Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:
|
|
- Scarlett Warren
- 6 years ago
- Views:
Transcription
1 Test This test allows you to establish whether your basic knowledge of pneumatic controls is sufficient for you to attend the advanced course P or whether you should attend the basic level course P. The test is designed to be completed quickly answers are multiple choice and do not require writing of words or sentences. You will find the correct answers in the Solutions sheet document.. Selecting a cylinder You have to select a pneumatic cylinder for installation in a machine. It must be able to exert a force of 00 N (approx. 0 kg) during its forward stroke. The return stroke is initiated by external force from the machine. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder. Setting the advancing speed The piston rod of the cylinder shown extends too quickly (motion to the right). You have to reduce the advancing speed. At which of the two one-way flow control valves would it be preferable to change the setting? A. One-way flow control valve B. One-way flow control valve 3. Selecting a valve A double-acting cylinder operates in a pneumatic system. The piston moves only to the forward or retracted end position (mechanical stop). Intermediate positions are not required. Which final control element (valve) should be used in this case? A. /-way valve B. 3/- way valve C. 5/- way valve D. 4/- way valve E. 4/3- way valve 4. Workpiece-clamping cylinder You have to select a cylinder / final control element combination for a workpiece-clamping cylinder. What overall behavior makes sense for this application? A. Bistable, retentive behavior, valve (final control element) without spring return B. Monostable, non-retentive behavior, valve (final control element) with spring return
2 5. Safe motion to end position A pneumatic cylinder operates in a production system. The sequence requires that the piston safely reaches its forward end position. Which pneumatic element would you use to ensure this? A. Timer (time delay valve, time relay ) B. Limit switch C. Pressure element (pressure sequence valve, electrical pressure switch) D. One-way flow control valve E. Shuttle valve (OR element) 6. Recognizing symbols You have installed valves requiring external lubrication into a previously unlubricated pneumatic control. A B C aaasa A Which of the valve combinations must you now install? D E 7. Recognizing valves by the port identification You have removed the valve shown from a control and want to replace it. What type of valve is it? A. 3/-way valve, pneumatically actuated on both sides B. 4/-way valve, pneumatically actuated, spring return C. 5/-way valve, pneumatically actuated, spring return D. 5/-way valve, pneumatically actuated on both sides E. 4/-way valve, solenoid-actuated
3 8. Way-valve designs Which type of valve is shown here? A. 5/-way valve (double pilot valve), suspended disk type B. 3/-way valve, ball poppet type C. 4/3-way valve, rotary slide type D. 5/-way valve (double pilot valve), slide valve type E. 3/-way valve, poppet type 9. Selecting a start pushbutton A system with multiple pneumatic cylinders is purely pneumatic. No electrical devices are installed. You have to install a suitable START pushbutton. What type of valve would you select as the start pushbutton? A. 3/-way valve, manually operated, normally closed B. 4/-way valve, manually operated, bistable C. 3/-way valve, manually operated, normally open D. /-way valve E. Dual-pressure valve 0. Selecting a valve You have to set up a pneumatic control. It must be possible for cylinder motion to be triggered by two different sensors at two different locations. Which additional valve must be installed? A B C D E
4 . Analyzing a simple circuit diagram The figure shows a simple electrical circuit comprising a Lamp H and the two switches S and S. Evaluate the following statements: +4 V S S H 0V Lamp H illuminates when Correct Incorrect... Switch S is operated.... Switch S is operated.... Both Switch S and S are operated.... Neither Switch S and S is operated. Mark your answers with a cross X in the appropriate column.. Selecting a valve combination A B C In a pneumatic control, the cylinder rod of a cylinder is only to extend after a delay of 0 seconds after signal input. 3 3 Which of the valve combinations shown must you install? D E 3
5 3. Detecting faults in a circuit diagram with one cylinder Documentation errors often cause time-consuming troubleshooting during commissioning. The circuit diagram shows the sequence for a simple control. Cylinder A should extend after actuation of S0 AND S, and return motion is controlled by S. Which of the following statements is correct? V A. Signal element S must provide a signal when cylinder A has reached the forward end position (right). For this reason, the position of S must be indicated by a mark on the front of the cylinder. B. The position of signal element S is incorrectly shown in the retracted position (left). S0 4 C. S0 must be mounted in the retracted position and should therefore also be designated there. D. The signal from S must act on the control side 4 and not on. E. The type of actuation Roller, mechanical for S is incorrect. 3 V /3 4 S 3 A 5 3 S S 3
ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)
The Advanced Customized Electro Pneumatic Trainer (SAP 20B) is capable of being used to demonstrate the design, construction and application of electro-pneumatic components and circuits. Objectives:- The
More informationSAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)
The Advanced Customized Electro Pneumatic Trainer (SAP 20B-I) is capable of being used to demonstrate the design, construction and application of electro-pneumatic components and circuits. Objectives:-
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS This work covers part of outcome 3 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome
More informationActuators and directional control valves
Actuators and directional control valves 1. Differentiate between the main types of directional control valves. 2. Demonstrate the function and uses of 3/2 way valve, push button actuated. 3. Demonstrate
More informationPneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008
Pneumatic Systems Module : Logic Operations in Electropneumatics PREPARED BY IAT Curriculum Unit August 2008 Institute of Applied Technology, 2008 2 Module : Logic Operations in Electro-pneumatics Module
More informationInput, Control and Processing elements
PNEUMATIC & HYDRAULIC SYSTEMS CHAPTER FIVE Input, Control and Processing elements Dr. Ibrahim Naimi Valves The function of valves is to control the fluid path or the pressure or the flow rate. Depending
More informationThe CASCADE Method. IA Cascade Method
The CASCADE Method similar to that for electromechanical devices. involves dividing the sequence into groups with each group s manifold (power or main pressure line) being supplied with pneumatic power
More informationHYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics
HYDROMODEL-200 Transparent Hydraulics - Electro-hydraulics Hydraulic and electro-hydraulic technology at a glance Implements and controls hydraulic and electro-hydraulic circuits www.smctraining.com training@smctraining.com
More informationJIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.
symbol s used in this catalog are old symbols following JISB0-: 00. Refer to JISB0-: 007 or JFPS0: 006 for new symbols. Page. Element of symbol. Line and port. Directional control valve. Pressure control
More informationPush buttons are of two types i) Momentary push button ii) Maintained contact or detent push button
ELECTRO-PNEUMATIC Push button switches A push button is a switch used to close or open an electric control circuit. They are primarily used for starting and stopping of operation of machinery. This causes
More informationMulti Processing Station with Oven 24V
- 536632 Multi Processing Station with Oven 24V I9 Q10 Q4 I1 O14 I8 Q7/Q8 I1 I3 I4 I2 Q3 not in the picture: Q1, Q2, Q5, Q6, Q9, Q11, Q12, Q13, I4, I5, I6, I7 Circuit layout of the Multi Processing Station
More informationME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.
ME 360 Test #3 Spring 08 5/5/08 Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6. 1) [10] Mark the following true (T) or false (F) questions a) Pressure relief
More informationG1/8-3/2-Way Valves - Series K9
PDE600PNUK 3/-Way Valves - Series K9 G1/8-3/-Way Valves - Series K9 Actuation: indexed spring return indexed, secured in two positons Pushbutton Cam operation Toggle cam operation Plunger operated Cam
More informationFRL unit consist of Filterations, Regulators and Lubricator unit.
4.1 AIR CONTROL 4.1.1 Fluid Conditioner FRL unit consist of Filterations, Regulators and Lubricator unit. It is also known as Air Service Unit. Primary function is to provide clean air at optimal pressure
More information[You may download this article at: https://fluidsys.org/downloads/ ]
Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org
More informationDISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:
Unit 1 Introduction to Electrical Control of Hydraulic Systems UNIT OBJECTIVE When you have completed this unit, you will be able to identify the components used for electrical control of the Hydraulics
More informationFunction Description Of Roll-over Bar
Function Description Of Roll-over Bar General The U-shaped roll-over bar is mounted on two main bearings on the left and right center pillars. In the retracted state the roll-over bar is positioned in
More informationElectrohydraulics Basic Level Textbook TP 601
Electrohydraulics Basic Level Textbook TP 601 Festo Didactic 093611 en Order No.: 093611 Edition: 03/2006 Authors: C. Löffler, D. Merkle, G. Prede, K. Rupp, D. Scholz Graphics: Doris Schwarzenberger Layout:
More informationProject Manual Industrial Hydraulics
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Project Manual Industrial Hydraulics RE 00845/04.07 Trainer s manual Electric Drives and Controls Hydraulics
More informationTest Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.
