Technical data. Standards: IEC/EN BG-GS-ET-15
|
|
- Tyrone Flowers
- 5 years ago
- Views:
Transcription
1 1 Technical data Contact variants Long life Multiple coding Thermoplastic enclosure Double insulated X 3 cable entries M20 Large wiring compartment High level of contact reliability with low voltages and currents Not sensitive to dirty conditions by virtue of patented roller system Slotted holes for adjustment, circular holes for location Standards: IEC/EN BG-GS-ET-1 Enclosure: glass fiber reinforced thermoplastic, self-extinguishing Actuator: stainless steel Protection class: IP67 to EN 6029 Contact material: silver Contact type: 1 NC contact Switching principle: A IEC slow action, NC contact with positive break Connection: screw terminals or connector M, 4-pole Cable section: max. 2. mm² min. 0.2 mm² (incl. conductor ferrules) Cable entry: 3 x M20 U imp : 6 kv U i : 00 V I the : A Utilization category: AC-1, DC-13 I e /U e : 4 A / 230 VAC 4 A / 24 VDC Max. fuse rating: 6 A gg D-fuse Positive break travel: mm Positive break force: N for each NC contact fitted Ambient temperature: 30 C +0 ºC Mechanical life: > 1 million operations Latching force: 30 N for ordering suffix R Actuating speed: max. 2 m/s Max. switching frequency: 4,000 operations/h Classification: Standards: EN ISO B d NC: 2,000,000 B d NO: 1,000,000 for max. % ohmic contact load Mission time: 20 years Bd dop x hop x 3600 s/h MTTF n d op 0,1 x n op t cycle 1 NC Connector 1 NC Approvals H 1-ZV➀K-➁-➂ Actuators must be ordered separately. see page 1-9 for actuators ➀ Ejection force R Latching force 30 N ➁ Cable entry M20 ST Connector M ➂ 4 Latching force N 1762 Front mounting 37 Gold-plated contacts 1-7
2 Technical data Contact variants Thermoplastic enclosure Long life Double insulated X 3 cable entries M20 Large wiring compartment High level of contact reliability with low voltages and currents Not sensitive to dirty conditions by virtue of patented roller system Available with LED Slotted holes for adjustment, circular holes for location EX version available AS-Interface Safety at Work available Approvals H -➀ZV➁K-➂-➃-➄ ➀ 1 NO / 1 NC 02 2 NC 03 3 NC 1 NO / 2 NC ➁ Ejection force R Latching force 30 N ➂ G24 With LED ➃ Cable entry M20 Cable entry ST Connector M bottom STL Connector M left STR Connector M right Standards: IEC/EN BG-GS-ET-1 Enclosure: glass fiber reinforced thermoplastic, self-extinguishing Actuator: stainless steel Protection class: IP67 to EN 6029 Contact material: silver Contact type: change-over contact with double break, type Zb or 2 NC or 3 NC contacts, with galvanically separated contact bridges Switching principle: A IEC slow action, NC contact with positive break Connection: screw terminals or connector M, 4-pole Cable section: max. 2. mm² min. 0.2 mm² (incl. conductor ferrules) Cable entry: 3 x M20 U imp : 6 kv U i : 00 V I the : A Utilization category: AC-1, DC-13 I e /U e : 4 A / 230 VAC 4 A / 24 VDC Max. fuse rating: 6 A gg D-fuse Positive break travel: mm Positive break force: N for each NC contact fitted Ambient temperature: 30 C +0 ºC Mechanical life: > 1 million operations Latching force: 30 N for ordering suffix R Actuating speed: max. 2 m/s Max. switching frequency: 4,000 operations/h Classification: Standards: EN ISO B d (NC): 2,000,000 B d (NO): 1,000,000 for max. % ohmic contact load Mission time: 20 years Bd dop x hop x 3600 s/h MTTF n d op 0,1 x n op t cycle -➀ZV➁K-➂-➃-➄ ➄ 4 Latching force N 1762 Front mounting 37 Gold-plated contacts 1-1 NO / 1 NC 2 NC 3 NC NO / 2 NC Connector 1 NO / 1 NC 2 NC Actuators must be ordered separately. L+ 24VDC L LED version: Ordering suffix G24, only available for version with one NO and one NC contact. Protected against incorrect polarity and voltage spikes. YE 1 GN
