Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data

Size: px
Start display at page:

Download "Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data"

Transcription

1 Door Drive Unit The is an electrical door drive unit which automatically opens hinged lift doors up to 200 kg. As the operating arm is not directly fixed to the door, all landing doors in the lift can be opened by a single unit mounted above the door in the car or on the ceiling. The arm of the DICTAMAT 304 AZ is not connected to the landing door. It just pushes the door open with a roller on the end of the lever.the door is closed by the already installed door closer or closing spring. The is equipped with an electronic position control system. The final positions are therefore memorized in the control system - even in the event of a power failure. The drive unit slows down before reaching the final positions. This feature increases the safety and avoids noise and unnecessary strain on the door. A response level for a reversing function can also be precisely adjusted by the control system, along with the speed. If the door hits an obstacle whilst opening, it reverses immediately. for hinged lift landing doors Technical Data Force of drive unit max. 100 Nm Door weight max. 200 kg Door width max. 1,2 m Door speed opening and closing speed separately adjustable; 2 to 8 s / 90 Power supply 230 V AC / 2 A / Hz Motor (2,5 m plug-in cable) 24 V DC / 90 W / IP 40 Operating options Impulse OPEN, CLOSE, OPEN/CLOSE DICTATOR TECHNIK GMBH Gutenbergstr. 9 D Neusäß Germany Tel. (0821) Fax (0821) info@dictator.de 0032 Page

2 Door Drive Unit Dimensions Contact switch (Lever inside cabin) ø x ø 7 Additional bearing for the axle Position control 570 All dimensions are in mm Control system SQUARE ESC Power ENT Alarm 335 All dimensions are in mm Page DICTATOR TECHNIK GMBH Gutenbergstr. 9 D Neusäß Germany Tel. (0821) Fax (0821) info@dictator.de 0032

3 Door Drive Unit Description The drive unit is either mounted on the cabin roof or in the car on the lintel directly above the cabin door. In both cases please observe any relevant safety regulations. The drive unit is ready to mount once delivered and includes a plug-in cable connecting the control system to the motor. The length of the axle is adjustable, so that it can be adapted exactly to the requirements of each cabin. The maximum distance between the bottom edge of the drive unit on the cabin ceiling and the operating arm opening the door is 350 mm. The drive unit can be used both for right and left-hand doors. The operating arm is not connected to the landing door of the lift but is provided with a plastic roller which runs on the door. In the event of a power failure the door can therefore always be moved freely by hand. The operating arm pushes the door open. When it has reached the opened position it returns to the closed position as soon as the set time for the automatic closing has expired. The closing speed for the operating arm should be higher than the opening speed. When the operating arm has reached its closed position, a contact switch connects with the central lift control system, making sure that the lift only starts moving again, when the operating arm is securely back inside the cabin. The door itself is closed by the door closer or closing spring combined with a door check already installed. DICTATOR TECHNIK GMBH Gutenbergstr. 9 D Neusäß Germany Tel. (0821) Fax (0821) info@dictator.de 0032 Page

4 Door Drive Unit Operating Options The control system designed for the use with the is the SQUARE 820 of the system of control units SQUARE. The control system permits both deadman as well as impulse operation. When using it on lift doors we recommend strongly the impulse operation. All final positions are adjusted in the control system. Apart from the positions OPEN and CLOSED the positions for changing to the crawling speed before the positions OPEN and CLOSED have to be adjusted. Starting at these positions the speed of the drive unit is reduced and the door enters slowly the final position. The SQUARE 820 offers the following functions: Deadman OPEN, CLOSE: Door opens/closes as long as the switch is pressed The deadman function can be adjusted separately for OPEN and CLOSE Impulse OPEN: Door opens completely after pressing the switch shortly Partial opening: Door opens partially (to an additional position adjusted in the control system) after pressing the switch shortly Impulse CLOSE: Door closes completely after pressing the switch shortly Alternating impulse OPEN / CLOSE: after each impulse the door moves in the opposite final position STOP As long as the door opens, it stops as soon as the STOP switch is pressed. When using the STOP switch during closing the arm of the drive unit is stopped. The door goes on closing until it hits the lever. Automatic closing: Door closes automatically after a time pre-set between 1 and 999 sec. Further adjustment possibilities: Safety equipment Function relay contact (e.g. for the connection of a sirene, warning flashlight etc.) Operation characteristics of the motor: Smooth starting (adjustment of the acceleration and deceleration when the motor starts or is disconnected) Fast Stop (when safety equipment is actuated ) Distance for the crawling speed before the final position OPEN and CLOSED, crawling speed OPEN, crawling speed CLOSE Response level for the reverse function Please make sure that the motor reverses when the load exceeds 150 N Components Included Drive unit (24 V DC motor, casing zinc-plated) with adjustable axle, contact switch on the axle 2,5 m connecting cable to the control system Order Information Part no Control system SQUARE 820 Part no Page DICTATOR TECHNIK GMBH Gutenbergstr. 9 D Neusäß Germany Tel. (0821) Fax (0821) info@dictator.de 0032