Test 1 1. Which statement is True? A. Pneumatic systems are more suitable than hydraulic systems to drive powerful machines. B. Mechanical systems transfer energy for longer distances than hydraulic systems.
More informationBasic Machine Interface Options
Limit Switch Version (515) 232-3188 www.razorgage.com Basic Machine Interface Options The Tool Safe Sensor is a limit switch to be installed on the user s saw, drill press, punch press, or whatever the
More informationThe pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.
Introduction In session 1 you have learned about pneumatic systems and their main components. In addition to that your lab instructor has introduced to you how to use FluidSIM software. During this appendix
More informationSubject: Pneumatic Training Kit with portable Air Compressor
MSME TOOL ROOM: HYDERABAD (CENTRAL INSTITUTE OF TOOL DESIGN) Balanagar, Hyderabad 500 037 TEL.NO.23772747, 23776168 FAX No.0-4023772658 E-mail:citdpurchase@citdindia.org Visit us: www.citdindia.org. TENDER
More informationFunction description of roll-over bar
91-800 Function description of roll-over bar Roll-over bar system, model 129 (version up to approx. 05/95) P91.50-0203-59 A1e29 Roll-over bar warning lamp (RB) S68/7 Front left seat belt buckle/seat belt
More informationSpecial valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves
Contents Description Page Dual-pressure valve (AND) 3 OR valve (OR) 33 Timer 34, 35 / way screw-in valves 36, 37 Miniature screw-in pressure regulators 38, 39 Relief valves 40 Special valves Logic components
More informationMINIVALVES, MECHANICALLY AND HAND OPERATED SERIES VME
MINIVALVES, MECHANICALLY AND HAND OPERATED SERIES VME Minivalves with / NO NC poppet, Installation in any position Push-in fittings for pipe Ø 4 mm and on the valve body Low actuation force Rapid, accurate
More informationPNEUMATIC & HYDRAULIC SYSTEMS
PNEUMATIC & HYDRAULIC SYSTEMS CHAPTER SIX PNEUMATIC SYSTEM DESIGN AND DEVELOPMENT Dr. Ibrahim Naimi Symbols And Standards In Pneumatics The development of pneumatic systems is assisted by a uniform approach
More informationZ1 B1 B2 Z2 B3 B4. Steuerteil + 24 V. Leistungsteil K1 K2 K1 K2. Practice for Professionals Electropneumatics Trainee s manual. Version 1.
04 Z1 B1 B2 04 Z2 B3 B4 31 14 Y1 12 4 2 5 3 1 15 31 14 Y2 12 4 2 5 3 1 15 Steuerteil + 24 V B1 S0 K1 B2 K2 B4 K3 B3 Leistungsteil 1 2 3 4 5 6 7 8 9 K4 K1 K2 0V K1 K2 K1 K3 K2 K4 K3 Y1 K3 Y2 Practice for
More informationSorting Line with Detection 24V
536633 Sorting Line with Detection 24V I2 Q2 I4 I3 I1 Coupling to multi processing station I5 I6 I7 Not in the picture: Q1, Q3, Q4, Q5 Circuit layout for Sorting Line with Detection Terminal no. Function
More informationCambridge International Examinations Cambridge International General Certificate of Secondary Education
www.xtremepapers.com Cambridge International Examinations Cambridge International General Certificate of Secondary Education *2641043214* DESIGN AND TECHNOLOGY 0445/43 Paper 4 Systems and Control October/November
More informationModule 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves
Terms and Definitions Categories of Valves Types of Pressure Control Valves Types and Operation of Pressure Relief Valves Operation of an Unloading Valve Operation of a Sequencing Valve Operation of a
More informationProjekthandbuch. Project Manual Industriehydraulik. Industrial Hydraulics RE 00846/ Trainee's manual. Schülerhandbuch
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Projekthandbuch Project Manual Industriehydraulik Industrial Hydraulics RE 00846/04.07 Schülerhandbuch
More informationOverview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests
Rev A, 5/26/2009 1 26 Overview This document describes the use of the Maintenance System. This test is a built in diagnostic feature of the GEN II System and provides maintenance personnel with a diagnostic
More information5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm
> Series E valves and solenoid valves Series E valves and solenoid valves 5/-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm Series
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationElectro Pneumatic WorkStation Scientech 2470
Electro Pneumatic WorkStation is designed to demonstrate the design, construction and application of Pneumatic components and circuits. It integrates PLC technology to build Hybrid Industrial Automation
More informationPneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves
Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob
More informationPersonal Restraint Hydraulic Lock "LE" for passenger restraint systems
Personal Restraint Hydraulic Lock "LE" for passenger restraint systems Description The LE locking system was developed specifically for installation in seats in amusement park rides and mobile structures.
