PRP kwe 328 kwe 326. LTP kwe 360 kwe 358. cos φ 0,8 0,8

Size: px
Start display at page:

Download "PRP kwe 328 kwe 326. LTP kwe 360 kwe 358. cos φ 0,8 0,8"

Transcription

1 1 TENAX SERIES DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL MODEL MODÈLE MODELO PK 42 T* MODELLO POWERED BY SKID SUPER SILENT GENERATING SET PERFORMANCE PERFORMANCES DU GROUPE PRESTACIONES DEL GRUPO PRESTAZIONI DEL GRUPPO Voltage Voltage Voltaje Tensione Continuous Power Puissance service continue Potencia servicio continuo Potenza servizio continuo Stand-by Power Puissance service secours Potencia servicio emergencia Potenza servizio in emergenza Continuous Power Puissance service continue Potencia servicio continuo Potenza servizio continuo Stand-by Power Puissance service secours Potencia servicio emergencia Potenza servizio in emergenza Power factor Facteur de puissance Factor de potencia Fattore di potenza Fuel consumption Consommation combustible Consumo de combustible Consumo combustibile Hz 6 Hz V 4 / 23 V 22 / 127 PRP kva 4 kva 4 LTP kva 4 kva 44 PRP kwe 328 kwe 326 LTP kwe 36 kwe 38 cos φ,8,8 7 % l/h 61,2 l/h 61, TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

2 2 ENGINE MOTEUR MOTOR MOTORE PERFORMANCE PERFORMANCES PRESTACIONES PRESTAZIONI Continuous Power Puissance service continue Potencia servicio continuo Potenza servizio continuo Stand-by Power Puissance service secours Potencia servicio emergencia Potenza servizio in emergenza Specific fuel consumption Consommation spécifique combustible Consumo especifico de combustibile Consumo specifico combustibile Diesel 4 Stroke Injection type Diesel 4 temps Type injection Diesel 4 tiempos Tipo de inyeccion Diesel a 4 tempi Tipo di iniezione Aspiration type Type d aspiration Tipo de aspiracion Tipo d aspirazione Cooling system Refroidissement Sistema de refrigeracion Raffreddamento Speed governor Régulateur de tours Regulador Regolatore di giri Cylinders, numbers and arrangement Nombre et disposition des cylindres Cilindros, numero y disposicion Numero e disposizione dei cilindri Total displacement Cylindrée totale Cilindrata total Cilindrata totale Bore x stroke Alésage x course Diametro x carrera Alesaggio x corsa Compression ratio Rapport de compression Relación de compresión Rapporto di compressione Engine electric system voltage Voltage système électrique moteur Voltaje sistema eléctrico motor Voltaggio sistema elettrico motore Derating for temperature Déclassement pour temperature Declasamiento para temperatura Declassamento per temperatura Derating for altitude Déclassement pour altitude Declasamiento para altitud Declassamento per altitudine Derating for relative humidity Déclassement pour humidité relative Declasamiento para humedad relativa PERKINS 226C E13 TAG3 1 rpm 18 rpm PRP kwm 349 kwm 349 LTP kwm 392 kwm 381 g/kwh % 218 % 22 7 % 2 7 % 29 g/kwh % 26 % 24 1 % 2 1 % 23 Direct Directe Directa Diretta Turbocharged Suraalimentée Sobrealimentato Sovralimentata Water Eau Agua Acqua Electronic Electronique Electronico Elettronico 6L cm mm 13 x :1 24 V 27 C > 27 C 1 % / C m > m 1, % / m 3 C & % RH Declassamento per umidità relativa 3 C&>RH %,4 %/ % RH TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

3 3 ALTERNATOR ALTERNATEUR ALTERNADOR ALTERNATORE PERFORMANCE PERFORMANCES PRESTACIONES PRESTAZIONI Model Modèle Modelo Modello Continuous Power Puissance service continue Potencia servicio continuo Potenza servizio continuo Stand-by Power Puissance service secours Potencia servicio emergencia Potenza servizio in emergenza Stand-by Power Puissance service secours Potencia servicio emergencia Potenza servizio in emergenza Efficiency Rendement Eficienza 4 C 4 C 27 C LEROY SOMER 1 rpm 18 rpm LSA 47.2 S4 LSA 47.2 VS2 kva 4 KVA 46 kwe 328 kwe 36 KVA 43 KVA kwe 344 kwe 4 KVA 4 KVA 18 kwe 36 kwe 414 1/4 92,4 % 1/4 9,4 % 2/4,4 % 2/4,3 % Efficienza 3/4, % 3/4,7 % 4/4,1 % 4/4,4 % Standard winding connections Liaison des bobinages Tipo de conexiòn Collegamento avvolgimenti Exciter Eccitatrice Excitador Eccitatrice Poles Poles Polos Poli Phases Phases Fases Fasi Wires Fils Hilos Morsetti brushless rotating exciter design with solid state pivotante sans brosses avec pont de diodes pivotants puente de diodos sin escobillas rotantes rotante senza spazzole con ponte di diodi rotanti Voltage regulation Regulation Voltage Regulación voltaje Regolazione tensione Waveform distortion Taux d harmonique Distorciòn forma de onda Distorsione forma d onda Insulation class Classe d isolation Classe de aislamiento Classe di isolamento Enclosure Degré de protection mécanique Grado de protecciòn mecanica Grado di protezione meccanica Maximun overspeed Survitesse Régimen màximo Velocità di fuga AVR model with 3% shortcircuit current Modèle AVR avec un courant de court-circuit du 3% Modelo AVR con una corriente de corto circuito del 3% Modello AVR con corrente di corto circuito del 3% Derating for temperature Déclassement pour temperature Declasamiento para temperatura Y YY N 12 ±, % IEC < 2% (3 In) : s H IP min R 448 AREP 4 C Declassamento per temperatura > 4 C 3 % / C Derating for altitude 1 m Déclassement pour altitude Declasamiento para altitud 1 2 m 3% / m Declassamento per altitudine 2 3 m 4% / m TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

4 4 LOGISTIC INFORMATION INFORMATIONS LOGISTIQUES INFORMATION LOGISTICA INFORMAZIONI LOGISTICHE Integrated fuel tank capacity Capacité reservoir intergré Capacidad Tanque integrado Capacità Serbatoio integrato Weight Poids Peso Peso Dimensions Cotes d encombrement Medidas externas Dimensioni d ingombro ( L. ) (cm) STD EXTRA 1 EXTRA 2 (kg) L W H OPEN SKID VERSION VERSION SUR SKID VERSION ABIERTA 47 ON REQUEST VERSIONE APERTA SOUND PROOF VERSION VERSION INSONORISEE VERSION INSONORISADA VERSIONE INSONORIZZATA ON REQUEST GENSET STANDARD EQUIPMENT EQUIPEMENT STANDARD GROUPE ELECTROGENE EQUIPAMIENTO STANDARD GRUPO ELECTROGENO EQUIPAGGIAMENTO STANDARD GRUPPO ELETTROGENO GB F E I Heavy duty steel base frame Vibration dampers Integrated fuel tank Silencer industrial type Battery Control panel model ACP 73 AUS Push button start Emergency stop button Sound proof canopy of galvanized steel with residential silencer for Super Silent version MANUAL CONTROL PANEL COFFRET ELECTRIQUE MANUEL CUADRO ELECTRICO MANUAL QUADRO ELETTRICO MANUALE ACP 73 AUS STANDARD EQUIPMENT: 4 poles circuit breaker Electronic control board DSE 73 Control panel box key Emergency Stop button Châssis acier Amortisseurs de vibrations Réservoir intégré Silencieux industriel Batterie Coffret de contrôle ACP 73 AUS Bouton de démarrage Bouton arrêt d émergence Capote d insonorisation d acier galvanisé avec silencieux résidentiel pour la version Super Silent Telar de acero Apagadores de vibracion Tanque combustible Silenciador industrial Bateria Cuadro electrico ACP 73 AUS Botón de arranque Botón parada de emergencia Cabina de insonorización de acero cincado con silenciador residencial por la versión Super Silent 63A (4 V - 3 ph - Hz 1 rpm) 12A (22 V - 3 ph - 6Hz 18 rpm) EQUIPEMENT STANDARD: Disjoncteur de protection 4 pôles Fiche électronique DSE 73 Clé pour serrure du coffret Interrupteur d arrêt d émergence EQUIPAMIENTO STANDARD: Interruptor magnetotermico 4 polos Carta electronica DSE 73 Llave cuadro Botón de parada de emergencia Basamento in acciaio Antivibranti Serbatoio integrato Silenziatore industriale Batteria avviamento Quadro elettrico ACP 73 AUS Avviamento con pulsante a pressione Cabina di insonorizzazione di acciaio zincato con marmitta residenziale per la versione Super Silent EQUIPAGGIAMENTO STANDARD: Interruttore magnetotermico 4 poli Scheda elettronica DSE 73 Chiave quadro Pulsante di arresto di emergenza DSE CONTROL BOARD CARTE ELECTRONIQUE DE CONTROL 73 CARTA ELECTRONICA DE CONTROL SCHEDA ELETTRONICA DI CONTROLLO PROTECTIONS PROTECTIONS PROTECCIONES PROTEZIONI Low oil pressure High engine temperature Low fuel level Fail to start Fail to stop Emergency stop Over/under generator frequency Over/under generator voltage Over/under speed Fuel level Belt breakage Over current Over/under battery voltage Basse pression huile moteur Haute température moteur Basse niveau combustible Non démarrage Non arrêt Arrêt d urgence Sur/sous générateu fréquence Sur/sous générateu voltage Sur/sourvitesse Niveau de combustible Rupture courroie Surcourant Sur/sus la tension de batterie Baja presión aceite Elevada temperatura motor Baja nivel carburante Falta de arranque Falta de parada Parada de emergencia Sobre/bajo generatore frecuencia Sobre/bajo generatore voltaje Sobre/bajo velocitad nivel de combustibile Ruptura correa Corriente maxima Sobre/bajo voltaje de la batería Bassa pressione olio Alta temperatura motore Basso livello di carburante Mancato avviamento Mancato arresto Stop d emergenza Sovra/sotto frequenza generatore Sovra/sotto voltaggio generatore Sovra/sotto velocità Livello del carburante Rottura cinghia Sovracorrente Sovra/sotto tensione della batteria DIGITAL METERS VOYANT NUMERIQUE POUR VISOR DIGITAL PARA MISURATORE DIGITALE PER Generator volts ( 3 phases ) Generator amperes ( 3 phases ) Generator frequency KW-meter kva-meter Cos ϕ- meter Rpm meter Gen set hours counter Battery Volts Voltmètre générateur ( 3 phases ) Ampèremètre générateur (3 phases) Fréquencemètre générateur KW-mètre kva- mètre Cos ϕ- mètre Tm mètre Totalisateur d heures de marche Voltmètre batterie Voltimetro ( 3 fases ) Amperimetro ( 3 fases ) Frecuencimetro KW- metro kva- metro Cos ϕ-metro Revolutiones por minuto metro Medida horas de marcha Voltimetro batería Voltmetro tensione generatore (3 fasi) Amperometro generatore ( 3 fasi ) Frequenzimetro generatore KW- metro kva- metro Cos ϕ-metro Gm metro Contaore di funzionamento gruppo Voltmetro batteria TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

