List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME

Size: px
Start display at page:

Download "List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME"

Transcription

1 Terms and Conditions : 1) Before proceed please confirm material documents and test documents are available with you. 2) Vendor Document Verification Registration Fee Rs payment gateway charges, taxes applicable if any. 3) Only Online Payment will be accepted. 4) Once Payment of Registration Fee is done, amount will not be refunded in any case. List of Mandatory Commercial Documents 999 Commercial Mandatory Documents Company Registration Document viz DIC/NSIC/MSME any other Performance feed backfrom customers for last two years of the product supplied for which vendor approval is required Last five years orders executed list, sample orders of sizable amount for the product under vendor approval Last three years turnover certificate certified by CA for the product under vendor appoval Page 1 of 9

2 1 Distribution Transformer 2 DISTRIBUTION TRANSFORMERS WITH CSP FEATURE. 3 Power Transformer for Distribution Transformer Impulse Voltage with stand Test on all three HV phases chopped on tail General Dimensional drawing. (Side, front & Top View) Dynamic Short circuit Test As per IS 2026 Core Assembly drawing as per specification. Temperature Rise Test, tested at NABL Lab or factory can accepted. Internal Construction Drawing (Side, front & Top View) Air pressure test as per clause no of IS:1180 (Part I)/1989, tested at NABL Lab or factory can accepted. Unbalanced current test unbalanced current should not be Rating & Diagram Plate Drawing. more than 2% of full load current, tested at NABL Lab or factory can accepted. HV Bushings indicating measurement of creepage distances. LV Bushings indicating measurement of creepage distances. HV Bushings assembly drawing LV Bushings assembly drawing Breather Drawing Minimum Annual Turn Over Rs.5 Crores for DISTRIBUTION TRANSFORMERS WITH CSP FEATURE. Impulse Voltage with stand Test on all three HV phases chopped on tail General Dimensional drawing. (Side, front & Top View) Dynamic Short circuit Test As per IS 2026 Temperature Rise Test, tested at NABL Lab or factory can Core Assembly drawing as per specification. accepted. Air pressure test as per clause no of IS:1180 (Part Internal Construction Drawing (Side, front & Top View) I)/1989, tested at NABL Lab or factory can accepted. Unbalanced current test unbalanced current should not be Rating & Diagram Plate Drawing. more than 2% of full load current, tested at NABL Lab or factory can accepted. HV Bushings indicating measurement of creepage distances. Time current characterstics on HT Fuse LV Bushings indicating measurement of creepage distances. Test sequence- I : For LT circuit Breaker HV Bushings assembly drawing Test sequence- II : For LT circuit Breaker LV Bushings assembly drawing Test sequence- III : For LT circuit Breaker Breather Drawing CQR Breaker 3 phase 3 pole major part indetification. Standard protection co-ordinatin graph Minimum Annual Turn Over Rs.5 Crores Impulse Voltage with stand Test on all three HV phases for Power Transformer chopped on tail Rating & Diagram Plate Dynamic Short circuit Test As per IS 2026 General Arrangement Temperature Rise Test Air pressure test as per clause no of IS:1180 (Part Foundation Details I)/1989, tested at NABL Lab or factory can accepted. Unbalanced current test unbalanced current should not be Internal Construction Core, Coil & Connection Assy. more than 2% of full load current, tested at NABL Lab or factory can accepted. Core Section Details with flux density calculations. H.V. Bushing Details Creepage Distance of H.V. Bushing L.V. Bushing Details Creepage Distance of L.V. Bushing Breather Valve Schedule Plate General Arrangement for Marshalling Box Alarm & Indication Circuit Diagram of Marshalling Box General Assembly of OLTC Tap changer G.A. of RTCC Panel Schematic Diagram For O.L.T.C. & R.T.C.C. OLTC Rating Plate Phase Diagram Coarse Fine Winding Bill Of Materials Transformer Bill Of Materials O.L.T.C. Packing List Minimum Annual Turn Over Rs.25 Crores Page 2 of 9

