 Element Performance Beta Rating 1 Efficiency Efficiency % PSID 5 Capacity BAR Q 5Q 1Q 2Q Q 5Q 1Q 2Q Micron Size (c) Capacity grams. Results typical from Multi-pass tests run per test standard ISO 5 gpm to 5 psid terminal - 1 mg/l BUGL Refer to Appendix on pages for relationship to test standard ISO LPM Flow vs. Pressure Loss LPM PSID Q 5Q 1Q 2Q BAR PSID Empty Housing BAR GPM GPM 55

48 RF7 Series RF7-2 Element Performance Beta Rating 1 2Q 1 Efficiency 5Q 1Q Efficiency % 99.9 PSID 5 4 Capacity 2Q 5Q 1Q 2Q BAR Q Micron Size (c) Capacity grams. Results typical from Multi-pass tests run per test standard ISO 8 gpm to 5 psid terminal - 1 mg/l BUGL Refer to Appendix on pages for relationship to test standard ISO LPM Flow vs. Pressure Loss LPM SUS 2Q SUS.6.5 PSID Q 1Q 2Q BAR PSID Empty Housing BAR GPM GPM 56

49 RF7 Series Specifi cations Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 15 psi (1.3 bar) Design Safety Factor: 3:1 Element Burst Rating: 5 psid (3.4 bar) minimum. Materials: Cast Aluminum Head & Cover Steel Diffuser Tube Steel Clamp Note: Optional v ent f or va ri ab le displacement pump applications ava ila bl e on co v er (not sho wn. ) RF Operating Temperatures: Nitrile; -4 F to 225 F (-4 C to 17 C) Fluorocarbon; -15 F to 275 F (-26 C to 135 C) Weight (approximate): RF lbs. (15.4 kg) RF lbs. (19 kg) RF ELEMENT REMO VA L CLEARANCE INLET (STANDARD) HAND TIGHTEN ONLY Indicators: Visual system pressure type (gauge or pressure switch). Visual pressure differential type. Electrical pressure differential type VDC DIA. MOUNTING HOLES 4 TOTAL EQUALLY SPACED ON DIA. B.C. SECOND INLET (OPTIONAL) SQ MECHANICAL I NDICA TO R (OPTIONAL- LEFT SIDE SHO WN) INLE T MAX MAX MOUNTING GASKET ELECTRICAL INDICATOR (OPTIONAL RIGHT SIDE SHOWN) DIA. VENT HOLE RF RF DIA /2-13 UNC X.81 MIN FULL THD DEPTH 4-PLACES 2" SAE J518 CODE 61 FLANGE FACE DIA /2-13 UNC X.94 MIN FULL THD DEPTH 4-PLACES 2 1/2" SAE J518 CODE 61 FLANGE FACE O UT LE T DIA. Clearance hole in tank reser vo ir to be 7 1/8 IN. + 1/16 IN. DIA. Linear Measure: millimeter inch Dimensions are intended for reference only. Drawings are for reference only. Contact factory for current version. 57

50 RF7 Series Specifi cations Filter Service When servicing an RF7 filter, use the following procedure: A. Stop all flow to the filter. B. Loosen the clamp handle counterclockwise and remove the clamp assembly. C. Remove the filter cover by lifting upward. D. Pull the entire cartridge assembly out by grabbing onto the T handle. E. Unscrew the T handle from the bypass assembly (with mesh screen) and remove the bypass assembly. F. Lift the element over the exposed rod assembly and discard. G. Place a new element over the rod and seat on the bottom. H. Re-attach the bypass assembly to the top of the element. I. Replace the T handle and hand-tighten. J. Firmly place the entire cartridge assembly back into the filter housing. K. Set the cover back on the housing, reattach the clamp assembly and hand tighten the handle Parts List Index Part Number RF7-1 RF7-2 1 Head - Single Inlet 2 SAE Flange Face w/gage ports /2 SAE Flange Face w/gage ports SAE Flange Face w/indicator /2 SAE Flange Face w/indicator Head - Double Inlets 2 SAE Flange Face w/gage ports /2 SAE Flange Face w/gage ports SAE Flange Face w/indicator /2 SAE Flange Face w/indicator Cover Bypass Mount Lipseal Nitrile Fluorocarbon Bypass Valve (6) Screen Screen Retaining Ring T Handle Assembly Clamp Clamp Handle Cover O-Ring Nitrile N72263 N72263 Flourocarbon V72263 V Element (See model code page) 13 Cartridge Rod Assembly Diffuser Tube Assembly Gasket Nitrile Fluorocarbon Nameplate Drivescrew (2) Pressure Gauge Indicators Visual Electrical

