Best-selling Basic Switch Boasting High Precision and Wide Variety

Size: px
Start display at page:

Download "Best-selling Basic Switch Boasting High Precision and Wide Variety"

Transcription

1 General-purpose Basic Switch Z CSM_Z_DS_E_4_4 Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in contact form for your selection: basic, split-contact, maintained-contact, and adjustable contact gap types. A series of standard models for micro loads is available. A series of molded terminal-type models incorporating safety terminal protective cover is available. Be sure to read Safety Precautions on page 6 and Safety Precautions for All Basic Switches. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Configuration Basic models Split-contact models Maintained-contact models General-purpose Drip-proof General-purpose General-purpose Without terminal protective cover With terminal protective cover Molded terminal Refer to page. Refer to page. Refer to page. Refer to page. Refer to page 4. Refer to page 4. Basic Models General-purpose A variety of actuators is available for a wide range of application. The contact mechanism of models for micro loads is a crossbar type with gold-alloy contacts, which ensures highly reliable operations for micro loads. Contact Gap: H: 0.0 mm (extra-high-sensitivity) H: 0. mm (high-sensitivity, micro voltage current load) G: 0. mm (standard) E:.8 mm (high-capacity) Drip-proof These Switches use a rubber boot on the actuator and adhesive fill between the case and cover to increase resistance to drips. Models with drip-proof terminal protective covers and molded terminals with resin filling are also available. Split-contact Models This type is identical in construction to the general-purpose basic switch except that it has two pairs of simultaneous acting contacts by splitting moving contacts. Since the moving contacts are connected to a common terminal, either parallel or series connection is possible. Highly reliable micro load switching is ensured if the model is used as a twin-contact switch. Maintained-contact Models The maintained-contact type has a reset button at the bottom of the switch case, in addition to the pushbutton (plunger) located on the opposite side of the reset button. Use these buttons alternately. Since the Switch has greater pretravel than overtravel, it is suitable for use in reversible control circuits, manual reset circuits, safety limit circuits, and other circuits which are not preferable for automatic resetting. (For further details, refer to individual datasheets.)

2 Model Number Legend Basic Models ()()()(4) () () Ratings 0 : 0. A (micro load) : A () Contact Gap H : 0.0 (extra-high-sensitivity) H : 0. mm (high-sensitivity, micro load) G : 0. mm (standard) E :.8 mm (high-capacity) () Actuator None : Pin plunger S : Slim spring plunger D : Short spring plunger K : Spring plunger (medium ) K : Spring plunger (high ) Q : Panel mount plunger (low ) Q : Panel mount plunger (medium ) Q8 : Panel mount plunger (high ) Q : Panel mount roller plunger Q : Panel mount cross roller plunger L : Leaf spring (high OF) L : Roller leaf spring W : Short hinge lever W : Hinge lever (low OF) W : Hinge lever (medium OF) W : Hinge lever (high OF) W4 : Low-force hinge lever W44 : Long hinge lever W78 : Low-force wire hinge lever (low OF) W : Low-force wire hinge lever (high OF) W : Short hinge roller lever W : Hinge roller lever W : Hinge roller lever (large roller) W49 : Short hinge cross roller lever W4 : Hinge cross roller lever W77 : Unidirectional short hinge roller lever (low OF) M : Reverse hinge lever M : Reverse short hinge roller lever M : Reverse hinge roller lever NJ : Flexible rod (high OF) NJS : Flexible rod (low OF) (4) Degree of Protection None : General-purpose : Drip-proof (not include the terminals) A : Drip-proof (including the terminals) () Terminals None : Solder terminal B : Screw terminal (with toothed washer) BV : Screw terminal with terminal cover (for Z-G@A only) Note: For combinations of models, Ordering Information on page to 6. Standard Models (Drip-proof Type/Molded Terminals) () ()() (4) () Drip-proof Type () Lead Outlets None : VSF 9 : VCT () Directions of Lead Outlets (See following diagrams.) L : Left R : Right D : Descending (4) Length of Lead Outlets : m : m Split-contact Models Z-0F@Y-B () ()()(4) () () Ratings 0 : 0 A (split-contact models) () Contact Gap F : mm (high-capacity) () Actuator None : Pin plunger S : Slim spring plunger D : Short spring plunger Q : Panel mount plunger Q : Panel mount roller plunger W : Hinge lever W : Short hinge roller lever W : Hinge roller lever M : Reverse short hinge roller lever (4) Construction Y : Split-contact models () Terminals B : Screw terminal (with toothed washer) L Type D Type R Type Maintained-contact Models Z--E@R () ()()(4) () Ratings : A () Contact Gap E :.8 mm (high capacity) () Actuator None : Pin plunger S : Slim spring plunger W : Hinge lever (4) Structure R : Maintained-contact models

3 Z Ordering Information Main Unit Basic Models (General-purpose) Classification Actuator Contact gap Terminal * Pin plunger Slim spring plunger Short spring plunger Panel mount plunger Standard High-sensitivity G (0. mm) Model H (0. mm) Model Z-H Z-E Z-0H Z-H-B Z-E-B Z-0H-B Z-GS Z-HS Z-GS-B Z-HS-B Z-GD Z-HD Z-GD-B Z-HD-B Z-GQ Z-GQ Z-HQ Z-GQ-B Z-HQ-B High Z-GQ8-B Z-GQ8 Z-HQ Z-HQ-B Panel mount cross roller plunger Z-GQ Z-HQ Z-GQ-B Z-HQ-B Z-GL Z-GL Z-GL-B Z-GW Z-GW-B Lowforce wire hinge lever Z-0HQ Z-0HQ-B Z-EQ Z-EQ-B Z-EQ Z-EQ-B -- Z-HW Medium Z-GW-B High Z-GW-B Z-GW Z-GW4 Z-HW4 Z-GW4-B Z-HW4-B Z-HW78 Z-HW78-B Z-HW Z-HW-B Z-HW Z-GW-B Z-HW-B Short hinge cross roller lever Z-GW49-B Reverse hinge lever * Z-EQ Z-EQ-B Z-GW Unidirectional short hinge roller lever Z-HW-B Z-GW49 Standard Z-GW Z-HW Z-GW-B Z-HW-B Large roller Z-GW-B Z-GW Z-GW4 Hinge cross roller lever Short hinge roller lever Hinge roller lever Z-0HD Z-0HD-B Z-GW High Z-ED Z-ED-B Z-GW-B Low Z-0HS Z-0HS-B Low Z-GW Z-GQ Z-GL-B Z-GQ-B Low-force hinge lever H (0. mm) Model Z-H Panel mount roller plunger Hinge lever E (.8 mm) Model Z-H-B Medium Short hinge lever Micro load Z-G Z-GQ-B Roller leaf spring High-capacity Z-G-B Low Leaf spring Extra-high sensitivity H (0.0 mm) Model Z-GW4-B -- Z-EW Z-0HW Z-EW-B Z-0HW-B -- Z-GW77 Parallel Z-GW77-B Z-GM Z-GM-B Z-GM Reverse short hinge roller lever * Z-GM-B Reverse hinge roller lever * Z-GM-B Z-GM *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed.

