MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

Size: px
Start display at page:

Download "MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS"

Transcription

1 MARTINDALE ELECTRIC Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: F: web: LITIN2000 ISSUE 5 06/2004 IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL MARTINDALE ELECTRIC Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: F: sales@martindale-electric.co.uk web: LITIN2000 ISSUE 5 06/2004 IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

2

3 10. LIMITED WARRANTY Martindale Electric Company Ltd warrant instruments and test equipment manufactured by them to be free from defective material or factory workmanship and agree to repair or replace such products which, under normal use and service, reveal the defect to be the fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation under this warranty is limited to repairing, replacing or making refund of any instrument or test equipment which proves to be defective within twenty four months from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorised persons in any way so as, in our sole judgement, to degrade their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence or accident or which have had the serial numbers altered, defaced or removed. Accessories not of our manufacture, used with this product, are not covered by this warranty. To register a claim under the provisions of this warranty, return the instrument to Martindale Electric Company Ltd, Metrohm House, Penfold Trading Estate, Watford, WD24 4YY. Upon our receipt and inspection of the product we will advise you as to the outcome of your claim. ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD OF 24 MONTHS, AND THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser, his employees, or others, and the remedies provided for in this warranty are expressly in lieu of any other liability Martindale Electric Company Ltd may have including incidental or consequential damages. Martindale Electric Company Ltd reserves the right to discontinue models at any time, or change specification, price or design, without notice and without incurring any obligation. TABLE OF CONTENTS 1. SYMBOLS 2. SAFETY RULES 3. DESCRIPTION 4. OPERATING INSTRUCTIONS 5. SPECIFICATION 5.1 ELECTRICAL 5.2 OUTPUT CHARACTERISTICS 5.3 MECHANICAL 5.4 ENVIRONMENTAL 6. FUSED LEADS 7. SPARES & ACCESSORIES 8. REPAIRS 9. CLEANING 10. LIMITED WARRANTY LIMITED WARRANTY Martindale Electric Company Ltd warrant instruments and test equipment manufactured by them to be free from defective material or factory workmanship and agree to repair or replace such products which, under normal use and service, reveal the defect to be the fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation under this warranty is limited to repairing, replacing or making refund of any instrument or test equipment which proves to be defective within twenty four months from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorised persons in any way so as, in our sole judgement, to degrade their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence or accident or which have had the serial numbers altered, defaced or removed. Accessories not of our manufacture, used with this product, are not covered by this warranty. To register a claim under the provisions of this warranty, return the instrument to Martindale Electric Company Ltd, Metrohm House, Penfold Trading Estate, Watford, WD24 4YY. Upon our receipt and inspection of the product we will advise you as to the outcome of your claim. ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD OF 24 MONTHS, AND THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser, his employees, or others, and the remedies provided for in this warranty are expressly in lieu of any other liability Martindale Electric Company Ltd may have including incidental or consequential damages. Martindale Electric Company Ltd reserves the right to discontinue models at any time, or change specification, price or design, without notice and without incurring any obligation TABLE OF CONTENTS 1. SYMBOLS 2. SAFETY RULES 3. DESCRIPTION 4. OPERATING INSTRUCTIONS 5. SPECIFICATION 5.1 ELECTRICAL 5.2 OUTPUT CHARACTERISTICS 5.3 MECHANICAL 5.4 ENVIRONMENTAL 6. FUSED LEADS 7. SPARES & ACCESSORIES 8. REPAIRS 9. CLEANING 10. LIMITED WARRANTY

4 1 SYMBOLS 7. SPARES AND ACCESSORIES Caution (risk of electric shock). Test Leads, Standard Kit: Fused Leads: Fuse 5x20mm 500mA 250V HBC FAST BLOW: Battery 1.5V IEC LR6, Manganese Alkaline TL47 TLl57 FUSE REPAIRS Caution (refer to instruction manual). NOTE: Before returning the instrument for repair please check that the following are in correct working order: 1) The condition of the batteries and that they are inserted correctly in the battery compartment. 2) The test leads are not faulty. 2 SAFETY RULES Equipment protected by DOUBLE INSULATION or REINFORCED INSULATION CAUTION RISK OF ELECTRIC SHOCK DISCONNECT TEST LEADS BEFORE OPENING TESTER 3) If the fuse is either blown or not fitted correctly the buzzer will sound and the display will read over range when the continuity range is selected, with the test leads disconnected. Please return the tester to: Martindale Electric Company Ltd Metrohm House Penfold Trading Estate Imperial Way Watford WD24 4YY 9 CLEANING Clean the instrument case with an anti-static cleaner and wipe with a dry cloth SYMBOLS 7. SPARES AND ACCESSORIES Caution (risk of electric shock). Test Leads, Standard Kit: Fused Leads: Fuse 5x20mm 500mA 250V HBC FAST BLOW: Battery 1.5V IEC LR6, Manganese Alkaline TL47 TLl57 FUSE REPAIRS Caution (refer to instruction manual). NOTE: Before returning the instrument for repair please check that the following are in correct working order: 1) The condition of the batteries and that they are inserted correctly in the battery compartment. 2) The test leads are not faulty. 2 SAFETY RULES Equipment protected by DOUBLE INSULATION or REINFORCED INSULATION CAUTION RISK OF ELECTRIC SHOCK DISCONNECT TEST LEADS BEFORE OPENING TESTER 3) If the fuse is either blown or not fitted correctly the buzzer will sound and the display will read over range when the continuity range is selected, with the test leads disconnected. Please return the tester to: Martindale Electric Company Ltd Metrohm House Penfold Trading Estate Imperial Way Watford WD24 4YY 9 CLEANING Clean the instrument case with an anti-static cleaner and wipe with a dry cloth