3 41 Rmin. Rmin. Rmin. Rmin. Rmin. 32 2,3 1/-B1 1/-B1-77 with centering guide 29,3 b b Flexible actuator 1/-B3 Rmin. 2, Rmin. ø4,2 ø Rmin. Rmin. R min ,3 14 1/-B with magnetic latch 1/-B1-4 with rubber mounting 1/-B with magnetic latch 2 Rmin. Rmin. 7 a Rmin. 4 Rmin. 3 Rmin. 2 a 7,3,3 1/-B with slot lip-seal Flexible actuator 1/-B2 Flexible actuator 1/-B6 2, Rmin. Rmin. 41 Rmin , 2 2 6,, /-B1-203 with ball latch 1/-B with magnetic latch 0 17 Actuator -STS30 96 with magnetic latch with slot lip-seal with ball latch 1/-B1 1/-B /-B /-B1-203 with centering guide with rubber mounting Flexible actuator with magnetic latch 1/-B1-77 1/-B1-4 1/-B2 1/-B Flexible actuator with magnetic latch Flexible actuator Actuator with or without emergency handle A detailed product description can be found on page 1-1/-B3 1/-B /-B6 -STS30 1-9
4 Mounting set MS 1/ Front mounting 1/ Lockout tag SZ /33 Connector plug Slot sealing plug 1/-1476 Tamperproof screws Ball catch 1/ Mounting set MS 1/ P MS 1/ R/P Lockout tag SZ /33 Slot sealing plug 1/-1476 Ball catch 1/ Front mounting with M nuts Connector plug M, 4-pole without cable 0990 with cable m 023 Connector plug M, -pole with cable m Tamperproof screws with unidirectional slots M x 333 M x 3339 M x (Quantity 2 pcs) 1-
5 -STS30- System variants -STS STS , 46, -STS30-03 Lockout tag SZ 41-1/-2 max max STS STS , Lockout tag SZ 41-1/ , , 2 2 6, STS STS STS30-02/-04/-0/-07 Centering device TF , STS30-01/-03/-06/-0 6, -3 96, STS30-0 The drawings are always shown with a view to the switch , 7, 20 4, 6 Mounting plate MP TG M 34 Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (for variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired safety switch and then the door handle system: for example -02ZVRK-ST and -STS with emergency handle without emergency handle with emergency handle without emergency handle -STS STS STS STS STS30-0 -STS STS STS30-0 Lockout tag for STS30-01/-03/-06/-0 SZ 41-1 for STS30-02/-04/-0/-07 SZ 41-2 Lockout tag with circular holes for STS30-01/-03/-06/-0 SZ for STS30-02/-04/-0/-07 SZ Centering device only for -STS30 and M 1-STS30 : TFA-020 TFI-020 (Product information see page 1-2) Mounting plate MP TG-01 1-
6 - I Technical data Contact variants With individual coding, up to 600 combinations Thermoplastic enclosure Long life Double insulated X 3 cable entries Large wiring compartment High level of contact reliability with low voltages and currents Not sensitive to dirty conditions by virtue of patented roller system Slotted holes for adjustment, circular holes for location Approvals H -➀ZI-➁-➂-➃ ➀ 03 3 NC 1 NO / 2 NC ➁ B1 Incl. actuator B1 B Incl. actuator B B Incl. actuator B B1-203 Incl. actuator B1-203 B1-77 Incl. actuator B1-77 ➂ 1762 Front mounting ➃ Cable entry M20 Cable entry M20 Standards: IEC/EN BG-GS-ET-1 Enclosure: glass fiber reinforced thermoplastic, self-extinguishing Actuator: stainless steel Protection class: IP67 to EN 6029 Contact material: silver Contact type: change-over contact with double break, type Zb or 2 NC or 3 NC contacts, with galvanically separated contact bridges Switching principle: A IEC slow action, NC contact with positive break Connection: screw terminals or connector M, 4-pole Cable section: max. 2. mm² min. 0.2 mm² (incl. conductor ferrules) Cable entry: 3 x M20 U imp : 6 kv U i : 00 V I the : A Utilization category: AC-1, DC-13 I e /U e : 4 A / 230 VAC 4 A / 24 VDC Max. fuse rating: 6 A gg D-fuse Positive break travel: mm Positive break force: N for each NC contact fitted Ambient temperature: 30 C +0 ºC Mechanical life: > 1 million operations Latching force: 30 N for ordering suffix R Actuating speed: max. 0.2 m/s Max. switching frequency: 4,000 operations/h Classification: Standards: EN ISO B d (NC): 2,000,000 B d (NO): 1,000,000 for max. % ohmic contact load Mission time: 20 years Bd dop x hop x 3600 s/h MTTF n d op 0,1 x n op t cycle The actuating direction of the actuator is identified by means of the marking on the enclosure. 3 NC NO / 2 NC The part number of the actuator is appended to the part number of the switch. The actuators are not individually available. 1-