4 Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Actuator Standard High-sensitivity Short spring plunger Z-GD-B Z-GQ Panel mount plunger Z-GQ-B Z-GQ8-B Z-GQ Panel mount roller plunger Z-GQ-B Panel mount cross roller plunger Z-GQ-B Short hinge lever Z-GW-B Z-GW Hinge lever Z-GW-B Low-force hinge lever Z-GW4-B Z-HW4-B Low-force hinge wire lever Z-HW78-B Z-GW Short hinge roller lever Z-GW-B Z-GW Hinge roller lever Z-GW-B Reverse short hinge roller lever Z-GM-B Reverse hinge roller lever Z-GM-B Minimum order lot (pcs) 0 Split-contact Models Contact gap F (.0 mm) Actuator Terminal * Model Pin plunger Z-0FY-B Slim spring plunger Z-0FSY-B Short spring plunger Z-0FDY-B Panel mount plunger Z-0FQY-B Panel mount roller plunger Z-0FQY-B Hinge lever Z-0FWY-B Short hinge roller lever Z-0FWY-B Hinge roller lever Z-0FWY-B Reverse short hinge roller lever * Z-0FMY-B *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Maintained-contact Models Actuator Pin plunger Slim spring plunger Hinge lever Model Z-ER Z-ESR Z-EWR 4

5 Basic Models (Drip-proof Models Standard, Microload ) Actuator Pin plunger Short spring plunger Spring plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller leaf spring Short hinge lever Long hinge lever Hinge lever Short hinge roller lever Hinge roller lever Classification Standard Micro load Contact gap G (0. mm) H (0. mm) Drip-proof terminal protective cover Not provided Provided Not provided Terminal * Model Model Model Z-G Z-0H Z-G-B Z-GA-BV Z-0H-B Z-GD Z-0HD Z-GD-B Z-0HD-B Low Z-GK Z-GK-B High Z-GK Z-GK-B Z-GKA-BV Z-GQ Z-GQ-B Z-GQA-BV Z-GQ Z-GQ-B Z-GQA-BV Z-GQ-B Z-GQA-BV Z-GL Z-GL-B Z-GL Z-GL-B Z-GW Z-GW-B Z-GW44 Z-GW44-B Z-GW44A-BV Z-GW Z-GW-B Z-GWA-BV Z-GW Z-0HW Z-GW-B Z-GWA-BV Z-0HW-B Z-GW Z-GW-B Z-GWA-BV Unidirectional short hinge roller lever Z-GW77 Z-GW77-B Z-GW77A-BV Reverse hinge lever * Reverse short hinge roller lever * Reverse hinge roller lever * Flexible rod (coil spring) * Z-GM Z-GM-B Z-GM Z-GM-B Z-GM Z-GM-B Z-GNJ Z-GNJ-B *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. *. The tip is made of resin. Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Standard Minimum order Actuator Contact gap G (0. mm) lot (pcs) Short spring plunger Z-GD-B Spring plunger Z-GK-B Z-GW44-B Hinge lever Z-GW Z-GW-B 0 Short hinge roller lever Z-GW Z-GW-B Hinge roller lever Z-GW-B Flexible rod (coil spring) Z-GNJ-B

6 Basic Models (Drip-proof Models High-sensitivity ) Classification High-sensitivity Contact gap H (0. mm) Drip-proof terminal protective cover Not provided Actuator Terminal * Model Flexible rod (steel wire) Z-HNJS Z-HNJS-B Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification High-sensitivity Minimum order Actuator Contact gap H (0. mm) lot (pcs) Flexible rod (steel wire) Z-HNJS-B 0 * : Solder terminal : Screw terminal Specifications Ratings (Basic, Split-contact and Maintained contact Models) Z- (Except Micro Load and Flexible Rod Models) Contact gap G, H, H, E G H, H E * Figures in parentheses are for the Z-HW, Z-HW78(-B) and Z-H(-B) models, the AC ratings of these models are and 0 V only. Z- (Flexible Rod Models) Z-0F Item Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Rated NC NO NC NO NC NO NC NO voltage VAC 0 VAC 00 VAC * 8 VDC 4 VDC 0 VDC VDC 0 VDC 8 VDC 4 VDC 0 VDC VDC 0 VDC 8 VDC 4 VDC 0 VDC VDC 0 VDC Rated voltage VAC 0 VAC 8 VDC 4 VDC 0 VDC VDC 0 VDC Contact gap Series connection Parallel connection (0) * (0) * (0) * (0) * Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO Item Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Rated NC NO NC NO NC NO NC NO voltage VAC 0 VAC 0 VDC VDC 0 VDC VAC 0 VAC 0 VDC VDC 0 VDC Z-0H Rated voltage Resistive load (A) NC NO VAC 0. 8 VDC 4 VDC 0 VDC Note:. The above current ratings are the values of the steady-state current.. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. Lamp load has an inrush current of 0 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current.. The normally closed and normally open ratings of reverse hinge lever models are opposite to each other. 6. The AC ratings of molded terminals are and 0 V only. 7. The ratings values apply under the following test conditions: () Ambient temperature: 0± C () Ambient humidity: 6±%RH () Operating frequency: 0 operations/min Use the switch within the operating range. Voltage (V) mw 0.6 ma Unusable range Minimum applicable load ma Micro load area Z-0H 0 00,000 Z-0H 800 mw 6 ma Standard load area Z-H, H Z-G Z-E Z-0FY Z-ER 00 ma 60 ma Current (ma) Z-@, Z-0FY VDC ma VDC 60 ma 6

7 Certified Standard Ratings Ask your OMRON representative for information on certified models. UL/CSA (General ratings only) Rated voltage Model Z- Z-0F Z-0H VAC A /8HP 6A /0HP 0.A 0 VAC A /4HP 6A /8HP 480 VAC A 6A 0 VDC 0.A VDC 0.A 0.6A 0 VDC 0.A 0.A Characteristics TÜV (EN608-) CCC (GB4048.) *. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Consult your OMRON representative for other models.) *. The values are for the Z-G pin plunger. *. The values are for the Z-0FY-B. *4. The values are for the pin plunger. The durability for models other than the pin plunger is 0,000,000 min. *. Malfunction: ms max. Contacts Specification Engineering Data Mechanical Durability (Z-G) Rated voltage Model Z-H@ Z-G@ Z-0H@ 0 VAC A A VAC 0. A 0 VDC 0. A Rated voltage Model Z-H@ Z-G@ Z-0H@ 0 VAC A A VAC 0. A 0 VDC 0. A Item Classification load and flexible rod) Z- (except micro Z-0H Z- (flexible rod) Z-0F Z-H Operating speed 0.0 mm to m/s * mm to m/s 0. mm to m/s * 0.0 mm to m/s Operating Mechanical 40 operations/min 0 operations/min 40 operations/min 40 operations/min frequency Electrical 0 operations/min Insulation resistance 00 MΩ min. (at 00 VDC) Contact resistance mω max. (initial value) 0 mω max. (initial value) mω max. (initial value) mω max. (initial value) mω max. (initial value) Dielectric strength Between contacts of same polarity Contact gap G:,000 VAC, 0/60 Hz for min Contact gap H: 600 VAC, 0/60 Hz for min Contact gap E:,00 VAC, 0/60 Hz for min Between contacts of same polarity Contact gap G:,000 VAC, 0/60 Hz for min Contact gap H: 600 VAC, 0/60 Hz for min Between contacts of same polarity Contact gap F:,00 VAC, 0/60 Hz for min Between contacts of same polarity 600VAC, 0/60Hz for min Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts,000 VAC, 0/60 Hz for min Vibration 0 to 0 Hz, -mm double Malfunction 0 to Hz, -mm double amplitude * resistance amplitude * 0 to Hz, -mm double amplitude * Shock Destruction,000 m/s max. resistance Malfunction 00 m/s max. * * 0 m/s max. * 00 m/s max. * * 00 m/s max. Durability Mechanical Contact gap G, H: 0,000,000 operations min. 00,000 operations 0,000,000 operations,000,000 operations min. Contact gap E: 00,000 operations min. * min. Electrical Contact gap G, H: 00,000 operations min. 00,000 operations 00,000 operations 00,000 operations min. Contact gap E: 00,000 operations min. min. min. Degree of General-purpose IP00 protection Drip-proof Equivalent to IP6 (except terminals) Degree of protection against electric shock Class I Proof tracking index (I) 7 Ambient operating General-purpose C to 80 C (with no icing) temperature Drip-proof C to 80 C (with no icing) Ambient operating General-purpose % to 8%RH humidity Drip-proof % to 9%RH Weight Approx. to 8 g Approx. 4 to 48 g Approx. 4 to 6 g Approx. g Item Classification Z- Z-0H Z-0F Contacts Shape Rivet Single crossbar Rivet Material Silver Gold alloy Silver Inrush current NC 0 A max. 0. A max. 40 A max. NO A max. 0. A max. 0 A max. Durability (x0 4 operations) 0,000,000,000, Ambient temperature: 0± C Ambient humidity: 6±%RH Without load Operating frequency: 40 operations/min Electrical Durability (Z-G) Durability (x0 4 operations),000,000, Ambient temperature: 0± C Ambient humidity: 6±%RH Operating frequency: 0 operations/min. VAC cos dia. = VAC cos dia. = VAC cos dia. = 0 VAC cos dia. = VAC cos dia. = 00 VAC cos dia. = Overtravel (mm) Switching Current (A) 7

