1 CFORMS TO STD CLASS - I, II, III, IV CERTIFIED TO CAN/CSA STD C. NO HP 100/00/FAST Entrapment Protection REQUIRED Residential / Commercial Brushless DC Swing Gate Operators Made in USA MEGATR 100 / 100HP / 00 / FAST Single or Bi-Parting Gates Single or Bi-Parting Gates Single or Bi-Parting Gates Bi-Parting Gates LY Installation and Owners Manual

2

3 Table of contents Megatron Specifications Important Safety Information Model Classifications Required Entrapment Protection Compliant Installation Requirements Intended Use of Swing Gate Operator Installation Gate Operator Position Recommended Gate Operator Layout Layout and Arm Height of 100/00/FAST or 100HP Dual Gate Operators Arm Position Options Arm Connection to Gate Optional Remote Power Supply Kit - Magic Box Compact Installation LY Solar Optional Entrapment Protection In-Ground Loops Install Warning Signs Wiring operator Gate Operator System Overview Input AC Power Optional Remote Power Supply Kit - Magic Box Solar Power Connection - Optional Secondary Operator to Matrix 1 Turn / Operator Power matrix 1 Matrix 1 Overview Wiring Overview Primary Gate - Open Left / Open Right Close Timer Selectable Gate Speed Control Battery Back-Up Mode Anti-Tailgate Single Pass Anti-Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarms OBD Port Black Box Maglock Loop Detectors In-Ground Loop Connection Plug Gate Tamper Entrapment LEDs Emergency Vehicle / Max Open Inputs Gate Disable Partial Open Alarm / Shut-Off Alarm Gate Status Monitoring / / Connection External Alarm Reset Button (Shut-Off Alarm) CLOSG cell Connection Gate Operators Communication LEDs V Power for Matrix 1 Battery in Use LED Motor Motion LEDs External / Key Switch - Optional Adjustments Open and Close Limits Release Handle Clamp Reverse Sensor () Maintenance Qualified gate operator technician End user/home owner Megatron Primary Wiring Schematics Megatron Secondary Wiring Schematics Manual Release Electronic Gate Open / Close - Optional Audible Alarm Replacement Parts List Warranty Megatron options / unique features Gate Tamper Feature Gate Disable Feature Event History Download Maximum Controls LLC. All rights reserved. No part of this manual may be reproduced in any means: graphics, electronics or mechanical, including photocopying without the expressed written permission of the publisher. Materials components and specifications are subject to change without notice. 1

4 max megatron specifications Class of Operation - Class I, II, III, IV Gate Type - Vehicular Swing Gate Max Gate Weight / Length: - Megatron 100/100HP - 1 ft or ft - Megatron 1 ft or ft - Megatron FAST - 1 ft gate per operator 100HP (High Profile) NOTE: The Megatron FAST is LY available for installation on bi-parting gates (dual operators). A single gate operator CANNOT be used. 90 Opening Time: - Megatron 100/100HP/00-16 selectable speeds from approximately 11. sec to 0 sec depending on the weight and length of the gate. - Megatron FAST - 16 selectable speeds from approximately 6 sec to 1 sec depending on the weight and length of the dual gates. Cycles per Hour AC Input Power - Continuous Battery Back-Up Cycles (BC-7 Battery Module-7 Amp/Hr Batteries fully charged): - Approximately 0 cycles NOTE: The number of gate cycles using LY battery back-up power will vary depending on the weight of the gate, the gate length, the operating condition of the gate hardware, temperature and the amount of charge the batteries have at the beginning of the battery power only operation. 100HP 100HP Input AC Power - Switchable: 11VAC or 0VAC single phase Motor - VDC Brushless (equivalent to 1 HP AC motor) Operating Temperature: - F to 18 F (-0 C to 70 C) Entrapment Protection: - Type A Inherent ( sensor) - Inputs for NORMALLY (N.C.) Type B1 (photo cell) and Type B (sensing edge) important safety information WARNG To reduce the risk of injury or death: 1. READ AND FOLLOW ALL STRUCTIS.. Never let children operate or play with gate controls. Keep the remote control away from children.. Always keep people and objects away from the gate. NO E SHOD CROSS THE PATH OF THE MOVG.. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.. Use the emergency release only when the gate is not moving. 6. KEEP S PROPERLY MATAED. Read the owner s manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE STRUCTIS

5 ul model classifications AUTHORIZED PERSNEL LY CLASS I Residential Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith. CLASS III Industrial/Limited Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for uses in an industrial location, loading dock area or other location not intended to service the general public. URITY CLASS II Commercial/General Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public. CLASS IV Restricted Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a guarded industrial location or buildings such as airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. ul required entrapment protection Gate Type Swing Gate Slide Gate Class I & II A, B1*, B*, C, D A, B1*, B*, D Class III & IV A, B1*, B*, C, D, E A, B1*, B*, D, E The same type of device shall not be utilized for entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions. A combination of one Type B1 for one direction and one Type B for the other direction is the equivalent of one device for the purpose of complying with the requirements of entrapment protection areas. A - Inherent entrapment protection system. B1 - Provision for connection of a non-contact sensor (photoelectric sensor or the equivalent). B - Provision for connection of a contact sensor (edge device or the equivalent). * B1 and B means of entrapment protection must be MITORED. C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An audio alarm.

6 ul compliant installation requirements A Install the gate operator only when: 1 The operator is appropriate for the construction of the gate and the usage Class of the gate, All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.8 m) above the ground to prevent a -1/ inch (7. mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position, All exposed pinch points are eliminated or guarded, and Guarding is supplied for exposed rollers. B The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. D The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate. E For gate operators utilizing Type D protection: 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving, A gate operator shall additionally be provided with a placard that is marked in letters at least 1/-in (6.-mm) high with the word WARNG and the following statement or the equivalent: Moving Gate Has Potential of Inflicting Injury or Death - Do Not Start Gate Unless Path is Clear. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and No other activation device shall be connected. F Controls intended for user activation must be located at least six feet (6 ) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. G The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. H A minimum of two () WARNG SIGNS shall be installed, one on each side of the gate where easily visible. I For gate operators utilizing a non-contact sensor: 1 See instructions on the placement of non-contact sensors for each Type of application, Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. J For a gate operator utilizing a contact sensor: 1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions. 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (1 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. 7 One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).

7 Pedestrians must use separate entrance. intended use of swing gate operator The operator is intended for use on a VEHICAR swing gate LY. It is intended to be used WITH appropriate entrapment protection safety devices and in-ground vehicle loop detection system. Entrapment Protection cell: Helps guard against the opening gate from entrapment. Closing Gate Protection cell: Helps protect the gate operator from accidentally closing on vehicles in the gate s closing path. Warning Signs: Should be installed on both sides of gate area and easily visible. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Entrapment Area In-Ground Loops: Help protect the gate operator from accidentally opening and/or closing on vehicles in the gate s path. Bottom of Gate Sensing Edge: Helps protect the gate operator from accidentally opening and/or closing on vehicles in the gate s path. Pedestrians MUST use a separate entrance. The gate operator IS NOT intended to be used on a PEDESTRIAN gate. 6 or More Sensing Edge on Bottom of Gate: If the bottom of gate is 6 inches or higher above the ground, then a sensing edge should be installed for safety. NOTE: Entrapment protection sensors MUST be MITORED and NORMALLY (N.C.)

8 Motor OverLoad 1 1 Sensitivity 16 LED 1 1 /SOLAR JOG JOG Motor OverLoad 1 1 Sensitivity 16 LED 1 1 /SOLAR JOG JOG TO CTROLLER 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL M SPEED OVERLOAD M CLAMP SLIPPG -LE -LE Made in USA 1VDC VDC TO CTROLLER RADIO 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL M SPEED OVERLOAD M CLAMP SLIPPG -LE -LE Made in USA 1VDC VDC RADIO MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge DISABLE Tamper EDGE ALARM 1V V USE MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge DISABLE Tamper EDGE ALARM 1V V USE installation Read and understand this entire manual before installation. Check with the local building department prior to installing this gate operator to comply with local building code requirements. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates should not open into public access areas. Gate Operator position The gate must be properly installed and work freely in both directions prior to installation of the gate operator. Gate Bracket Pivot Point Closed Position A Hinge Pivot Point Illustrations not to scale Measurement Guidelines A Should be at least 1/ the gate length. Longer than E Locked Position B 1 minimum for open gate clearance ( thick gate). C Distance A minus 17 inches (A - 17 = C). D & E Arm should be 90 from gate when and in the straight locked position when. Arm Pivot Point Long Arm Short Arm D E Shorter than D Edge B 1 Min Edge 1 Concrete Pad 8 1 C 0 8 Operator Pivot Point Open Position Outside Property Min Inside Property Hood Gate Frame DO NOT allow arm to touch hood in gate s position. TOO MUCH STRESS is put on the arm in this position during gate operation. Preferred arm position is 90 from open gate. See page 10 for arm position options and connection to gate. NOTE: If dimension between gate and wall is 0 to then compact installation is necessary, see page 1. Wall 6