7 R min. R min. R min. R min. 2,3 23 B1 Actuator B1-77 with centering guide Mounting set MS 1/ R min. R min. 2, Actuator B with magnetic latch Centering device TF. Ball catch 1/ R min. R min. 2 Actuator B with slot lip-seal Front mounting R min. R min. 2, Actuator B1-203 with ball latch Tamperproof screws B1 with magnetic latch B with slot lip-seal B with ball latch B1-203 with centering guide B1-77 Centering device (Product information see page 1-2) TFA-020 TFI-020 Mounting set MS 1/ P MS 1/ R/P Ball catch 1/ Front mounting with M nuts Tamperproof screws with unidirectional slots M x 333 M x 3339 M x (Quantity 2 pcs) 1-13
Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19
1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double
More informationSolenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5
.1 AZM 11 range Features Thermoplastic enclosure Manual and emergency release Long life Double insulated X High holding force, N N latching force Wiring compartment Actuation on de-energisation or energisation
More informationSolenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11
2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation
More informationSafety door-handle system STS
Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks
More informationAZM 161SK 12/12RKED/TU 024
10.06.2016 10:17:13h Datasheet AZM 161SK 12/12RKED/TU 024 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30
More informationDatasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350
Datasheet - AZ 3350-12ZUEK Safety switch with separate actuator / AZ 3350 Metal enclosure Latching handle Long life 40,5 mm x 114 mm x 38 mm High level of contact reliability with low voltages and currents
More informationSolenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5
2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly
More informationOrdering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161
10.06.2016 10:18:33h Datasheet AZM 161SK 12/12RKED/TU 110/230 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x
More informationSolenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5
2.22 415 range Features Metal enclosure Two switches in one enclosure Problem-free opening of stressed doors by means of bell-crank system Robust design Long life High holding force 3,500 N Adjustable
More informationOperating instructions Solenoid interlock AZM 161../.. 1. About this document. Content
Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides
More informationOperating instructions Solenoid interlock TKM/TKF. 1. About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationOperating instructions Solenoid interlock EX-AZM About this document. Content
EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information
More informationTechnical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC
AZM 00,,,,, M0x1, 0 1, AZM 00➀-T-➁➂ 0 1 Solenoid interlock (Solenoid interlock monitoring) Thermoplastic enclosure Sensor technology permits an offset of ± mm between actuator and interlock Intelligent
More informationOperating instructions Solenoid interlock AZM 161../.. 1. About this document. Content
Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides
More informationTechnical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :
55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V
More informationOrdering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂
BDF -NH BDF Technical data 3 39 6 4 8 8 M 5 5.5 69.5 Yellow enclosure cover Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminum profile systems Can be installed in the most favorable
More informationFloor and fine adjustment switches
Floor and fine adjustment switches 6 Introduction 6-2 AS 1 6-3 ASH 2 6-4 AFH 2 6-5 Reference table technical data 6-6 Universal switches 6-7 Floor and fine adjustment switches / Introduction ➀ ➁ ➂ Floor
More informationDatasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521
Datasheet - TV8S 521-02/20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521 Metal enclosure Good resistance to oil and petroleum spirit Mounting independent of hinge 92 mm x 81,5 mm x
More informationTechnical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.