8 Structure Z Basic Models Contact Form (SPDT) COM Note: The Z-GM is a reversible model and the NO and NC positions are reversed. Molded Terminals COM (Black) NC NO (Red) NC (White) NO ( ) indicates wire color. Split-contact Models Contact Form COM NO Note: The NO and NC terminal arrangement is reversed for Models with reverse operation (Z-0FM). Connection Example Series Connection NC NO NC Parallel Connection Note: The Z-GM is a reversible model and the NO and NC positions are reversed. Structure Drip-proof Construction Without Terminal Protective Cover Rubber boot Fixed contact (b) Movable spring Glued surface (adhesive is filled between case and cover) Movable contact Maintained-contact Models Contact Form Spring pivot Fixed contact (a) With Terminal Protective Cover COM NC NO Rubber boot (weather-resistive chloroprene is used) Pushbutton for resetting Stainless-steel stopper (improves sealing) Rubber packing (improves sealing between switch housing and terminal cover) Terminal protective covers are sold separately for maintenance purposes, which can be, however, used with the Z-@-BV models only. For details, refer to page. 8

9 Dimensions Z (Unit: mm) Mounting Use M4 screws with plane washers and spring washers to mount the Switch. Tighten each mounting screw securely to a torque of.8 to.47 N m. Two, 4. dia. mounting holes or M dia. When mounting the Switch to a panel, use a tightening torque of.94 to 4.9 N m for the hexagonal nuts on the actuator. Panel Mount Plunger Panel Mount Roller Plunger dia Basic Models Terminals Screw Terminals (-B) General-purpose and Split-contact Models Basic Models Solder Terminal (-A) ( -A is not included in the model numbers.) Split-contact Models Screw Terminals (Y-B) COM NO NC Three, M4. Terminal screws (with toothed washer) Appropriate terminal screw tightening torque: 0.78 to.8 N m. NO COM NC Note: With reverse action models (Z-GM), the positions of NO and NC terminals are reversed. Five, M.. terminal screws (with toothed washer) Appropriate terminal screw tightening torque: 0.49 to 0.78 N m. Note: With reverse action models (Z-0FM), the positions of NO and NC terminals are reversed. COM NO NO NC NC Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models (-B). The -A at the end of the model number for solder terminal models has been omitted. For details of the terminals, see above. Pin Plunger Z-G-B Z-H-B Z-H-B Z-E-B Z-0H-B Z-0FY-B Operating Characteristics Operating force OF Release force Pretravel Overtravel Movement Differential Operating Position.± dia. hole. dia..sr * 4. * Stainless-steel plunger Model Z-G-B Z-H-B Z-H-B Z-E-B Z-0H-B Z-0FY-B.4 to.4 N 0.4 mm 0. mm 0.0 mm.96 to. N 0. mm 0. mm 0.00 to mm.96 to.7 N 0. mm 0. mm 0.0 mm.9±0.4 mm 6. to 7.8 N 0. mm 0. mm.4 N max N 0. mm 0. mm 0.04 mm 4.46 to 7.6 N 0. mm 0. mm Slim Spring Plunger Z-GS-B Z-0HS-B Z-HS-B Z-0FSY-B 9 dia..±0. * dia. hole. dia. 4 dia. 4. * Stainless-steel plunger (flat, R chamfered) OF Z-GS-B Z-HS-B Z-0HS Z-0FSY-B.4 to.4 N 0.4 mm 0.0 mm.96 to.79 N 0. mm 0.0 mm 8.±0. mm.4 N max N 0. mm 0.0 mm 4.46 to 7.6 N 0. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 9

10 Short Spring Plunger Z-GD-B Z-0HD-B Z-HD-B Z-0FDY-B Z-ED-B.±0. SR * dia. hole. dia. 0 dia. 7. dia. 4. * Plated iron plunger OF Z-GD-B Z-HD-B Z-ED-B Z-0HD-B Z-0FDY-B.4 to.4 N 0.4 mm 0.0 mm.96 to.79 N 0. mm 0.0 mm 6. to 7.8 N 0. mm ±0. mm.4 N max N 0. mm 0.0 mm 4.46 to 7.6 N 0. mm Panel Mount Plunger Z-GQ-B Z-0HQ-B Z-HQ-B Z-0FQY-B Z-EQ-B Z-GQ-B * Z-GQ8-B *. *4 6. * The external dimensions of the actuator vary. 6 dia..±0. SR * dia. hole 8. dia. M mounting screw *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flats) *. Two lock nuts ( t.6 width across flats) *4. Incomplete screw part with a maximum length of mm. * * Note:. Do not use the M mounting screw and the case mounting hole at the same time, or excessive pulling force will be imposed on the switch and the case and cover may be damaged.. On the model Z-GQ-B, can be set to a value larger than that for the Z- GQ.. On the model Z-GQ8-B, operating position can be adjusted by providing a screw in the plunger section. 4. On the model Z-GQ8-B, the M hole with a depth of 0 mm is a through hole. Take precautions so that no water or screw lock agent penetrates into the hole. Z-GQ-B Z-HQ-B Z-EQ-B Z-0HQ-B Z-0FQY-B Z-GQ-B Z-GQ8-B OF.4 to.4 N.96 to.79 N 6. to 7.8 N.4 N max N 4.46 to 7.6 N.4 to.4 N.4 to.4 N 0.4 mm 0. mm 0. mm 4. mm 0. mm. mm 0.0 mm. mm 0.0 mm. mm 0. mm. mm 0.0 mm. mm 0. mm. mm. mm. mm 0.0 mm.8± 8.8±.± mm Panel Mount Roller Plunger Z-GQ-B Z-EQ-B Z-HQ-B Z-0FQY-B.±0..7 dia. 4.8 * *. 6. * 6 dia dia. hole M mounting screw *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. OF Z-GQ-B Z-HQ-B Z-EQ-B Z-0FQY-B.4 to.4 N 0.4 mm.8 mm 0.0 mm.96 to.79 N 0. mm.8 mm 0.0 mm.4±. mm 6. to 7.8 N.8 mm 0. mm 4.46 to 7.6 N mm. mm 0. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 0