5 S AUTOMATIC CONTROL PANEL COFFRET ELECTRIQUE AUTOMATIQUE CUADRO ELECTRICO AUTOMATICO QUADRO ELETTRICO AUTOMATICO 1) 2) 3) ACP 732 ATS ACP 732 AMF ACP COMPLETE CONTROL PANEL FREE STANDING TYPE Equipment: control board, circuit breaker, battery charger, transfer switch, box key. COFFRET ELECTRIQUE COMPLET TYPE ARMOIRE SEPARE DU GROUPE Equipement : carte électronique de contrôle, disjoncteur de protection, chargeur de batterie, inverseur de source, clé coffret. CUADRO ELECTRICO COMPLETO EN ARMARIO SEPARADO DEL GRUPO Equipamiento: carta electronica de controllo, interruptor magnetotermico, cargador de bateria, transferencial, llave quadro. QUADRO ELETTRICO COMPLETO SEPARATO DAL GRUPPO Equipaggiamento: scheda elettronica di controllo, interruttore magnetotermico, carica batteria, telecommutazione e chiave quadro. AMF CONTROL PANEL FITTED ON THE GEN-SET WITHOUT TRANSFER SWITCH Equipment: control board, circuit breaker, battery charger, box key. COFFRET ELECTRIQUE MONTE SUR LE GROUPE SANS INVERSEUR DE SOURCE Equipement : carte électronique de contrôle, disjoncteur de protection, chargeur de batterie, clé coffret. CUADRO ELECTRICO MONTADO SOBRE EL GRUPO SIN TRANSFERENCIAL Equipamiento: carta electronica de controllo, interruptor magnetotermico, cargador de bateria, llave quadro. QUADRO ELETTRICO MONTATO SUL GRUPPO ELETTROGENO SENZA TELECOMMUTAZIONE Equipaggiamento: scheda elettronica di controllo, interruttore magnetotermico, carica batteria, chiave quadro. CONTROL PANEL FITTED ON THE GEN-SET WITH TRANSFER SWITCH SUPPLIED IN A SEPARATED BOX Equipment: control board, circuit breaker, battery charger, box key, separate transfer switch. 732 COFFRET ELECTRIQUE MONTE SUR LE GROUPE + INVERSEUR DE SOURCE FOURNI DANS UN COFFRET SEPARE Equipement : carte électronique de contrôle, disjoncteur de protection, chargeur de batterie, inverseur de source separé, clé coffret. STS CUADRO ELECTRICO MONTADO SOBRE EL GRUPO CON TRANSFERENCIAL SEPARADO Equipamiento: carta electronica de controllo, interruptor magnetotermico, cargador de bateria, llave quadro, transferencial separado. QUADRO ELETTRICO MONTATO SUL GRUPPO ELETTROGENO CON TELECOMMUTAZIONE SEPARATA Equipaggiamento: scheda elettronica di controllo, interruttore magnetotermico, carica batteria, chiave quadro, telecommutazione in armadio separato. CONTROL BOARD CARTE ELECTRONIQUE DE CONTROL DSE 732 CARTA ELECTRONICA DE CONTROL SCHEDA ELETTRONICA DI CONTROLLO GB F E I The DSE732 is an Automatic Mains Failure Control Module designed to automatically start and stop diesel generating sets that include electronic and non electronic engines. The module also provides excellent genset monitoring and protection features. La DSE732 est une carte de contrôle projetée pour démarrer et arrêter automatiquement groupes électrogènes diesels avec moteurs électroniques et non électroniques. La carte représente un système excellent de contrôle et de protection du groupe électrogène. La DSE732 es una carta de control para arranquar y parar automáticamente grupos electrógenos diesel con motores electrónicos y no electrónicos. La carta constituye un excelente sistema de control y protección del grupo electrógeno. La DSE732 è una scheda di controllo progettata per avviare e arrestare automaticamente gruppi elettrogeni diesel con motori elettronici e non elettronici. La scheda costituisce un eccellente sistema di controllo e di protezione del gruppo elettrogeno. FEATURES EQUIPEMENT EQUIPMENT EQUIPAGGIAMENTO Stop/reste Auto Manual Start LCD display scroll Event log view Acustic alarm Fiche électronique de contrôle DSE732 Disjoncteur de protection Chargeur de batterie Bouton poussoir arrête d émergence Ficha electrónica de control DSE732 Interruptor magnetorermico Cargador de batería Boton de parada de emergencia Scheda elettronica di controllo DSE732 Interruttore magnetotermico Carica batteria Pulsante stop emergenza DIGITAL MEASURING MESURES NUMERIQUES MEDIDAS DIGITALES MISURAZIONI DIGITALI Generator volts (3 phases) Generator amperes (3 phases) Generator frequency KW-meter kva-meter Cos ϕ- meter Rpm meter Water temperature (optional) Oil pressure (optional) Gen set hours counter Mains volts Battery volts Mains frequency Charging voltage Start-counter Fuel level % Voltmètre générateur (3 phases) Ampèremètre générateur (3 phases) Fréquencemètre générateur KW-mètre kva- mètre Cos ϕ- mètre Tm mètre Température eau (facultatif) Pression huile (facultatif) Totalisateur d heures de marche Voltmètre secteur Voltmètre batterie Fréquence réseau Tension de charge Compteur démarrages Niveau combustible % Voltimetro (3 fases) Amperimetro (3 fases) Frecuencimetro KW- metro kva- metro Cos ϕ-metro Revolutiones por minuto metro Termometro agua (opcional) Presión aceite (opcional) Medida horas de marcha Voltimetro tensión de red Voltimetro batería Frequencia red Tensión de carga Numero de arranques Nivel carburante % Voltmetro tensione generatore (3 fasi) Amperometro generatore (3 fasi ) Frequenzimetro generatore KW- metro kva- metro Cos ϕ-metro Gm metro Temperatura acqua (facoltativo) Pressione olio (facoltativo) Contaore di funzionamento gruppo Voltmetro tensione rete Voltmetro batteria Frequenza rete Tensione di carica Contavviamenti Livello carburante % INDICATORS INDICATEURS INDICADORES INDICATORI Mains live Generator live Mains contactor closed Generator contactor closed Engine running Présence secteur Présence tension générateur Inverseur secteur fermé Inverseur générateur fermé Moteur en marche Presencia tensión de red Presencia tensión grupo Transferencial red cerrado Transferencial grupo cerrado Motor en marcha Presenza tensione di rete Presenza tensione generatore Erogazione da rete Erogazione da gruppo Motore avviato PROTECTIONS PROTECTIONS PROTECCIONES PROTEZIONI Low oil pressure High engine temperature Low fuel level Fail to start Fail to stop Emergency stop Over/under frequency Over/under voltage Over/under speed Fuel level Belt breakage Over current Over/under battery voltage Bas pression huile moteur Haute température moteur Bas niveau combustible Non démarrage Non arrêt Arrêt d urgence Sur/sous fréquence Sur/sous voltage Sur/sous vitesse Niveau de combustible Rupture courroie Surcourant Sur/sus la tension de batterie Baja presión aceite Elevada temperatura motor Baja nivel carburante Falta de arranque Falta de parada Parada de emergencia Sobre/bajo frecuencia Sobre/bajo voltaje Sobre/bajo velocitad nivel de combustibile Ruptura correa Corriente maxima Sobre/bajo voltaje de la batería Bassa pressione olio Alta temperatura motore Basso livello di carburante Mancato avviamento Mancato arresto Stop d emergenza Sovra/sotto frequenza Sovra/sotto voltaggio Sovra/sotto velocità Livello del carburante Rottura cinghia Sovracorrente Sovra/sotto tensione della batteria TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