51 RF7 Series How to Order BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 RF7 2 1Q MP 25 Y999 1 BOX 1: Seals Symbol None F3 BOX 2: Basic Assembly Symbol RF7 BOX 3: Length Symbol Nitrile Fluorocarbon In-tank return fi lter 1 Single length 2 Double length BOX 5: Indicator(s) Symbol (2 Required) P G S M E (See Note A) Gauge, port plugged Gauge, color coded Pressure switch Visual indicator Electrical indicator Note A: (First letter of indicator code = left side of fi lter head when looking into inlet with bowl down; second letter = right side of fi lter head when looking into inlet with bowl down.) BOX 7: Ports Symbol Inlet Y9 Z9 Side 2 SAE flange face (Standard) 2½ SAE flange face (Standard) 2Y9 Two Inlets, 18 apart (Optional) 2Z9 Two Inlets, 18 apart (Optional) Outlet 99 No fitting BOX 4: Media Code Symbol BOX 6: Bypass Setting Symbol BOX 8: Modifications Symbol 2Q Microglass III psid 1 None 1Q Microglass III 5Q Microglass III 2Q Microglass III 1C Cellulose WR Water Removal Replacement Elements Media Single Length Double Length Nitrile Fluorocarbon Nitrile Fluorocarbon 2Q 9338Q 93388Q Q Q 1Q 93382Q 93389Q Q Q 5Q 93384Q 93381Q Q Q 2Q 93386Q Q Q Q 1C WR Please note the bolded options refl ect standard options with a reduced lead-time. Consult factory on all other lead-time options. 59

52 BGT Series Low Pressure Filters 6

53 BGT Series Applications - Flows to 64 GPM - 3 Micron Absolute to 12 Micron Absolute - Disposable or Recleanable Elements - Visual and Electrical Indicators - Microglass elements - Magnetic prefiltration - Full flow bypass valve - No internal leakage paths - Inside-to-out flow thru element - Complete contaminant removal during element service - LEIF element (6 and 1 Series only) Specifications Housing Data: Material: Head Aluminum Alloy Diffusor Steel Internals Carbon Steel and Aluminum Seals Nitrile (Standard), Fluorocarbon Pressure Rating: Static 15 psi (1.3 bar) Temperature Range: Operating -4 F to +25 F (-4 C to +12 C) BGT Tank Mounted Return Flow Filters Filtration begins with magnetic prefiltration of ferromagnetic particles in the full fluid flow upstream of the element, not downstream or in the reservoir. Built-in or system generated ferromagnetic wear debris (even particles smaller than the element rating) are collected by the high strength (3.K Gauss) magnetic column. This results in extended element and oil life and reduced maintenance and downtime, which reduces overall operating cost. elements of several contamination class levels for use in all common fluids. Optional accessories include visual and electric warning indicators that assure proper element service. BGT Filters feature Parker s exclusive Magnetic Prefiltration core which collects ferromagnetic particles from fluid upstream of the filter element. This feature alone could save hundreds of dollars a year by protecting costly equipment from increased wear and malfunction by assuring that the fluid is as pure as possible when it leaves the filter. Even during bypass due to cold start up, ferris contaminant is collected by the magnetic core, a feature of importance on any fluid power system. Take a close look and compare Parker features with any other filter. 1. Fluid flows through the inlet port into an enlarged area which reduces fluid velocity. Inlet flow does not impinge on the element. 3. Fluid passes through the element in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates reinjection of contaminant during element change. Clean fluid then returns to the reservoir through the diffusor which prevents fluid aeration. Normal return line filters, that flow outside-to-inside, allow contaminated fluid to drain back into the reservoir when the element is serviced. 4. Simplified bypass design and location prevents flushing previously collected contaminant back into the system. Since the element serves as the valve there is no troublesome separate valve to remove when changing elements. Magnetic filtration occurs even during bypass. All potential leakage paths are o-ring sealed to eliminate bypass leakage that occurs in loose fitting valve assemblies. BGT Filters are available with disposable 61