9 Motor OverLoad JOG JOG 1 / Battery Replace Battery BOARD TEST Battery Sensitivity LED Battery Error PUTS ALARM V Edge Entrap Limit SW Edge -LE MC-00 Motor Controller TAIL Tamper EDGE 1VDC VDC M M 1.Sec -LE -LE 7 Amp FUSE On Off installation recommended Gate Operator layout Use for VEHICAR traffic LY. Pedestrians MUST use a separate entrance. Install appropriate entrapment protection safety devices for the G direction and CLOSG direction of gate cycling. Install in-ground and loops. Install a GROUNDG ROD within 10 ft of operator. An Optional loop can be installed if desired. NOTE: E Entrapment protection sensor MUST installed or operator will NOT function. It MUST be MITORED and NORMALLY (N.C.) Run wiring to OPERATOR. Sensing Edge Mount on end of gate. Support Bar 1 Edge AUTOMATIC / CTROLS 1 TIME Sec RS-8 - RS PWR V - PACK Power In Illustration not to scale 1/ RADIO Battery Voltage E 1/ F SPEED OVERLOAD CLAMP SLIPPG BC-7 Battery Module DISABLE ALARM 1V USE WARNG: For continued protection against fire, replace only with the same type and rating of fuse. AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d incendie, utiliser un fusible de mêmes type et caractéristiques nominales. 11VAC A max CLOSG cell Beam 1 High Beam Height Just Above Gate Operator Secure gate operator to concrete pad with six (6) 1/ x (min) sleeve anchors. G cell Beam x 0 Pad In-Ground Loops Conduit Area 1 x 8.. Ground Rod G cell Min 6 Above Ground CLOSG cell From Safety Loop Center Loop Support Bar Input AC Power (Required) Safety Loop Exit Loop (Optional) 7

10 1 TAIL BOARD 1VDC VDC 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M ALARM PACK SPEED OVERLOAD CLAMP SLIPPG M -LE -LE Battery Voltage E 1/ F / Replace Battery Battery EDGE ALARM 1V Power In BC-7 Battery Module TEST Battery Battery Error V Tamper USE installation layout and arm height of 100/00/FAST or 100hp The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. See Gate Operator Position on page 6 for operator position and Arm Connection to Gate on page 10. Conduit Guidelines and Suggestions (See page 7) REQUIRED - AC input power wire. REQUIRED - Entrapment protection (photocell and/or sensing edge). See page 1. Normally open photocell. See page 1. In-ground loop wires. See page 1. Illustration not to scale Support Bar: See below Arm MUST be installed level. Secure gate operator to concrete pad with six (6) 1/ x (min) sleeve anchors. 1/ 100/00/FAST = 100HP =. 19 =100/00/FAST 7. =100HP RS-8 - RS PWR V - RADIO PUTS DISABLE Ground Level Optional Input Power Note: VDC low voltage power wires can be run from a remote power supply ( Magic Box) to power the gate operator if desired. See page 11 for more information. Check local building codes in your area for depth of concrete before installation. Concrete Pad 6 Above Ground Conduit Input Power Concrete Depth Note: The heavier the gate, the deeper the concrete pad should be. At least two feet recommended for heavier gate. Support Bar A support bar should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending. Support Bar YES Gate Bracket Support Bar Too High & Not Long Enough NO 8

11 Motor OverLoad 1 1 Sensitivity 16 LED 1 1 /SOLAR ALARM PACK Battery Voltage E 1/ F / Battery JOG JOG Replace Battery Made in USA TEST Battery Power In Edge BC-7 Battery Module Battery Error MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge TO CTROLLER PACK Motor OverLoad 1 AUTOMATIC / CTROLS TAIL M BOARD 1VDC VDC 1 1 Sensitivity 16 LED 1 1 /SOLAR JOG JOG Edge TO CTROLLER PACK 1 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL M SPEED OVERLOAD M CLAMP SLIPPG -LE -LE Made in USA 1VDC VDC 1 TIME 1.Sec Sec ALARM PACK RADIO SPEED M Battery Voltage E 1/ F / Battery RADIO OVERLOAD CLAMP SLIPPG -LE -LE Replace Battery TEST Battery EDGE ALARM 1V Power In DISABLE V BC-7 Battery Module Battery Error MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge Tamper EDGE ALARM 1V DISABLE V Tamper USE USE dual Gate Operators installation The gates must be properly installed and work freely in both directions prior to the installation of the dual gate operators. See Gate Operator Position on page 6 for operator positions and previous page for arm height. Secure EACH gate operator to concrete pad with six (6) 1/ x (min) sleeve anchors. 1/ Secondary Operator NO Matrix 1 Conduit Guidelines and Suggestions REQUIRED - Run AC input power wire to EACH gate operator. REQUIRED - Entrapment protection (photocell and/or sensing edge) to EACH Corresponding OPERATOR. (see below & page 1) Normally open photocell to the OPERATOR. (page 1) In-ground loop wires to the OPERATOR. (page 1) BOARD Arms MUST be installed level. Support Bars: See bottom of page 8. Primary Operator Matrix 1 Illustration not to scale RS-8 - RS PWR V - PUTS RS-8 - RS PWR V - PUTS 6 Above Ground Conduit Input Power Check local building codes in your area for depth of concrete before installation. To Matrix 1 input Conduit Concrete Depth Note: The heavier the gates, the deeper the concrete pads should be. At least two feet recommended for heavier gates. 6 Above Ground Conduit Input Power Optional Input Power Note: VDC low voltage power wires can be run from a remote power supply ( Magic Boxes) to power the gate operators if desired. See page 11 for more information. Each entrapment protection device MUST be connected to corresponding gate operator. Normally Open cell NOT Entrapment Protection Illustrations not to scale Outside Property Entrapment Protection Sensing Edges To Matrix 1 Input Entrapment Area to Secondary Operator MC-00 Motor Controller to Secondary Operator MC-00 Motor Controller Secondary Operator NO Matrix 1 Inside Property to Primary Operator MC-00 Motor Controller Primary Operator Matrix 1 to Primary Operator MC-00 Motor Controller Entrapment Area Entrapment Protection cell Entrapment Protection cell 9

12 MC-00 Motor Sensitivity JOG JOG Motor Controller OverLoad -LE Edge Entrap LED 1 Limit SW Edge /SOLAR TO CTROLLER 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL Tamper M EDGE ALARM 1V 1VDC SPEED OVERLOAD M VDC CLAMP SLIPPG -LE USE -LE Made in USA RADIO Edge DISABLE V 1 TAIL BOARD 1VDC VDC 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M ALARM PACK SPEED OVERLOAD CLAMP SLIPPG M -LE -LE Battery Voltage E 1/ F / Replace Battery Battery EDGE ALARM 1V Power In BC-7 Battery Module TEST Battery Battery Error V Tamper USE MC-00 Motor Sensitivity JOG JOG Motor Controller OverLoad -LE Edge Entrap LED 1 Limit SW Edge /SOLAR TO CTROLLER 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL Tamper M EDGE ALARM 1V 1VDC SPEED OVERLOAD M VDC CLAMP SLIPPG -LE USE -LE Made in USA RADIO Edge DISABLE V RS-8 - RS PWR V - PUTS arm position options Retro-Fit Arm Option RADIO When replacing an existing gate operator, the arm may not be able to conform to the preferred arm position (90 from gate in open position). The positions illustrated below can be acceptable as long as the gate operator cycles smoothly and there is NO gate hesitation when gate starts cycling in either direction. Gate in Opened Position 90 Gate in Opened Position DISABLE 90 installation High Traffic Arm Option Gates in Closed Position Arms are NOT installed in ED position. If a vehicle tries to push gates open, arms will give when NOT in the locked position and allow gates to move without damaging the gate operators. The tamper relay will be activated for a few seconds which will trigger a camera or alarm system if desired. arm connection to gate After you re satisfied testing the arm in the FL and FL positions, weld gate bracket and arm. Illustrations not to scale Full Closed Locked Position Full Open Preferred arm position is 90 from open gate. weld completely around arm tubing and gate bracket. Release Handle Clamp Re-Attach Arm to Operator: Limit pin MUST fit into slot in bottom of release handle clamp directly under the arm when re-attaching arm to operator. Arm MUST be installed level. Arm Slot Limit Tabs Limit Pin Gate Bracket Assembly Arm Elbow Assembly 10