5 I. Mechanical Installation I/1 Upon delivery the drive unit is provided with a securing screw for the transport. The red marked screw may not be removed unless the arm of the drive unit has been installed (see I/10). ill. 1 I/2 a) Determine the position of the drive unit on the roof of the cabin: - Normally the drive unit is fixed on the roof at a 90 -angle to the door. Should there not be enough space available it can also be mounted parallel to the door. - When choosing the position please make sure that the arm can open the door up to the opening angle that is required and does not get obstructed by the door frame before reaching this position! ill. 2a b) Make a large enough opening in the roof of the cabin through which the axle of the drive unit can be put through into the cabin (diameter of the axle 25 mm) Please observe the relevant regulations. ill. 2b I/3 The bearing included in the delivery is pushed onto the axle and fixed from below to the ceiling of the cabin serving at the same time - to cover the opening in the ceiling of the cabin - to stabilize the axle ill. 3 I/4 Fix the drive unit in an exactly horizontal position on the roof of the cabin. Tel. (0821) Fax (0821) info@dictator.de 0032 Page

6 I. Mechanical Installation - continuation I/5 Carefully remove the lid from the casing of the drive unit, loosening the earth cable. I/6 Put the arm of the drive unit on the axle and fix it from below and from the side with the hexagon socket screws. ill. 4 I/7 Open the landing door halfway and fix it there with a wedge (or similar). I/8 Securing screw for transport ill. 5 Tensioning device From the cabin insert the axle into the drive unit. For this purpose the tensioning device has to be loosened. It is tightened with hexagon socket screws M6. These screws have to be loosened (make sure you always loosen the opposite screw as the next one). Insert the axle. If the axle does not enter completely, loosen the silverplated screws completely. In their place insert M8 screws. This way the tensioning device comes loose completely. Determine the height in which the arm of the drive unit has to operate. Move the arm until it reaches the half opened door and fix it in this position to the drive unit with the 9 hexagon socket screws. ATTENTION: Tighten the screws equally (16Nm) (always the opposite one as the next), in several rounds, making sure that the axle is fixed in a absolutely straight position. Finally control once more whether all screws are tightened properly. If the axle has to be removed some time, just follow the instructions for loosening the tensionning device. I/9 Open now the landing door completely and fix it there again with a wedge. The arm of the drive unit stays in its present position (halfway open). I/10 IMPORTANT Page Remove the red marked securing screw for the transport (see ill. 5) Tel. (0821) Fax (0821) info@dictator.de 0032

7 I. Mechanical Installation - continuation I/11 Install the control system on the cabin roof at an easily accessible position. I/12 ill. 6 Plug the 5-channel-plug of the connection cable drive unit - control system into the connector of the drive unit (there are two connectors provided, one for each possible opening direction of the door). The connectors are easily identified by the labels on the casing of the drive unit. Tel. (0821) Fax (0821) info@dictator.de 0032 Page