More informationValves and Solenoid valves Series E 2/
CATALOGUE > Release 8.6 > Series E valves and solenoid valves Valves and Solenoid valves Series E 5/-way monostable/bistable - 5/3 CC CO CP With outlets on the body - For individual or manifold assembly
More informationLevel 7 Post Graduate Diploma in Engineering Mechatronics
9210-223 Level 7 Post Graduate Diploma in Engineering Mechatronics 0 You should have the following for this examination one answer book calculator (programmable calculators are not allowed) pen pencil
More informationFesto Modular Production System (MPS)
ELEC E8114 Manufacturing Automation Systems Modelling Festo Modular Production System (MPS) Figure 1 Distribution station (left) and testing station (right) 1 Introduction The purpose of this document
More informationBASIC PNEUMATIC & ELECTROPNEUMATIC TRAINING SYSTEM
BASIC PNEUMATIC & ELECTROPNEUMATIC TRAINING SYSTEM UCTECH has designed a comprehensive range of specialised training packages and products for pneumatic and electro-pneumatic training using well-known
More informationSuggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science
Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science Pneumatic and Electro-pneumatic components: No. EQUIPMENTS operating
More informationIntroduction. Pre-Lab
The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.2 Pneumatic Control of a Double-acting Cylinder Objective: Students will be
More informationI) Clamping the work piece II) Drilling the work piece. III) Unclamping the work piece. 10
Seventh Semester B.E. III IA Test, 2014 USN 1 P E M E PES INSTITUTE OF TECHNOLOGY (Bangalore South Campus) (Hosur Road, 1KM before Electronic City, Bangalore-560 100) Department of Mechanical Engineering
More information2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA
CATALOGUE > Release 8.8 > Series 7 valves and solenoid valves Series 7 valves and solenoid valves VDMA 4563 (ISO 15407-1) 5/ - 5/3-way CC CO CP Size 6 mm (VDMA 4563-01) Size 18 mm (VDMA 4563-0) GENERAL
More information: Automation Laboratory 1
Table A.1 shows elements found in FluidSIM library with a brief description for each of them. Compressed air supply The compressed air supply provides the needed compressed air. It contains a pressure
More informationCourseware Sample F0
Fluid Power Pneumatics Courseware Sample 31290-F0 ü FLUID POWER PNEUMATICS COURSEWARE SAMPLE by the Staff of Lab-Volt (Quebec) Ltd Copyright 1999 Lab-Volt Ltd All rights reserved. No part of this publication
More informationTechnical Bulletin AA 304. Central Locking System. m.y. 97
Technical Bulletin Subject: Model(s): Central Locking System Cabriolet m.y. 97 Group: Number: Date: 01 96 11 Nov. 29, 1996 The following Repair Manual pages are new and will be integrated with the next
More informationCh 4 Motor Control Devices
Ch 4 Motor Control Devices Part 1 Manually Operated Switches 1. List three examples of primary motor control devices. (P 66) Answer: Motor contactor, starter, and controller or anything that control the
More informationINTEGRATED ELEMENTS. 1. FLIP-FLOP VALVES (pneumatic) ORDER CODIFICATION : AZ100354
INTEGRATED ELEMENTS 1. FLIP-FLOP VALVES (pneumatic) It frequently happens that with only one pilot signal available it is necessary to determine any reciprocating movement having two stationary positions.