3 4 5 & Specification sheet Out of Phase making & breaking test LEGEND with item designation & bill Of Material Single phase short circuit test & Double earth fault test Circuit Breaker Schematics, Breaker Closing & tripping Circuit. Basic short circuit duties Circuit Breaker Schematics, Indicating Circuit & spare Contacts. Dry & Wet Power frequency voltage withstand test Motor Circuit & Panel Accessories Degree of Protection IP-55 Terminal Top/ Bottom PAD arrangement for Outgoing VCB Lightning Impulse Voltage withstand Test Minimum Annual Turn Over Rs.50 Crores Mechanical Operation Test (M2) 36 kv, 1600A, 25kA/ 11 KV, Short Time Withstand Current and Peak Withstand Current General Arrangement Drawing 800 A, 12.5 KA, Out door tests Vacuum Circuit Breaker Structure assembly for breaker Temperature Rise Test Rating Plate of 33 Kv OD VCB Cable charging current switching tests Switch plate assembly Single capacitor bank current Switching test Insulator Body Interrupter Assembly Pole Assembly Aluminium terminal connector Palm Type Bill of Material / Packing List. 11 KV & 22 KV I/D Switchgear 6 36 KV Isolator for 11 KV & 22 KV I/D Switchgear Information Sheet Single Line Diagram General Arrangement of 9 VCB Switchboard, C&R panel and Buscoupler panels Legend & Notes Wiring Diagram of Incomer VCB & C&R Panel T.B. Diagram of Incomer Wiring Diagram of Outgoing T.B. Diagram of Outgoing Wiring Diagram of Buscoupler T.B. Diagram of Buscoupler Bill Of Material ( VCB ) Bill Of Material (C&R ) for 36 KV Isolator Switchgear Panel : Lightening Impulse Voltage withstand tests, Switchgear Panel : Short time withstand and peak withstand current test Switchgear Panel : Temperature Rise test Switchgear Panel : Short circuit tests, Single phase and double earth fault tests, out of phase making and braking tests, Basic Short circuit test duties Switchgear Panel : Mechanical operation test Switchgear Panel : H. V Dry power frequency voltage withstand tests Switchgear Panel : Short time withstand current test Switchgear Panel : Degree of protection IP-4X Potential Transformer : All routine tests Potential Transformer : Temperature Rise Test Potential Transformer : Lightening Impulse Voltage Withstand Test Current Transformer : all routine tests before & after Short Time Current test. Current Transformer : Temperature Rise Test Current Transformer : Lightening Impulse Voltage Withstand Test Current Transformer : Determination of error. Short time withstand current and peak withstand current test General outline and assembly drawings of the disconnect, Dry power frequency voltage withstand test Sectional views and descriptive details of items Wet power frequency voltage withstand test Detail drawing of contacts (fixed & moving) Lighting impulse voltage withstand test contact support,bearing, housing of bearings, Mechanical operation test Details of design foundation tempreture rise test Name plate. Measurement of resistance of main circuit Sectional views and descriptive details of items such as moving special tests on Terminal connectors as per IS 5561 Auxillary switch box for main switch Special Tests on Solid core insulator As per IS 2544 Terminal connector drawing Base channel drawing. 36 kv solid core post insulator. Packing list. Page 3 of 9