13 ! 0V 1 TAIL BOARD 1VDC VDC 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M ALARM PACK SPEED OVERLOAD CLAMP SLIPPG M -LE -LE Battery Voltage E 1/ F / Replace Battery Battery EDGE ALARM 1V Power In BC-7 Battery Module TEST Battery Battery Error V Tamper USE installation optional remote power supply kit - max magic box A remote power supply is for installations where it is too costly or difficult to trench a 11/0 VAC power line to the operator but instead run a low voltage power line to the operator. A Magic Box Kit (sold separately) is required to remotely install a Remote Megatron Toroid box. Install the Magic Box near the 11 VAC or 0 VAC input AC power source, up to 1000 ft away from gate operator. NOTE: A Magic Box kit is required for EACH gate operator when using dual gate operators. Operator Magic Box Near Power Source Magic Box Kit Power/Solar In Connector Wire Nuts Sold Separately Cover PS- WARNG HIGH VOLTAGE disconnect power before servicing unit SUPPLY Cabinet Remote Toroid 1 Amp Box Made in USA FUSE 7 AMP AC Select Input Voltage: 11VAC or 0VAC warranty VOED if label is REMOVED Distance - See table below -Wires, VDC Low Voltage Power See page 0 for Magic Box wiring instructions. At Magic Box 11/0 VAC Power Source SUPPLY PS- Remote Toroid 1 Amp Box WARNG! HIGH VOLTAGE disconnect power before servicing unit Made in USA FUSE 7 AMP AC Select Input Voltage: 11VAC or 0VAC warranty VOED if label is REMOVED At Gate Operator RADIO DISABLE 0V Conduit not supplied Input Power High Voltage To Operator VDC Low Voltage Input AC Power RS-8 - RS PWR V - PUTS VDC Low Voltage Power Ground Level Conduit Gate Weight 100 lbs 00 lbs Max Wire Distance - Wire Gauge 00 ft - 1AWG 00 ft - 10AWG 1000 ft - 10AWG 1000 ft - 8AWG Concrete Pad VDC Low Voltage Power 11

14 Motor OverLoad /SOLAR 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL M SPEED OVERLOAD M CLAMP SLIPPG -LE -LE Made in USA 1VDC VDC RADIO 1 1 Sensitivity 16 LED 1 1 JOG JOG TO CTROLLER MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge DISABLE V Tamper EDGE ALARM 1V USE 1 TAIL BOARD 1VDC VDC 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M ALARM PACK SPEED OVERLOAD CLAMP SLIPPG M -LE -LE Battery Voltage E 1/ F / Replace Battery Battery EDGE ALARM 1V Power In TEST Battery Battery Error BC-7 Battery Module V Tamper USE Motor OverLoad 1 1 Sensitivity 16 LED 1 1 /SOLAR JOG JOG TO CTROLLER 1 PACK 1 TIME 1.Sec Sec AUTOMATIC / CTROLS TAIL M SPEED OVERLOAD M CLAMP SLIPPG -LE -LE Made in USA 1VDC VDC RADIO MC-00 Motor Controller -LE Edge Entrap 1 Limit SW Edge DISABLE Tamper EDGE ALARM 1V V USE installation compact installation only Use compact installation arm measurements when area between the gate and wall is 0 min to. DO NOT use these arm measurements for a standard installation. (For standard installation, see page 6) Open Position Gate Bracket Pivot Point Hinge Pivot Point Illustrations not to scale Closed Position 6. Edge 0 min to Entrapment Area Wall It is necessary to protect against the entrapment that could occur with this type of installation. (See entrapment protection on page 1) Long Arm Short Arm Arm Elbow Pivot Point. Operator Pivot Point Cut the standard arms down to 8 meet the shorter measurements Cut Long Arm Cut 10 Short Arm 0 8 Edge Cut 0 solar - Optional Refer to Solar application guide. Solar Power Kit: MUST be used when using solar power. Sold separately. Solar Panel Volt Solar Power Kit Solar Panel: must be mounted facing south. It must get full sunlight throughout the day, NO shadow obstructions. Solar Kit Power/Solar In Connector Wire Nuts Solar Panel Electronics Box RS-8 - RS PWR V - RADIO PUTS DISABLE Solar Panel Electronics Box 1

15 installation entrapment protection Install photocells and sensing edges to help protect against entrapment during cycling of the gate (entrapment protection). See pages & for wiring instructions. E entrapment protection sensor MUST be installed and connected to on MC-00 motor controller or operator will NOT function. Entrapment protection sensors MUST be MITORED and NORMALLY (N.C.). Top View Outside Property cell (Normally, NOT entrapment protection) to PHOTO input on Matrix 1. Beam: or LESS from gate. Gate Closed Wireless Transmitter 9 V battery operated transmitter mounted on gate. WIRELESS OPTI NOTE: Refer to the instruction sheet that comes with the receiver/transmitter for more specific wiring and mounting instructions when using wireless option. Conduit Illustrations not to scale Entrapment Protection photocell to MC-00 motor controller, Monitored. Normally (N.C.) Entrapment Protection Sensing Edge to MC-00 motor controller, Monitored. Mount on end of gate. Normally (N.C.) Inside Property Gate Open Entrapment Area Dual Gate Operators NOTE: Run EACH entrapment protection sensor to each corresponding OPERATOR S MC-00 motor controller. See page 9. Side View Entrapment Protection Sensing Edge, Install along entire edge of gate. cell (Normally, NOT entrapment protection) Gate Open Entrapment Protection cell, Install just above gate operator. Beam Height: 1 Normal 7. Max. 1

16 1VDC VDC M M -LE OVERLOAD 1.Sec installation in-ground loops Install in-ground loops to help protect vehicles from a moving gate. See pages & 9 for wiring instructions. Outside Property ft Safety Loop ft ft Refer to loop maunufacturer s instructions to determine specific loop dimensions. It is recommended that a licenced installer perform this work. Illustration not to scale Inside Property ft Conduit Side View of Saw Cut Lead Wires Sealant Backer Rod 1 1/ Typical Center Loop Loop Wire Saw Cut 1/ Saw Cut Pavement ft Safety Loops Are placed on each side of the gate to prevent the gate from closing on a vehicle in it s path. They will stop or reverse the cycling of the gate while a vehicle is in or near the gate s pathway. Center Loop Will LY HOLD the gate in the Full Open Position when a vehicle is on the center loop. However, it WILL NOT stop or reverse the gate once it starts to close. Exit Loop Automatically opens the gate for exiting vehicles without having to use a radio transmitter (remote control). The exit loop can be placed a minimum of feet away from the safety loop or far enough away from the gate so it has opened by the time the vehicle approaches it. Inside Property LOOP ft Lead Wires LOOP LOOP Safety Loop ft min. Exit Loop LOOP ft Safety loops need to be wired in series. Outside Property Lead Wires Loop lead wires are twisted 6 twists per foot minimum inside conduit. Matrix 1 Wiring 1 TAIL 1 TIME Sec AUTOMATIC / CTROLS RADIO SPEED -LE CLAMP SLIPPG DISABLE EDGE ALARM 1V V Tamper USE 1

17 installation install warning signs A minimum of two () WARNG SIGNS shall be installed, one on each side of the gate where easily visible. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. 1