8 Innovations 2/2 - Control panel BDF 2 BDF 2 5.5 22 29 39 3 4 6- Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminium profile systems Can be installed in the most favourable
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever
More informationSafety Switches with Separate Actuator SKC
Safety Switches with Separate Actuator SKC In terms of lengths, the SKC safety position switch is the 15 mm shorter variant of the SK. This makes it the right choice for confined installation conditions.
More informationPosition switches FR series
Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket
More informationPosition switches FR series
Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33
More informationSafety switches / Position switches / Command devices
Safety switches / Position switches / Command devices SAFE SWITCHGEAR FOR DEMANDING AND CRITICAL APPLICATIONS // Control technology / Catalogue 4 The Company PRODUCTS 8 Safety switches with separate actuator
More informationRecommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.
Metal-Enclosed Limit Switches ENM2 Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Product advantages Standard switch
More informationPosition switches FC series
A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever
More informationSafety switches for hinged doors
4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland
More informationPrewired position switches FF series
2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable
More informationSwitches with manual reset
Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever
More informationOperating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.
More informationOperating instructions Solenoid interlock AZM /.. 1. About this document. Content
Solenoid interlock AZM 415-../.. 7 Appendix 7.1 Comparison of the old and new contact configurations...6 8 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original 1. About
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow
More informationInstallation and Operating Instructions
Plastic encased safety interlocking switch Type PSEN me2/psen me3 Intended use The plastic encased safety switches PSEN me2 and PSEN me3 with separate actuator are suitable for the mounting on safety guards.
More informationPrewired position switches FF series
2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46
More informationInstallation and Operating Instructions
Plastic encased safety interlocking switch Type PSEN me4 Intended use The plastic encased safety switches PSEN me4 with separate actuator are suitable for the mounting on safety guards. They are designated
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC
More informationOnline data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES
Online data sheet i15-em03 Lock i15 Lock i15-em03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-em03 Lock 6034028 The actuator has to be ordered separately.
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationMicroswitches M series
Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection
More informationLR-LX-LK-LW Safety Switches with separate actuator
LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationTechnical data. Standards: IEC/EN thermoplastic tightening force on nut 22 mm A/F max. 300 Ncm Protection class: IP 67 to EN 60529
B /V Ø 20 0 5 60 Pg 00 22 3 Actuation from front Thermoplastic enclosure Central mounting Long life on-contacting principle Pre-wired cable available, cable length 1 m Protection class IP 6 When the switches
More informationOperating instructions Solenoid interlock AZM 170
Solenoid interlock AZM 170 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions FR NL JP Vous trouverez la version actuelle du mode d emploi dans
More informationMiniaturized limit switches
Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches
More informationEncontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.
Solenoid interlock AZM 170-../.. 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationCommand devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.