4 KV & 22 KV C & R Pannel with And Without Differential Relay 33 KV & 22 KV C & R Feeder Pannel 9 Feeder Pillar 10 CTs Type test for Numerical Relay,Master tripo, Auxilary relay, Differntial relay Meter Functional Test (Under normal operating condition ) Technical details of control & Relay Panel (Indoor Type). Power consumption in current circuit General Arrangement of control & Relay Panel(Indoor Type). Power consumption in auxiliary circuit Metering circuit of control & Relay Panel (Indoor Type). Dielectric test Protection Circuit of control & Relay Panel (Indoor Type). Impulse voltage test Tripping circuit of control & Relay Panel ( Indoor Type). High frequency interference test Closing, Tripping circuit of control & Relay Panel (Indoor Type). Radiated radio frequency electromagnetic field immunity test Indication Circuit of control & Relay Panel Indoor Type). Surge immunity test Annunciation circuit of control & Relay Panel (Indoor Type). Electrostatic discharge test AC & DC distribution circuit of control & Relay Panel (Indoor Fast transient disturbance test Terminal details of control & Relay Panel (Indoor Type). Vibration response test Bill of Material for 33 kv Transformer (Indoor Type). Shock response test Cold test (storage & operating) Dry heat test (Storage & Operating ) Degree of protection IP 54 Thermal (short time thermal withstand test) Drop out, pick up, ratio test DC Supply Interuption AC ripples on DC supply Voltage dips and short interuption Operating Value test Operating time test Type test for Numerical Relay,Master tripo, Auxilary relay, Differntial relay Meter Functional Test (Under normal operating condition ) Technical details of control & Relay Panel (Indoor Type). Power consumption in current circuit General Arrangement of control & Relay Panel(Indoor Type). Power consumption in auxiliary circuit Metering circuit of control & Relay Panel (Indoor Type). Dielectric test Protection Circuit of control & Relay Panel (Indoor Type). Impulse voltage test Tripping circuit of control & Relay Panel ( Indoor Type). High frequency interference test Closing, Tripping circuit of control & Relay Panel (Indoor Type). Indication Circuit of control & Relay Panel Indoor Type). AC & DC distribution circuit of control & Relay Panel (Indoor Terminal details of control & Relay Panel (Indoor Type). Bill of Material for 33 kv Transformer (Indoor Type). for Feeder Pillar for ACB (if with ACB) G.A. Drawing of Feeder Pillar Radiated radio frequency electromagnetic field immunity test Surge immunity test Electrostatic discharge test Fast transient disturbance test Vibration response test Shock response test Cold test (storage & operating) Dry heat test (Storage & Operating ) Degree of protection IP 54 Thermal (short time thermal withstand test) Drop out, pick up, ratio test DC Supply Interuption AC ripples on DC supply Voltage dips and short interuption Operating Value test Operating time test Energy Meter Type tests as per meter test list. As per relevant IS Panel IP test Type Test on Complete Feeder Pillar as per IS:5039/1983 Verification of Temperature rise limits Verification of short circuit strength Verification of Clearance & Creepage Distances Verification Of Dielectric Properties. Verification of Degree of protection for IP-43 Type Test On ACB as per IS:13947/1993(Part II amended upto date) Type Test On HRC fuses and HRC fuse links as per IS:13703/1993(Part I & II amended upto date) Determination of Error Test for CT GA drawing for CT Wet HV Power frequency voltage withstand test Temperature rise test Lightning Impulse Voltage Withstand Test. Page 4 of 9

5 11 PTs 12 Capacitor LTDB with Link Disconnector LTDB With M C C B (IS: 13947(Part -2):1993) for PT Short time current test. GA drawing for PT Determination of Error Test Wet HV Power frequency voltage withstand test Temperature rise test Lightning Impulse Voltage Withstand Test. Minimum Annual Turn Over Rs.5 Crores Type Test on capacitor unit as per IS 13925(Part 1)/1998 for Capacitor Bank Thermal stability test GA drawing for Capacitor Bank Capacitor loss tangent measurement at elevated temperature GA drawing for Capacitor Unit AC voltage test between terminal and containers Lightning Impulse Voltage Test between terminal and containers. Short Circuit discharge test. Voltage test between terminals. for LTDB Test carried out on bought out item as per IS Link Disconnector(IS: 13947(Part -3):1993) Test Sequence-I Verification Temperature Rise Test Dielectric Properties Leakage Current Test Sequence-II(Operational Characteristics) Mechanical Operation & Operational Performance Capability Temperature Rise Verification Test Leakage Current Dielectric verificaton Test Sequence-III(Short Circuit Performance Capability) Short Circuit withstand Current Dielectric verificaton Leakage Current Temperature Rise Verification Mechanical Operation and operational performance capability Over Load Performance Rated Service Short Circuit Breaking Capacity Rated Ultimate Short Circuit Breaking Capacity Verification of time Current Characteristics Page 5 of 9

6 LTDB With Kit Kat (IS: 2086:1993) LTDB With Switch Disconnector (IS:13947(Part 3):1993) LTDB With HRC Fuse(IS:13703(Part I & II):1993) for LTDB Breaking Capacity Mechanical Test Sequence Visual Examination Test for Dimension Test for mechanical endurance Test for mechanical strength Test for withdrawal strength Test for withdrawal force Electrical Test Sequence Test for temperature rise Insulation resistance test Test for proving material properties Test for water absorption(ceramic material) Test on ceramic material Ignition test(for non- ceramic materials) for LTDB General Performance characteristics Tripping limits and characteristics Dielectric Properties Mechanical Operation and operational performance capability Over Load Performance Rated Service Short Circuit Breaking Capacity Rated Ultimate Short Circuit Breaking Capacity Conventional cable overload protection Operation of indicating device Freedom from seasonal cracking Degree of Protection for LTDB G.A. Drawing of LTDB Verification of Temperature rise limits Verification of Breaking Current at Current I1 Physical Dimension Resistance record in Milliohms Temperature rise & Power Dissipation conventional non fusing current conventional fusing current Rated current Verification of time Current characteristic Overload Test Resistance to rusting Page 6 of 9