18 LED M Limit SW 1 Edge Wiring operator Check with local building department prior to installing any permanent wiring on this gate operator. Make sure all wiring complies with local code requirements. Gate Operator Overview 1VDC VDC RADIO 1 Battery Voltage E 1/ F TAIL / Replace Battery Battery Motor OverLoad BOARD RS-8 - RS PWR V - BC-7 Battery Module TEST Battery Battery Error SPEED Sensitivity AUTOMATIC / CTROLS ALARM JOG JOG 1 TIME 1.Sec Sec M 6 OVERLOAD CLAMP SLIPPG -LE 9 -LE DISABLE V PACK Tamper EDGE PUTS ALARM 1V USE Edge 8 -LE Edge Power In Motor Controller Entrap MC Amp FUSE WARNG: For continued protection against fire, replace only with the same type and rating of fuse. AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d incendie, utiliser un fusible de mêmes type et caractéristiques nominales. On Off 11VAC A max Megatron Toroid Box: AC power management for the AC input power to the gate operator. See pages 19, 0 &. Release Handle Clamp: Manually move the gate when handle is raised. See page 1. Audible Alarm: Sounds when there is a problem with cycling the gate. Push the button on the Matrix 1 or an externally mounted Alarm Reset button to shut-off alarm. Alarm can sound every time operator is cycled using LY battery back-up power when turned, See page. VDC Brushless Motor (6 million cycles) MC-00 Motor Controller: Manages entrapment protection devices and operator motor reversing sensitivity adjustment. See pages 19, 0,, &. BC-7 Battery Module: Battery Back-Up and DC power management for the gate operator. See below. Limit Tabs: Adjusts the and gate positions. See page. Limit Switch Box: Contains the limit switches. Gate operator will NOT function when limit switch box is not connected. See page. Matrix 1: Manages control panel operations. Manages inputs/outputs, loops and reports problems with gate operator. See Matrix 1 Section starting on page. BC-7 Battery Module connect to before use IMPORTANT /SOLAR 1 /SOLAR TO CTROLLER Battery Voltage E 1/ F Battery Pack 6 BC-7 Battery Module 7 / Replace TEST Battery Battery Battery Battery Error 1 Plug: MUST be plugged into port Before use. /SOLAR Port: Megatron Toroid box connection. Battery Voltage LEDs: Show amount of battery power available. LEDs are always when using AC power. Test battery button must be pressed to show battery power when using battery power LY. / Battery Button: IMPORTANT: Battery power automatically turns when Megatron Toroid Box AC Switch is turned. To turn ALL to operator: 1. Turn AC Switch on Megatron Toroid Box. Battery power remains.. WAIT for 1 seconds.. Press and HOLD (approx. seconds) the RED / button until BC-7 LEDs turn, then release button. LEDs will turn. Replace Battery LED: Replace battery when lit. 6 TEST Battery Button: Press to show amount of battery power available when using battery power LY (Battery voltage LEDs will light respectively). 7 Battery Error LED: Lights when there is a battery connection problem. Make sure battery plug #1 is plugged into port or there is no damaged or loose wires. 16

19 Wiring operator Gate Operator System Overview continued MC-00 Motor Controller Motor OverLoad 1 1 Sensitivity External Open/Close Key Switch, Dual Gate Operators See page. 1 A B C LED JOG JOG Normally Closed (N.C.) cell-monitored AND/OR Normally Closed (N.C.) Sensing Edge-Monitored Sensors MUST be 1V Power powered by MC-00 PWR 1V input. D -Monitored Entrapment protection sensors power to PWR 1V. E Edge F G I -LE Edge 1 Limit SW Edge L Motor Controller Entrap H J K MC-00 M Normally Closed (N.C.) cell AND/OR Normally Closed (N.C.) Sensing Edge Sensors MUST be powered by MC-00 PWR 1V input. Inputs & MUST be LEARNED before they will MITOR a connected sensor. See next page. Edge Normally Closed (N.C.) cell AND/OR Normally Closed (N.C.) Sensing Edge Sensors MUST be powered by MC-00 PWR 1V input. A OVERLOAD LED: Excessive current being drawn by motor when lit. B LED: sensor has been activated when lit. C Sensitivity Knob: 16 selectable sensitivity settings of sensor. D Sensitivity LED: sensitivity reached when lit. E Jog / Buttons: Push and HOLD buttons accordingly to move the gate (release the button to stop gate). WARNG: Avoid moving gate while using Jog buttons. F PUTS: /RT: Can connect to an External Open/Close Key switch. Connect a single key switch to control dual gate operators, See page. : Low Voltage Common connection. : Connects to a NORMALLY (N.C.) Sensing Edge and/or photocell. MITORED input. Multiple sensors can be connected. Edge : Connects to a NORMALLY (N.C.) Sensing Edge and/or photocell. Input MUST be LEARNED before it can MITOR connected sensor (see next page). Multiple sensors can be connected. : Connects to a NORMALLY (N.C.) Sensing Edge and/or photocell. Input MUST be LEARNED before it can MITOR connected sensor (see next page). Multiple sensors can be connected. G Matrix On Line LED: Gate operator is successfully communicating with Matrix 1 when lit. H Limit SW On Line LED: Limit Switch Sensors are successfully communicating with MC-00 Motor Controller when lit. I LED: sensor has been activated when lit. J Edge LED: Edge sensor has been activated when lit. LED will light up during LEARNG mode when sensor is connected, see next page. K cell LED: cell sensor has been activated when lit. LED will light up during LEARNG mode when sensor is connected, see next page. L Entrap LED: Edge1/Edge/cell inputs have been activated when lit. M Power LED: Low voltage power is connected when lit. N RS-8 Input: Factory wired for Primary operator. Wire to Matrix 1 for Secondary operator LY. O V Power Input: V Power for Matrix 1 LY. P 1V Entrapment Protection Sensor Power Out: 1V Power that ALL Entrapment protection sensors MUST use PWR 1V power. DUAL OPERATORS NOTE: Connect EACH photocell/sensing edge to the corresponding gate operator. See page 9. Matrix 1 Board Entrapment Protection Sensors Power Out not used - not used - - PWR 1V - RS-8 - RS PWR V - O N P ALARM MC-00 Motor Controller PACK PUTS Power In RS-8 Secondary Operator to Matrix 1 input Jumper UNUSED Entrapment Protection Inputs or a fault will occur. Normally Closed (N.C.) Sensor Wire Example: Inputs & are NOT used and MUST be jumpered to. 1 17

20 1VDC VDC M OVERLOAD -LE 1.Sec Wiring operator Gate Operator System Overview continued MC-00 Motor Controller Continued Motor OverLoad Sensitivity LED JOG JOG Edge 1 -LE Edge Entrap 1 Limit SW Edge MC-00 Motor Controller Entrapment Protection Input Descriptions: is MITORED and does NOT need to be learned before normal operation. Edge and will NOT monitor a connected sensor until the LEARN mode has been run on them. LEARN inputs & to MITOR sensors: All NORMALLY (N.C.) sensors MUST be wired to & inputs and PWR 1V input BEFORE the LEARN mode is performed. All unused inputs MUST be jumpered to. 1. Press and HOLD the & buttons at the same time on the Matrix 1 until a beep is heard. This indicates that the LEARN mode has begun. Learn mode lasts for minutes indicated by continual beeping. If learn mode has NOT been confirmed in minutes, then MC-00 will revert back to it s previous setting (factory setting does NOT monitor inputs). 1 RADIO TAIL 1 TIME Sec AUTOMATIC / CTROLS SPEED CLAMP SLIPPG -LE DISABLE EDGE ALARM 1V V Tamper USE. While beeping is heard, check on front of the MC-00 and make sure all connected Motor Sensitivity JOG JOG sensor LEDs are lit. If an LED is not on and it should be, OverLoad wiring to sensor is bad and must be corrected. When all LEDs are that should be, Press the button 1 again within minutes to end the learn mode, stop the beeping and confirm that the 1 16 LED sensors are MITORED Example shows that sensors are MITORED on inputs Edge and cell. Edge -LE Edge Entrap 1 Limit SW Edge MC-00 Motor Controller 18

21 AC 11 Motor OverLoad Sensitivity LED JOG JOG PACK Edge Entrap -LE Power In ALARM 1VDC VDC M PUTS 1 Limit SW Edge M -LE -LE / Replace Battery Battery TEST Battery Battery Error V 1.Sec Wiring operator input ac power Wire input AC power wire to the Megatron Toroid box as shown. Choose either 11V or 0V setting on input AC power selector switch. NOTE: AC power wire is required for EACH gate operator when using dual gate operators. AC Power LED CAUTI: Make sure circuit breaker is from incoming AC input wire BEFORE wiring! Input AC Power Selector Switch Megatron Toroid Box 0V 11 Select Input Voltage 11VAC or 0VAC Megatron Toroid Back of Megatron Toroid Box CAUTI: If power selector switch is set for 11V but input power is actually 0 V, 7 Amp Fuse will blow. AC Input AC Power Options Single Phase 11VAC Only 11VAC Set to 11V 11V DANGER HIGH VOLTAGE! Line (Black) 7 Amp Fuse Power Terminal Line (Black) 7 Amp FUSE WARNG: For continued protection against fire, replace only with the same type and rating of fuse. AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d incendie, utiliser un fusible de mêmes type et caractéristiques nominales. On Off 11VAC A max DO NOT TURN AT THIS TIME. AC Power Gang Box Power Terminal WARNG! HIGH VOLTAGE disconnect power before servicing unit 11 OR 0VAC Power Wire Neutral (White) Neutral (White) Single Phase 0VAC Only 0VAC Set to 0V 0V Chassis (Green) Chassis (Green) IMPORTANT NOTE: Make sure there are NO exposed bare wires at the power terminal connection. Operator MUST be Properly GROUNDED Ground within 10 ft of operator. Any of the Chassis Grounds can be used. They are located next to the gear reducer. DO NOT remove any existing green ground wires. WARNG connect chassis to ground rod for lightning protection Proper grounding of this gate operator is a requirement for LIGHTNG PROTECTI in lightning prone areas. To be effective, ground connections should be made with a minimum 1 AWG, 600 volt insulated wire to a ground point within 10 feet of the gate operator. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a grounding rod. Chassis Ground Grounding Rod Select Input Voltage 11VAC or 0VAC Megatron Toroid BOARD RS-8 - RS PWR V - Edge 1 TAIL MC-00 Motor Controller SPEED AUTOMATIC / CTROLS Battery Voltage E 1/ F 1 TIME Sec RADIO OVERLOAD CLAMP SLIPPG Tamper DISABLE EDGE ALARM 1V BC-7 Battery Module USE NOTE: Consult city codes for AC line wiring. Beware of existing underground services. 19