6 6 SOUNDPROOF CANOPY CAPOTE D INSONORISATION CAPOTA DE INSONORIZACION CABINA INSONORIZZATA GB F E I The TecnoGen Super Silent soundproof canopy has been designed with the aim of achieving the maximum noise level reduction and to provide a perfect cooling of the engine. The cooling airflow is forced through fixed circuits. The canopy is suitable for tropical ambient application. The exhaust gas silencer is residential type internally mounted. The canopy is completely built of hot galvanized carbon sheet steel. The sheets have a thickness 2/. The structure is fully bolted, fixed by a special polyethylene sealing, completely free from electrical installation. All the panels can be easily removed. The cab is provided with doors of wide opening for easy access to generating set for the maintenance operations. The soundproofing materials are highly fire resistant and self-extinguishing. Our quality in points Notre qualité résumée en points Nuestra calidad en puntos La nostra qualità in punti 1 La capote insonorisée TecnoGen Super Silent à été conçue pour atteindre le niveau de bruit le mineur possible et un refroidissement du moteur parfait. Le souffle d air refroidissant est canalisé en circuits fixes. La capote est apte à être utilisée dans les ambiances tropicales. Le silencieux des gaz d échappement, de type résidentiel, est mis à l intérieur de la capote. La cabine est construite en acier galvanisé à chaud. Les tôles ont une épaisseur de 2/. La structure est complètement boulonnée et fixée à travers des garnitures spéciales au polyéthylène. Tous les panneaux sont facilement amovibles. La cabine est dotée de portes avec grandes ouvertures qui permettent un accès facile au groupe électrogène pour les opérations de manutention. Les matériaux d insonorisation sont fortement résistant au feu et autoextinguibles. Internal residential silencer for lower sound levels Silencieux interne pour un niveau bas de bruit Silenciador interno para un nivel de rumorosidad más bajo Silenziatore interno per un livello di rumorosità piú basso La capota insonorizada TecnoGen Super Silent tiene sido planeada con el objetivo de alcanzar el menor nivel de rumorosidad posible y un perfecto enfriamiento del motor. El soplo de aire es canalizado en circuitos fijos. La cabina es apta a ser utilizada en ambientes tropicales. El silenciador de los gases de descargue, de tipo residencial, es colocado dentro de la cabina. La cabina es construida en acero cincado. Las chapas tienen un espesor de 2/. La estructura es completamente bullonata y montada con sellos especiales de polietilene. Todos los paneles son fácilmente removibles. La cabina es dotada con puertas con amplias aberturas que permiten el fácil acceso al grupo electrógeno por las operaciones de manutención. Los materiales insonorizantes son muy resistentes al fuego y autoexinguentes. La cabina insonorizzata TecnoGen Super Silent è stata progettata allo scopo di raggiungere il minor livello di rumorosità possibile e un perfetto raffreddamento del motore. Il soffio d aria raffreddante è canalizzato in circuiti fissi. La cabina è adatta ad essere utilizzata in ambienti tropicali. Il silenziatore dei gas di scarico, di tipo residenziale, è collocato all interno della cabina. La cabina è costruita in acciaio zincato a caldo. Le lamiere hanno uno spessore di 2/. La struttura è completamente bullonata e fissata tramite speciali sigilli al polietilene. Tutti i pannelli sono facilmente rimovibili. La cabina è dotata di porte con ampie aperture che consentono il facile accesso al gruppo elettrogeno per le operazioni di manutenzione. I materiali insonorizzanti sono altamente resistenti al fuoco e autoestinguenti Integrated fuel tank of different sizes Réservoirs de combustible disponibles, sur demande, de capacité supérieure Tanques integrados disponibles, como opción, de capacidad superior Serbatoi integrati disponibili, su richiesta, di capacità superiore Control panel viewing window to easily check status of generating set Fenêtre de visualisation du panneau de contrôle pour un contrôle plus facile du status opérationnel du groupe Ventana de visualización del panel de control por un más fácil control del estatus operativo del grupo Finestra di visualizzazione del pannello di controllo per un piú facile controllo dello status operativo del gruppo Lockable access doors for extra safety and security Porte d accès avec serrure pour une sûreté majeure Puertas de acceso con cerradura para una mayor seguridad Porte di accesso con serratura per una maggiore sicurezza Galvanized bolts Boulons galvanisés Pernos cincados Bulloni zincati Emergency stop button Interrupteur d arrêt d urgence Botón parada de emergencia Pulsante arresto di emergenza Doors location convenient to controls and service area Placement des portes pour rendre les contrôles plus faciles Colocación de las puertas para facilitar los controles Collocazione delle porte per facilitare i controlli High serviceability level Haut niveau d accessibilité pour la manutention Alto nivel de accesibilidad para la manutención Alto livello di accessibilità per la manutenzione Large cable entry area for easy installation Grande zone d entré des câbles pour une installation plus facile Amplia área de entrada cables para una instalación fácil Ampia area di entrata cavi per una facile installazione Galvanized metal steel sheet pre-treated prior to powder coating Tôles en acier galvanisé pré-traitées avant le vernissage à poudre Chapas de acero cincado pre-tratadas antes de la pintura a polvo Lamiere di acciaio zincato pre-trattate prima della verniciatura a polvere TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

7 7 OPEN SKID VERSION DRAWING DESSIN VERSION SUR SKID DIBUJO VERSION ABIERTA DISEGNO VERSIONE APERTA TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

8 8 SOUND PROOF VERSION DRAWING DESSIN VERSION INSONORIZEE DIBUJO VERSION INSONORISADA DISEGNO VERSIONE INSONORIZZATA TECNOGEN SpA - postal address: strada Ponteriglio, 2 29 Pontenure (PC)- ITALY Tel Fax export@tecnogen.com - Web site:

9 The 22 Series engine has been developed using the latest engineering techniques and builds on the strengths of the already very successful 2 Series family and addresses today s uncompromising demands within the power generation industry. Developed from a proven heavy-duty industrial base, these products offer superior performance and reliability. The 226C-E13TAG range are 6 cylinder, turbocharged air-to-air charge cooled diesel engines. It s premium features provide exceptional power to weight ratio resulting in exceptional fuel consumption. The overall performance and reliability characteristics make this the prime choice for today s power generation industry. 22 Series 226C-E13TAG3 Diesel Engine - ElectropaK 392 kwm at 1 rpm 381 kwm at 18 rpm Economic Power Mechanically operated unit fuel injectors with electronic control combined with carefully matched turbocharging, give excellent fuel atomisation and combustion with optimum economy. Low emissions result from electronically controlled fuel injection. Reliable Power Developed and tested using the latest engineering techniques and finite element analysis for high reliability, low oil usage and low wear rates. High compression ratios ensure clean rapid starting in all conditions. Perkins global product support is designed to enhance the customer experience of owning a Perkins powered machine. We deliver this through the quality of our distribution network, extensive global coverage and a range of Perkins supported OEM partnership options. So whether you are an end-user or an equipment manufacturer our engine expertise is essential to your success. Compact, Clean and Efficient Power Exceptional power to weight ratio and compact size give optimum power density for ease of installation and more cost effective transportation. Designed to provide excellent service access for ease of maintenance. Product Support Perkins actively pursues product support excellence by ensuring our distribution network invest in their territory - strengthening relationships and providing more value to you, our customer Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 36 days a year. They have a comprehensive suite of web based tools at their fingertips covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts and service. We give % reassurance that you receive the very best in terms of quality for lowest possible cost.. wherever your Perkins powered machine is operating in the world Certified against the requirements of EU27 Stage II (EU97/68/EC Stage II) legislation for non-road mobile machinery, powered by constant speed engines and is capable of meeting 1/2 TA Luft (1986) emissions legislation. Engine Speed (rev/min) Type of Operation Typical Generator Output (Net) The above ratings represent the engine performance capabilities to conditions specified in ISO 828/1, ISO 346/1:1986, BS 14/1, DIN 6271 Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. θ) of.8. Fuel specification: BS 2869: Part Class A2 or BSEN9 or ASTM D97 Class 1D and 2D. Lubricating oil: 1W4 to API CI4. Rating Definitions Prime Power: Variable load. Unlimited hours usage with an average load factor of 7% of the published prime power rating over each 24 hour period. A % overload is available for 1 hour in every 12 hours of operation. Standby Power: Variable load. Limited to hours annual usage up to 3 hours of which may be continuous running. No overload is permitted. Gross Engine Power kva kwe kwm bhp kwm bhp 1 Prime Power Standby Power Prime Power Standby Power Net All information in this document is substantially correct at time of printing and may be altered subsequently Publication No. 188/2/9 Produced in England 27 Perkins Engines Company Limited