More informationFluid Power Systems: Hydraulics and Pneumatics
Fluid Power Systems: Hydraulics and Pneumatics Why Attend Fluid power systems (hydraulics and pneumatics) offer an alternate means of controlling industrial systems without a large number of electrical
More informationChapter 19. Applying Pneumatic Power. Typical Circuits and Systems
Chapter 19 Applying Pneumatic Power Typical Circuits and Systems 1 Objectives Describe basic circuits that are frequently used to assemble complex pneumatic systems. Identify the placement and explain
More informationLearning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1
Learning System for Automation and Communications Electropneumatics Workbook Basic Level 1 2 3 S1 K1 K1 S2 K1 094005 Order no. 094005 Description: TEACHW.E-PNEUM. Designation: D.S201-C-GB Edition: 08/1993
More informationBasic Hydraulics. Module 2: Actuators and directional control valves. Curriculum Development Unit PREPARED BY. August 2013
Basic Hydraulics Module 2: Actuators and directional control valves PREPARED BY Curriculum Development Unit August 2013 Applied Technology High Schools, 2013 ATM-312 Basic Hydraulics Module 2: Actuators
More informationTWO HAND NON-TIE-DOWN CONTROLS SC SERIES
TWO HAND NON-TIE-DOWN CONTROLS SC SERIES Complete Engineered Solutions Dynamco s SC Series of Two Hand Non-Tie-Down controls offers an engineered and completely assembled control product that can be used
More informationBG45 BG65S BG75 Axial Parallel Axial Parallel Axial Parallel CASM-32 (LS/BS/BN) X X CASM-40 (LS/BS/BN) X X X X CASM-63 (LS/BN/BF) X X
1 System Overview CASM electric cylinders powered by brushless DC motors are ideally suited for fast and powerful movements. Replacement of pneumatic cylinders has never been easier. Just parameterize
More information. Control unit (N53) The roll-over bar control unit is located on the tunnel below the rear seat.
A. Roll-over bar The roll-over bar (1) consists of high tensile strength tubular steel bent in a U-shape integrated into the head restraints (8) on both sides and recessed behind the rear seats. The roll-over
More informationATM 322 PNEUMATICS MODULE 4
ATM 322 PNEUMATICS MODULE 4 WARM UP VIDEO Explain the function of the one way flow control valve. Describe the main parts of the one way flow control valve. Adjust the one way flow control valve to the
More informationFlow sharing control block in sandwich plate design M7-25
Flow sharing control block in sandwich plate design M7-25 RE 64297 Edition: 07.2016 Replaces: 06.2012 Size 25 Series 3X Maximum working pressure on the pump side 380 bar on the consumer side 420 bar Maximum
More informationINSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.
FILE: 091-84.P65 date: 06-02-99 INSTRUCTION MANUAL ENGINE IDLER MODULE PART OF A HIGH IDLE SYSTEM ENGINE IDLER MODEL #091-84-005 VOLTGAE MONITOR MODEL #091-84-004 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO.,
More informationEngine-specific faults and their remedy are given in the operating manual of the engine manufacturer. Fault Possible cause Rectification
Simple troubleshooting D2-1.1 Engine Engine-specific faults and their remedy are given in the operating manual of the engine manufacturer. Fault Possible cause Rectification The superstructure cannot be
More informationTAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)
TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B) TECHNICAL MANUAL v1.3 JANUARY 2014 Technical Manual (Updated 6 th January 2014) No Vehicle timer Vehicle delay timer Overrun timer
More informationLESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:
LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES STP Tasks: 552-758-1003 552-758-1071 OVERVIEW LESSON DESCRIPTION: In this lesson you will
More informationElectro Pneumatic Workbench Scientech 2470
Scientech 2470 Electro Pneumatic Workbench is designed to demonstrate the design, construction and application of Pneumatic components and circuits. It integrates PLC technology to build Hybrid Industrial
More informationElectropneumatics Basic Level Set of Overhead Transparencies TP 201
Electropneumatics Basic Level Set of Overhead Transparencies TP 0 Festo Didactic 0950 en Order No.: 0950 Description: EL-PN.FOLIEN-GS Designation: D:OT-TP0-GB Edition: 0/000 Author: Frank Ebel Graphics:
More informationEngineering Science: Pneumatics ENGINEERING SCIENCE. Pneumatic Systems
ENGINEERING SCIENCE Pneumatic Systems Introduction Section 1: Pneumatic Systems Pneumatics is something that you probably know very little about yet come across every day without even realising it. Some
More informationControl/Dimming. Design / DELTA line 2/8. Design / DELTA vita 3/9. Design / DELTA miro 4/8
1 Selection and ordering data 5TG6 201 5TG6 200 General information Size of rockers: 55 mm x 55 mm Degree of protection IP20 The color aluminum metallic is identical to silver (DELTA profil) The color
More informationProcess switches and PLC circuits
Process switches and PLC circuits This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
More informationContinuing Education Course #206 Introduction to Designing Machine Control Systems Part 2
1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material
More informationPNEUMATE-200 Your mate in Pneumatics!