22 DO NOT TURN AT THIS TIME. Wiring operator low voltage remote power supply kit - optional A Magic Box Kit (sold separately) is required to remotely install a Remote Toroid 1 Amp box at the AC power source. Plug in Remote Toroid 1 Amp connector to Power In at Magic Box. Wire input AC power to the Toroid 1 Amp box. Choose either 11V or 0V setting on input AC power selector switch. Run V low voltage wires (not included) from the Magic Box connection to the gate operator and wire to /SOLAR connector (Polarity Matters!). Remove the Remote Toroid 1 Amp connector from the BC-7 battery module /SOLAR port. Plug the Magic Box /SOLAR connector into the /SOLAR port. At Magic Box DANGER HIGH VOLTAGE! NOTE: A Magic Box kit is required for EACH gate operator when using dual gate operators. Ground within 10 ft of Box Power In PS- SUPPLY Made in USA FUSE 7 AMP AC Remote Toroid 1 Amp Connector WARNG! HIGH VOLTAGE disconnect power before servicing unit Remote Toroid 1 Amp Box Grounding Rod Power Terminal Wires Line (Black) Neutral (White) Chassis (Green) Select Input Voltage: 11VAC or 0VAC warranty VOED if label is REMOVED 0V Input AC Power Input AC Power Selector Switch CAUTI: If power selector switch is set for 11V but input power is actually 0 V, 7 Amp Fuse will blow. NOTE: Consult city codes for AC line wiring. CAUTI: MAKE SURE CIRCUIT BREAKER IS AT SOURCE BEFORE WIRG Ground IMPORTANT NOTE: Maximum Control s remote power supply technology does NOT utilize the battery power from the BC-7 Battery Module during NORMAL gate operation. Battery power is reserved for back-up power LY when an AC power failure occurs. As a result, battery life is NOT shortened. This low voltage system can CTUOUSLY cycle the gate during NORMAL gate operation, perfect for high traffic gate applications. Input Power High Voltage 11 VAC or 0 VAC Input AC Power Pos + To Operator VDC Low Voltage V Wires 10 AWG Minimum /SOLAR Port /SOLAR Connector (Included in kit). Pos + Polarity Matters! V Low Voltage Wire in Conduit to Gate Operator Magic Box MUST be Properly GROUNDED IMPORTANT: Magic Box and Gate Operator MUST EACH be Properly GROUNDED. Proper grounding is a requirement for LIGHTNG PROTECTI in lightning prone areas. To be effective, ground connections should be made with a minimum 1 AWG, 600 volt insulated wire to a ground point within 10 feet of the Magic Box and gate operator. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a grounding rod. NOTE: Beware of existing underground services. /SOLAR connect to before use IMPORTANT /SOLAR TO CTROLLER Battery Voltage E 1/ F Battery Pack / Replace TEST Battery Battery Battery BC-7 Battery Module Battery Error BC-7 Battery Module At Gate Operator 0

23 Wiring operator solar power connection - optional Refer to Solar application guide. TO CTROLLER Battery Pack NOTE: Cover solar panel from sunlight BEFORE wiring plug to solar panel to prevent a shock from occurring. Max Solar Power Kit (Sold separately) Pos + Red Polarity Matters! Black connect to before use IMPORTANT Connect to /SOLAR /SOLAR /SOLAR Battery Voltage E 1/ F BC-7 Battery Module / Replace TEST Battery Battery Battery Battery Error BC-7 Battery Module (Approximately 0 cycles using only battery power) 1

24 Sensitivity LED ALARM Limit SW 1 -LE Edge Entrap 1VDC VDC M M OVERLOAD 1.Sec Wiring operator secondary operator to matrix 1 Unplug -Pin plug from the bottom of the MC-00 motor controller and connect RS-8 wires as shown below. Primary Gate Operator Matrix TIME Sec AUTOMATIC / CTROLS Motor OverLoad TAIL Tamper NOTE: The Alarm Shut-Off is located on the Primary gate operator LY. There is NO alarm shut-off button on the secondary gate operator. Secondary Gate Operator (NO Matrix 1) Battery Voltage E 1/ F / Replace Battery Battery /SOLAR BC-7 Battery Module TEST Battery Battery Error JOG JOG MC-00 BOARD RS-8 - RS PWR V - not used - not used - - PWR 1V - -Pin Plug TO CTROLLER Battery Pack To MC Battery Pack PACK Edge PUTS Edge Power In Motor Controller To MC MC-00 WARNG: For continued protection against fire, replace only with the same type and rating of fuse. AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d incendie, utiliser un fusible de mêmes type et caractéristiques nominales. 7 Amp FUSE On Off 11VAC A max RADIO SPEED CLAMP SLIPPG -LE -LE -LE ALARM 1V V EDGE USE -Pin Plug NO V to Matrix 1 BOARD RS-8 - RS PWR V - PWR 1V - - Secondary Operator MC-00 not used - not used - ALARM PACK Wires to Matrix 1 PUTS Power In Connect () three RS-8 wires from the DARY operator s MC-00 motor controller to the Matrix 1 -. Pos to Pos Neg to Neg Gnd to Gnd DO NOT connect PWR V. AWG Min. -conductor twisted pair, shielded cable Secondary Primary Wires to Matrix 1

25 M ALARM PACK Power In Wiring operator turn on/off operator power Operator should have Input AC power wired to Toroid Box, V & RS-8 wired between Matrix 1 and MC-00. TURN. Certain LEDs should normally turn accordingly: A Located on back of box. 1 7 Amp FUSE WARNG: For continued protection against fire, replace only with the same type and rating of fuse. AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d incendie, utiliser un fusible de mêmes type et caractéristiques nominales. On Off 11VAC A max Turn AC Power Switch Battery power automatically turns. A DO NOT CYCLE OPERATOR AT THIS TIME Megatron Toroid Box AC LED: Normal - Turns. Error - Not. Check AC power. 7 Amp Fuse blown. Replace fuse. Input AC selector switch MUST be set to CORRECT input AC power. /SOLAR IMPORTANT connect to before use /SOLAR 1 1VDC VDC RADIO Motor OverLoad Sensitivity TAIL 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M BOARD 1 1 RS-8 - RS PWR V - JOG LED JOG not used not used - PWR 1V - TO CTROLLER Battery Voltage E 1/ F J Battery Pack / Replace Battery Battery Edge Ce l SPEED G F TEST Battery Battery Error OVERLOAD CLAMP SLIPPG -LE -LE BC-7 Battery Module K H C -LE 1 MC-00 Motor Contro ler Edge Entrap Limit SW Edge PUTS D DISABLE J K I B EDGE ALARM 1V V Tamper E USE MC-00 Motor Controller B C D LED: Normal - Turns. Error - Not. Check plug on bottom of MC-00. Matrix On-Line LED: Normal - Turns. Error - Not. Check RS-8 wiring to Matrix 1. Limit SW On-Line LED: Normal - Turns. Error - Not. Check plug. Matrix 1 BC-7 Battery Module E F G H I LED: Normal - Turns. Error - Not. Check V wiring from MC-00 Primary. Motor On-Line LED: Normal - Turns. Error - Not. Check RS-8 wiring to Primary MC-00. Limit SW On-Line LED: Normal - Turns. LED: Normal - Turns either LED according to switch setting. Error - Not. Check plug on bottom of MC-00. USE LED: Normal - Not. Error - Flashes on and off. Battery not plugged in to port on BC-7 Battery Module. VOLTAGE LEDs: Normal - LEDs turn - Fully charged batteries. Batteries need charging - LEDs will turn on in sequence until batteries are fully charged. Batteries are NOT necessary when AC power is available. LED: Normal - Not. Error - Turns. Battery not plugged in to port. To turn ALL : 1. Turn AC Switch on Megatron Toroid Box. Battery power remains.. WAIT for 1 seconds.. Press and HOLD (approx. seconds) the RED / button until BC-7 LEDs turn, then release button. LEDs will turn.