11 Panel Mount Cross Roller Plunger Z-GQ-B Z-EQ-B.±0..7 dia. 4.8 * Z-HQ-B Z-GQ-B Z-HQ-B OF.4 to.4 N.96 to.79 N * 0.4 mm 0. mm dia. hole M.8 mm.8 mm mounting screw 0.0 mm 0.0 mm * 6. 6 dia..4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. OF Z-EQ-B 6. to 7.8 N.8 mm 0. mm.4±. mm Leaf Spring Z-GL-B 49.6±0.8 t = 0.* dia. hole 4.8 * Stainless-steel spring lever.9 OT *min..8 N 0.4 N. mm max. 0.6 mm 7.4± * When operating, be sure not to exceed. Roller Leaf Spring Z-GL-B 46 ±0.8 t = 0. * 9. dia. 4 (plastic toller) dia. hole.9 * Stainless-steel spring lever OT *min..8 N 0.4 N. mm max..8 mm 8.6± * When operating, be sure not to exceed. Short Hinge Lever Z-GW-B 8.R dia. hole max. 7 N 0.7 N mm mm 4.8 mm 9± Hinge Lever Z-GW-B Z-GW-B Z-HW-B Z-0FWY-B Z-GW-B (Lever Length: 6R)* 6.R dia. hole * The external dimensions of the actuator vary. OF Z-GW-B Z-HW-B Z-GW-B Z-0FWY-B Z-GW-B 0.69 N max. 0.4 N.6 mm.7 mm 0.66 N max. 0.4 N.6 mm 0.6 mm.47 to.96 N 0.9 N.6 mm.7 mm 0.88 N max. 0.4 N.6 mm.4 mm 0.78 N max. 0. N 4.8 mm. mm max. 8. mm 7.4 mm 8. mm 9.8 mm 7. mm 9± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

12 Low-force Hinge Lever Z-GW4-B 6.R dia. hole 74 mn 4. mn 0 mm.6 mm.7 mm 9±0.8mm Z-HW4-B 0R R 0 t = 0.8 * dia. hole 7.4 ± mn 4.90 mn 9.8 mm 0 mm mm 9.8± Low-force Wire Hinge Lever Z-HW-B Z-HW78-B (Lever Length: 0R) * * The external dimensions of the actuator vary. Note: AC electrical ratings: 0 A, /0 V. max dia. hole 6.R * Stainless-steel wire lever Z-HW-B 8.8 mn 4.90 mn 8. mm.6 mm 0.6 mm 9± mm Z-HW78-B mn.94 mn 0 mm 6 mm mm 0± mm Short Hinge Roller Lever Z-GW-B Z-0HW-B Z-HW-B Z-0FWY-B Z-EW-B Z-GW-B * Z-HW-B * Z-0FWY-B * 6.6R dia. 4 (plastic roller) max. * The external dimensions of the actuator vary. (Lever Length: 48.R) dia. hole Z-GW-B Z-HW-B Z-EW-B Z-0HW-B Z-0FWY-B Z-GW-B Z-HW-B Z-0FWY-B 7 N 0.4 N.4 mm 0. mm. mm 0.±0.4 mm.47 N 0.4 N.4 mm 0.4 mm.94 N 0.4 N.4 mm. mm. mm 0.±0.4 mm 7 N 0.7 N.4 mm 0. mm. mm 0.±0.4 mm.4 N 0.4 N.4 mm mm 4.8 mm 0.±0.4 mm 0.98 N 0. N 4 mm.0 mm 6. mm 0.± 0.84 N 0. N 4 mm 0.6 mm.7 N 0. N 4 mm mm 7.4 mm 0.± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

13 Short Hinge Cross Roller Lever Z-GW49-B Z-GW4-B (Lever Length: 48.7R) * 7.R 9. dia. 4 (plastic roller) * The external dimensions of the actuator vary dia. hole max. Z-GW49-B.67 N 0.4 N.4 mm 0. mm. mm ±0.4 mm Z-GW4-B 0.98 N 0. N 4 mm mm 7. mm ± Hinge Roller Lever Z-GW-B 0R t = * 0 dia. 4 R (plastic roller) dia. hole max N 0. N 4 mm 47. mm 4.± Unidirectional Short Hinge Roller Lever Z-GW77-B 4. max. Operating direction.9r R dia. hole 9. dia. 4 (plastic roller) max..67 N 0.4 N.4 mm 0. mm 4.6 mm 4.± Reverse Hinge Lever ** Z-GM-B 8.6 6R dia. hole max..67 N 0.7 N.6 mm 0.89 mm.8 mm 9± Reverse Short Hinge Roller Lever ** Z-GM-B Z-0FMY-B R dia. hole 9. dia. 4 (plastic roller) max. Z-GM-B.8 N.67 N mm.8 mm 9.4±0.4 mm Z-0FMY-B 6.7 N.67 N mm 0.6mm mm 9.4±0.4 mm Reverse Hinge Roller Lever ** Z-GM-B R t = * 9. dia. 4 (plastic roller) dia. hole max.. N 0. N 4 mm 0.64 mm mm 0.± ** The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

14 Basic Models (Drip-proof) without Terminal Protective Cover Terminals (Molded Terminals: Refer to page.) Without Terminal Protective Cover 0 0 COM NO NC Three, M4. Terminal screws (with toothed washer) Note: With reverse action models (Z-GM), the positions of NO and NC terminals are reversed. Dimensions and Operating Characteristics The above illustration is for model without terminal protective cover. Pin Plunger Z-G-B Z-0H-B 6SR *.± dia. hole.9 dia..9 * Stainless-steel plunger OF Z-G-B Z-0H-B.4 to 4. N.4 N max N. mm. mm 0. mm 0. mm 0.06 mm 0.06 mm.9±0.4 mm Short Spring Plunger Z-GD-B Z-0HD-B SR *.± dia. hole dia. 7. dia..9 * Stainless-steel plunger Z-GD-B Z-0HD-B.0 N.6 N 0.78 N.8 mm.9 mm 0.06 mm 0.06 mm ±0. mm Spring Plunger Z-GK-B SR *.±0. 7 dia. 7. dia dia. hole.9 * Stainless-steel plunger.0 N. mm 0.06 mm 8.±0. mm Z-GK-B SR *. ±0. 7 dia. 8. dia dia. hole. * Stainless-steel plunger.0 N.4 mm. mm 0.06 mm 7.8±. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 4

15 Panel Mount Plunger Z-GQ-B. 6. *4 6 dia..±0. SR * dia. hole 8. dia. *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flats) *. Two lock nuts ( t.6 width across flats) *4. Incomplete screw part with a maximum length of mm. M Mounting screw * *.0 N.8 mm. mm 0.06 mm.8± Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Roller Plunger Z-GQ-B.±0..7 dia. 4.8 *. * 6. 6 dia dia. hole *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. * M mounting screw.0 N.8 mm.8 mm 0.06 mm.4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Cross Roller Plunger Z-GQ-B.±0..7 dia. 4.8 *. 6. * 6 dia dia. hole *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. * M mounting screw.0 N.8 mm.8 mm 0.06 mm.4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Leaf Spring Z-GL-B 49.6±0.8 t = 0. * dia. hole * Stainless-steel spring lever OT *min..96 N 0.4 N. mm max. 0.6 mm 7.± * When operating, be sure not to exceed. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

16 Roller Leaf Spring Z-GL-B 46 ±0.8 t = 0.* 9. dia. 4 (plastic roller) dia. hole 7.4 ±0..9 OT *min..96 N 0.4 N. mm max..8 mm 8.6± * When operating, be sure not to exceed. Short Hinge Lever Z-GW-B 8.R t = * dia. hole dia max..86 N 0.7 N mm mm mm 9± Long Hinge Lever Z-GW44-B 00R dia. hole max N 0.4 N.6 mm. mm mm 9±. mm Hinge Lever Z-GW-B 6.R t = * dia. hole 7.4 ±0. max N 0.4 N.6 mm mm 8. mm 9± Short Hinge Roller Lever Z-GW-B Z-0HW-B 6.6R 9. dia. 4 (plastic roller) dia. hole max. Z-GW-B.96 N 0.4 N.4 mm.9 mm 0.±0.4 mm Z-0HW-B.96 N 0.7 N.4 mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 6