.1.1.1 One-side operation ZS 71 range 40 30 ø10 10 22 6 8 53,5 18 24 105 33 56 Pg 13,5 52 17,5 42 15 Features To EN 418 Metal enclosure 2 contacts Small body 2 cable entries Various spring force variants
More informationTechnical data. Standards: IEC/EN chromated and painted Protection class: IP 67 to EN 60529
B 20 16 21,5 M 16x1,5 60 5 1 52 Aluminium enlosure Long life on-contacting principle 1 Reed contact Particularly resistant to vibration Available for actuation from front or side Actuating distance up
More informationOperating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content
. bout this document Operating instructions.............pages to 8 Original. Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationS826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en
2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive
More informationSelection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic
Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationDatasheet - MV8H Y
18.03.2014-17:45:05h Datasheet - MV8H 330-11Y Position switch / light Position switch / M 330 / M 330 Roller lever 8H Preferred typ Metal enclosure Long life 40 mm x 76 mm x 40 mm ( basic component) Suitable
More informationSafety rope switch with reset for emergency stop
Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With
More informationSafety switches for hinged doors
4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationSERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE
SERIES Z/T23 Safety-Rated, Positive-Break Miniature DIN Limit Switches Features & Benefits Positive-Break NC contacts won t stick or weld shut. Watertight design meets IP washdown requirements. Rugged,
More informationDoor locking devices. 4 Schmersal Industrial Switchgear
with and without a checking device The door locking devices from the AV series serve the purpose of monitoring and interlocking of 1- and 2-leaf lift landing doors. The safety locking devices fulfil the
More informationMicroswitches MK series
D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page
More informationLimit switches 3. Page 92. Page 92
Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards
More informationOperating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content
Pull-wire emergency-stop switches 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationSeries S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.
Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover
More informationSafety rope switch without reset for simple stop
afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE
More informationMicroswitches MK series
Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with
More informationOperating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content
1. bout this document EN Operating instructions............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationPre wired limit switches
Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationSolenoid interlock AZM 200 The non-contact interlock.
Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery.
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More informationPendant control stations 6
Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment
More informationAutomation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches
Automation // SYSTEMATIC CONTROL SWITCHGEAR Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches 6 Emergency pull-wire switches // Selection table Emergency pull-wire switches from page
More informationD4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -
Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head
More informationNHP SAFETY REFERENCE GUIDE
NHP SAFETY REFERENCE GUIDE 3. PRODUCTS Safety Switches Safety Interlock Switches ST14 Series Light duty safety interlock switch, ideal for guard door monitoring applications. Thermoplastic enclosure Double
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationSEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel
3.14 Technical data safety-monitoring module SRB 201ZH......... 11 Operating instructions... pages 1 to 38 Translation of the original operating instructions 4 Classification 4.1 Safety classification...................................
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationMaintained selector switches, spring return selector switches with short or long knob
Maintained selector switches, spring return selector switches with short or long knob.1 version with 46 mm long knob: see below and product range table Maintained selector selector switch inhibit refer
More informationLimit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation
Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK
More informationEmergency pull-wire, Belt-alignment, Slack-wire switches. Automation. Catalogue // SYSTEMATIC CONTROL SWITCHGEAR
Automation Emergency pull-wire, Belt-alignment, Slack-wire switches // SYSTEMATIC CONTROL SWITCHGEAR Catalogue 4 The Company PRODUCTS 6 Emergency pull-wire switches 12 Selection table Emergency pull-wire
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationHinged Safety Door Switch
Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),
More informationLimit Switches - Limit Type (PS31L) Plastic Body IP65
Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A
Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air
More informationS840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en
Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break
More informationAutomation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches
Automation // SYSTEMATIC CONTROL SWITCHGEAR Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches 4 The Company PRODUCTS 8 Emergency pull-wire switches 12 Selection table Emergency pull-wire
More informationManual Reset Limit Switch
Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More informationD4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -
Compact Guard-locking Interlock Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable
More informationSelection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic
Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationF E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing
Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b
More informationRope safety switches with reset for emergency stop
Rope safety switches with reset for emergency stop Description and technical data hese rope operated safety switches are installed on machines or conveyor belts, to activate the emergency stop of the machine
More informationFOOT SWITCHES
- 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,
More informationSafety Switches with Separate Actuator, Plastic Housing
Safety Switces wit Separate Actuator, Plastic Housing Selection table for safety switces Mounting AS Mounting to DIN EN 5007 AB Mounting wit 0 mm spacing M SM Tread M0 x.5 for cable gland M -pin ; 6 pin
More information