54 BGT Series How To Size Tank Top Filters Element Pressure Drop Factor: Multiply the actual flow rate times the applicable P factor to determine the pressure drop with a fluid viscosity of 14 SSU. Correct for other viscosities by applying the following formula: Flow rate (GPM) x filter factor x (new viscosity in SSU/14 SSU). Flow/Pressure Drop Data Fluid Conditions: Viscosity-14 SSU Sp. Gr Media Code 6 Size Code 1 2 2Q (L) Q (L) Q (L) Q (L) Example: Element Size Code = 6 Element Media Code = 1 Filter Factor =.22 (From chart) Flow = 16 GPM Viscosity = 16 SSU Formula: 16 GPM x.22 x (16 SSU/14 SSU) = 4. PSID Element Data Media Type Absolute Rating Multipass Test Results To ISO 4572 (Time Weighted Averages) Dimensions BGT-13, BGT-15, BGT-17 B 3 B 6 B 1 B 12 B 2 B 25 B 36 Microglass III >5 Microglass III >5 Microglass III >5 Microglass III >5 Drawings are for reference only. Contact factory for current version. Return Line Filter - Series 4 Dimensions inches (mm) BGT Filter Model C 18. (457) 27. (686) 48. (1219) L (425) 25.2 (64) (12) D 9.49/9.47 (241/24.5) E 1.25/9.7 (26/246) 62

55 BGT Series Parts List Parts Breakdown BGT Series Seals Part Number BGT 13, 15 or 17 R-8875 Cover O-ring SOR-9 SOR-85 R9875 SOR-115 Nitrile or Fluorocarbon *Please specify seal material suffix when ordering Fluorocarbon seals: -V Insert O-ring Bypass Seals Tank Gasket Element O-Ring Material* Bypass Assembly 13, 15 or 17 Pressure Blocked PSID PSID PSID Element: See How To Order Page Part Numbers Item Material BGT-13 BGT-15 BGT-17 1 Top Spring Steel Cover Die Cast Aluminum 3 Head Die Cast Aluminum (584226) Diffusor Steel

Moduflow. ILP and RFP Low Pressure Filters. Series

Moduflow. ILP and RFP Low Pressure Filters. Series Moduflow ILP and RFP Low Pressure Filters Series 27 Applications for Moduflow Filters Power Unit Fabrication Off-line Filter Loops Mobile Equipment The Moduflow filter is widely considered the most versatile

More information

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Moduflow Series IL2/RF2/CF2 Low Pressure Filters IL/RF/CF Low Pressure Filters 35 Applications for Moduflow Filters Power Unit Fabrication Off-line Filter Loops Mobile Equipment The Moduflow filter is widely considered the most versatile filter available

More information

12AT/50AT Series Spin-On Filters

12AT/50AT Series Spin-On Filters 12AT/5AT Series Spin-On Filters Applications for Spin-On Filters Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is

More information

KLT and KLS Series Tank Top Return Line Filters

KLT and KLS Series Tank Top Return Line Filters KLT and KLS Series Tank Top Return Line Filters 23 KLT/KLS Series Tank Top Return Line Filters Applications for KLT and KLS Filters Mobile Equipment Construction, Refuse Industrial Power Units Machine

More information

PT Series Tank Top Filters

PT Series Tank Top Filters Tank Top Filters 9 Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions. Build global confidence. Redefine new limits.