5 5.3 MECHANICAL Size: Material: Weight: Display: Sockets: Test leads: 190 x 90 x 54mm Polycarbonate/ABS 0.5kg(less carrying case) Custom Liquid Crystal Display 4mm shrouded 1m long leads fitted with non retractable shrouded plugs and shrouded crocodile clips This tester has been designed with your safety in mind. However, no design can completely protect against incorrect use. Electrical circuits can be dangerous and/or lethal when lack of caution or poor safety practices are used. When using this tester to monitor high voltages turn off the power before connecting the tester. Where possible, do not touch the tester or its leads when the power is on. 5.4 ENVIRONMENTAL Turn off the power before disconnecting the tester. Operating Temperature: 0º to +40ºC Storage Temperature: -20ºC to +70ºC Humidity: 90% at 40ºC 6. FUSED LEADS CAUTION READ THE MANUAL These instruments have been designed to comply with BS EN 61010, and are safe to use with the two leads, clips and probes that are provided as standard. HSE guidance GS38 recommends the use of fused leads. These can be purchased as accessories if desired. Read this Instruction Manual carefully and completely. Voltages within the capability of this tester can be hazardous. Follow the instructions in this Manual for every measurement. Read and understand the general instructions before attempting to use this tester. SAFETY CHECK Before using the tester check the condition of the batteries and fuse. NOTE: The condition of the fuse can be checked by selecting the continuity range and if the buzzer sounds the fuse is either blown or not inserted properly in the fuse holder. Battery and fuse replacement are described in the operating instructions MECHANICAL Size: Material: Weight: Display: Sockets: Test leads: 190 x 90 x 54mm Polycarbonate/ABS 0.5kg(less carrying case) Custom Liquid Crystal Display 4mm shrouded 1m long leads fitted with non retractable shrouded plugs and shrouded crocodile clips This tester has been designed with your safety in mind. However, no design can completely protect against incorrect use. Electrical circuits can be dangerous and/or lethal when lack of caution or poor safety practices are used. When using this tester to monitor high voltages turn off the power before connecting the tester. Where possible, do not touch the tester or its leads when the power is on. 5.4 ENVIRONMENTAL Turn off the power before disconnecting the tester. Operating Temperature: 0º to +40ºC Storage Temperature: -20ºC to +70ºC Humidity: 90% at 40ºC 6. FUSED LEADS CAUTION READ THE MANUAL These instruments have been designed to comply with BS EN 61010, and are safe to use with the two leads, clips and probes that are provided as standard. HSE guidance GS38 recommends the use of fused leads. These can be purchased as accessories if desired. Read this Instruction Manual carefully and completely. Voltages within the capability of this tester can be hazardous. Follow the instructions in this Manual for every measurement. Read and understand the general instructions before attempting to use this tester. SAFETY CHECK Before using the tester check the condition of the batteries and fuse. NOTE: The condition of the fuse can be checked by selecting the continuity range and if the buzzer sounds the fuse is either blown or not inserted properly in the fuse holder. Battery and fuse replacement are described in the operating instructions

6 Double check the switch setting, and lead connections before making measurements. Are you following instructions? Disconnect the tester or turn off the power before changing switch positions. When replacing fuses use only specified types and insert correctly in the fuse holder. When changing the battery, fuse, or removing the cover to access the internal circuitry, always disconnect the test leads. DON T TOUCH General Safety: LVD: Meets BS EN EMC: Meets BS EN BS EN Battery: 6 off 1.5V, AA IEC LR6 Manganese-Alkaline Fuse: 500mA, 5 x 20mm, HBC, 250V Fast Blow 5.2 OUTPUT CHARACTERISTICS Don t touch exposed wiring, connection or other live parts of an electrical circuit. If in doubt, check the circuit first for voltage before touching it. Turn off the power to a circuit before connecting test probes to it. Be sure there is no voltage present before you touch the circuit. Do not use cracked or broken test leads. Do not use in wet conditions. V MΩ Double check the switch setting, and lead connections before making measurements. Are you following instructions? Disconnect the tester or turn off the power before changing switch positions. When replacing fuses use only specified types and insert correctly in the fuse holder. When changing the battery, fuse, or removing the cover to access the internal circuitry, always disconnect the test leads. DON T TOUCH General Safety: LVD: Meets BS EN EMC: Meets BS EN BS EN Battery: 6 off 1.5V, AA IEC LR6 Manganese-Alkaline Fuse: 500mA, 5 x 20mm, HBC, 250V Fast Blow 5.2 OUTPUT CHARACTERISTICS Don t touch exposed wiring, connection or other live parts of an electrical circuit. If in doubt, check the circuit first for voltage before touching it. Turn off the power to a circuit before connecting test probes to it. Be sure there is no voltage present before you touch the circuit. Do not use cracked or broken test leads. Do not use in wet conditions. V MΩ