17 Hinge Roller Lever Z-GW-B 48.R 9. dia. 4 (plastic roller) dia. hole max..7 N 0. N 4 mm 6. mm 0.± Unidirectional Short Hinge Roller Lever Z-GW77-B 4. max. Operating direction.9r R dia. hole 9. dia. 4 (plastic roller) 7.4 ±0. max..77 N 0.49 N.4 mm 4.6 mm 4.± Reverse Hinge Lever * Z-GM-B 8.6 6R dia. hole 7.4 ±0. max..96 N 0.7 N.6 mm 0.89 mm.8 mm 9± Reverse Short Hinge Roller Lever * Z-GM-B dia. 4 (plastic roller) 8.R dia. hole max..69 N.67 N mm.8mm 9.4±0.4mm Reverse Hinge Roller Lever * Z-GM-B R 9. dia. 4 (plastic roller) dia. hole 7.4 ±0. max..6 N 0. N 4 mm 0.64 mm mm 0.± * The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 7

18 Flexible Rod (Coil Spring) Z-GNJ-B 6. dia.. dia. * Nylon rod 8 0 Operating range * (.) 4.4 Rubber cap dia. (.6) 6..± dia. hole 0.49 N (0 mm) TT max. 40 mm *. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *. Use only the area within the top 0 mm of the rod as the operating part. (Do not use the area that falls within 80 mm from the mounting hole as the operating part. Using this area may cause damage to the nylon rod. Flexible Rod (Steel Wire) Z-HNJS-B * 0 Operating range * -dia. stainless steel wire * 00±0.4 (0.) () Four, M set screws with hexagonal holes Rubber cap dia. (.8) 6..± dia. hole 0. N ( mm) *. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *. Use only the area within the top 0 mm of the rod as the operating part. (Do not use the area that falls within 00 mm from the mounting hole as the operating part. Using this area may cause damage to the steel wire.) *. The steel wire can be replaced if damaged. (Model: Lever for HNJS) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 8

19 Basic Models (Drip-proof) with Terminal Protective Cover Dimensions and Operating Characteristics Pin Plunger Z-GA-BV 6SR *.±0..9 dia dia. hole (8.8) 4.7 () 7.4 ±0. * Stainless-steel plunger.4 to 4. N. mm 0. mm 0.06 mm.9±0.4 mm Z-GKA-BV 7 dia. SR *. ±0. 8. dia dia. hole (8.8) 4.7 () 7.4 ±0. * Stainless-steel plunger.0 N.4 mm. mm 0.06 mm 7.8±. mm Panel Mount Plunger Z-GQA-BV SR *.± dia dia. hole (8.8) 8. dia. M P = () *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flat) *. Two lock nuts ( t.6 width across flats) * *.0 N.8 mm. mm 0.06 mm.8± Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Roller Plunger Z-GQA-BV.± dia..7 dia. 4.8 * * M P =.0 N.8 mm.8 mm 0.06 mm.4±. mm dia. hole (8.8) () *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Cross-roller Plunger Z-GQA-BV. ± dia..7 dia. 4.8 * * M P =.0 N.8 mm.8mm 0.06 mm.4±. mm dia. hole (8.8) () 7.4 ±0. *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 9

20 Long Hinge Lever Z-GW44A-BV 00R dia. hole (8.8) () max N 0.4 N.6 mm. mm mm 9±. mm Hinge Lever Z-GWA-BV 6.R dia. hole (8.8).9 () max N 0.4 N.6 mm mm 8. mm 9± Short Hinge Roller Lever Z-GWA-BV 6.6R 9. dia. 4 (plastic roller) dia. hole (8.8) ±0. () max..96 N 0.4 N.4 mm.9 mm 0.±0.4 mm Hinge Roller Lever Z-GWA-BV 48.R 9. dia. 4 (plastic roller) dia. hole (8.8).9 () max..7 N 0. N 4 mm 6. mm 0.± Unidirectional Short Hinge Roller Lever Z-GW77A-BV Operating direction 9. dia. 4 (plastic roller).9r 4. max dia dia. hole.8.r (8.8).9 () max..77 N 0.49 N.4 mm 4.6 mm 4.± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 0

21 Basic Models (Drop-proof) with Modeled terminals Molded Terminals L/R Type (The following illustration is the R type.) D Type a c a b 8 Lead Wire Specifications Specifications Lead wire VSF (single-core, vinyl cord) VCT (vinyl-insulated cable) Size (mm) Lead wire Nominal cross sectional area (mm). a b c VSF 4 VCT 9 0 Finished outer diameter (mm) Approx.. dia. Three-core: approx. 0. dia. Note:. No models with molded terminals are approved by UL, CSA, or EN.. Molded terminals are not available on all models. Contact your OMRON representative for applicable products. b Connection to terminal Black:COM White:NO Red: NC Length (m), c Size (mm) Lead wire a b c VSF 4 VCT 9 6 Maintained-contact Models Dimensions and Operating Characteristics Pin Plunger Z-ER. ±0. 4.± dia. hole Reset button *. dia..sr * Reset position 7. min. 6.4 dia. Reset free position 9. max. Plunger Reset Button.96 to.0 N 0.4 mm 0. mm.9±0.4 mm COM NO NC *. Stainless steel plunger *. Plastic plunger 0. to.79 N 0.4 mm Slim Spring Plunger Z-ESR 9 dia.. ±0. * 4. ± dia. hole dia. 4 dia. Reset position 7. min. 6.4 dia. Reset free Reset button * position 9. max. *. Stainless steel plunger (tip only, flat, R bevel). *. Plastic plunger Plunger Reset Button.6 N 0.4 mm 8.±0. mm.79 N 0.4 mm Hinge Lever Z-EWR 6.R 4.9 Lever Tip ± dia. hole 6.4 Reset position 7. min. 6.4 dia. Reset button * *. Stainless steel lever *. Plastic plunger Reset free position 9. max. max. Reset Button 0.4 N.6 mm 8. mm 9±.94 N 0.4 mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

22 Accessories (Order Separately) A Terminal Protective Cover, Actuators, and a Separator are available. Drip-proof Terminal Cover (Order Separately) The Drip-proof Terminal Protective Cover is provided for maintenance for Z-@A-BV Switches. Ordering Information Dimensions (Unit: mm) Name Model Drip-proof Terminal Protective Cover AP-DV Mounting bracket Terminal Covers (Sold Separately) The Terminal Covers can be attached to Z, A, X, and DZ Switches. The Terminal Cover is secured with mounting screws and protects the casing and terminal wires from dust, vibration, or fingers, thus preventing terminal short-circuiting, ground faults, wire disconnection or improper connection, and electric shock accidents. Terminal Covers made of phenol resin have five or six thin wall sections. These sections can be torn open for providing holes for lead cables at desired points. A terminal cover can t be used in the case of using an actuator sold separately. Operation Information Application Soldering terminal use Screw terminal use Material Mounting direction Model Remarks Phenol resin Side mounting AP-A AP-B Metal press mold Side mounting AP-A AP-B Used for AP-A and AP-B Vinyl chloride Side mounting AP-Z Note: Use a Terminal Cover for screw terminals fir DZ-series Switches with soldering terminals. Separator (Sold Separately) Use a Separator when it is difficult to provide a sufficient insulation distance or when using the Switch near metal parts or copper wires. Operation Information Model SEPARATOR FOR Z

23 Dimensions (Unit: mm) Terminal Covers AP-A Soldering Terminal Use (Phenol Resin) R AP-B Screw Terminal Use (Phenol Resin) R Note: The Cover has five thin, easy-to-separate portions for easy lead wire connections. Note: The Cover has six thin, easy-to-separate portions for easy lead wire connections. AP-A Soldering Terminal Use (Metal Press Mold) R AP-B Screw Terminal Use (Metal Press Mold) R Note: The Cover has five holes for easy lead wire connections. AP-Z Soldering or Screw Terminal Use (Vinyl Chloride) Pressure plate (t steel) 4 Two, 4. dia. Note: The Cover has six holes for easy lead wire connections..8.4 Cable Pull-out Dimension 7 A-A' cross-section B-B' cross-section Nut M 0 Phillips screw (with plane washer and nut) Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. (± for the AP-Z) A B A' B' dia. 6 dia. Note: A 6-dia. or 8-dia. cable can be used by cutting the cable pull-out hole to the size of the cable to be used. Separator Two, 4. dia...4±0. ±0. t = 0. 7±0. Note:. Each dimension has a tolerance of ±0.4 mm unless otherwise specified.. The material is EAVTC (Epoxide Alkyd Varnished Tetron Cloth) and its heat-resisting temperature is 0 C.