More information

15P/30P Series High Pressure Filters

15P/30P Series High Pressure Filters 1P/P Series High Pressure Filters 124 1P/P Series Applications Saw mills Aircraft ground support equipment Asphalt pavers Hydraulic fan drives Power steering circuits Waste trucks Cement trucks Servo control

More information

BGT Series. Low Pressure Filters

BGT Series. Low Pressure Filters Low Pressure Filters 60 Applications - Flows to 640 GPM - 3 Micron Absolute to 120 Micron Absolute - Disposable or Recleanable Elements - Visual and Electrical Indicators - Microglass elements - Magnetic

More information

12CS/50CS Series Coreless Medium Pressure Filters

12CS/50CS Series Coreless Medium Pressure Filters 12CS/5CS Series Coreless Medium Pressure Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

12CS/50CS Series. Coreless Spin-on Filters

12CS/50CS Series. Coreless Spin-on Filters 12CS/5CS Series Coreless Spin-on Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

RF4 Series. Return Line Filters

RF4 Series. Return Line Filters RF Series Return Line Filters 7 RF Series Applications for RF Filters Mobile Equipment Mining Equipment Industrial Power Units Automotive Specified Equipment The RF is a rugged, industry proven filter

More information

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration. Oil Solutions Return In-Tank Filters Filtration Global Filtration Technology www.oilsolutions.com.au Features/Applications for Tank Top Return Flow Filters Flows to 640 GPM 3 Micron Absolute to 120 Micron

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters 89 //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment

More information

TTF/BGTS Series. Return In-Tank Filters. Global Filtration Technology

TTF/BGTS Series. Return In-Tank Filters. Global Filtration Technology Return In-Tank Filters Global Filtration Technology 25 Features/Applications for Tank Top Return Flow Filters Flows to 640 GPM 3 Micron Absolute to 120 Micron Absolute Disposable or Recleanable Elements

More information

50P Series High Pressure Filters

50P Series High Pressure Filters P Series High Pressure Filters 1 P Series Applications for P series filters Automotive specified equipment Hydrostatic transmission circuits Servo and proportional controls Offshore drilling rigs Mining

More information

15/40/80CN Series. Medium Pressure Filters

15/40/80CN Series. Medium Pressure Filters //8CN Series Medium Pressure Filters 7 //8CN Series Applications for CN series Filters Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile

More information

IL8 Series. Medium Pressure Filters

IL8 Series. Medium Pressure Filters Medium Pressure Filters Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing

More information

IL8 Series. Medium Pressure Filters

IL8 Series. Medium Pressure Filters Medium Pressure Filters 6 Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil patch Flushing

More information

MPD Series. Medium Pressure Duplex

MPD Series. Medium Pressure Duplex Medium Pressure Duplex 81 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses

More information

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

World Pressure Filters A New Standard in 7,000 psi Pressure Filters World Pressure Filters A New Standard in 7, psi Pressure Filters 12 Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

MPD Series Medium Pressure Filters

MPD Series Medium Pressure Filters Medium Pressure Filters 113 Applications - Circulating Lube Oil Systems - Power Generation Control Systems - Steel Mill Control Systems - Pulp & Paper Control Systems - Test Stands - Automotive Stamping

More information

MPD Series. Medium Pressure Duplex

MPD Series. Medium Pressure Duplex Medium Pressure Duplex 89 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses

More information

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters World Pressure Filters A New Standard in 7, psi Pressure Filters 12 WPF Series Applications Together we can the environment. Preserve Minimize waste and promote energy efficiency. worldwide Achieve filtration

More information

World Pressure Filters A new standard in 7,000 psi pressure filters

World Pressure Filters A new standard in 7,000 psi pressure filters World Pressure Filters A new standard in 7, psi pressure filters Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-in filtration Lightweight, non-metallic element that can be incinerated The features a Parker, re-usable coreless

More information

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration. 12CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-in filtration Lightweight, non-metallic element that can be incinerated The 12CS Series features a

More information

12AT/50AT Series Spin-On Filters

12AT/50AT Series Spin-On Filters 1 Applications for Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment. When costs are

More information

12S Series High Pressure Filters

12S Series High Pressure Filters High Pressure Filters 168 Applications - Offshore High pressure and aggressive environment - DI Water Water fogging - Food Processing Caustic washdown (poultry, etc.) - Test Stands High pressure Lightweight