10 22 Series 226C-E13TAG3 Standard ElectropaK Specification Air inlet Mounted air filter 24 mm 112 mm Fuel system Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control Governing to ISO 828- class G2 with isochronous capability Replaceable Ecoplus fuel filter elements with primary filter/water separator Fuel cooler Lubrication system Wet sump with filler and dipstick Full-flow replaceable Ecoplus filter Oil cooler integral with filter header Cooling system Gear-driven circulating pump Mounted belt-driven pusher fan Radiator incorporating air-to-air charge cooler, (supplied loose) System designed for ambients up to ºC Electrical equipment 24 volt starter motor and 24 volt 7 amp alternator with DC output ECM mounted on engine with wiring looms and sensors 3 level engine protection system Flywheel and housing High inertia flywheel to SAE J62 size 14 SAE 1 flywheel housing Mountings Front engine mounting bracket Literature User s Handbook and Parts Manual Optional Equipment 1 volt/24 volt immersion heater Additional speed sensor Temperature and pressure sensors for gauges Air filter rain hood Twin starters/facility for second starter Tool kit 172 mm Fuel Consumption (based on net power) 1 rev/min 18 rev/min Engine Speed g/kwh l/hr g/kwh l/hr Standby power % prime power % prime power % prime power % prime power General Data Number of cylinders 6 Cylinder arrangement Vertical in-line Cycle 4 stroke Induction system Turbocharged and air-to-air charge cooled Combustion system Direct injection Cooling system Water-cooled Bore and stroke 13 x 17 mm Displacement 12. litres Compression ratio 16.3:1 Direction of rotation Anti-clockwise, viewed on flywheel Total lubrication system 4 litres capacity Total coolant capacity 1.4 litres Total dry weight 1478 kg Dimensions Length 24 mm Width 112 mm Height 172 mm Final weight and dimensions will depend on completed specification Perkins Engines Company Limited Peterborough PE1 NA United Kingdom Telephone +44 () Fax +44 () Distributed by All information in this document is substantially correct at time of printing and may be altered subsequently Publication No.188/2/9 Produced in England 27 Perkins Engines Company Limited

11 LSA Pole SPECIALLY ADAPTED FOR APPLICATIONS The LSA 47.2 alternator is designed to be suitable for typical generator applications, such as: stand-by, prime power, cogeneration, marine, rental, telecommunications, etc. COMPLIANT WITH INTERNATIONAL STANDARDS The LSA 47.2 alternator conforms to the main international standards and regulations: IEC 634, NEMA MG 1.22, ISO 828/3, CSA, UL 1446, UL 4B request, marine regulations, etc. It can be integrated into a CE marked generator-set. The LSA 47.2 is designed, manufactured and marketed in an ISO 91 environment and ISO 141. TOP OF THE RANGE ELECTRICAL PERFORMANCE - Class H insulation. - Standard 12-wire re-connectable winding, 2/3 pitch, type no. 6 (the LSA 47.2 L9 is available in two versions: 6-wire and 12-wire). - Voltage range: 22 V - 24 V and 38 V - 41 V (44 V) - Hz / 28 V - 24 V and 38 V - 48 V - 6 Hz. - High efficiency and motor starting capacity. - Other voltages are possible with optional adapted windings: - Hz: 44 V (no. 7), V (no. 9), 6 V (no. 22 or 23), 69 V (no. or 2) - 6 Hz: 38 V and 416 V (no. 8), 6 V (no. 9). - Total harmonic content < 2%. - R 791 interference suppression conforming to standard EN 11 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION Excitation system Regulation options Voltage regulator SHUNT AREP PMG T.I. Current transformer for paralleling R 726 Mains paralleling R phase sensing R phase sensing on mains paralleling unbalanced P Remote voltage potentiometer R 2 Std R 448 optional Std Std DECS - optional optional included included NA Voltage regulator accuracy +/-.% - : possible adaptation - NA : not possible. PROTECTION SYSTEM SUITED TO THE ENVIRONMENT - The LSA is IP Standard winding protection for clean environments with relative humidity ð 9 %, including indoor marine environments. Options: Filters on air inlet and air outlet (IP 44). Winding protections for harsh environments and relative humidity greater than 9%. Space heaters. Thermal protection for windings and shields. REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING - Standard direction of rotation : clockwise when looking at the drive end view (engine side). Running unit anti-clockwise: a derate of % must be applied. - Compact and rigid assembly to better withstand generator-set vibrations. - Steel frame. - Cast iron flanges and shields. - Two bearing and single bearing versions designed to be suitable for engines on the market. - Half-key balancing. - Greased for life bearings (regreasable bearings optional) ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT - Easy access to the voltage regulator and to the connections. - Possible clusion of accessories for paralleling, protection and measurement. - 8-way terminal block for voltage reconnection. - DECS digital AVR with external fitting possible. Copyright 24 : MOTEURS LEROY-SOMER Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization. Their description cannot, in any case, engage LEROY-SOMER liability. The values indicated are typical values. 2

12 LSA Pole Common data Insulation class H Excitation system SHUNT (12 wire) A R E P or PMG Winding pitch 2/3 (N 6 or N 6S) A.V.R. model R 2 R 448 Terminals 12 (N 6) / 6 (N 6S) Voltage regulation (*) ±, % ±, % Drip proof IP 23 Sustained short-circuit current - 3% (3 IN) : s Altitude m Total harmonic TGH / THC (**) at no load < 1, % - on load < 2 % Overspeed 22 min -1 Waveform : NEMA = TIF (**) < Air flow,9 m 3 /s (Hz) / 1,1 (6Hz) Wave form : I.E.C. = THF(**) < 2 % (*) Steady state duty. (**) Total harmonic content line to line, at no load or full rated linear and balanced load. Ratings Hz - 1 R.P.M. 12 wire 6 wire kva / kw - Power factor =,8 Duty Continuous duty 4 C Continuous duty / 4 C Stand-by/ 4 C Stand-by / 27 C Class/T K H / 12 K F / K H / 1 K H / 163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 4V 41V 38V 4V 41V 38V 4V 41V 38V 4V 41V Δ 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V YY 2V 2V 2V 2V 47.2 VS2 kva kw S4 kva kw S kva kw M7 kva 46 7 kw M8 kva 7 6 kw L9 kva kw Y 38V 4V 41V 38V 4V 41V 38V 4V 41V 38V 4V 41V Δ 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V 47.2 L9* kva kw Ratings 6 Hz - 18 R.P.M. 12 wire kva / kw - PF =,8 Duty Continuous duty 4 C Stand-by / 4 C Stand-by / 27 C Class / T K H / 12 K F / K H / 1 K H / 163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V Δ 22V 24V 22V 24V 22V 24V 22V 24V YY 28V 22V 24V 28V 22V 24V 28V 22V 24V 28V 22V 24V 47.2 VS2 kva kw S4 kva kw S kva kw M7 kva kw M8 kva kw L9 kva kw wire Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V Δ 22V 24V 22V 24V 22V 24V 22V 24V 47.2 L9* kva kw * AREP excitation only 3

13 LSA Pole Efficiencies Hz - P.F. : 1 / P.F. :,8 96% LSA 47.2 VS kva 97% LSA 47.2 S P.F. : 1.3 P.F. : P.F. :, kva 97% LSA 47.2 S 9.8 P.F. : P.F. :, P.F. :, kva.8. 97% LSA 47.2 M P.F. : P.F. :, kva 97% 96 9 LSA 47.2 M P.F. : P.F. :, kva LSA 47.2 L9 (12 w.) LSA 47.2 L9 (6 w.) 97% P.F. : ,1 9, P.F. :, kva Reactances (%). Time constants (ms) - Class H / 4 V VS2 S4 S M7 M8 L9 L9 (6f) Kcc Short-circuit ratio,38,37,33,41,32,37,38 Xd Direct axis synchro.reactance unsaturated Xq Quadra. axis synchr.reactance unsaturated T do Open circuit time constant X d Direct axis transient reactance saturated 19,3 17,3 19,2 1,9 18,3 16, 16,2 T d Short-Circuit transient time constant X"d Direct axis subtransient reactance saturated 13, 12,1 13, 11,1 12,9 11,4 11,6 T"d Subtransient time constant X"q Quadra. axis subtransient reactance saturated 18,4 16, , ,2 Xo Zero sequence reactance unsaturated,9,9,9,7,6,9,2 X2 Negative sequence reactance saturated 16 14,2 1, ,2 13,4 Ta Armature time constant Other data - Class H / 4 V io (A) No load excitation current 1,9,9 1,9,9,9 ic (A) Full load excitation current 3,8 3, 3,8 3,6 3,7 3,7 3,7 uc (V) Full load excitation voltage ms Recovery time (ΔU = 2 % trans.) kva Motor start. (ΔU = 2% sust.) or (ΔU = % trans.) SHUNT kva Motor start. (ΔU = 2% sust.) or (ΔU = % trans.) AREP % Transient dip (rated step load) SHUNT / PF :,8 LAG 16,8 1, 16,7 14,6 16,2 1 14,8 % Transient dip (rated step load) AREP / PF :,8 LAG 13,7 12,7 13,6 11,9 13,2 12,2 12,1 W No load losses W Heat rejection

14 LSA Pole Transient voltage variation 4 V - Hz Load application (SHUNT excitation) 2 % 2 VS 2 S 4 S L 9 6/12w Load application (AREP or PMG excitation) 2 % 2 VS 2 S 4 S % Voltage dip 1 % Voltage dip 1 L 9 6/12w kva kva kva at,8 power factor kva at,8 power factor Load rejection (SHUNT excitation) VS 2 S 4 S Load rejection (AREP or PMG excitation) VS 2 S 4 S 3% 3% 2 2 % Voltage rise 2 1 L 9 6/12w % Voltage rise 2 1 L 9 6/12w kva kva kva at,8 power factor kva at,8 power factor Motor starting (SHUNT excitation) 3% VS 2 S 4 S Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S 3 L 9 3 6/12w L /12w % Voltage dip 2 1 % Voltage dip kva kva kva Locked rotor kva Locked rotor 1) For a starting P.F. differing from,6, the starting kva must be multiplied by (Sine Ø /,8) 2) For voltages other than 4V(Y), 23V() at Hz, then kva must be multiplied by (4/U)2 or (23/U)2.