7 Insulation (MΩ) (Standard, 200MΩ) Autorange: 0-20MΩ in steps of 0.01MΩ and 0MΩ - 200MΩ in steps of 0.1MΩ MΩ nominal Test Voltage: Model IN20001: 500V DC -0+20% (Current) with a load of 0.5MΩ (1mA) HIGH VOLTAGE IS DANGEROUS Always start with the power turned off. Be sure there is no voltage present before making connections to the circuit. Before disconnecting the tester, turn the circuit off and wait for the meter to return to zero. Battery Consumption: (Nominal) Model IN2003: 250V DC -0+20% with a load of 0.25MΩ 500V DC -0+20% with a load of 0.5MΩ or 1000V DC -0+20%with a load of 1MΩ ±2% of reading ±1 digit up to 20MΩ ±3% of reading ±1 digit up to 100MΩ ±10% of reading ±1 digit up to 200MΩ 100mA: 250V DC into 0.25MΩ 100mA: 500V DC into 0.5MΩ 200mA: 1000V DC into 1MΩ SAFETY IS NO ACCIDENT! THIS INSTRUMENT SHOULD ONLY BE USED BY A COMPETENT, SUITABLY TRAINED PERSON. REMEMBER SAFETY IS NO ACCIDENT! Insulation (MΩ) (Standard, 200MΩ) Autorange: 0-20MΩ in steps of 0.01MΩ and 0MΩ - 200MΩ in steps of 0.1MΩ MΩ nominal Test Voltage: Model IN20001: 500V DC -0+20% (Current) with a load of 0.5MΩ (1mA) HIGH VOLTAGE IS DANGEROUS Always start with the power turned off. Be sure there is no voltage present before making connections to the circuit. Before disconnecting the tester, turn the circuit off and wait for the meter to return to zero. Battery Consumption: (Nominal) Model IN2003: 250V DC -0+20% with a load of 0.25MΩ 500V DC -0+20% with a load of 0.5MΩ or 1000V DC -0+20%with a load of 1MΩ ±2% of reading ±1 digit up to 20MΩ ±3% of reading ±1 digit up to 100MΩ ±10% of reading ±1 digit up to 200MΩ 100mA: 250V DC into 0.25MΩ 100mA: 500V DC into 0.5MΩ 200mA: 1000V DC into 1MΩ SAFETY IS NO ACCIDENT! THIS INSTRUMENT SHOULD ONLY BE USED BY A COMPETENT, SUITABLY TRAINED PERSON. REMEMBER SAFETY IS NO ACCIDENT!

8 3. DESCRIPTION The IN2000 Series digital insulation and continuity testers are designed to carry out testing in accordance with International standards, including BS7671. There are two variants available, the 500V only IN2001 and the 250/500/1000V IN2003. The instruments are powered by six 1.5 volt manganese alkaline batteries type LR6. The instruments are supplied in a carrying case which contains the instruction book, test leads and clips. The carrying case has been designed to allow the tester to be operated in the case. The models have a push to operate and turn to latch test button on the insulation ranges as standard. On completion of an insulation test, a latched test button has to be manually released to discharge the installation under test. In the interest of safety the user should be aware of this. 5. SPECIFICATION IN2001/IN2003 Series 5.1 ELECTRICAL Voltage V~ Input Impedance: Continuity (Ω) Autorange: Test Voltage: Short Circuit Current: Battery Consumption: 0-500V AC ±2% of Full Scale 16MΩ nominal 0-20Ω in steps of 0.01Ω and 0-200Ω in steps of 0.1Ω Ω nominal 4V DC min 200mA min ±2% of reading ±1 digit 230mA nominal Buzzer Current Consumption: Operates below 2Ω On all ranges: buzzer operates after 4 min if tester is switched on. 240mA nominal DESCRIPTION The IN2000 Series digital insulation and continuity testers are designed to carry out testing in accordance with International standards, including BS7671. There are two variants available, the 500V only IN2001 and the 250/500/1000V IN2003. The instruments are powered by six 1.5 volt manganese alkaline batteries type LR6. The instruments are supplied in a carrying case which contains the instruction book, test leads and clips. The carrying case has been designed to allow the tester to be operated in the case. The models have a push to operate and turn to latch test button on the insulation ranges as standard. On completion of an insulation test, a latched test button has to be manually released to discharge the installation under test. In the interest of safety the user should be aware of this. 5. SPECIFICATION IN2001/IN2003 Series 5.1 ELECTRICAL Voltage V~ Input Impedance: Continuity (Ω) Autorange: Test Voltage: Short Circuit Current: Battery Consumption: 0-500V AC ±2% of Full Scale 16MΩ nominal 0-20Ω in steps of 0.01Ω and 0-200Ω in steps of 0.1Ω Ω nominal 4V DC min 200mA min ±2% of reading ±1 digit 230mA nominal Buzzer Current Consumption: Operates below 2Ω On all ranges: buzzer operates after 4 min if tester is switched on. 240mA nominal