26 matrix 1 matrix 1 Overview matrix 1 1 Battery Back-Up Mode - Page 6 Primary Gate - Page 6 Maglock - Page 9 Gate Tamper - Page 0 In-Ground Loop Connection - Page 9 6 Anti Tailgate - Page 7 7 Loop Detectors - Page 9 8 Entrapment LEDs - Page 0 9 Close Timer - Page 6 10 Plug & Plug Error LED - Page 0 11 Alarm / Alarm Reset Input - Page 0, & 1 Radio Power - Page 8 1 Partial Open - Page 1 1 Stop Button (Alarm Shut-Off) - Page 0, & 1 OBD Port Black Box - Page 8 16 Selectable Gate Speed Control - Page 6 17 & Motor Overload LEDs - Page 18 Gate Status - Page 19 Radio Relay - Page 8 0 Emergency Vehicle/Max Open Inputs - Page 0 1 Normal Opening Devices - Page Close cell - Page & Operators Communication LEDs - Page & // Connection - Page External Alarm Reset Connection - Page Gate Disable - Page 1 6 Matrix 1 Power - Page 7 Battery in Use - Page VDC VDC RADIO 19 TAIL 1 TIME 1.Sec Sec AUTOMATIC / CTROLS M SPEED OVERLOAD M CLAMP SLIPPG LE -LE 1 1 Back 17 8 DISABLE Tamper EDGE 10 ALARM 1V 18 V 6 USE 7 11 A B C Gate in Motion Alarms - Page 8 Single Pass Anti-Tailgate - Page 7 Radio Safety Pause - Page 9 A Mode 0 Mode 1 Single Pass Anti-Tailgate B When turned ; After a vehicle clears the Safety Loop, a closing gate will PAUSE if a second vehicle attempts to tailgate. The second vehicle must then back off the safety loop for the gate to continue closing. A new radio signal will open the gate. Gate in Motion Alarms Motion Alarm sounds before gate moves and continues until gate stops Mode 0 Motion Alarms Beeper Alert sounds in Battery Back-Up Mode while gate is in motion Mode 1 Beeper Alert Radio Safety Pause C When turned "" a moving gate will pause if a radio input signal is received. The next radio signal causes the gate to continue in the original direction. MADE USA

MAX phantom 2000 / FAST

MAX phantom 2000 / FAST www.max.us.com SENSORS REQUIRED FOR 325 2016 CFORMS TO STD 325 CLASS I, II, III, IV CERTIFIED TO CAN/CSA STD C22.2 NO. 247 High Traffic Commercial Brushless DC Low Profile Swing Gate Operators 4009963

More information

MAX 1500 / MAX Residential/Commercial Brushless DC Slide Gate Operators Made in USA. Installation and Owners Manual.

MAX 1500 / MAX Residential/Commercial Brushless DC Slide Gate Operators Made in USA. Installation and Owners Manual. www.max.us.com CFORMS TO STD 325 CLASS - I, II, III, IV CERTIFIED TO CAN/CSA STD C22.2 NO. 247 Residential/Commercial Brushless DC Slide Gate Operators Made in USA 4009963 1500 / 2200 Installation and

More information

Eagle Access Control Systems, Inc. / (800) / (3)

Eagle Access Control Systems, Inc. / (800) /  (3) UL Listings IMPORTANT SAFETY INSTRUCTIONS A. WARNING To reduce the risk of injury or death: 1) READ AND FOLLOW ALL INSTRUCTIONS. 2) Never let children operate or play with gate controls. Keep the remote

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator Installation/Owner s Manual Model 652-080 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 100-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the

More information

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard Installation/Owner s Manual Model 6524-380 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 4100-018 Revision A or higher. Entrapment Protection must be provided for the gate

More information

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator gate area. 53382 HP MODEL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 9024-080 Use this manual for circuit board 4100-010 Revision AA or higher.

More information

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Series 6500 Installation/Owner s Manual Series 00 Use this manual for circuit board 0-00 Revision E or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT function. Vehicular Swing

More information

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Series 6500 Installation/Owner s Manual Series 00 Use this manual for circuit board 0-08 Revision A or higher. Vehicular Swing Gate Operator Entrapment Protection must be provided for the gate system where the risk

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL HP 53382 Read owner s manual and safety instructions. Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST

More information

Installation/Owner s Manual

Installation/Owner s Manual 53382 HP Read owner s manual and safety instructions. Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision K or higher. For operators manufactured July 2011and later. Series

More information

Installation/Owner s Manual Series 9000

Installation/Owner s Manual Series 9000 HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Series 9000 Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI

More information

Actuator Arm and Control Box Mounting

Actuator Arm and Control Box Mounting Actuator Arm and Control Box Mounting To wire this operator and complete the installation, refer to a specific control box Wiring/Owner s manual. 6002 Vehicular Swing Gate Operator 6002-065-Y-1-13 Copyright

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS 582 HP OPEN CLOSE Wiring / Owner s Manual Use this manual for circuit board 02-010 Revision A or higher. 115 VAC Control Boxes for 6002, 600, 600 and 600 gate operators 02-065-E-5-12 CFORMS TO ANSI/UL-25

More information

Installation/Owner s Manual Series 9150

Installation/Owner s Manual Series 9150 Read owner s manual and safety instructions. CLASS HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Series 90 Use this manual for circuit board 0-00

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 58 HP CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-010 Revision A or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT function.

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 8 HP DOORKING CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL HP 53382 DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision K or higher. For operators manufactured July 2011and later. Series

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL 8 HP DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate

More information

Installation/Owner s Manual Model 9100

Installation/Owner s Manual Model 9100 CLASS MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI

More information

Installation/Owner s Manual Series 9500

Installation/Owner s Manual Series 9500 MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand

More information

Installation/Owner s Manual Model 9050

Installation/Owner s Manual Model 9050 8 CLASS HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Use this manual for circuit board 70-00 Revision AA or higher. Vehicular Slide Gate

More information

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL Model HCTDCU HCTDCU Motor Unit HCT08 8 Foot Rail HCT10 10 Foot Rail HCT12 12 Foot Rail THIS PRODUCT

More information

Installation/Owner s Manual 9245

Installation/Owner s Manual 9245 CFORMS TO ANSI/UL-35 5338 VEHICULAR GATE OPERATOR CLASS HP MODEL SERIAL MAX GATE LOAD Do not stand in gate path or walk through path while gate is moving. Read owner s manual and safety instructions. CFORMS

More information

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator MODEL 8 Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator Use this manual for circuit board 0-00 Revision D or higher. 9000-0-K-7- WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH

More information

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator MODEL 8 Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator Use this manual for circuit board 0-00 Revision D or higher. 9000-0-N-- WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH

More information

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator CLASS MODEL 8 DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Vehicular Slide Gate Operator Use this manual for circuit board 60-00 Revision A or higher. 900-06-Z-- WARNING MOVING GATE

More information

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series ontrol Systems, Inc. www.eagleoperators.com Operator installation and instructions for the Eagle-200 and Eagle-100 Series. UL325 and UL991

More information

Solar Control Box for

Solar Control Box for CLASS MODEL SERIAL 5338 HP D OOR KIN G OPEN CLOSE Wiring / Owner s Manual Use this manual for circuit board 430-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator

More information

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator Installation/Owner s Manual Model 6524-081 Solar Powered Vehicular Swing Gate Operator Use this manual for circuit board 4100-010 Revision AA or higher. 6524-066-S-5-18 For AC Power, See 6524-065 AC Power

More information

Solar Control Box for

Solar Control Box for CLASS MODEL SERIAL 53382 HP CLOSE Wiring / Owner s Manual Use this manual for circuit board 4302-010 Revision N or higher. Solar Control Box for 6002, 6003, 6004 and 6400 gate operators 4302-067-N-2-13

More information

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Owner s Manual. Model 9150 Vehicular Slide Gate Operator Owner s Manual Model 9150 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9150-065 REV D, 5/07

More information

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator MODEL 582 Installation/Owner s Manual Model 9024-081 Use this manual for circuit board 4100-010 Revision D or higher. 9024-066-H-1-15 Solar Powered Solar Powered Vehicular Slide Gate Operator WARNING MOVING

More information

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING CERTIFIED TO CAN/CSA C22.2 NO. 247 53382 VEHICULAR GATE OPERATOR CLASS HP MODEL SERIAL AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate

More information

Solar Powered. Solar Powered. Installation/Owner s Manual Model Solar Powered Vehicular Slide Gate Operator

Solar Powered. Solar Powered. Installation/Owner s Manual Model Solar Powered Vehicular Slide Gate Operator gate area. employed. 53382 CLASS HP MODEL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 9024-081 Use this manual for circuit board 4100-010 Revision

More information

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC Owner s Manual 50 Overhead Gate Operator EXIT PART REVERSE TIME DELAY REV SENSE OPEN REV SENSE CLOSE 2 3 4 5 6 7 8 2 3 4 PUSH TO OPERATE technician use only GATE FORCED NO NC Copyright 205 DoorKing, Inc.