7 LTDB With Fuse Link(IS (Part I & II): 1993) HT Cable As per IS-7098 Part-II 1985 ( IS-7098 Part-II 2011 likely to be applicable) LT Cable As per IS-7098 Part-I 1985 for LTDB Verification of Breaking Current at Current I1 Physical Dimension Resistance record in Milliohms Temperature rise & Power Dissipation conventional non fusing current conventional fusing current Rated current Verification of time Current characteristic Overload Test Operation of indicating device Conventional cable overload protection Degree of Protection Freedom from seasonal cracking Resistance to rusting Test for water absorption(ceramic material) Test on ceramic material Ignition test(for non- ceramic materials) BIS liecence High Voltage tests Minimum Annual Turn Over Rs.40 Crores Test on Conductor tensile test, (For Aluminum) for Cables Test on Conductor Wraping Tests, (For Aluminum) Test for Armouring Wires/ Strips Test for Thichness of insulation & sheath BIS liecence Minimum Annual Turn Over Rs.20 Crores for Cables Physical Tests for Insulation tensile test & elongination at break Physical Tests for Insulation Ageing in Air oven Physical Tests for Insulation Hot set test Physical Tests for Insulation Shrinkage Test Physical Tests for Insulation Water absorption Test Physical tests for outer sheath tensile test & elongination at break Physical tests for outer sheath Ageing in Air oven Physical tests for outer sheath Shrinkage Test Physical tests for outer sheath Hot Deformation Test Partial Discharge Tests Bending Tests Di-electric Power factor test Function of Voltage Di-electric Power factor test Function of Temperature Insulation Resistance test Heating cycle tests Flammability Tests Test on Conductor tensile test, (For Aluminum) Test for Armouring Wires/ Strips Test for Thichness of insulation & sheath Physical Tests for Insulation tensile test & elongination at break Physical Tests for Insulation Ageing in Air oven Physical Tests for Insulation Hot set test Physical Tests for Insulation Shrinkage Test Physical Tests for Insulation Water absorption Test Physical tests for outer sheath tensile test & elongination at break Physical tests for outer sheath Ageing in Air oven Physical tests for outer sheath Shrinkage Test Physical tests for outer sheath Hot Deformation Test Physical tests for outer sheath Heat Shock Test Physical tests for outer sheath Thermal Stability Insulation Resistance test High Voltage tests Flammability Tests Test on Conductor Wraping Tests, (For Aluminum) Page 7 of 9

8 BIS liecence TEST FOR SURFACE CONDITION 21 HT Conductor for Conductor ULTIMATE BREAKING LOAD TEST RESISTANCE TEST BIS liecence TEST FOR SURFACE CONDITION 22 LT Conductor for Conductor ULTIMATE BREAKING LOAD TEST RESISTANCE TEST Sectional Drawing Freedom from defect 23 RSJ Pole Chemical Composition Tensile & Bending tests Diamentional Drawing Visual Examination. for Insulators Verification of dimensions. Visible Discharge Test Impulse Voltage Withstand Test. 24 Porcelain type of Insulator Wet Power Frequency Voltage Withstand Test Electro-Mechanical failing load test. Power frequency puncture withstand test. Porosity test. Temperature Cycle Test. Diamentional Drawing Dry lightning impulse withstand voltage test As per IEC 61109(Clause 6.1) for Insulators Wet power frequency test As per IEC 61109(Clause 6.2) Mechanical load-time test As per IEC 61109(Clause 6.4) 25 Composite type Insulator Radio interference test As per IEC 61109(Clause 6.5) Chemical composition test for silicon content Annexure B or any other test method acceptable to the owner Brittle fracture resistance test Annexure B Recovery of Hydrophobicity test Annexure B This test may be repeated every 3yrs by the manufacturer Name Plate Drawing Insulation withstand Test Residual Voltage Tests Lightning Arrestor Diamentional Drawing Long Duration current impulse withstand tests 26 Lightning Arrestor Operating Duty Test Tests on Arrestor Disconnector Porosity Tests Galvenising Tests on exposed ferrous metal parts Artificial Pollution tests Name Plate Drawing Internal arc withstand of RMU & Associated Items Pressure withstand test 27 RMU 28 PSC Pole G.A.Drawing Fondation Drawing Mimic Drawing Cross Sectional View Drawing Single Line Diagram Bill of Material Scheme Details Short time current withstand test & peak current withstand test Lightning impulse voltage withstand test Temp rise test Short time current making & breaking test Power frequency voltage withstand test(dry) Capacitive current switching test Mechnical operation test Measurement of resistance of main circuit Degree of Protection IP-54 & IP-67 Switching circuit breaker, earthing switch making capacity test Switch,circuit breaker breaking capacity Checking of PD test Drawing Cube Strenght Tests Deflection Tests (Load Tests) Page 8 of 9