15 LSA Pole Efficiencies 6 Hz - P.F. :1 / P.F. :,8 96% % LSA 47.2 VS P.F. : P.F. :, kva LSA 47.2 S4 9.7 P.F. : P.F. :, kva 97% LSA 47.2 M7 96 P.F. : P.F. :, kva 97% 96 9 LSA 47.2 M8 96 P.F. : P.F. :, kva LSA 47.2 S 96% 9.7 P.F. : P.F. :, kva 97% LSA 47.2 L9 (12 w.) LSA 47.2 L9 (6 w.) P.F. : P.F. :, kva Reactances (%). Time constants (ms) - Class H / 48 V VS2 S4 S M7 M8 L9 L9 (6f) Kcc Short-circuit ratio,36,36,32,4,31,3,36 Xd Direct axis synchro.reactance unsaturated Xq Quadra. axis synchr.reactance unsaturated T do Open circuit time constant X d Direct axis transient reactance saturated 2,1 18 2,1 16, 19,2 17,2 16,9 T d Short circuit transient time constant X"d Direct axis subtransient reactance saturated 14,1 12, ,6 13,4 11,8 12,1 T"d Subtransient time constant X"q Quadra. axis subtransient reactance saturated 19,1 16,9 18,8 1,3 17,8 1,6 1,8 Xo Zero sequence reactance unsaturated,1,4,1,1,9,9,4 X2 Negative sequence reactance saturated 16,6 14,8 16, 13, 1,6 13,7 14 Ta Armature time constant Other data - Class H / 48 V io (A) No load excitation current 1,9,9 1,9,9,9 ic (A) Full load excitation current 3,9 3, 3,9 3,7 3,8 3,7 3,7 uc (V) Full load excitation voltage ms Recovery time (ΔU = 2 % trans.) kva Motor start. (ΔU = 2% sust.) or (ΔU = % trans.) SHUNT kva Motor start. (ΔU = 2% sust.) or (ΔU = % trans.) AREP % Transient dip (rated step load) SHUNT / PF :,8 LAG 17, ,3 1 16,7 1, 1,3 % Transient dip (rated step load) AREP / PF :,8 LAG 14, ,1 12,2 13,6 12,6 12,4 W No load losses W Heat rejection

16 LSA Pole Transient voltage variation - 48 V - 6 Hz Load application (SHUNT excitation) 2 % 2 % Voltage dip 1 VS 2 S 4 S L 9 6/12w. % Voltage dip Load application (AREP or PMG excitation) 2 % 2 1 VS 2 S 4 S L 9 6/12w kva kva kva at,8 power factor kva at,8 power factor Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S 2 2 % Voltage rise 2 1 L 9 6/12w. % Voltage rise 2 1 L 9 6/12w kva kva kva at,8 power factor kva at,8 power factor Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S 3 2 L 9 6/12w. 3 2 L 9 6/12w. % voltage dip 2 1 % voltage dip kva kva Locked rotor Locked rotor 1) For a starting P.F. differing from,6, the starting kva must be multiplied by (Sine Ø /,8) 2) For voltages other than 48V(Y), 277V(), 24V(YY) at 6 Hz, then kva must be multiplied by (48/U) 2 or (277/U) 2 or (24/U) 2. 7

17 LSA Pole 3 phase short-circuit curves at no load and rated speed (star connection Y) LSA 47.2 VS2 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 S4 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 S AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) Influence due to connexion. Curves shown are for star connection (Y). For other connections, use the following multiplication factors : - Series delta : Current value x 1,732 - Parallel star : Current value x 2 8

18 LSA Pole 3 phase short-circuit curves at no load and rated speed (star connection Y) LSA 47.2 M7 AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) LSA 47.2 M8 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 L9 (6w / 12 w) AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) Influence due to short-circuit. Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors : 3 phase 2 phase L - L. 1 phase L - N. Instantaneous (Max) 1,87 1,3 Sustained 1 1, 2,2 Max sustained duration (AREP/ PMG) sec. sec. 2 sec. 9

19 LSA Pole Single bearing dimensions L Y DIA, X Eq.Sp holes on U P.C.D. A.V.R. LB 74 AH Xg 6 49 ß 14, CF PMG option Cable 12 Ø P -,127 Ø N -, -, Ø BX Ø ,3 Ø 23 2 x Ø13 Ø AIR OUTLET AIR INLET Access to rectifiers S DIA, XBG Eq. Sp. holes on M P.C.D. FRAME DIMENSIONS (mm) COUPLING TYPE L max without PMG LB Xg Weight(kg) Flex plate 11 1/ LSA 47.2 VS LSA 47.2 S Flange S.A.E 1 X X LSA 47.2 S Flange S.A.E 1/2 X LSA 47.2 M Flange S.A.E X X LSA 47.2 M LSA 47.2 L Flange dimensions (mm) Flex plate dimensions (mm) S.A.E. P N M XBG S ß CF S.A.E. BX U X Y AH ,17 3, /2 32,4 333, ,6 1/ ,2 619, ,7 438, , ,7 679, , 42, ,7 Torsional analysis data Xr Ø 7 Ø 6 Ø 11 Ø 12 Ø 11 Ø 1 Ø 7 Lr Gravity center : Xr (mm), Rotor length Lr (mm), Weight : M (kg), Moment of inertia : J (kgm 2 ) : (4J = MD 2 ) Flex plate S.A.E. 11 1/2 Flex plate S.A.E. 14 Flex plate S.A.E. 18 TYPE Xr Lr M J Xr Lr M J Xr Lr M J LSA , ,99 418, ,12 48, ,38 LSA 47.2 S , , ,29 LSA 47.2 S , , ,29 LSA 47.2 M , , LSA 47.2 M , , ,4 LSA 47.2 L , , ,91

20 LSA Pole Two bearing dimensions L AVR access 1 hole M2x Xg LB PMG option Cable 12 Ø 713 Ø 2 -,127 Ø 11,17 Ø 8 m6 Ø ,3 Ø 23 2 x Ø AIR OUTLET AIR INLET Diode access M DIA, 12 ep. sp. hole on 3,22 PCD FRAME DIMENSIONS (mm) TYPE L maxi without PMG LB Xg Weight (kg) LSA 47.2 VS LSA 47.2 S LSA 47.2 S LSA 47.2 M LSA 47.2 M LSA 47.2 L Torsional analysis data Xr 13 Ø 8 Ø 9 Ø 6 Lr Ø 11 Ø 12 Ø 11 Ø 1 Ø 7 Gravity center : Xr (mm), Rotor length Lr (mm), Weight : M (kg), Moment of inertia : J (kgm 2 ) : (4J = MD 2 ) TYPE Xr Lr M J LSA 47.2 VS2 396, ,,79 LSA 47.2 S4 433, ,7 LSA 47.2 S 433, ,7 LSA 47.2 M ,2 7,41 LSA 47.2 M8 483, ,9 7,81 LSA 47.2 L9 4, ,32 11

21 DSECONTROL MONITORING WITH INTELLIGENCE. DSE73 & DSE732 AUTO START & AUTO MAINS FAILURE CONTROL MODULES (COMMUNICATIONS & EXPANSION) SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8V to 3V Continuous CRANKING DIP PROTECTION Able to survive V for ms, providing supply was at least V before dropout and supply recovers to V. This is achieved without the need for internal batteries CHARGE FAIL/ EXCITATION V to 3V fixed power source 2.W MAXIMUM STANDBY CURRENT 16mA at 12V 8mA at 24V MAXIMUM OPERATING CURRENT 34mA at 12V 16mA at 24V ALTERNATOR INPUT The DSE73 and DSE732 are new control modules for single gen-set applications. The modules have been developed from the successful DSE3 and DSE32 Series and incorporate a number of advanced features to meet the most demanding on-site applications. The DSE73 is an Automatic Start Control Module and the DSE732 is an Auto Mains (Utility) Failure Control Module. Both modules have been designed to start and stop diesel and gas generating sets that include electronic and non-electronic engines. The DSE732 includes the additional capability of being able to monitor a mains (utility) supply. Both modules include USB, RS232 and RS48 ports as well as dedicated DSENet terminals for expansion device connectivity. The modules are simple to operate and feature a newly designed menu layout for improved clarity. Enhanced features include a real time clock for enhanced event and performance monitoring, ethernet communications for low cost monitoring, mutual standby to reduce engine wear and tear, trend analysis to assist in the detection of patterns in engine status and preventative maintenance designed to detect if engine parts have developed fault conditions so they can be replaced before a major problem occurs. FEATURES Backed up real time clock 132 x 64 pixel LCD display Configurable display languages USB connectivity Robust module enclosure Five-key menu navigation Durable soft touch membrane buttons Fully configurable via PC software LED and LCD alarm indication Engine exercise mode Configurable start & fuel outputs kwh monitoring Automatic load transfer Eight configurable digital inputs Six configurable outputs Configurable timers and alarms Modbus RTU Magnetic pick-up Front panel programming Multiple date and time exercise scheduler SMS messaging Power save mode PIN protected programming User selectable RS232 & RS48 communications DSENet compatible Ethernet communications via DSE86/86 Customer logo display capability Multiple date and time maintenance scheduler Configurable display pages Programmable load shedding/acceptance Trend analysis Preventative maintenance kw overload protection Unbalanced load protection PDA compatible PC software Flexible sender input Configurable SCADA output page NEW FEATURES True dual mutual standby with load balancing timer Fan control for additional cooling Protections Disabled facility Fuel usage monitoring and low fuel alarm Support for up to three remote display units Automatic sleep mode Easy access, configurable diagnostics page shows summary of output states Improved programmable event log (2) showing date and time Manual fuel pump control Alternative configuration Multiple date and time scheduler 3 Programmable Maintenance alarms with comms alert Customisable status screens Low fuel level alarm delay Charge alternator fail warning and shutdown alarms with user programmable delay Independent Earth fault trip Sleep mode Load switching (Load shedding and dummy load outputs) Manual speed trim (on CAN engines that support this feature) Additional display screens to help with modem diagnostics Security levels PC software has password system to control access to PC software features Operator configurable virtual LEDs visible in SCADA RANGE 1V - 333V (L-N) Hz - 6Hz (Minimum 1V AC Ph-N) ACCURACY 1% of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 MAINS/UTILITY INPUT (DSE732 ONLY) RANGE 1V - 333V (L-N) Hz - 6Hz (Minimum 1V AC Ph-N) ACCURACY 1% of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 CT S BURDEN.VA PRIMARY RATING 1A - 8A (user selectable) SECONDARY RATING 1A or A secondary (user selectable) ACCURACY OF MEASUREMENT 1% of full load rating RECOMMENDATIONS Class 1 required for instrumentation Protection class required if using for protection Continued on page 2