24 Actuators (Sold Separately) A Switch can be actuated by a cam or an appropriate object, in which case, use one of the following Actuators according to the application. Ordering Information Actuator Application Common to Z and X models Hinge lever XAA- Hinge roller lever Panel mount plunger Panel mount roller plunger Short Medium Long ZAA- ZAQ- ZAQ- ZAQ- ZAQ- Dimensions (Unit: mm) and Operating Characteristics Hinge Lever XAA- XAA- XAA Two, M4 Two, M4 0 7 * 60R Note: These Actuators are not provided with Switches. * Stainless steel Model Operating characteristics Operating force Release force Overtravel Movement Differential Free Position max. Operating Position Z-G-B 4.90 N.67 N.7 mm. mm.9± 8.9± X-0G-B 4.90 N.67 N.7 mm. mm Note: This Actuator can be used with the Z-G(-B) and X- 0G(-B). When mounting the Switch, set the overtravel to between % and 00%, taking into consideration the operating body and the distance between the Actuator and the dog. Hinge Roller Lever ZAA- Two, M4 Two, M * R. 9. dia. 4.8 * max. Z-G-B 4.90 N.67 N.7 mm. mm 44.± 40.4± X-0G-B 4.90 N.67 N.7 mm. mm Note: This Actuator can be used with the Z-G(- B) and ZX-0G(-B). When mounting the Switch, set the overtravel to between % and 00%, taking into consideration the operating body and the distance between the Actuator and the dog. *. Stainless steel roller *. Stainless steel Short Panel Mount Plunger ZAQ * *.. SR *.4 4. dia. * dia. M mounting screw t 4 width across flats t.6 width across flats Two, M4 nuts Two, M4 screws 0.7 *. Stainless-steel pin plunger *. Bronze frame *. Incomplete screw section part with a maximum of mm ZAQ- Z-E-B X-0G-B 8.4 N 4.8 mm 0. mm 7.8± mm.9 N mm 4. mm 0. mm Note:. This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(-B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 4

25 Medium Panel Mount Plunger ZAQ-. SR *.6 * 4. dia dia. M mounting screw t 4 width across flats t.6 width across flats ZAQ- Z-E-B X-0G-B 8.4 N 4.8 mm 0. mm.± mm.9 N mm 4. mm 0. mm Two, M4 screws Note: This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(- B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. * Two, M4 nuts *. Stainless-steel pin plunger *. Copper alloy frame *. Incomplete screw section part with a maximum of mm Long Panel Mount Plunger ZAQ-. SR * * 4. dia dia. M mounting screw t 4 width across flats t.6 width across flats Two, M4 screws ZAQ- Z-E-B X-0G-B 8.4 N 0.6 mm 0. mm.9 N mm 0.4 mm 0. mm 69.± mm Note: This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(- B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. *..4 Two, M4 nuts 0.7 *. Stainless-steel pin plunger *. Copper alloy frame *. Incomplete screw section part with a maximum of mm Panel Mount Roller Plunger ZAQ-.6 * 0.7 * 48.±0. 4. dia..4± dia. * 4.8 Two hex nuts -mm thickness, 9 mm between opposing edges With groove for roller penetration M mounting screw ZAQ- Z-E-B DZ-0G-B 8.4 N mm.8 mm 0. mm. N mm mm 0.46 mm 7±.4±. mm.9 Note: This Actuator (roller plunger) can be used with standard pin plungers (Z-G(-B), Z-E(-B), and DZ-0G-A(-B)). It cannot be used with X models. Two, M4 Spring washer 0.7 screws *. Stainless-steel pin plunger *. Steel frame *. Incomplete screw section part with a maximum of mm Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified.

26 Safety Precautions Z Refer to Safety Precautions for All Basic Switches. Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is applied to any part of the Switch for s or more. Operation Make sure that the switching frequency or speed is within the specified range..if the switching speed is extremely slow, the contact may not be switched smoothly, which may result in a contact failure or contact welding..if the switching speed is extremely fast, switching shock may damage the Switch soon. If the switching frequency is too high, the contact may not catch up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. In order to determine the life of a Switch model to be applied to a particular use, it is best to conduct an appropriate durability test on some samples of the model under actual conditions. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 00% of the rated OT. Mounting Location Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Incorrect Precautions for Safe Use Precautions for Correct Use Incorrect Terminal box Terminal box Correct Correct Do not use the switch in locations subject to hot water (greater than 60 C) or in water vapor. Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Incorrect Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. Incorrect Correct (preventing malfunctions) Correct Separate the installation location from heat sources. Subjecting the switch to continuous vibration or shock may result in contact failure or faulty operation due to abrasion powder and in reduced durability. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (HS, SO), ammonia gas (NH), nitric acid gas (HNO), or chlorine gas (Cl). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Mounting Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or burning may occur. Selecting Models We recommend using Drip-proof Models (protection equivalent to IP6) in locations subject to floating dirt and dust. Other models do not have a protective structure. Wiring Use wire sizes that are suitable to the applied voltage and carried current. If you use a soldering iron to solder the wires, do not allow the tip of the soldering iron to exceed 80 C. If a Switch is used with insufficient soldering, abnormal heat and burning may occur. Solder for no more than s at 0 C and for no more than s at 80 C. If heat is applied for too long, the case may melt, the lead wire coverings may be scorched, and other characteristics of the Switch may deteriorate. Tightening The suitable tightening torque for screw terminals is given below. Screw terminals except for those on Split-contact Models (Z-0FY- B): 0.78 to.8 N m Screw terminals on Split-contact Models (Z-0FY-B): 0.49 to.8 N m Operation Make sure that the switching speed and frequency are is within the specified ranges.. If the switching speed is extremely slow, the contacts may not be switched smoothly, which may result in a contact failure or contact welding. 6