9 INSULATION 500V With the function switch in the MΩ 500V position, a test voltage of 500V DC is selected. The insulation resistance, 0-200MΩ, is 4. OPERATING INSTRUCTIONS IN2001/IN2003 Series INSULATION 1000V With the function switch in the MΩ 1000V position, a test voltage of 1000V DC is selected. The insulation resistance, 0-200MΩ, is CAPACITANCE DISCHARGE When testing insulation, the equipment under test should remain connected after releasing the test switch. This discharges any equipment capacitance via the tester, the warning lamp indicating the period of discharge. OVER RANGE In the event that the tester measures a value that exceeds the maximum reading possible on the particular range selected, the display will enter an over range condition. A single digit (1.), with no trailing zeros, will be displayed at the far left end of the display window, together with words OVER RANGE. - This should NOT be mistaken as a measured value of 1. Fig.1 Fig. 1 illustrates the front layout of a model IN2003 tester. The function switch selects OFF, Voltage (V~), Continuity with buzzer (Ω), and Insulation (MΩ) in three positions, with test voltages of 250V, 500V and 1000V DC respectively. On the IN2001 model there is only one MΩ position with a test voltage of 500V DC. The Voltage (V~) and Continuity (Ω) ranges are activated when selected by the function switch. The test switch can be operated as a momentary or latching action. To latch it, the switch should be pressed and rotated clockwise. To release it, the switch should be rotated anti-clockwise INSULATION 500V With the function switch in the MΩ 500V position, a test voltage of 500V DC is selected. The insulation resistance, 0-200MΩ, is 4. OPERATING INSTRUCTIONS IN2001/IN2003 Series INSULATION 1000V With the function switch in the MΩ 1000V position, a test voltage of 1000V DC is selected. The insulation resistance, 0-200MΩ, is CAPACITANCE DISCHARGE When testing insulation, the equipment under test should remain connected after releasing the test switch. This discharges any equipment capacitance via the tester, the warning lamp indicating the period of discharge. OVER RANGE In the event that the tester measures a value that exceeds the maximum reading possible on the particular range selected, the display will enter an over range condition. A single digit (1.), with no trailing zeros, will be displayed at the far left end of the display window, together with words OVER RANGE. - This should NOT be mistaken as a measured value of 1. Fig.1 Fig. 1 illustrates the front layout of a model IN2003 tester. The function switch selects OFF, Voltage (V~), Continuity with buzzer (Ω), and Insulation (MΩ) in three positions, with test voltages of 250V, 500V and 1000V DC respectively. On the IN2001 model there is only one MΩ position with a test voltage of 500V DC. The Voltage (V~) and Continuity (Ω) ranges are activated when selected by the function switch. The test switch can be operated as a momentary or latching action. To latch it, the switch should be pressed and rotated clockwise. To release it, the switch should be rotated anti-clockwise