More information

12CS/50CS Series. Coreless Medium Pressure Filters

12CS/50CS Series. Coreless Medium Pressure Filters 1CS/CS Series Coreless Medium Pressure Filters 77 1CS/CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

12AT/50AT Series. Spin-On Filters. Global Filtration Technology 1AT/5AT Series Spin-On Filters Global Filtration Technology 1 1AT/5AT Series Applications for Spin-On Filters n Mobile Equipment n Hydrostatic Drives n Industrial Power Units n Reservoir Breathers Often,

More information

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration. Oil Solutions Medium Pressure Filters Filtration Global Filtration Technology www.oilsolutions.com.au Features/Applications for Medium Pressure Inline Filters GA Series Pressures to 750 PSI Flows to 100

More information

Portable Filter Carts Models 5MF and 10MF

Portable Filter Carts Models 5MF and 10MF s Models 5MF and 10MF 161 Applications for Parker Filter Carts Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid that

More information

Guardian Portable Filtration System

Guardian Portable Filtration System Guardian Portable Filtration System 173 Ground Support Hydraulic Service Mining The Guardian portable fi ltration system is a unique pump/motor/ fi lter combination designed for conditioning and transferring

More information

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart Models 5MFP & 10MFP with Modufl ow and Intelli-Cart 174 Applications Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid

More information

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration.

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration. Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The features a Parker, replaceable coreless

More information

MEDIUM PRESSURE FILTERS

MEDIUM PRESSURE FILTERS Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal

More information

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters

More information

PT Series. Tank Top Filters

PT Series. Tank Top Filters 9 PT Series Disposable Filter Cartridge The new PT series filter is available in two diameters and three lengths for flow ranges from 5-50 gpm. The PT2 and PT4 filter cartridges utilize Microglass III

More information

Medium Pressure Filters

Medium Pressure Filters Medium Pressure Filters Medium pressure filters can be used in applications up to psi (379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters Donaldson Duramax

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

Duplex Pressure Filters

Duplex Pressure Filters Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical

More information

Oil Conditioning Unit

Oil Conditioning Unit 66 Applications The Parker Oil Conditioning Units (OCU) are a family of off-line filtration packages designed to effectively remove water or particulate contamination from hydraulic and lube system fluids.

More information

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 36 psi up to 4 gpm Hydraulic Symbol A D2 Features RF 3 filters are constructed of polyamide plastic. RF 6-33 filters are constructed of aluminum

More information

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters P/3P Series MAX 2 I/min - 27 bar 9 High pressure filters P/3P Series Features & Benefits Features Compact aluminium housing Two head sizes and two bowl lengths Large ports and wide flow paths Microglass

More information

SMR Series. Submicronic Removal Fluid Purifi cation Systems

SMR Series. Submicronic Removal Fluid Purifi cation Systems SMR Series Submicronic Removal Fluid Purifi cation Systems 201 SMR Series Applications The SMR Series is the smart purifi cation solution for fl uid fl ow in the 2-10 GPM (8-38 LPM) range. The SMR contains

More information

Portable Filter Carts 10MFP with Moduflow

Portable Filter Carts 10MFP with Moduflow Portable Filter Carts 10MFP with Moduflow Applications for Portable Filter Carts Parker portable filter carts are the ideal way to prefilter and transfer fluids into reservoirs or to clean up existing

More information

Portable Hydraulic Filtration Systems. Guardian. MAX 15 I/min - 2 bar. Portable filtration systems

Portable Hydraulic Filtration Systems. Guardian. MAX 15 I/min - 2 bar. Portable filtration systems Portable Hydraulic Filtration Systems Guardian MAX 5 I/min - 2 bar 37 Portable filtration systems Portable Hydraulic Filtration Systems Guardian Features & Benefits Features Portable and robust design

More information

Low Pressure Filters

Low Pressure Filters MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight

More information

HYDRAULIC. Coreless Medium Pressure Filters 12CS/50CS Series. Typical Applications. Features:

HYDRAULIC. Coreless Medium Pressure Filters 12CS/50CS Series. Typical Applications. Features: Coreless Medium Pressure Filters 12CS/50CS Series Typical Applications Mobile Ag Mobile Construction Material Handlers Aerial Lifts Pilot Lines Charge Pump Hydrostatic Drives Industrial Power Units Machine

More information

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology Medium Pressure Filters Global Filtration Technology 63 Features/Applications for Medium Pressure Inline Filters AGS Series Rated Working Pressure 1000 PSI Rated Static Pressure 1500 PSI Flows to 25 GPM

More information

Medium Pressure Filters

Medium Pressure Filters Medium Pressure Filters Medium pressure filters can be used in applications up to 2 psi (1379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters MEDIUM PRESSURE

More information

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 4 gpm Technical Specifications Mounting Method 75/9/15/165/185 mounting holes - filter housing D5 Features The compact and lightweight

More information

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf LF(M) High Viscosity Filter Assemblies Low pressure filter assemblies optimized for high flow hydraulic, high viscosity lube and heavily contaminated fuel applications. Max Operating Pressure: 150 psi

More information

Series RFLD Duplex In-Line Filter

Series RFLD Duplex In-Line Filter APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar 1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl

More information

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents

More information

HMK05/25 DURAMAX Spin-Ons

HMK05/25 DURAMAX Spin-Ons 100 gpm, 378 lpm /5 DURAMAX Spin-Ons Working Pressures to: Rated Static Burst to: 350 psi 413 kpa 4.1 bar 800 psi 550 kpa 55. bar Flow Range to: 50 gpm 100 gpm 189 lpm 378 lpm Features (single) and (double)

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters A Filtration Primer Filter Elements High Pressure Filters Tank-Mounted, Return Line and Medium Pressure Filters Water Service Filters Section 6 Reservoir Accessories SCHROEDER INDUSTRIES 259 Principles

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction.... 1- HF65 Series.... 1-9 HF66 Series.... 1-15 HF67 Series.... 1-21 HF68 Series.... 1-1 Dual Spin-On Assembly.... 1-5 Introduction Hydraulic Filtration Systems Cummins

More information

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar / Series Max 26 l/min - 21 bar A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction................................... 1-3 HF65 Series................................. 1-9 HF66 Series................................ 1-15 HF67 Series................................

More information

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm. HY-PRO FILTRATION LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to 16875 lpm, 4500 gpm Features, Benefits, Advantages Carbon steel construction standard (304

More information

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with an aluminum head. Choice

More information

Valves. E Valves. Multiple Hydraulic System Applications

Valves. E Valves. Multiple Hydraulic System Applications s Multiple Hydraulic System Applications Parker Check s are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage caused by fluid back pressure. Offered

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm) FSL HY-PRO FILTRATION Materials of Construction Assembly Frame: Painted Steel Drip Pan: Painted Steel Filter Assembly: Epoxy coated steel 25 or 50 psid bypass available True differential pressure indicator

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the

More information

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with

More information

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids H S S S I N G L E C A R T R I D G E H O U S I N G S Rosedale Model HSS0 and HSS750 Single Cartridge Housings for Liquids Precision Machined Knife-Edge Seal The Rosedale Model HSS single element filter

More information

Taking Hydraulic System Reliability To A Higher Level

Taking Hydraulic System Reliability To A Higher Level Taking Hydraulic System Reliability To A Higher Level Hydraulic Filtration Product Line PureForce Product Line Provides Superior Protection With increased demands on today s hydraulic systems, maintaining

More information

ETF Series. Tanktop Mounted Return Line Filters max. 175 I/min - 6 bar. An economic return line filter. Product Features: Contact Information:

ETF Series. Tanktop Mounted Return Line Filters max. 175 I/min - 6 bar. An economic return line filter. Product Features: Contact Information: max. 75 I/min - 6 bar An economic return line filter Improved system protection The ETF Series utilizes a re-inforced co-polymer head equipped with 2 return ports and quick-release cover. Maximum pressure

More information

[You may download this article at: https://fluidsys.org/downloads/ ]

[You may download this article at: https://fluidsys.org/downloads/ ] Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Disc Valve Hydraulic Motors 4000 Compact Series