27 . If the switching speed is extremely fast, switching shock may damage the Switch prematurely. If the switching frequency is too high, the contacts may not be able to keep up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. Always conduct appropriate durability tests under actual conditions before using a Switch. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 00% of the rated OT. Panel Mount Switch (Z-@Q@, Z-0@Q@) When mounting the panel mount plunger model with screws on a side surface, be careful of the dog angle and operation speed. Excessive dog angle or operation speed may damage the Switch. When using the panel mount plunger model mounted with screws on a side surface, be careful not to apply a large shock. Applying a shock exceeding,000 m/s may damage the Switch. When using the panel mount plunger model mounted with screws on a side surface, remove the hexagonal nuts from the actuator. High-sensitivity Switch (Z-H)/ Extra-high-sensitivity Switch (Z-H) When using the Switch in a DC circuit, be sure to provide an arc suppressor as well because the small contact gap of the Switch may result in contact troubles. In an application where a high repeat accuracy is required, limit the current that flows through the Switch to within 0. A. Also, use a relay to control a high-capacity load if the Switch is connected to such a load. (In this case, the exciting current of the relay coil is the load of the Switch.) Do not apply a force of 9.6 N or higher to the pin plunger. Exercise care that the environment conditions such as temperature and humidity do not change abruptly. Micro Load Applicable Range Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60). The equation, λ 60 = /operations indicates that the estimated malfunction rate is less than /,000,000 operations with a reliability level of 60%. DC voltage (V) 0 4 Unusable range Minimum applicable load 0 0. mw 0.6 ma ma Operating range for micro load models Z-0H 0 00,000 Z-0H 800 mw 6 ma Operating range for general load models Z-H, H Z-G Z-E Z-0FY Z-ER 00 ma 60 ma Current (ma) Z-@, Z-0FY ma at VDC 60 ma at VDC Models with Drip-proof Terminal Cover (Z-@A-BV) Wiring To attach the Protective Cover to the case, hold the cover in almost parallel to the case and then push it to the case. If the cover is pushed diagonally, the rubber packing may slip off, degrading the sealability of the Switch. Terminal with toothed washer Rubber packing Use round solderless terminals having the 4. dia. following dimensions to connect leads to the terminals. Tighten the screws of terminals to 8 a torque of 0.78 to.8 N m. Use the terminal shown below. 0 max. A cable 8. to 0. mm in diameter can be applicable to the sealing rubber of the lead outlet of the Switch. A two-core or three-core VCT cable having a cross-sectional area of. mm is especially suitable for this. Use M4 small screws with spring toothed washer are used as the terminal screws. Drip-proof Switch (Z-@) The Switch is not perfectly oil-tight; so do not dip it in oil or water. The rubber boots are made from weather-resistive chloroprene rubber. Do not use Basic Switches in places with radical changes in temperature. Rubber boots and rubber caps will tend to harden at lower ambient temperatures. If an Actuator is used in a pressed state for an extended period of time at low temperatures, it may return slowly or it may not return at all. OMRON can provide special Actuators for use at low temperature with rubber boots or rubber caps made of silicon rubber, which has superior resistance to cold. Ask your OMRON representative for details. Split-contact Switch (Z-0F@Y) The applicable current varies depending on how the contacts are used. If the Switch is connected in series, the Switch can endure a current to times higher than the current that can be applied in parallel connection. Flexible Rod Switch (Z-@NJ@, Drip-proof) When the rod is fully swung, the Switch may operate when the lever returns, causing chattering. Use a circuit that compensates for chattering wherever possible. Do not switch the rod to the fullest extent when the Switch is to break a power circuit because such a practice may cause metal deposition to occur between the mating contacts of the Switch. Other Precautions Do not apply excessive force with a screwdriver or other tool when attaching or removing the Protective Cover. Doing so may deform the Switch. Screwdriver The Drip-proof Terminal Protective Cover can be sued only with Switches with model numbers ending in -BV. Only the Terminal Protective Cover is available for maintenance. 7

OMRON Z LIMIT SWITCH

OMRON Z LIMIT SWITCH Issued April 00 DATA SHEET OMRON LIMIT SWITCH Based on OMRON Datasheet General-purpose Basic Switch CSM DS_E Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity

More information

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety General-purpose Basic Switch Z Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in contact form for

More information

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety General-purpose Basic Switch Z CSM_Z_DS_E Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in contact

More information

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety General-purpose Basic Switch Z CSM_Z_DS_E_4_ Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in

More information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000

More information

Direct Current Switch with Built-in Magnetic Blowout

Direct Current Switch with Built-in Magnetic Blowout General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Same

More information

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information List of s Terminal Covers (Sold Separately) Common to Z, A, X, and DZ s The Terminal Cover is secured with mounting s and protects the casing and

More information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch D2VW Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to

More information

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31 Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision

More information

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information List of s Terminal Covers (Sold Separately) Common to Z, A, X, and DZ s The Terminal Cover is secured with mounting s and protects the casing and

More information

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW- Sealed Subminiature Basic Switch Sealed Subminiature Basic Switch Conforming to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Small Limit Switch D4V

Small Limit Switch D4V Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch SS Subminiature Basic Switch Offers Long Life of 30,000,000 Operations A design that combines simplicity and stability by the use of two split springs ensures a long service life

More information

Low-torque Basic Switch

Low-torque Basic Switch Low-torque Basic Switch Highly Reliable Rotary-action Switch for Low Torque Operation (0.5 m N m {5.1 gf cm}) 0.5-A rated model employs crossbar gold-alloy contacts for excellent contact reliability in

More information

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information Sealed Ultra Subminiature Basic Switch Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action. The case dimensions are 78% of conventional models, contributing

More information

Pre-wired Models D4C- (1) (2) (3) (4)

Pre-wired Models D4C-  (1) (2) (3) (4) Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 03 Ph: +91 44 4353 Fax: 044 4353 E-mail: info@intechchennai.com Website: www.intechchennai.com Enclosed Switch D4C CSM_D4C_DS_E_10_1

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Technical Guide for Basic Switches

Technical Guide for Basic Switches Terms for Basic Switches Technical Guide for Basic Switches General Terms (1) General Terms Basic Switch: A small-size switch with a very small contact gap and snap-action mechanism and with a contact

More information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9. Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation

More information

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Technical Explanation for Basic Switches

Technical Explanation for Basic Switches CSM_MicroSwitch_TG_E_3_2 Introduction What Is a Basic Switch? A Basic Switch is a small switch with a very small contact gap and snap-action mechanism and with a contact structure that switches for a specified

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information Sealed Ultra Subminiature Basic Switch Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action. The case dimensions are 78% of conventional, contributing to

More information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_4_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth

More information

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000 R Miniature Enclosed Limit Switch Economical, General-Purpose, Enclosed Switch H High precision and long life (,000,000 mechanical operations) H Gasket diaphragm seal provides high environmental resistance

More information

AM1 (NZ BASIC) SWITCHES

AM1 (NZ BASIC) SWITCHES HIGH CONTACT CAPACITY, PRECISE OPERATION AM1 (NZ BASIC) SWITCHES 24.1 FEATURES 15 A High current switching capacity and high precision Wide allowance of operating speed Versatile variety of actuators UL/CSA

More information

Manual Reset Limit Switch

Manual Reset Limit Switch Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double

More information

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator Miniature Limit Switch CSM DS_E_3_3 Many Models Including Roller Lever Switches are Only -mm Thick with Connector New center roller lever models that enable ganged mounting of up to 6 Switches. Cable connectors

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Model Number Structure

Model Number Structure Long-life Two-circuit Limit Switch WLM@ New Long-life Limit Switches Added to the Wide Variety of WL Models Improved resistance to abrasion and smoother movement in the head section means that a mechanical

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Compact, high-performance limit switch with superior environmental resistance. Broad lineup covers from die casting cases to economical plastic cases.

More information

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening SPATTER-GUARDED SWITCHES Model LS Effective countermeasures against the adhesion of spatter. UL/CSA/GB(CCC marking)-approved. (excluding some models) ORDER GUIDE Actuator Name Roller lever type Shape Max.

More information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_6_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend Safety-door Hinge Switch Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO and 3NC contact forms

More information

TURQUOISE STROKE SWITCHES

TURQUOISE STROKE SWITCHES ULTRA-LONG STROKE, HIGH CONTACT RELIABILITY SEALED SWITCHES (SAME SIZE AS J TYPE) ASQ1 TURQUOISE STROKE SWITCHES 9.6 13.3 FEATURES (mm) http://panasonic-denko.co.jp/ ac/e/service/environment 1. Same size

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Turquoise Stroke Switches

Turquoise Stroke Switches Long Stroke and Sliding Contact Construction Sealed Switches Turquoise Stroke Switches 13.3 10.1 (Unit: mm) RoHS compliant FEATURES For pin plunger, it maintains a long stroke OT (Over Travel) with over

More information

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action The case dimensions are 78% of conventional models, contributing to down-sizing of mechanical modules.