10 The test switch is operated only when performing insulation tests, activating the insulation circuitry when pressed and discharging the line when released. Always switch off the tester after use. If the tester is inadvertently left on or is in continuous use, the buzzer will sound after approximately 4 minutes indicating the tester is on. The buzzer can be reset by switching off and then on again. NULL OPERATION The tester incorporates a circuit that compensates for the lead resistance on the continuity range. With the test leads shorted and continuity (Ω) selected, press the test switch until the display reads zero. The test lead resistance is now nulled out on the continuity range. BATTERY CHECK With the test leads shorted and the function switch in the MΩ 1000V position (MΩ 500V position on the IN2001 model), press the test switch and if the BAT symbol appears on the LCD, replace the batteries. Note that the condition of the batteries is constantly monitored and the BAT symbol could appear during operation. BATTERY REPLACEMENT Disconnect test leads and slacken the captive screws on the battery cover. Lift off the battery cover, remove the spent batteries and replace with new ones. Six X 1.5 volt manganese-alkaline type LR6. FUSE The fuse is located in the battery compartment and is used to protect the tester if the leads are connected to a live circuit when the continuity/resistance ranges are selected. NOTE: The condition of the fuse can be checked by selecting the continuity range, with the test leads disconnected, and if the fuse is either blown or not fitted properly the buzzer will sound and the LCD will read over range. To replace the fuse disconnect the test leads, remove the battery cover and the blown fuse then replace with a fuse of the correct type and rating. Fuse type 500mA HBC, see Spares and Accessories. VOLTAGE 0-500V AC Select V~ position on the function switch. Connect test leads to the circuit under test and the voltage will be displayed on the LCD. If the tester is connected to a live circuit the warning lamp will illuminate no matter what the position of the function switch, but doing so on the continuity range will result in the fuse blowing. Always check if the circuit under test is live with V~ selected before carrying out continuity or insulation tests. CONTINUITY WITH BUZZER 0-200Ω With the function switch in the ohms (Ω) position, the continuity resistance is displayed on the LCD. If the continuity resistance is less than 2Ω the buzzer will sound. INSULATION 250V With the function switch in the MΩ 250V position, a test. voltage of 250V DC is selected. The insulation resistance, 0-200MΩ is The test switch is operated only when performing insulation tests, activating the insulation circuitry when pressed and discharging the line when released. Always switch off the tester after use. If the tester is inadvertently left on or is in continuous use, the buzzer will sound after approximately 4 minutes indicating the tester is on. The buzzer can be reset by switching off and then on again. NULL OPERATION The tester incorporates a circuit that compensates for the lead resistance on the continuity range. With the test leads shorted and continuity (Ω) selected, press the test switch until the display reads zero. The test lead resistance is now nulled out on the continuity range. BATTERY CHECK With the test leads shorted and the function switch in the MΩ 1000V position (MΩ 500V position on the IN2001 model), press the test switch and if the BAT symbol appears on the LCD, replace the batteries. Note that the condition of the batteries is constantly monitored and the BAT symbol could appear during operation. BATTERY REPLACEMENT Disconnect test leads and slacken the captive screws on the battery cover. Lift off the battery cover, remove the spent batteries and replace with new ones. Six X 1.5 volt manganese-alkaline type LR6. FUSE The fuse is located in the battery compartment and is used to protect the tester if the leads are connected to a live circuit when the continuity/resistance ranges are selected. NOTE: The condition of the fuse can be checked by selecting the continuity range, with the test leads disconnected, and if the fuse is either blown or not fitted properly the buzzer will sound and the LCD will read over range. To replace the fuse disconnect the test leads, remove the battery cover and the blown fuse then replace with a fuse of the correct type and rating. Fuse type 500mA HBC, see Spares and Accessories. VOLTAGE 0-500V AC Select V~ position on the function switch. Connect test leads to the circuit under test and the voltage will be displayed on the LCD. If the tester is connected to a live circuit the warning lamp will illuminate no matter what the position of the function switch, but doing so on the continuity range will result in the fuse blowing. Always check if the circuit under test is live with V~ selected before carrying out continuity or insulation tests. CONTINUITY WITH BUZZER 0-200Ω With the function switch in the ohms (Ω) position, the continuity resistance is displayed on the LCD. If the continuity resistance is less than 2Ω the buzzer will sound. INSULATION 250V With the function switch in the MΩ 250V position, a test. voltage of 250V DC is selected. The insulation resistance, 0-200MΩ is

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd. Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

Digital Low Resistance Ohm Meter

Digital Low Resistance Ohm Meter BST-MGR01 Digital Low Resistance Ohm Meter INSTRUCTION MANUAL Index 1. Safety Rules... 2. Safety Check... 3. General Description... 4. Operating Instructions... 5. Display... 6. Specifications... 11-12

More information

I I e k ill L ill. INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER BESANTEK BST-ELC01 INSTRUCTION MANUAL

I I e k ill L ill. INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER BESANTEK BST-ELC01 INSTRUCTION MANUAL = = = = - - - BESANTEK - - BST-ELC1 INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER EARTH DIGITAL INDUST RIAL ELCB HAS OT ATl ONTE O C, 1:. : ==== === ;... P E R STE R ==!

More information

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale: Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse

More information

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale: Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse

More information

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Chek-A-Cell TM. Instruction Manual Rev A 8/12 Chek-A-Cell TM Instruction Manual 84-867 Rev A 8/12 INTRODUCTION: The CHEK-A-CELL is a digital battery load tester for all types of batteries in the 5.75 Volt to 20 Volt, 1 to 20 Amp Hour range. Rechargeable

More information

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT CM69 TRMS AC EARTH LEAKAGE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings

More information

KEWTECH. KT56 digital multi function tester. Instruction manual

KEWTECH. KT56 digital multi function tester. Instruction manual KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating

More information

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings

More information

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING VT25 / VT28 VOLTAGE TESTER Instruction Manual ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and full understanding of its benefi ts please read this

More information

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions 4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve

More information

Instruction Manual. Model 310 Digital Milli-Ohm Meter

Instruction Manual. Model 310 Digital Milli-Ohm Meter Instruction Manual Model 310 Digital Milli-Ohm Meter DESCRIPTION PAGE SAFETY RULES... 01 GENERAL DESCRIPTION... 02-03 FRONT PANEL LAYOUT... 04 PREPARATION FOR USE... 05 PRELIMINARY CHECKS... 05 PRECAUTIONS...

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER

More information

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN Contents 1. Safety Precautions... 1 2. Features... 3 3. Specifications... 4 4. Instrument

More information

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model 308A Digital Insulation & Continuity Meter INDEX PAGE INSTRUMENT LAYOUT... 1 INTRODUCTION... 2 SAFETY

More information

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING DIGITAL THERMOMETERS INSTRUCTION MANUAL ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and a full understanding of its benefits please read this manual

More information

BATTERY OPERATED DIGITAL MILLI-OHMMETER

BATTERY OPERATED DIGITAL MILLI-OHMMETER BATTERY OPERATED DIGITAL MILLI-OHMMETER C 1 P 1 P 2 C 2 MAX. DC20V MICROPROCESSOR CONTROLLED AC DC HOLD M A X M I N AUTO-HOLD Hz mv km ka ms DIGITAL MILLIOHM METER 2000 200.0 20.00 2000m Test Current Range

More information

1.Safe testing IMPORTANT:

1.Safe testing IMPORTANT: Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.