9 29 LT PVC Cable 30 Battery 31 Battery Charger for PVC Cable Test on Conductor tensile test, (For Aluminum) Conductor resistance test Test for armouring wires/strips Test for thickness of insulation and sheath Physical tests for insulation and outer sheath: Tensile strength and elongation at break Physical tests for outer sheath tensile test & elongination at break Physical tests for outer sheath Ageing in Air oven Physical tests for outer sheath Shrinkage Test Physical tests for outer sheath Hot Deformation Test Physical tests for outer sheath Heat Shock Test Physical tests for outer sheath Thermal Stability Insulation resistance test High voltage test ( water immersion test ) High voltage test at room temperature Flammability test Test on Conductor Wraping Tests, (For Aluminum) Varification of Constructional requirment Varification of Marking Varification of Diamention Test for capacity Amper hour & Watt Hour effieciency Test Test for Loss of Capacity on Storage Endurance Test Test for Voltage during discharge Visible Battary Charging Test Ampers-Hours Capacity vs year of service Curve showing cell voltage vs time at different descharge rate Curve showing cell voltage vs time at different Charging Current Battery layout Drawing Page 9 of 9

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 2 SWITCHBOARDS Overview Also called Switchgear and Controlgear Assembly

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

Distribution transformers Efficiency over life-cycle

Distribution transformers Efficiency over life-cycle Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING 1 DEPARTMENT OF ELECTRICAL ENGINEERING Introduction to High Voltage Testing It is essential to ensure that the electrical equipment is capable of withstanding the overvoltages that are met within the service.

More information

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY Phone: +91 431 257 79 38 Fax

More information

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:

More information

Technical Specification of GECOL. Packaged Transformers

Technical Specification of GECOL. Packaged Transformers GES 26211 Technical Specification of GECOL Packaged Transformers (Revision history) Issued on: Jan. 01, 2007 General Electricity Company of Libya Contents 1 SCOPE AND SERVICE CONDITIONS... 6 1.1 SCOPE...

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing

More information

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks

More information

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12) s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA 017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS PAGE 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable Standards 3 5. Basic Features 4 6. Quality

More information

ype UP T Busplugs Low Voltage Switchboard Equipment

ype UP T Busplugs Low Voltage Switchboard Equipment Busplugs Type UP Low Voltage Switchboard Equipment Publication UP 2013 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents Descriptive

More information

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date Last Amended on - Page 1 of 6 I. CABLES AND ACCESSORIES 1. PVC Insulated Cables Tests on Conductor: Annealing Test (copper) IS 10810 (Part 1):1984 (RA 2011) 0 to 50 % Tensile Test (Aluminium) IS 10810

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications Outdoor live tank SF 6 circuit breaker Type OHB for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers

More information

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast. ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW High performance alternative to air

More information

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society Guideline No.: E-07(201610) E-07 TRANSFORMERS Issued date: October 28,2016 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system. MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham

More information

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton creates power-engineering

More information

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT 33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,

More information

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton Holec creates power-engineering

More information

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated

More information

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB Annexure-V (Under Two Part Bid System) Tender No: NFV/ PUR/ BEC 160546 K for VCB Technical specification for NIT SL NO 1 S.No. Description NFL requirement as per NIT Vendors Comment [Agreed / If not agreed,

More information

Visual comparison of Plain & Hazy PP Film

Visual comparison of Plain & Hazy PP Film ECOVAR High Voltage Power Capacitors are manufactured at our Sinnar Plant in India which is an ISO 9001 accredited facility & houses a computer aided design manufacturing processing and testing infrastructure

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

34-SDMS-02 SPECIFICATIONS FOR

34-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

COMPACT SUBSTATION GUIDE

COMPACT SUBSTATION GUIDE COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314

More information

SWITCHBOARDS (LV and MV)

SWITCHBOARDS (LV and MV) ELEC9713 Industrial and Commercial Power Systems SWITCHBOARDS (LV and MV) 1. Introduction Depending on the size of the building or factory site and whether the supply is high voltage or low voltage, there

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls 11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the

More information

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES 1 TABLE OF CONTENTS 1. SCOPE 2. GENERAL 2.1 STANDARDS AND REGULATIONS 2.2 OPERATING CONDITIONS 2.3 DOCUMENTATION

More information

Independent Testing Laboratory for High Voltage Equipment

Independent Testing Laboratory for High Voltage Equipment T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.