More information

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing Vehicular Swing Gate Operator Nice Gate Operators Titan 912L The Titan 912L Gate Operator is intended for use with vehicular swing gates. The Titan 912L Gate Operator can be used in Class I, Class II and

More information

UGP-712 Vehicular swing gate operator

UGP-712 Vehicular swing gate operator Vehicular swing gate operator INSTALLATION INSTRUCTION MANUAL PLATINUM ACCESS SYSTEMS Installation Instructions & Safety Information Manual Vehicular Swing Gate Operator Class I, Class II, Class III, and

More information

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS Ramset_Man300.qxd 4/18/05 1:06 PM Page 1 FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS Ramset_Man300.qxd 4/18/05 1:06 PM Page 2 www.ramsetinc.com Ramset_Man300.qxd 4/18/05 1:06 PM Page 3 TABLE OF CONTENTS

More information

Sliding Gate Opener User s Manual

Sliding Gate Opener User s Manual Gat Model: Sliding Gate Opener User s Manual GA2500 Gate1Access, LLC. www.gate1access.com Email: support@gate1access.com 1 Thank you for purchasing GA2500 gear rack drive sliding gate opener. We are sure

More information

RAMSET

RAMSET RAMSET TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular Gate

More information

gate operator class categories and examples

gate operator class categories and examples BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 1 BLSL840 BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 2 BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 3 Installation Instructions & Safety Information

More information

Actuator Arm and Control Box Mounting

Actuator Arm and Control Box Mounting Actuator Arm and Control Box Mounting To wire this operator and complete the installation, refer to a specific control box Wiring/Owner s manual. 6005 Vehicular Swing Gate Operator Entrapment Protection

More information

FSW 900 Swing Gate Operator

FSW 900 Swing Gate Operator FSW 900 Swing Gate Operator UL325 - UL991 FAAC International Inc. Headquarter & East Coast Operations 3160 Murrell Rd Rockledge, FL 32955 Tel. 800 221 8278 www.faacusa.com FAAC International Inc. West

More information

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator 53382 HP Installation/Owner s Manual 600 Vehicular Swing Gate Operator Use this manual for circuit board 302-010 Revision A or higher. 600-065-L-7-10 Standard Control Box WARNING Deluxe Control Box CERTIFIED

More information

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev Rev 060202 Instruction Manual Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators C No. 545327 US TABLE OF CONTENTS Important Safety Requirements & Instructions.......................................1,2

More information

Owner s Manual. Series 6300 Vehicular Swing Gate Operators

Owner s Manual. Series 6300 Vehicular Swing Gate Operators Owner s Manual Series 6300 Vehicular Swing Gate Operators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6300-065 REV E,

More information

RAM TABLE OF CONTENTS

RAM TABLE OF CONTENTS TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular Gate Operators...4

More information

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 1 FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 2 www.ramsetinc.com R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 3 TABLE

More information

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

Owner s Manual. Model 9300 Vehicular Slide Gate Operator Owner s Manual Model 9300 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9300-065 Rev C 6/03

More information

RAMSET RAM

RAMSET RAM www.ramsetinc.com TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular

More information

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

Owner s Manual. Model 9100 Vehicular Slide Gate Operator Owner s Manual Model 9100 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9100-065 REV C, 1/04

More information

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9 TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW...1 USAGE CLASS...2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS...2 SAFETY INSTALLATION INFORMATION...3 GATE CONSTRUCTION INFORMATION...4 INTRODUCTION

More information

FOR CLASS I VEHICULAR GATE OPERATORS

FOR CLASS I VEHICULAR GATE OPERATORS FOR CLASS I VEHICULAR GATE OPERATORS www.ramsetinc.com TABLE OF CONTENTS Important Safety Requirements & Instructions.... 1 Responsibilities of Installers and Technicians. 2 Important Safety Requirements

More information

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

Owner s Manual. Model 9310 Vehicular Slide Gate Operator Owner s Manual Model 930 Vehicular Slide Gate Operator DoorKing, Inc. 20 Glasgow Avenue Inglewood, California 9030 U.S.A. Phone: 30-65-0023 Fax: 30-6-586 www.doorking.com P/N 930-065 Rev D 5/05 Copyright

More information

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators Owner s Manual Models 6050 and 6100 Vehicular Swing Gate Operators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6050-065

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO T E VIKING 10 GATE OPE ATO

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO T E VIKING 10 GATE OPE ATO INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO T E VIKING 10 GATE OPE ATO CLASS I, CLASS II, CLASS III, AND CLASS IV Residential and Commercial Vehicular Slide Gate Operator VIKING BLUE ENABLED SOLAR

More information

Installation/Owner s Manual 1601 / 1602

Installation/Owner s Manual 1601 / 1602 CFORMS TO ANSI/UL-325 CERTIFIED TO CAN/CSA C22.2 NO. 247 CLASS HP MODEL SERIAL 53382 VEHICULAR GATE OPERATOR DoorKing, Inc., Inglewood, CA Installation/Owner s Manual 60 / 602 Barrier Gate Operator Use

More information

MODEL MSW Medium Duty Swing Gate Operator

MODEL MSW Medium Duty Swing Gate Operator INSTALLATION AND OWNER S MANUAL MODEL MSW Medium Duty Swing Gate Operator UL 325 and UL 991 Listed 22-1/4 16-1/2 19-1/2 16 20'' LENGTH X 14-3/4'' WIDTH 2 O.D. PIPE (BY OTHERS) Serial #: Date Installed:

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING H-10 GATE OPERATOR

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING H-10 GATE OPERATOR INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING H-10 GATE OPERATOR CLASS I, CLASS II, CLASS III, AND CLASS IV Residential and Commercial Vehicular Slide Gate Operator The H-10 gate operator

More information

Installation/Owner s Manual 1601 / 1602

Installation/Owner s Manual 1601 / 1602 CFORMS TO ANSI/UL-325 CERTIFIED TO CAN/CSA C22.2 NO. 247 CLASS HP MODEL SERIAL 53382 VEHICULAR GATE OPERATOR DoorKing, Inc., Inglewood, CA Installation/Owner s Manual 60 / 602 Barrier Gate Operator Use

More information

PowerMaster Model SG

PowerMaster Model SG PowerMaster Model INSTALLATION MANUAL CAREFULLY READ THIS ENTIRE MANUAL FIRST BEFORE PROCEEDING! LEAVE THIS MANUAL WITH END USER FOR FUTURE REFERENCE AFTER INSTALLATION IS COMPLETE (LAST PAGE SHOULD BE

More information

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR. CLASS I Residential Vehicular Slide Gate Operator

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR. CLASS I Residential Vehicular Slide Gate Operator INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR NEW IMAGE CLASS I Residential Vehicular Slide Gate Operator The K-2 gate operator has the capacity to operate slide gates

More information

Vehicular Gate Operator Class I, Class II, Class III, and Class IV

Vehicular Gate Operator Class I, Class II, Class III, and Class IV BLSL2250 Manual_Layout 1 5/8/2015 4:49 PM Page 1 BLSL2250 BLSL2250 Manual_Layout 1 5/8/2015 4:49 PM Page 3 Installation Instructions & Safety Information Manual BLSL2250 Vehicular Gate Operator Class I,

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q-7 GATE OPERATOR

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q-7 GATE OPERATOR INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q-7 GATE OPERATOR CLASS II, CLASS III, AND CLASS IV Heavy-Duty Commercial Vehicular Slide Gate Operator The Q-7 gate operator has the capacity

More information

SPECIFICATIONS AND WARNINGS SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one

More information

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR NEW IMAGE CLASS I, CLASS III, AND CLASS IV Residential Vehicular Slide Gate Operator The K-2 gate operator has the capacity

More information

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Model RSW12U THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. This model is for use on vehicular

More information

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR MODEL LA500 LA5001PKGDC Single Arm Package LA500DC Primary 24 VDC Actuator Arm for single swing gate applications LA500DCS Secondary 24 VDC

More information

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL 10-04-00 CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist...