PNEUMATE-200 Your mate in Pneumatics! The compact trainer to help users discover more about pneumatic and electro-pneumatic technologies. www.smctraining.com training@smctraining.com 40 Develop the SKILLS...
More informationIndustrial Pneumatic Systems Syllabus [Detailed]
TECHNICAL TRAINING - SWAPPING DOWNTIME FOR PRODUCTIVITY! Industrial Pneumatic Systems Syllabus [Detailed] 1. Fundamentals of Fluid Power Systems. The three states of matter. Definition of a fluid. Derivation
More informationInstallation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596
Read all the following information and instructions prior to installing and operating the equipment. Failure to comply with these instructions could result in bodily injury or property damage. TABLE OF
More informationO500LE & O500RF OVERVIEW OF READING MB PNEUMATIC DIAGRAMS AND PORT IDENTIFICATION. DaimlerChrysler Australia / Pacific Service & Parts CV
OVERVIEW OF READING MB PNEUMATIC DIAGRAMS AND PORT IDENTIFICATION Understanding Pneumatic Diagrams Port Numbering Mercedes-Benz use a standard method for that allows for easy identification of the pneumatic
More informationPREHEATER BYPASS SYSTEMS
PREHEATER BYPASS SYSTEMS PREHEATER BYPASS SYSTEMS OVERVIEW 2014 GS FEED WATER HEATER BYPASS SYSTEM General Description These valves are designed to bypass high pressure feed water around the pre-heaters
More informationMaintenance Guide AZTEC BNF-2000 BILL ACCEPTOR PRIMARY COMPONENT PARTS
AZTEC BNF-2000 Bill Acceptor Maintenance Guide October, 2007 October, 2007 Maintenance Guide JCM is a registered trademark of JCM American Corporation. All other product names mentioned herein may be registered
More information2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),
More informationElectro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani
Electro - 9 Hydraulics & Pneumatics 2 Electro Hydraulic Press The hydraulic press is controlled via the electrical control panel. Electrical signals are used to activate the valves in the hydraulic installation.
More informationCURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY
ANNEXURE - A CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) Host Institute: GANPAT UNIVERSITY Contents of Basic Industrial Pneumatics -----------------------------------------------------------------------------------------------------------------
More informationCoating systems. Subject to change. Krautzberger GmbH /
185 Automatic rotary R 700 indexing units Automatic rotary indexing unit R 700 The Krautzberger R 700 automatic rotary indexing unit is designed for the coating of serial components. Output is designed
More informationLECTURE 15 TO 17 DIRECTIONAL CONTROL VALVES FREQUENTLY ASKED QUESTIONS
LECURE 15 O 17 DIRECIONL CONROL VLVES FREQUENLY SKED QUESIONS 1. Explain briefly the function of directional control valves o o start, stop, accelerate, decelerate and change the direction of motion of
More informationSOFT TOUCH A NEW STANDARD FUNCTION FOR UNITROL SOLUTION
SOFT TOUCH A NEW STANDARD FUNCTION FOR UNITROL SOLUTION LOW FORCE BETWEEN ELECTRODES UNTIL SAFE UNITROL announces a new safety function that is now standard on all 9180 series SOLUTION controls without
More informationHYDROTRAINER-200 Hydraulics - Electro-hydraulics
HYDROTRAINER-200 Hydraulics - Electro-hydraulics Hydraulics and electro-hydraulics within your reach www.smctraining.com training@smctraining.com 80 Develop the SKILLS... Analysis Troubleshooting Implements
More informationSeries 3 valves are equipped with a manual override which allows a stable operation and they can use Series U or G solenoids (22x22).