More information

3 PHASE TESTER & MOTOR ROTATION TESTER

3 PHASE TESTER & MOTOR ROTATION TESTER 3 PHASE TESTER & MOTOR ROTATION TESTER R S T TEST CAT. III 500V 3 PHASE TESTER & MOTOR ROTATION TESTER CCW CW BAT. L2 L1 L3 L1 L2 L3 MOTOR ROTATION INSTRUCTION MANUAL INDEX Page 1. INTRODUCTION... 1 2.

More information

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. 1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. KYORITSU will not accept liability for any damage or injury caused by misuse

More information

The insulation tester must only be used by a skilled and competent measuring equipment connected directly to utilization points

The insulation tester must only be used by a skilled and competent measuring equipment connected directly to utilization points IN2101 / IN2102 INSULATION TESTER INSTRUCTION MANUAL ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and a full understanding of its benefits please

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 8/05 Form #270 OPERATING INSTRUCTION MODEL 3005 DIGITAL INSULATION-CONTINUITY TESTER

More information

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Instruction Manual. Model 307A Analog Insulation & Continuity Meter Instruction Manual Model 307A Analog Insulation & Continuity Meter Index Page Safety Precautions... 1 Safety Notes... 2 Features... 2-3 Connections... 3 Specifications...... 4 Why Test is necessary...

More information

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-IT26 ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER INSTRUCTION MANUAL Index

More information

Table of Contents Title Page No.

Table of Contents Title Page No. Table of Contents Title Page No. INTRODUCTION 1 SAFETY PRECAUTIONS / WARNINGS 2 CONTROLS AND INDICATORS 4 PREPARATION AND CAUTION BEFORE USE 5 TESTING PROCEDURES 6 A. AC/DC VOLTAGE MEASUREMENT 6 B. RESISTANCE

More information

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC. INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material

More information

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale: Other products from Martindale: 18th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s Kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital

More information

HIGH VOLTAGE PROXIMITY DETECTOR

HIGH VOLTAGE PROXIMITY DETECTOR HIGH VOLTAGE PROXIMITY DETECTOR An ISO 9001:2008 Company Model 275 HP (Upto 275KV) / 500 HP (Upto 500KV) The 275HP / 500HP is a HIGH VOLTAGE proximity detector. 275HP has eight voltage detection settings

More information

MANUAL PCE-IT111

MANUAL PCE-IT111 www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 http://www.industrial-needs.com/

More information

TRIPLETT. Model 310 Type C Type 9

TRIPLETT. Model 310 Type C Type 9 TRIPLETT Model 310 Type 9 310-C Type 9 TABLE OF CONTENTS SAFETY RULES... 2 INTRODUCTION...8 SPECIFICATIONS... 9 GENERAL INSTRUCTIONS... 11 Test Leads... 11 Range Selection... 11 Scale Selection... 12

More information

HIGH VOLTAGE PROVING UNIT

HIGH VOLTAGE PROVING UNIT HIGH VOLTAGE PROVING UNIT INSTRUCTION MANUAL Index 1. Safety Precautions... 2. Specifications... 3. Features... 4. Connections... 5. Layout of Tester... 6. Instructions Label... 7. Proofing Methods...

More information

Microscope light manual

Microscope light manual Microscope light manual LS-12 and LS-14 LS-12 LS-14 1/9 Content Overview... 3 Mounting... 4 Light adjustment... 5 Mirror... 6 Filters... 6 Replacing microscope light... 7 Technical data... 8 Troubleshooting...

More information

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT. INSULATION TESTER EARTH MAX. AC 600V LINE AC -+ HOLD V k M LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 CAT.III 600V INSTRUCTION

More information

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects

More information

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF An ISO 9001:2008 Company 1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING FEATURES : Auto Discharge Function on all tests & all ranges. Gas

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7

More information

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international

More information

This manual covers the following model:

This manual covers the following model: www.skcltd.com chek-mate Air Flowmeter Operating Instructions This manual covers the following model: 375-07550 Purchase Details and Service Record Thank you for choosing an SKC product. Your purchase

More information

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings 1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

Metrohm 7A501 EXTRA SAFE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Metrohm 7A501 EXTRA SAFE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL CONTENTS 1. Safe testing... 2 2. Product summary and explanation... 5 2.1 Product summary... 5 2.2 Test Function... 5 2.3 Features...