More information

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD CTROLLER BOARD GL MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR MODEL SW490 HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date INTENDED FOR PROFESSIAL

More information

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR CTROLLER BOARD GL MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR MODEL SW490 HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date INTENDED FOR PROFESSIAL

More information

MODEL D-SBG Single Arm Barrier Gate Operator

MODEL D-SBG Single Arm Barrier Gate Operator INSTALLATION AND OWNER S MANUAL MODEL D-SBG Single Arm Barrier Gate Operator UL 325 and UL 991 Listed WITH NITRO BOARD (SEE SUPPLEMENTAL MANUAL) Serial #: Date Installed: Your Dealer: READ THIS MANUAL

More information

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR CTROLLER BOARD GL MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date MODEL SL575 IS FOR VEHICULAR PASSAGE GATES LY AND IS NOT INTENDED

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING G-5 GATE OPERATOR SINGLE AND DUAL GATE SYSTEMS

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING G-5 GATE OPERATOR SINGLE AND DUAL GATE SYSTEMS INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING G-5 GATE OPERATOR SINGLE AND DUAL GATE SYSTEMS CLASS I, CLASS II, CLASS III, AND CLASS IV Residential and Commercial Vehicular Swing Gate

More information

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR MODEL LA412 LA4121PKGDC Single Arm Package LA412DC Primary 12 VDC Actuator Arm for single swing gate applications LA412DCS Secondary 12 VDC Actuator Arm

More information

MODEL SL585 MODEL SL595 HEAVY DUTY SLIDE GATE OPERATOR HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

MODEL SL585 MODEL SL595 HEAVY DUTY SLIDE GATE OPERATOR HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD CTROLLER BOARD GL MODEL SL585 HEAVY DUTY SLIDE GATE OPERATOR YEAR WARRANTY Serial # (located on electrical box cover) Installation Date MODEL SL595 HEAVY DUTY, HARSH ENVIRMENT SLIDE GATE OPERATOR MODELS

More information

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS MODEL RSG RESIDENTIAL SLIDE GATE OPERATOR TABLE OF CONTENTS PowerMaster Installation Manual RESIDENTIAL SLIDE GATE OPERATOR UL 325 AND UL 991 LISTED UL R Important Safety Information.....3 UL Installation

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING F-1 GATE OPERATOR

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING F-1 GATE OPERATOR INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING F-1 GATE OPERATOR CLASS I, II, III AND IV Commercial and Residential Vehicular Swing Gate Operator The F-1 gate operator has the capacity

More information

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR CTROLLER BOARD GL MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date MODEL SL575 IS FOR VEHICULAR PASSAGE GATES LY AND IS NOT INTENDED

More information

MODEL D-WBG Wishbone Arm Barrier Gate Operator

MODEL D-WBG Wishbone Arm Barrier Gate Operator INSTALLATION AND OWNER S MANUAL MODEL D-WBG Wishbone Arm Barrier Gate Operator UL 325 and UL 991 Listed WITH NITRO BOARD (SEE SUPPLEMENTAL MANUAL) Serial #: Date Installed: Your Dealer: READ THIS MANUAL

More information

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2S GATE OPERATOR. CLASS I Solar Residential Vehicular Slide Gate Operator

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2S GATE OPERATOR. CLASS I Solar Residential Vehicular Slide Gate Operator INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING K-2S GATE OPERATOR NEW IMAGE CLASS I Solar Residential Vehicular Slide Gate Operator The K-2S Viking Solar Gate Operator has the capacity

More information

Installation/Owner s Manual 1603

Installation/Owner s Manual 1603 CFORMS TO ANSI/UL-325 CERTIFIED TO CAN/CSA C22.2 NO. 247 CLASS HP MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD 53382 VEHICULAR GATE OPERATOR DoorKing, Inc., Inglewood, CA Installation/Owner s Manual

More information

Please DO NOT Touch me!... Unless you are an Authorized Service Technician!

Please DO NOT Touch me!... Unless you are an Authorized Service Technician! V 0503 TABLE OF CONTENTS N T Attention: This handbook is exclusively for qualified installation personnel, and assistance and/or maintenance service. - The performances indicated in this handbook are valid

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6S GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6S GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6S GATE OPERATOR CLASS I Residential Vehicular Swing Gate Operator The R-6S Viking Solar Swing Gate Operator is capable of handling gates

More information

copyright 2008 chamberlain professional products -

copyright 2008 chamberlain professional products - copyright 2008 chamberlain professional products - www.liftmaster.com TABLE OF CONTENTS Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users

More information

6002 swing gate actuator - installation guide

6002 swing gate actuator - installation guide 600 swing gate actuator - installation guide 600 Residential Swing Gate Actuator Installation Guide DKS DoorKing, Inc. 0 Glasgow, Avenue Inglewood, Ca. 900 0.645.00 0.64.586 fax info@doorking.com www.doorking.com

More information

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 OPERATION 31 INTRODUCTION 5 ACCESSORY WIRING 34 INSTALLATION 9 MAINTENANCE 36

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 OPERATION 31 INTRODUCTION 5 ACCESSORY WIRING 34 INSTALLATION 9 MAINTENANCE 36 TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW...1 USAGE CLASS...2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS...2 SAFETY INSTALLATION INFORMATION...3 GATE CONSTRUCTION INFORMATION...4 INTRODUCTION

More information

Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users

Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users #352 Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users Overview Automatic vehicular gate operating systems provide convenience and security

More information

Heavy Duty Commercial Linear Gate Operator

Heavy Duty Commercial Linear Gate Operator MAX SUPER ARM 2300 Heavy Duty Commercial Linear Gate Operator Moves heavy gates up to 20 High traffic high wind Self-locking, Mag Lock unnecessary Overload clutch release on 3 ton impact MAX AC control

More information

IQ Gate Systems. IQ-500 Installation And Instruction Manual UL 325 and UL 991 Compliant.

IQ Gate Systems. IQ-500 Installation And Instruction Manual UL 325 and UL 991 Compliant. IQ Gate Systems IQ-500 Installation And Instruction Manual www.iqgatesystems.com 1-801-455-7961 UL 325 and UL 991 Compliant Revision B IQ Gate Systems: IQ-500 Installation IQ-500 Capacities: Swing gates

More information

Heavy Duty Commercial Linear Gate Operator

Heavy Duty Commercial Linear Gate Operator MAX SUPER ARM 2300 Heavy Duty Commercial Linear Gate Operator Moves heavy gates up to 20 High traffic high wind Self-locking, Mag Lock unnecessary Overload clutch release on 3 ton impact MAX AC control

More information

vehicular gate operator installation instructions and safety information revision B1 february 2007 CLASS I, CLASS II, CLASS III and CLASS IV

vehicular gate operator installation instructions and safety information revision B1 february 2007 CLASS I, CLASS II, CLASS III and CLASS IV revision B1 february 2007 installation instructions and safety information LISTED 18TC UL 325 UL 991 vehicular gate operator L-3 CLASS I, CLASS II, CLASS III and CLASS IV PARTS DIAGRAM 5 6 25 15 22 24

More information

Installation Instructions and Safety Information Manual: Vehicular Gate Operator Class I, Class II, Class III, and Class IV

Installation Instructions and Safety Information Manual: Vehicular Gate Operator Class I, Class II, Class III, and Class IV BLSW814 Manual_Layout 1 2/10/2014 5:04 PM Page 1 BLSW814 BLSW814 Manual_Layout 1 2/10/2014 5:04 PM Page 2 BLSW814 Manual_Layout 1 2/10/2014 5:04 PM Page 3 Installation Instructions & Safety Information

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR OWNER'S MANUAL Model SL930 is for vehicular passage

More information

OWNER S MANUAL GP-SL050. With Inherent UPS Battery Back-up System

OWNER S MANUAL GP-SL050. With Inherent UPS Battery Back-up System OWNER S MANUAL GP-SL050 Residential Duty Slide Gate Operator With Inherent UPS Battery Back-up System TWO 12VDC, U1, 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED. DO NOT Install This Operator Without Roller

More information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6 GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6 GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6 GATE OPERATOR CLASS I Residential Vehicular Swing Gate Operator The R-6 swing gate operator is capable of handling gates up to 900 lbs.

More information

VIKING. installation instructions and safety information

VIKING. installation instructions and safety information VIKING installation instructions and safety information VIKING BLUE ENABLED SOLAR EFFICIENT OPERATION class I, class II, class III, and class IV residential and commercial vehicular slide gate operator

More information