More information

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme) Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS

More information

ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST:

ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST: Sr. Item Description No. (A) Material Management Cell 1 Meters(All types) 2 GSM Modem ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST: 3 Metering Cubicles 4 L.T. Distribution Box 5 L.T. XLPE Cable 6

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

EE 741 Over-voltage and Overcurrent. Spring 2014

EE 741 Over-voltage and Overcurrent. Spring 2014 EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with

More information

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA 023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir

More information

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES TECHNICAL SPECIFICATION UP TO 36 kv METAL-CLAD With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES 1 TABLE OF CONTENTS 1. SCOPE 2. GENERAL 2.1 STANDARDS AND REGULATIONS 2.2 OPERATING CONDITIONS

More information

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Solid Dielectric, Three Phase Reclosers CATALOG VS11 Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

Extensible Unit - VCE2a

Extensible Unit - VCE2a ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY

More information

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS STANDARD METAL CLAD INDOOR VCB TECHNICAL DATA Rated Voltage (Ur) in kv 12 Rated Normal Current (Ir) in Ampere 630/1250 Rated Frequency (fr) in Hz 50 Rated Insulation level (1 min)

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

شركة كهرباء محافظة القدس المساهمة المحدودة

شركة كهرباء محافظة القدس المساهمة المحدودة Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories

More information

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications 4-O 1/15 Combined Current and Voltage Instrument Transformer CVS-P-4-O Technical Specifications Rev. Date Revision Description Prepared by Checked by Approved by 0 3/10/15 First Issue E. Scala L. Peretto

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

High Voltage and Extra High Voltage Cables

High Voltage and Extra High Voltage Cables High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high

More information

32-SDMS-01 REV. 02 SPECIFICATIONS FOR

32-SDMS-01 REV. 02 SPECIFICATIONS FOR 32-SDMS-01 REV. 02 SPECIFICATIONS FOR NON-EXTENSIBLE SF6 INSULATED RING MAIN UNIT, 17.5 KV This specification is property of SEC and subject to change or modification without any notice CONTENTS PAGE 1.0

More information

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6 INDEX : Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3 2 Technical Perticular for Capacitor Unit 4 3 MV Surge Capacitor Unit Drawings 6 4 Technical Perticular for Surge Capacitor Unit 7 5 MV Energy

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS TITLE SPECIFICATION FOR POLE- MOUNTED DATE: JUNE 2006 PAGE: 1 OF 17 TABLE OF CONTENTS Page FOREWORD...2 INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DEFINITIONS AND ABBIATIONS...3 4 REQUIREMENTS...3

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A Technical Specification Of 12KV, 400A, 18.4 KA Floor Mounted totally enclosed Ring Main Unit consisting of 2 nos. Vacuum Interrupting Incoming Unit and one no. Series Trip Metering Switchgear with Vacuum

More information

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy. Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that

More information

TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY.

TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY. TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY. 1.0 SCOPE: This specification covers the design, manufacturing and testing of LT Distribution

More information

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering University of Sydney School of Electrical and Information Engineering Dr Keith Mitchell ELEC 5205 - High Voltage Engineering ELEC 5205 - High Voltage Engineering 3. Switchgear Types of Power System Switchgear

More information

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

PSW102 type CT powered protection unit

PSW102 type CT powered protection unit PSW102 type CT powered protection unit Summary PSW102CT self-powered protection device is a 10Kv feeder protection device which has the function of over current, fast breaking protection and grounding

More information

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION 92 Section VI. Schedule of Requirements 7.0 Technical Guarantee Specification of 60MV, 132/33 Mobile Substation TECHNICL DT SCHEDULE 60MV, 132/33 MOBILE SUBSTTION ITEM DESCRIPTION UNITS REQUIRED GURNTEED

More information

43-SDMS-01 SPECIFICATIONS FOR

43-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR MV SHUNT POWER CAPACITOR BANK UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Description Page 1.0 SCOPE 3

More information

Adak Behin Niroo. co.com

Adak Behin Niroo.   co.com Adak Behin Niroo www.adakbn co.com PRODUCTS LOW VOLTAGE SWITCHGEARS MEDIUM VOLTAGE SWITCHGEARS PRODUCTS LOW VOLTAGE SWITCHGEARS www.adakbn co.com High Standard Type Tested Know How

More information