More information

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA  KEWTECH Distributor Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA www.kewtechcorp.com KEWTECH 92-1618 04-03 KEWTECH KT61 digital multi function tester Instruction manual Contents 1 Safe

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card. 80T-IR Infrared Temperature Probe Instruction Sheet Introduction The Fluke 80T-IR Infrared Temperature Probe (the probe) is a noncontact temperature measurement accessory for use with a test instrument

More information

BM kv Digital Insulation Tester USER MANUAL

BM kv Digital Insulation Tester USER MANUAL M BM5200 5 kv Digital Insulation Tester USER MANUAL CONTENTS Safety warnings...3 Symbols used on instrument...4 Cleaning...4 General description...5 Insulation resistance test modes...5 Automatic discharge...5

More information

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com KTD30 Digital Insulation and Continuity Tester User Manual 1 kewtechcorp.com The Kewtech KTD30 Continuity Insulation Tester is designed for use by suitably qualified personnel familiar with electrical

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1 Introduction Descriptions All the information you need in one device. Verify

More information

KTD30 Digital Insulation and Continuity Tester

KTD30 Digital Insulation and Continuity Tester KTD30 Digital Insulation and Continuity Tester User Manual www.kewtechcorp.com 1 The Kewtech KTD30 Loop Impedence Tester is designed for use by suitably qualified personnel familiar with electrical supply

More information

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A Owner's Manual Please read this manual before using your inverter 1INTRODUCTION Thank you for choosing to purchase our inverters. Our power inverter series

More information

Go to to register your product and find more information.

Go to   to register your product and find more information. ESA609 Electrical Safety Analyzer Safety Sheet Go to www.flukebiomedical.com to register your product and find more information. Safety Information A Warning identifies hazardous conditions and actions

More information

INSTRUCTION MANUAL DM5B Fax: (503)

INSTRUCTION MANUAL DM5B Fax: (503) INSTRUCTION MANUAL DM5B 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The DM5B digital multimeter is a pocket sized, hand held, battery operated, voltage, current

More information

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User Guide. Model Insulation Tester / Megohmmeter. Introduction User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity

More information

KMP Insulation-Continuity Tester. Users Manual

KMP Insulation-Continuity Tester. Users Manual KMP 7036 Insulation-Continuity Tester Users Manual KMP7036 Insulation-Continuity Tester Users Manual English September 2011, Rev.1 2011 Amprobe Test Tools. All rights reserved. Printed in China Limited

More information

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to LH41A Clamp On Ammeter User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LH41A Clamp On Ammeter Users Manual English April 2007, Rev.2 2007 Amprobe Test Tools.

More information

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER KEW6201A CONTENTS 1. Safe testing 1 2. Procedure of removing cover. 3 2.1 Method of removing the cover. 3 2.2 Method of storing the cover. 3 3. Product summary

More information

Cable Length Meter INSTRUCTION MANUAL

Cable Length Meter INSTRUCTION MANUAL CLM100 Cable Length Meter INSTRUCTION MANUAL ENGLISH 1-800-547-5740 www.ueitest.com email: info@ueitest.com TABLE OF CONTENT Introduction Features icludes Safety Tips International Symbol Instructions

More information

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs Model AS-RC3260 TV Cart Rolling Cart for Audio Mount System & Flat Panel TVs GETTING STARTED Introduction Congratulations on the purchase of your new Helios AS-RC3260 Rolling Cart. For maximum benefit,

More information

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please

More information

Users Manual. MegOhmMeter

Users Manual. MegOhmMeter 1520 MegOhmMeter Users Manual September 2000 Rev.2, 2/03 2000-2003 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Model T2642 Wall Mount. Television Wall Mount with Tilt Option Model T2642 Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642 Television Wall Mount. For maximum benefit,

More information

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument. ASTROAI USER MANUAL DIGITAL MULTIMETER NOTE: Fully read and understand this manual before using this instrument. WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage

More information

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter DC-AC Power Inverter SAM-100-12 Owner's Manual Please read this manual before installing your inverter WARNINGS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY 1. Do not connect to AC distribution

More information

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL PAGE 2 WARNING Do not install, maintain or operate this equipment without first reading and understanding

More information

7/05 FORM#347 OPERATING INSTRUCTIONS MULTI FUNCTION TESTER MODEL 6030

7/05 FORM#347 OPERATING INSTRUCTIONS MULTI FUNCTION TESTER MODEL 6030 7/05 FORM#347 OPERATING INSTRUCTIONS MULTI FUNCTION TESTER MODEL 6030 Contents 1. Safety Precautions 1 2. Features 3 3. Specifications 4 4. Layout Diagram 7 5. Preparation for Measurement 9 6. Operation

More information

Part# Accessory Power Distribution Module

Part# Accessory Power Distribution Module 7 February 2006 Power Pod (1038800) Page 1 BD Powe r Pod Installation Instructions Part# 1038800 Accessory Power Distribution Module Power Pod Specifications: Eliminate multiple T-taps and splices on OEM

More information

Roller Door Operator

Roller Door Operator INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Roller Door Operator IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO COMMENCING THE INSTALLATION OF THE OPERATOR UNIT CAUTION This Automatic Opener

More information

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS MODEL: PST-15S-12A OWNER S MANUAL Please read this manual before operating your inverter. INDEX Contents General Safety & Installation... 3 Warning... 4 Description

More information

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Digital/Analog Megohmmeter Model 1026 USER MANUAL Digital/Analog Megohmmeter Model 1026 USER MANUAL Limited Warranty The Megohmmeter Model 1026, is warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture.