22 SPECIFICATION MAGNETIC PICKUP VOLTAGE RANGE +/-.V minimum (during cranking) to 7V peak FREQUENCY RANGE, Hz (max) RELAY OUTPUTS OUTPUT A (FUEL) 1 Amp DC at supply voltage OUTPUT B (START) 1 Amp DC at supply voltage OUTPUTS C & D 8 Amp 2V (Volt free) AUXILIARY OUTPUTS E,F,G,H 2 Amp DC at supply voltage DIMENSIONS OVERALL 24mm x 181.1mm x 41.7mm 9.4 x 7.1 x 1.6 PANEL CUT-OUT 22mm x 16mm 8.7 x 6.3 Max panel thickness 8mm (.3 ) TESTING STANDARDS ELECTRICAL SAFETY/ ELECTROMAGNETIC COMPATIBILITY BS EN 69 Safety of Information Technology Equipment, including Electrical Business Equipment BS EN EMC Generic Immunity Standard (Industrial) BS EN EMC Generic Emission Standard (Industrial) ENVIRONMENTAL BS EN Cold Temperature -3 o C BS EN Hot Temperature +7 o C BS EN HUMIDITY Test Db cyclic % 4 o C for 48 hours BS EN VIBRATION sweeps at 1 octave/minute in each of 3 major axes Hz to +/-7.mm constant displacement 8Hz to 2gn constant acceleration BS EN SHOCK 3 half sine shocks in each of 3 major axes 1gn amplitude, 11mS duration BS EN 629 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES IP6 (Front of module when installed into the control panel with the supplied sealing gasket) BENEFITS 132 x 64 pixel ratio makes information easy to read Real time clock provides accurate event logging PC software is license free Set maintenance periods can be configured to maintain optimum engine performance Ethernet communications provides advanced remote monitoring at low cost Modules can be integrated into building management systems Preventative maintenance avoids expensive engine down time Advanced PCB layout ensures high reliability Robust design Extensive performance monitoring OPERATION The modules are operated via the START, STOP, AUTO and MANUAL soft touch membrane buttons on the front panel. The DSE732 also has a TEST button. Both modules include load switch buttons. The main menu system is accessed using the five navigation buttons to the left of the LCD display. CONFIGURATION The modules can be configured using the front panel buttons or by using the PC software and a USB lead. COMMUNICATIONS The DSE73 & DSE732 have a number of different communication capabilities. SMS Messaging When the module detects an alarm condition, it has the ability to send an SMS message to a dedicated mobile number (s), notifying an engineer of the exact time, date and reason why the engine failed (GSM Modem and SIM Card required). Remote Communications When the module detects an alarm state, it dials out to a PC notifying the user of the condition (Modem required). Remote Control The module can be controlled remotely using either a GSM Modem, Ethernet via DSE86/86 or via RS48. Using a modem allows the module to be controlled from any distance. Using RS48 limits the distance to 1km (.6 miles). Building Management The module has been designed to be integrated into new and existing building management systems, using RS48. PC Software The module has the ability to be configured and monitored from a remote PC, using the PC software and a USB lead. INPUTS & OUTPUTS Analogue inputs are provided for oil pressure, coolant temperature and fuel level. These connect to conventional engine mounted resistive sender units to provide accurate monitoring and protection facilities. They can also be configured to interface with digital switch type inputs for low oil pressure and high coolant temperature shutdowns. Eight user configurable digital inputs are also included, plus one flexible sender. Relays are provided for fuel solenoid output, start output and six additional configurable outputs. On these configurable outputs a range of different functions, conditions or alarms can be selected. INSTRUMENTATION The modules provide advanced metering facilities, displaying the information on the LCD display. The information can be accessed using the five-key menu navigation to the left of the display RELATED MATERIALS TITLE PART NO S DSE7xxx Manual 7-74 DSE72xx/73xx PC Software Manual 7-77 DSE213 Data Sheet 3-6 DSE217 Data Sheet 3-61 DSE248 Data Sheet 3-62 DSE86/86 Data Sheet -71 DSENET DSENet is a collection of expansion modules that have been created to work with DSENet compatible control modules. DSENet allows up to 2 different expansion devices to be used at a time. of these devices can be of the same type (excluding DSE213). The expansion modules available are: Available Now DSE217 Relay Output Expansion Module DSE213 Input Expansion Module DSE248 Annunciator Module Remote Display Module Coming Soon FET Output Expansion Module NFPA 1 Interface Module Identification Dongle EVENT LOG The module includes a comprehensive event log that shows the most recent 2 alarm conditions and the date and time that they occurred. This function assists the user when fault finding and maintaining a generating set. ELECTRONIC ENGINE COMPATABILITY CAT Cummins Deutz John Deere MTU Perkins Scania Volvo IVECO Generic Plus additional manufacturers NEMA RATING (APPROXIMATE) 12 (Front of module when installed into the control panel with the supplied sealing gasket) Generator Instruments Volts, Hz, Amps, kw, kva, Pf, kwh, kvar, kvarh, KVAh Engine Instruments RPM, Oil Pressure, Coolant Temperature, Hours Run, Charging Voltage, Battery Volts. Electronic Engines Enhanced Instrumentation and Engine ECU diagnostics via electronic engine interface. Generator Instruments Volts, Hz, Amps, kw, kva, Pf, kwh, kvar, kvarh, KVAh Engine Instruments RPM, Oil Pressure, Coolant Temperature, Hours Run, Charging Voltage, Battery Volts. Electronic Engines Enhanced instrumentation and Engine ECU diagnostics via electronic engine interface. Mains/Utility Instruments Volts, Frequency, Amps (optional when CT s are fitted load side of the line) ELECTRONIC ENGINE CAPABILITY

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK 2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK 574 kwm at 1500 rpm 598 kwm at 1800 rpm Economic Power Mechanically operated unit fuel injectors with electronic control combined with carefully matched

More information

2200 Series 2206A-E13TAG2 Diesel Engine - ElectropaK

2200 Series 2206A-E13TAG2 Diesel Engine - ElectropaK 2200 Series 2206A-E13TAG2 Diesel Engine - ElectropaK 349 kwm at 1500 rpm 381 kwm at 1800 rpm The 2200 Series engine has been developed using the latest engineering techniques and builds on the strengths

More information

2000 Series 2206C-E13TAG2 Diesel Engine ElectropaK rpm

2000 Series 2206C-E13TAG2 Diesel Engine ElectropaK rpm The 2200 range has been developed using the latest engineering techniques and builds on the strengths of the already very successful 2000 Series family. Developed from a proven heavy-duty industrial base,

More information

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data Réf. 3303 GB - 2.33 / e - 04.02 35 30 25 20 15 10 ALTERNATORS LSA 50.1-4 Pole Electrical and mechanical data ELECTRICAL DATA ALTERNATORS LSA 50.1-4P 50 Hz - 1500 r.p.m. Insulation class H Excitation system

More information

2200 Series 2206A-E13TAG3 Diesel Engine ElectropaK rpm

2200 Series 2206A-E13TAG3 Diesel Engine ElectropaK rpm The 2200 Series engine has been developed using the latest engineering techniques and builds on the strengths of the already very successful 2000 Series family and addresses today s uncompromising demands

More information

FUSTEQ Series PK 502 FQ* DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION.