> Series 3 valves and solenoid valves Valves and Solenoid valves Series 3 x3/, 3/, 5/ and 5/3-way CC CO CP Ports G1/8 and G1/4 Series 3 solenoid valves with G1/8 and G1/4 ports have been designed in the
More information8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification
More informationDIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL
More informationCommon wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.
/ and 4/ multi-way valves; servo assisted; DN 4; flow rate: l/min.; /8, legris ø 6 mm port connections Advantages / Benefits Optimised system solutions due to high level of modularity Compact design with
More informationFLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:
FLUID POWER P&IDs Fluid power diagrams and schematics require an independent review because they use a unique set of symbols and conventions. EO 1.11 IDENTIFY the symbols used on engineering fluid power
More informationFront panel valves SV
Front panel valves SV Key features T N H Q P PR PRS SVS-3-1/8 SVOS-3-1/8 SV-3-M5 SV-5-M5-B SV/O-3-PK-3X2 Actuator attachments Pushbutton T Switch N, H, Q Mushroom pushbutton/mushroom pushbutton with detent
More informationTRESHOLD SENSORS LOGIC PNEUMATIC COUNTERS TIMERS VALVES
PNEUMATIC TIMERS N.C / N.O. PNEUMATIC COUNTERS with / VALVE PANEL MOUNTED PNEUMATIC COUNTERS LOJIC VALVES OR GATES TRESHOLD SENSORS LOGIC PNEUMATIC COUNTERS TIMERS VALVES LOGIC PNEUMATIC LOGIC VALVES
More informationModern Industrial Pneumatics. Design and Troubleshooting Industrial Pneumatics PN111 PN121
Modern Industrial Pneumatics Design and Troubleshooting Industrial Pneumatics PN111 PN121 Drives: Cylinders for different drive purposes Valves: Various valve types (pneumatically/electrically controlled,
More informationWhite paper: Pneumatics or electrics important criteria when choosing technology
White paper: Pneumatics or electrics important criteria when choosing technology The requirements for modern production plants are becoming increasingly complex. It is therefore essential that the drive
More informationLesson 5: Directional Control Valves
: Directional Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Directional
More informationCH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G
Content : 4.1 Hydraulic and Pneumatic actuators. 10 Marks Hydraulic Actuators - Hydraulic cylinders (single, double acting and telescopic) construction and working, Hydraulic motors (gear and piston type)
More informationThin-line. Weld Heads
Thin-line Weld Heads AMADA MIYACHI's Thin-Line Heads for spot welding applications comprise three families of fullfeatured products for resistance spot welding: 80 Series (0.25 lbs (N) - 40 lbs (78N)),
More informationAir. Time delay. Figure 60. We can change the length of a delay by changing the size of the reservoir or adjusting the restrictor.
Time delay Sometimes in a circuit we want a pause or delay before something else happens. To create a delay we need to use two components a unidirectional restrictor and a reservoir. A reservoir is simply
More informationSUMMARY KIT PNEUMATIC MOTION
SUMMARY G1 P CONFIGURABLE (KIT PMC) G1.2 P READY (KIT PMR) G1.3 P CUSTOM G1.9 SUMMARY G1.1 CONFIGURABLE (KIT PMC) An on-line configurator is provided for the ease-and-quick selection of the cylinder, the
More informationSyslog Technologies Innovative Thoughts
AUTOMATIC PNEUMATIC WATER PUMPING SYSTEM SYNOPSIS The aim of the project is pneumatic operated water pumping system. Radial plunger Pneumatic Water pumping system are reciprocating pump in which the piston
More informationModels CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3
Models 94422 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" MAY - 2004 FORM 403467 Section - Q3 Page - 13C 9.00" (229 mm) 13.75" (350 mm) 0.35" (9mm) Mounting Holes 4.76" (121 mm) 9.84" (250 mm) Do not use
More informationModel CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"
Model 94222 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" Indicates change MAY - 2004 FORM 403466 Section - Q3 Page - 12B 7.75" (197 mm) 12.6" (321 mm) 0.35" (9 mm) Mounting Holes 4.85" (123 mm) 8.85" (225
More information