Disc Valve Hydraulic Motors 4000 Compact Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Port B Port A Features Shuttle Valve with Back- Pressure Relief Valve Highlights

More information

HPK04 Max Flow: 120 gpm (454 lpm)

HPK04 Max Flow: 120 gpm (454 lpm) HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 6000 psi 41,380 kpa 413.8 bar Rated Static Burst to: Flow Range To: 17000 psi 117,300 kpa 1173 bar 120 gpm 454 lpm Features The high

More information

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar 2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker,

More information

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm Hydraulic Symbol or DFFX FILTER REVERSE FLOW CIRCUIT P Indicator Reverse Flow Valve BY-PASS

More information

Guardian zf04 Portable Filtration Systems

Guardian zf04 Portable Filtration Systems zf04 Portable Filtration Systems Max 15 l/min - 2 bar Global Filtration Technology TYPICAL APPLICATIONS Injection Moulding M/c s Royal Navy Surface Fleet Systems Paper Mills Steel Mills Industrial & Mobile

More information

HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS

HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS Microfil III media are made from micro-fine glass fibers which are randomly laid into a multilayered web. The media are impregnated

More information

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS PRESSURE FILERS FOR MODULAR SACKING Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICAION DF...Z Pressure filters are designed for modular stacking and can be mounted directly to the component to

More information

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm) HY-PRO FILTRATION Materials of Construction Assembly Frame: Painted Steel Drip Pan: Painted Steel Filter Assembly: Epoxy coated steel 25 or 50 psid bypass available True differential pressure indicator

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Hayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems

Hayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems HAYWARD FILTERS Hayward FLT Series Cartridge Filters Designed for the most demanding applications these all plastic cartridge filters are used to filter fine particles from the process fluid. Models are

More information

TTF Series MAX 500 I/min - 10 bar

TTF Series MAX 500 I/min - 10 bar MX 5 I/min - bar N INNOVTIVE GREEN FILTER FETURING LEIF LEIF Low pressure filters Features & enefits Features bar rated filter Cast aluminium head LEIF elements Magnetic pre-filtration In-to-Out filtration

More information

AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:

AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features: Max 5 I/min - bar Featuring prefiltration by means of a magnetic column Extended element life time AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF The TTF Series features pre-filtration by means of a magnet

More information

Low & High Pressure ProGuard Filters

Low & High Pressure ProGuard Filters 56 ±.2 (2.2 ±.5) ø13 +1.5 (5.12 +.6 ) INDICATOR PLUG 193 (7.6) 14 (5.51) 95 (3.74) LABEL 1 5/8-12UNF IN. OR G 1 1/4 PORT SAE-2 PORT 2 PL'S 196 (7.72) 58 (2.28) ø13.2 (5.13) L (4 Low & High Pressure ProGuard

More information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information 142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

FCL Filter Cart Flow rate up to 22 gpm (82 lpm) click here to return to website FCL Filter Cart Flow rate up to 22 gpm (82 lpm) Ideal for high viscosity Lubrication and hydraulic oils (ISOVG22 ~ ISOVG320) Filter new fluids during transfer and replenishment

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold

More information

FPK02 In-Line Cartridge Filters

FPK02 In-Line Cartridge Filters HIGH PRESSURE FILTERS FPK2 Max Flow: gpm (9 lpm) FPK2 In-Line Cartridge Filters Working Pressures to: Rated Static Burst to: Flow Range to: 69 psi 42, kpa 42 bar 913 psi 63, kpa 63 bar gpm 9 lpm Features

More information

7000 Series High Pressure Filters

7000 Series High Pressure Filters 7 Series High Pressure Filters Max 45 l/min - 42 bar FEATURING Global Filtration Technology 7 Series TYPICAL APPLICATIONS Forestry Equipment Industrial Power Units Pulp and Paper Port Handling Equipment

More information

Disc Valve Hydraulic Motors 2000 Series

Disc Valve Hydraulic Motors 2000 Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm Hydraulic Symbol DFF FILTER REVERSE FLOW CIRCUIT Bypass Valve Filter Element Pop-up Indicator Features Available in T ported

More information