FUSTEQ Series PK 502 FQ* DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION. 1 FUSTEQ Series MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION PK 502 FQ* GENERATING SET PERFORMANCE

More information

PRP kwe 144 kwe 160. LTP kwe 160 kwe 176. cos φ 0,8 0,8

PRP kwe 144 kwe 160. LTP kwe 160 kwe 176. cos φ 0,8 0,8 1 FUSTEQ Series MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL ULTRA SILENT VERSION PK 201 FQ* GENERATING SET PERFORMANCE

More information

2800 Series 2806C-E18TAG1A Diesel Engine ElectropaK 598 kwm at 1800 rpm

2800 Series 2806C-E18TAG1A Diesel Engine ElectropaK 598 kwm at 1800 rpm The Perkins 2800 Series is a family of well-proven 6 cylinder 16 and 18 litre inline diesel engines, designed to address today s uncompromising demands within the power generation industry with particular

More information

2800 Series 2806A-E18TAG2 Diesel Engine ElectropaK 609 kwm at 1500 rpm

2800 Series 2806A-E18TAG2 Diesel Engine ElectropaK 609 kwm at 1500 rpm The Perkins 2800 Series is a family of well-proven 6 cylinder 16 and 18 litre in-line diesel engines, designed to address today s uncompromising demands within the power generation industry with particular

More information

2500 Series 2506A-E15TAG3 Diesel Engine ElectropaK Non-Emissions compliant 490 kwm at 1800 rpm

2500 Series 2506A-E15TAG3 Diesel Engine ElectropaK Non-Emissions compliant 490 kwm at 1800 rpm The 2500 Series engine has been developed using the latest engineering techniques and builds on the strengths of the already very successful 2000 Series family and addresses today s uncompromising demands

More information

Low Voltage Alternators - 4 pole LSA 44.3

Low Voltage Alternators - 4 pole LSA 44.3 LSA 44.3 70 to 150 kva - 50 Hz / 88 to 188 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 44.3 alternator is designed to be suitable for typical generator applications,

More information

V 400 / 230 V. PRP kva 200 kva -- LTP kva 220 kva -- PRP kwe 160 kwe -- LTP kwe 176 kwe -- cos φ 0,8 --

V 400 / 230 V. PRP kva 200 kva -- LTP kva 220 kva -- PRP kwe 160 kwe -- LTP kwe 176 kwe -- cos φ 0,8 -- 1 FUSTEQ SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL ULTRA SILENT VERSION PK 221 FQ GENERATING SET PERFORMANCE

More information

PRP kwe 400 kwe 408. LTP kwe 440 kwe 448. cos φ 0,8 0,8

PRP kwe 400 kwe 408. LTP kwe 440 kwe 448. cos φ 0,8 0,8 1 MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION PK 552 W 3* GENERATING SET PERFORMANCE PERFORMANCES

More information

700 KVA / 550 KW POWERED by

700 KVA / 550 KW POWERED by 700 KVA / 550 KW POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

LSA 52.3 Low Voltage Alternators - 4 pole

LSA 52.3 Low Voltage Alternators - 4 pole LSA 52.3 Low Voltage Alternators - 4 pole 1860 to 2500 kva - 50 Hz / 2230 to 3000 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 52.3 alternator is designed to be

More information

PRP kwe 252 kwe 276. LTP kwe 273 kwe 306. cos φ 0,8 0,8

PRP kwe 252 kwe 276. LTP kwe 273 kwe 306. cos φ 0,8 0,8 1 TENAX V SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL OPEN VERSION VO 351 TV* SOUNDPROOF VERSION GENERATING

More information

PRP kwe 36 kwe 44,8. LTP kwe 40 kwe 49,3. cos φ 0,8 0,8

PRP kwe 36 kwe 44,8. LTP kwe 40 kwe 49,3. cos φ 0,8 0,8 1 ENERMAX SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION PK 51 TSX GENERATING SET PERFORMANCE

More information

FUSTEQ Series PK 22 FQ ULTRA SILENT VERSION. 50 Hz 60 Hz DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL

FUSTEQ Series PK 22 FQ ULTRA SILENT VERSION. 50 Hz 60 Hz DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL 1 FUSTEQ Series MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL ULTRA SILENT VERSION PK 22 FQ GENERATING SET PERFORMANCE

More information

640 KW / 800 KVA POWERED by

640 KW / 800 KVA POWERED by 640 KW / 800 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

PRP kwe 400 kwe 456. LTP kwe 440 kwe 514. cos φ 0,8 0,8

PRP kwe 400 kwe 456. LTP kwe 440 kwe 514. cos φ 0,8 0,8 1 TENAX V SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL OPEN VERSION VO 601 TV* SOUNDPROOF VERSION GENERATING

More information

FUSTEQ SERIES PK 36 FQ ULTRA SILENT VERSION. 50 Hz 60 Hz DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL

FUSTEQ SERIES PK 36 FQ ULTRA SILENT VERSION. 50 Hz 60 Hz DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL 1 FUSTEQ SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL ULTRA SILENT VERSION PK 36 FQ GENERATING SET PERFORMANCE

More information

PRP kwe 200 kwe 200. LTP kwe 220 kwe 220. cos φ 0,8 0,8

PRP kwe 200 kwe 200. LTP kwe 220 kwe 220. cos φ 0,8 0,8 1 ENERMAX SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL SOUNDPROOF VERSION VO 276 TSX* GENERATING SET PERFORMANCE

More information

80 KW / 100 KVA POWERED by

80 KW / 100 KVA POWERED by 80 KW / 100 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

4000 Series TAG3A Diesel Engine ElectropaK rpm

4000 Series TAG3A Diesel Engine ElectropaK rpm The Perkins 4000 Series is a family of 6, 8, 12 and 16 cylinder diesel engines, designed to address today s uncompromising demands within the power generation industry with particular aim at the standby

More information

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power LSP88S3 Powered by 50HZ Water-cooled Three Phase Diesel Model LSP88S3 Standby Power KVA 88 KW 70 Prime Power KVA 80 KW 64 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Perkins is one of the largest

More information

PERKINS SERIE E18TAG PNY600. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. 350x153x HCI534E. 145 x :1 /Enfriado por aire

PERKINS SERIE E18TAG PNY600. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. 350x153x HCI534E. 145 x :1 /Enfriado por aire PERKINS SERIE E18TAG PNY600 681 750 545 600 PNY600 Perkins E18TAG3 HCI534E 145 x 183 14.5:1 /Enfriado por aire 654 2241 11 156 llame a fábrica. llame a fábrica. 542 852 Dimensiones (Largo x Ancho x Alto)cm

More information

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480 1500 KW / 1875 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000kW. Through our commitment

More information

PERKINS SERIE E14 PNY350 PNY400 PNY350 PNY400 HCI434F HCI434E. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg.

PERKINS SERIE E14 PNY350 PNY400 PNY350 PNY400 HCI434F HCI434E. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. PERKINS SERIE E14 PNY350 Perkins E14TAG2 HCI434E 12 5.91 x 6.30 (150 x160) 15.3:1 /Enfriado por aire PNY400 Perkins E14TAG3 HCI434F 12 5.91 x 6.89(150 x 175) 14.5:1 /Enfriado por aire 1207(900) 1528(1140)

More information

PRP kwe 10,4 kwe -- LTP kwe 11,4 kwe -- cos φ 0,8 --

PRP kwe 10,4 kwe -- LTP kwe 11,4 kwe -- cos φ 0,8 -- 1 TENAX K SERIES MODEL MODELE MODELO MODELLO POWERED BY DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL OPEN VERSION PK 14 TK SOUNDPROOF VERSION GENERATING

More information

16 KW / 20 KVA POWERED by

16 KW / 20 KVA POWERED by 16 KW / 20 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

130 KW / 165 KVA POWERED by

130 KW / 165 KVA POWERED by 130 KW / 165 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0. 350 KW / 438 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000kW. Through our commitment to

More information

28 KW / 28 KVA POWERED by

28 KW / 28 KVA POWERED by 28 KW / 28 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

55 KW / 70 KVA POWERED by

55 KW / 70 KVA POWERED by 55 KW / 70 KVA POWERED by MODEL TP-P55-T3-60-UL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our

More information

PERKINS SERIE E15TAG PNY500 PNY500. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. HCI534D. 135 x /Enfriado por aire

PERKINS SERIE E15TAG PNY500 PNY500. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. HCI534D. 135 x /Enfriado por aire PERKINS SERIE E15TAG PNY500 569 455 PNY500 Perkins E15TAG4 HCI534D 135 x 167 16.1 /Enfriado por aire 582 2574 10 128 332 132 511 866 105.3 350x153x205 3475 ENT SYSTEM EM AG UALITY ED Q MA IFI N RT UALITY

More information

18 KW / 18 KVA POWERED by

18 KW / 18 KVA POWERED by 18 KW / 18 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0. 275 KW / 344 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

1800 KW / 2250 KVA POWERED by

1800 KW / 2250 KVA POWERED by 1800 KW / 2250 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

1000 KW / 1250 KVA POWERED by

1000 KW / 1250 KVA POWERED by 1000 KW / 1250 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55 60 KW / 75 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

SIDE VIEW FRONT VIEW

SIDE VIEW FRONT VIEW MODELS PNE 15 PNY 15 112.24 112.24 97. (38.18") 61. 66. 66. 15.24 22. 131. 175. SIDE VIEW 22. FRONT VIEW DESCRIPTION TOP VIEW RADIATOR: 43C-15G -THE GENSET DIMENSIONS ARE THE SAME BY FAMILY MODEL, THERE

More information

45 KW / 55 KVA POWERED by

45 KW / 55 KVA POWERED by MODEL 45 KW / 55 KVA POWERED by Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8 Model:KYP681 Generating Rates POWER RATING POWER KVA KW STANDBY 750 600 Rated Speed R.P.M 1800 Standard Voltage V 480 PRIME Available Voltages V 480/277-440/254-220/127-208/120 Rated at power factor Cos

More information

130 KW / 165 KVA POWERED by

130 KW / 165 KVA POWERED by 130 KW / 165 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8 Model:KYP500 Generating Rates POWER RATING POWER KVA KW STANDBY 563 450 Rated Speed R.P.M 1800 Standard Voltage V 480 PRIME Available Voltages V 480/277-440/254-220/127-208/120 Rated at power factor Cos

More information

PRP kwe 728 kwe 832. LTP kwe 800 kwe 916

PRP kwe 728 kwe 832. LTP kwe 800 kwe 916 1 ULTRA SILENT Series MODEL MODELE MODELO MODELLO DIESEL GENERATOR GROUPE ELECTROGENE DIESEL GRUPO ELECTROGENO DIESEL GRUPPO ELETTROGENO DIESEL CU 1000 WB POWERED BY ULTRA SILENT VERSION GENERATING SET