More information

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards. Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN (TÜV) standards. (positive opening mechanism isindicatedonthe switch) H Wide standard operating

More information

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P New Product Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Direct opening mechanism to open the circuit when the contact

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch D4F CSM_D4F_DS_E_5_2 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The

More information

Turquoise Stroke Mini Switches

Turquoise Stroke Mini Switches Long Stroke, Sliding Contact Construction Sealed Switches Turquoise Stroke Mini Switches 5.3 (Unit: mm) 7.85 5.3 Terminal 13.55 Wire leads RoHS compliant FEATURES Miniaturization achieved with changing

More information

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening Safety Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking H Contacts opened by positive opening mechanism (NC contacts only) H Double insulation makes ground terminal

More information

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch Long stroke seal switch with high reliability and high insulation performance Double reliability by twin contacts (=Clipping contact). Foreign materials are cleaned out by the sliding

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models. Highly reliable iniature Basic Switch in spite of its Ultra-low Load action Twin crossbar contact employed for exceptionally high contact reliability. Unique internal mechanism that ensures high contact

More information

TURQUOISE STROKE SWITCHES

TURQUOISE STROKE SWITCHES Long Stroke and Sliding Contact Construction Sealed Switches TURQUOISE STROKE SWITCHES 13.3 10.1 (Unit: ) RoHS compliant FEATURES For pin plunger type, it maintains a long stroke OT (Over Travel) with

More information

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~ 6 BZ, BA, BE Series Specifications Standard Basic Switches FEATURES These Switches are Used Extensively and Have Earned the High Respect of Our Customers. Standard basic switches (BZ, BA, BE Series) are

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

Miniature Limit Switches

Miniature Limit Switches (Horizontal) Plastic od 49.17.1* oller Lever 49.1.01.03 Miniature Limit witches 49 ealed oller Plunger 49 eries Miniature Limit witches Model election...1 Model Number tructure... Technical Data...3 pecification...4

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information

Limit Switches Technical Information

Limit Switches Technical Information Limit Switches Technical Information Safety Precautions For the individual precautions for each Switch, refer to the Precautions section of each Switch.!WARNING Do not touch the charged switch terminals

More information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts

More information

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure General-purpose Limit Switch HL-5000 Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure provides

More information

Lighted Pushbutton Switch

Lighted Pushbutton Switch Lighted Pushbutton Switch General Purpose and Micro-Voltage/Current Load Switch Requires only 22 mm mounting depth All LEDs, lamps, legends and pushbutton units replaceable without tools Oil-resistant

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse. Switch A22E Install in 22-dia. or 25-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating errors. Easy mounting and removal of

More information

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch Two-circuit Limit Switch/Long-life Two-circuit Limit Switch WL-N/WLM-N Select the Best Two-circuit Switch for the Operating Environment and Application from a Wide Range of Models A wide selection of models

More information

Limit Switches with Positive Opening Mechanism

Limit Switches with Positive Opening Mechanism Limit Switches with Positive Opening Mechanism LJA Series Positive opening mechanism Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

Robust General-Purpose Limit Switch WL

Robust General-Purpose Limit Switch WL Robust General-Purpose Limit Switch WL Wide Selection of Two-Circuit Double-Break Limit Switches Rugged diecast housing High mechanical strength Oiltight, waterproof, dustproof construction Overtravel

More information

Multiple Limit Switch

Multiple Limit Switch Multiple Limit Switch CSM DS_E_1_1 A New Monoblock Multiple Limit Switch Incorporating a ead Box with a Tough ead and Ensuring igh Sealing Performance and a Mechanical Durability of 5,000,000 Operations

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

High Operating Precision Basic Switches with High Capacity and Long Life

High Operating Precision Basic Switches with High Capacity and Long Life High Operating Precision Basic Switches with High Capacity and Long Life AM1 (NZ) SWITCHES 24.1 49.2 17.5 FEATURES 10 A Current switching capacity High precision and long life Versatile variety of actuators

More information

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety-door Switch D4NS. Model Number Structure. Model Number Legend Safety-door Switch D4NS Multi-contact, Labor-saving, Environmentfriendly, Next-generation Safety-door Switch Lineup includes MBB models and three contact models with 2NC/1NC and 3NC contact forms in addition

More information

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros Waterproof Vertical Type Limit Switches Model VCL-mm 2 sets of SPDT built-in switches enable use as a 2-point detection switch or multi-circuit control switch. On the 2-point detection (center-neutral)

More information

QL (AZ4) Limit Switches

QL (AZ4) Limit Switches SUMINITURE SIZE LIMIT SWITCHES QL (Z4) Limit Switches High precision micro limit switches with excellent environmental protection. Quickly upgraded to limit switches with lamps by mounting an LED lamp

More information

SL (AZ3) Micro Limit Switches

SL (AZ3) Micro Limit Switches SUBMINIATURE SIZE LIMIT SWITCHES SL (AZ3) Micro Limit Switches Quickly upgraded to limit switches with lamps by mounting an LED lamp socket. Rubber cover type (roller ) Compliance with RoHS Directive FEATURES

More information

SL1Series. Compact Horizontal Limit Switches

SL1Series. Compact Horizontal Limit Switches Compact Horizontal Limit Switches SL1Series Mechanical life of 0 million operations. Robust long-life and maintenance-free compact horizontal-type limit switches with IP67 seal. Mechanical life exceeds

More information

Sliding contact construction Switches for Low-level Loads

Sliding contact construction Switches for Low-level Loads Sliding contact construction Switches for Low-level Loads AEQ (EQ) Switches 13.3 10.1 (Unit: mm) RoHS compliant FEATURES Handles low level load: 100 μa at 3 VDC to 100 ma 30 VDC Long stroke: For pin plunger

More information

Miniature Pre-Leaded Vertical Enclosed Switches

Miniature Pre-Leaded Vertical Enclosed Switches Miniature Pre-Leaded Vertical Enclosed Switches 14CE Series Miniature enclosed switches with outstanding harsh environment resistance, ideal for compact machinery and equipment. Easy mounting by tightening

More information

1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES

1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES 1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES With on-site mechanical life 3 times that of conventional models, improved reliability drastically reduces minor line interruptions.

More information

TURQUOISE SWITCHES J TYPE (ABJ)

TURQUOISE SWITCHES J TYPE (ABJ) HIGH ENVIRONMENTAL RESISTANCE TURQUOISE SWITCHES J TYPE (ABJ) Dust protected type Immersion protected type (wire leads bottom type) (Mounting hole 2.3mm.091inch type) (Mounting hole 2.3mm.091inch type)

More information

A165E CSM_A165E_DS_E_11_2

A165E CSM_A165E_DS_E_11_2 Emergency Stop Switch (16-dia.) CSM DS_E_11_2 Separate Construction with Minimal Depth Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN 6947-5-5. Includes

More information

D4GS-N CSM_D4GS-N_DS_E_7_2

D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

TURQUOISE SWITCHES J TYPE (ABJ)

TURQUOISE SWITCHES J TYPE (ABJ) HIGH ENVIRONMENTAL RESISTANCE ABJ1,2,3,4,5 TURQUOISE SWITCHES J TYPE (ABJ) Dust protected type Immersion protected type (wire leads bottom type) (Mounting hole 2.3mm.091inch type) (Mounting hole 2.3mm.091inch

More information

Lighted PushButton Switch

Lighted PushButton Switch Lighted PushButton Switch Cylindrical 8mm dia. Subminiature Series Featuring Short Mounting Depth Round, square and rectangular LED pushbutton units. types also available. Requires only 18mm mounting depth.

More information

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Safety-door Hinge Switch CSM DS_E_4_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Note: Contact your sales representative for details on models

More information

D4NH CSM_D4NH_DS_E_7_1

D4NH CSM_D4NH_DS_E_7_1 Safety-door Hinge Switch D4NH CSM_D4NH_DS_E_7_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO

More information

BZSeries. Basic Switches

BZSeries. Basic Switches Basic Switches BZSeries These switches have been used extensively and have earned the high respect of our cusmers. Standard basic switches BZ Series are representative of Yamatake basic switches for their

More information

BZSeries. Basic Switches

BZSeries. Basic Switches Basic Switches BZSeries These switches have been used extensively and have earned the high respect of our cusmers. Standard basic switches BZ Series are representative of Yamatake basic switches for their

More information