More information

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

TBX10A INSTALLATION/OWNER'S MANUAL 10 Sealed Enclosure with Built-in Amplifier TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier Getting Started Thank you for purchasing the Dual TBX10A 10" ported enclosure with built-in amplifier. Although Dual has

More information

Installation Instructions

Installation Instructions 1 BD DODGE CUMMINS PERFORMANCE E X H A U S T M A N I F O L D Installation Instructions Application List 1994-1998 12V 1045980 1998½-2002 24V 1045985 PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION KIT

More information

TRIPLETT. Series. Type 3. Railroad Test Sets Instruction Manual /07

TRIPLETT. Series. Type 3. Railroad Test Sets Instruction Manual /07 TRIPLETT 2000 Series Type 3 Railroad Test Sets Instruction Manual Model 2000 Model 2001 Model 2002 Model 2003 84-873 7/07 SAFETY RULES Warning This Tester has been designed with your safety in mind. However,

More information

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc 707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20

More information

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of

More information

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer PREPARATION Getting Started Thank you for purchasing the Dual BAK1500 compact amplified subwoofer. Although Dual has attempted to ensure

More information

INSTRUCTION MANUAL PET Fax: (503)

INSTRUCTION MANUAL PET Fax: (503) INSTRUCTION MANUAL PET1 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The PET1 is a convenient pocket-size multifunction tester, which combines the latest digital

More information

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Revision 012211 Table of Contents Basic Conveyor Features 3 Getting Started 4 Setting Up the Incline Conveyor 5 Belt Removal

More information

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced) Atlas ESR Capacitance and Equivalent Series Resistance Meter Model ESR60 (Enhanced) User Guide Peak Electronic Design Limited 2004/2008 In the interests of development, information in this guide is subject

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

110 Volt/12 Volt Portable Inflator

110 Volt/12 Volt Portable Inflator 110 Volt/12 Volt Portable Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.

The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece. Personal mouthpiece The Zenith+ features a built-in permanent mouthpiece for personal use. Push the hook to the side to extend the mouthpiece for personal testing. To use a separate mouthpiece with the

More information

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S VOLTMETERS PHASERS a n d A C C E S S O R I E S Operating and Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E WA U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. PHONE 847.473.4980

More information

DIGITAL RCD(ELCB) TESTER

DIGITAL RCD(ELCB) TESTER INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.

More information

Temperature Calibrator

Temperature Calibrator 724 Temperature Calibrator Product Overview PN 1547851 February 2000 Rev.2, 8/05 2000-2005 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective

More information

233 True-rms Remote Display Digital Multimeter Safety Information

233 True-rms Remote Display Digital Multimeter Safety Information 233 True-rms Remote Display Digital Multimeter Safety Information Go to www.fluke.com to register your product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice. M Megger Limited Archcliffe Road, Dover Kent CT17 9EN England T +44 (0)1 304 502101 F +44 (0)1 304 207342 E uksales@megger.com Megger Z.A. Du Buisson de la Couldre 23 rue Eugène Henaff 78190 TRAPPES France

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VTC180 DC/DC Converter An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T.

More information

20250 Module Installation Guide

20250 Module Installation Guide 20250 Module Installation Guide 2013.5-2017 RAM 6.7L Cummins Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable switch connector Power +12 volts (Red wire) & Ground (Black wire) Injector

More information

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Model FM2642 Wall Mount. Full Motion Television Wall Mount Model FM2642 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions FM2642 Television Wall Mount. For maximum benefit, please

More information

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com

More information

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual KT71 / Portable Appliance Tester POWERED BY Instruction Manual CONTENTS 1. Safe testing 1 2. Procedure of removing cover.. 3 2.1 Method of removing the cover... 3 2.2 Method of storing the cover... 3 3.

More information

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com

More information

Autoranging Industrial Multimeter

Autoranging Industrial Multimeter Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation

More information

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual

More information

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual IQS300 Series Quasi-Sine Inverter Installation & Operation Manual INTRODUCTION State of the Art MOSFET technology coupled with unique Soft-Start circuitry guarantees reliable operation. The ON-OFF switch

More information

MIT300 Series Insulation and Continuity Testers

MIT300 Series Insulation and Continuity Testers MIT300_UG_en_V11.qxp 14/1/09 3:03 pm Page 1 M MIT300 Series Insulation and Continuity Testers Megger MIT300-EN MIT 300 EN Insulation Resistance Continuity Tester Megger MIT310A-EN MIT 310A EN Insulation

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VTC140/240 SERIES Voltage Converters An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G

More information

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY BACK LIGHT D I G I TA L M U LT I M E T E R DT33B OPERATOR LIMITED WARRANTY AND LIMITATION OF LIABILITY This product will be free from defects in material and workmanship for one year from the date of purchase.

More information

MMV Digital Length Measuring Gauge INSTRUCTION MANUAL

MMV Digital Length Measuring Gauge INSTRUCTION MANUAL MMV Digital Length Measuring Gauge INSTRUCTION MANUAL Hymark Ltd. 427 Bark Cove Owensboro, KY 42303 (270) 683-3500 Fax (270) 683-2500 www.kentuckygauge.com 1 MMV_v2.2manual 2 Identification Data Model

More information

Users Manual. Phase Rotation Indicator

Users Manual. Phase Rotation Indicator 9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are

More information