More information

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8 Model:KYP400 Generating Rates POWER RATING POWER KVA KW STANDBY 438 350 Rated Speed R.P.M 1800 Standard Voltage V 480 PRIME Available Voltages V 480/277-440/254-220/127-208/120 Rated at power factor Cos

More information

600 KW / 750 KVA POWERED by

600 KW / 750 KVA POWERED by 600 KW / 750 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480 150 KW / 195 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

4000 Series TAG4 Diesel Engine ElectropaK rpm net standby power

4000 Series TAG4 Diesel Engine ElectropaK rpm net standby power The Perkins 4000 Series is a family of 6, 8, 12 and 16 cylinder diesel engines, designed to address today s uncompromising demands within the power generation industry with particular aim at the standby

More information

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0. 1020 KW / 1275 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000kW. Through our commitment

More information

4000 Series TRG3 Diesel Engine ElectropaK rpm

4000 Series TRG3 Diesel Engine ElectropaK rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs. In the world of power generation success

More information

204 KW / 254 KVA POWERED by

204 KW / 254 KVA POWERED by 204 KW / 254 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power 4000 Series 4006-23TAG2A Diesel Engine ElectropaK 695 kwm @ 1500 rpm net standby power The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising

More information

2000 KW / 2500 KVA POWERED by

2000 KW / 2500 KVA POWERED by 2000 KW / 2500 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

TPD2250H6.3 TECHNICAL DATA

TPD2250H6.3 TECHNICAL DATA TECHNICAL DATA DIESEL GENERATING SET TONTEK POWER LIMITED GREEN POWER SUPPLIER 50HZ www.tontekpower.com Page: 1/10 Specifications may change without Notice TPD2250H6.3 2250KVA/1800KW POWERED BY CUMMINS

More information

1100 Series 1103A-33TG2 Diesel Engine ElectropaK 67.5 kwm / rpm

1100 Series 1103A-33TG2 Diesel Engine ElectropaK 67.5 kwm / rpm Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs. In the world of power generation success

More information

30 KW / 40 KVA POWERED by

30 KW / 40 KVA POWERED by 30 KW / 40 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva J170UC MODEL DIESEL GENSET J170UC Stand-by Power @ 60Hz 170kW / 213 kva Prime Power @ 60Hz 155 kw / 193 kva Standard Features General features : Engine (JOHN DEERE, 6068HF275-187 ) Engine EPA Carb Charge

More information

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva J440K Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J440K 352kW / 440 kva 320 kw / 400 kva General features : Engine (JOHN DEERE, 6125HF070-387 ) Charge alternator 24 V,

More information

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH Voltage kva 380-415 400 Prime* kw 320 kva 440 Standby* kw 352 Ampere 557 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

4000 Series 4008TAG2 Diesel Engine Electro Unit rpm net standby power

4000 Series 4008TAG2 Diesel Engine Electro Unit rpm net standby power The Perkins 4000 Series is a family of 6, 8, 12 and 16 cylinder diesel engines, designed to address today s uncompromising demands within the power generation industry with particular aim at the standby

More information

WPS100/S EP Series. Features:

WPS100/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva V500UC MODEL DIESEL GENSET V500UC Stand-by Power @ 60Hz 500kW / 625 kva Prime Power @ 60Hz 455 kw / 568 kva Standard Features General features : Engine (VOLVO, TAD1641GE ) Engine EPA Carb Charge alternator

More information

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva JS275UC MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET JS275UC 275kW / 344 kva 250 kw / 313 kva Standard Features General features : Engine (JOHN DEERE, 6081HF070-318 ) Engine EPA Carb Charge

More information

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Cummins KTA38-G5 diesel engine Leroy Somer LSA 49.1 L11 alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty

More information

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva JS200UC MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET JS200UC 200kW / 250 kva 182 kw / 227 kva Standard Features General features : Engine (JOHN DEERE, 6068HF475 ) Engine EPA Carb Charge

More information

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva J100U MODEL DIESEL GENSET J100U Stand-by Power @ 60Hz 100kW / 125 kva Prime Power @ 60Hz 91 kw / 114 kva Standard Features General features : Engine (JOHN DEERE, 4045HF120 ) Charge alternator 12 V, Governor:Meca

More information

WPS350/S EP Series. Features:

WPS350/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva J200K Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J200K 160kW / 200 kva 145 kw / 182 kva General features : Engine (JOHN DEERE, 6068HF120-183 ) Charge alternator 12 V,

More information

WPS150/S EP Series. Features:

WPS150/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva GS500K MODEL DIESEL GENSET GS500K Stand-by Power @ 50Hz 440kW / 550 kva Prime Power @ Hz 400 kw / 500 kva Standard Features General features : Engine (VOLVO, TAD1631GE ) Charge alternator 24 V, Governor:Electronic

More information

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva J60UC MODEL DIESEL GENSET J60UC Stand-by Power @ 60Hz 60kW / 75 kva Prime Power @ 60Hz 55 kw / 68 kva Standard Features General features : Engine (JOHN DEERE, 4045TF270 ) Engine EPA Carb Charge alternator

More information

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power LSC220S3 Powered by Cummins 50HZ Water-cooled Three Phase Diesel Model LSC220S3 Standby Power KVA 220 KW 176 Prime Power KVA 200 KW 160 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Cummins has

More information

1100 Series 1104C-44TAG1 Diesel Engine ElectropaK rpm

1100 Series 1104C-44TAG1 Diesel Engine ElectropaK rpm Building upon Perkins proven reputation within the power generation industry, the Perkins 1100 Series range of ElectropaK engines now fit even closer to the needs of their customers. With the 1104C-44TAG1

More information

WPS60/S EP Series. Features:

WPS60/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life

More information

WPS250/S EP Series. Features:

WPS250/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Specification sheet Diesel generator set QSK78 series engine 2750kVA - 3000kVA 50 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance,

More information

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE. Engine ref. Alternator ref. Performance class 4045TF120 KH00771T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel APM403 Optional

More information

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE. Engine ref. Alternator ref. Performance class 6068HF120-153 KH01340T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel APM403 Optional

More information

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva V300UC MODEL DIESEL GENSET V300UC Stand-by Power @ 60Hz 300kW / 375 kva Prime Power @ 60Hz 273 kw / 341 kva Standard Features General features : Engine (VOLVO, TAD941GE ) Engine EPA Carb Charge alternator

More information

64 KW / 80 KVA POWERED by

64 KW / 80 KVA POWERED by 64 KW / 80 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

1100 Series 1104D-E44TG1 Diesel Engine ElectropaK 71.8 kwm (96 hp) net standby 1800 rpm

1100 Series 1104D-E44TG1 Diesel Engine ElectropaK 71.8 kwm (96 hp) net standby 1800 rpm The Perkins 1104D-E44TG ElectropaKs are the latest addition to the 1100 Series Electric Power line-up. Offering improved power density from a compact package, these ElectropaKs build on Perkins reputation

More information

Rental Power QSL9 series engine

Rental Power QSL9 series engine Specification sheet Rental Power QSL9 series engine 250 kva - 300 kva 50 Hz 225 kw - 275 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing

More information

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH Prime* Voltage kva kw kva 380-415 180 144 200 Standby* kw 160 Ampere 251 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

1100 Series 1104D-44TG3 Diesel Engine ElectropaK 54 kwm (72 hp) net prime 1500 rpm 59 kwm (79 hp) net standby 1500 rpm

1100 Series 1104D-44TG3 Diesel Engine ElectropaK 54 kwm (72 hp) net prime 1500 rpm 59 kwm (79 hp) net standby 1500 rpm The Perkins 1104D turbocharged ElectropaKs are the latest addition to the 1100 Series ElectropaK range. Perkins has developed this engine in line with our customer s needs by providing the options of either

More information

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings. Technical Data @Perkins 2800 Series 2806A-E18TAG1A Diesel Engine - ElectropaK 2806A-E18TAG2 Basic technical data Number of cylinders..................................................... 6 Cylinder arrangement...................................

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE. Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 DESCRIPTIVE Kohler Co. Provides one-source responsibility for the generating system and accessories. The generator set and its components

More information

K17M POWER 240 MONO 230 MONO 220 MONO

K17M POWER 240 MONO 230 MONO 220 MONO Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional Control Panel Optional control panel KDI1903M KH00630T

More information

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine Specification sheet Diesel generator set QSK78 series engine 1950 kw - 2500 kw Description Cummins commercial generator sets are fully integrated power generation systems providing optimum performance,

More information

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva J40UC MODEL DIESEL GENSET J40UC Stand-by Power @ 60Hz 40kW / 50 kva Prime Power @ 60Hz 36 kw / 45 kva Standard Features General features : Engine (JOHN DEERE, 3029TF270 ) Engine EPA Carb Charge alternator

More information

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE. Engine ref. Alternator ref. Performance class TAD1641GE KH02450T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional

More information

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power LSC500S3 Powered by Cummins 50HZ Water-cooled Three Phase Diesel Model LSC500S3 Standby Power KVA 500 KW 400 Prime Power KVA 450 KW 360 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Cummins has

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing Engine ref. Alternator ref. Performance class TAD1345GE KH02070T G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Hz Voltage (V) 400/230 Standard Control Panel APM403 Optional control panel APM802 Optional

More information

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/ General Characteristics Model Name AJD 33 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029DF128 Alternator Made and Model ECP 28-VL/4 A Control Panel Model 7320 Canopy AK 20 Power

More information

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information