8 II. Electrical connection / Putting into service II/1 The control system to be used along with the drive unit DICTAMAT 304 AZ is the SQUARE 820 (part no ) ESC Power ENT Alarm 335 II/2 II/3 The leads of the connection cable delivered along the with the are labeled at the end that is connected to the control system. The connection to the control system is done according to the wiring diagram of the SQUARE 820. Before putting the whole installation into service an OPEN and CLOSE push button should be connected. Connect the control system to the 230 VAC mains. All adjustments and programming are carried out with the membrane keys and the LCD display on the lid of the control system. Please follow the instructions of the technical manual of the SQUARE 820. II/4 Adjustment of the final positions: Please follow the instructions of the technical manual of the SQUARE 820. However in case of the DICTAMAT 304AZ some adjustments difer from the standard ones as the arm is not fixed to the door. ATTENTION: if the door closes when you push the push button OPEN, please verify the following points: - the connector of the connection cable is plugged into the correct plug of the drive unit (door DIN right or left)? - Correct connection of the connecting cable in the control system? Page Tel. (0821) Fax (0821) info@dictator.de 0032

9 II. Electrical connection / Putting into service - cont. We recommend the following values for a first adjustment of the final positions: Final position "Door CLOSED" : please note that the value refers to the position of the arm. In the position "Door CLOSED" the arm has to be inside the cabin, in a parallel position to the cabin door. It is absolutely necessary to control this position again, once the contact on the axle (see II/1 of this manual) has been installed as otherwise this contact might be destroyed. Final position "Crawling speed CLOSE": This position should be positioned as far as possible before the final position "Door CLOSED", as the arm is not slowed down by any load when closing. Its intertia keeps it moving even when the motor has been switched off. To make sure it stops in the position "Door CLOSED", the closing speed has to be reduced as soon as possible. Final position "Crawling speed OPEN": This position also should be adjusted well before reaching the position "Door OPEN" as the arm is not fixed to the door and can not actively slow down the door. It just can push the door open at a slower speed. Final position "Door OPEN": the final position adjusted in the control system should be positioned about 30 before the real position "Door OPEN" as the door and the arm continues opening due to their inertia even when the motor has been switched off. After an initial adjustment the values should be modified and memorized in order to match exactly the requirements of each installation. II/4 Recommended values for the motor adjustments: - Nominal motor power (depends on the motor used in the installation) For the DICTAMAT 304AZ, part no : 90 W - Crawling speed: as low as possible (10 %) - Closing speed: as high as possible (90%) - Soft start: in opening direction: as high as possible (50%) in closing direction: as low as possible (10%) - Reverse function: in opening direction: as high as possible (14) (otherwise the arm might reverse when it hits the door during opening). All above mentionned values are just approximate values to facilite an initial adjustment. In a second step they have to be adjusted precisely to the requirements of each installation. Tel. (0821) Fax (0821) info@dictator.de 0032 Page

10 III. Installation of the contact switch III/1 ill. 7 After having put the DICTAMAT 304AZ into service the mechanical contact switch has to be installed. For this purpose the arm has to be in the closed position. The contact is fixed to the drive unit at the indicated position (choose the same opening direction as for the connection of the 5-channel plug of the connection cable). Slip the bracket with the contact bridge from above onto the axle of the drive unit, observing the opening direction of the door (see I/12). Before tightening the bracket on the axle make sure there remain a few millimetres of clearance between the contact bridge and the contact. Make sure that the contact bridge enters the contact properly (open and close the door with the motor several times). If necessary readjust the positions "Crawling speed CLOSE" and "Door CLOSED". III/2 Connect the earth cable again to the lid of the casing, put the lid back on the drive unit and fix it. Page Tel. (0821) Fax (0821) info@dictator.de 0032

11 IV. Service Diagnosis, Trouble shooting IV/1 Motor does not start a) Make sure that the red marked securing screw for transport has been removed (see I/10) Adjustment screw position control ill. 8 b) Make sure that the plug of the connection cable from the control system to the drive unit is sitting properly in the connector of the drive unit. c) Check whether the position control system of the drive unit has not been misadjusted: c1) Remove the plug of the connection cable from the control system c2) Turn the arm of the drive unit until it reaches the halfway open position c3) Turn the adjustment screw of the position control system with a small screw driver until the resistance between the binders 87 and 88 on the drive unit reaches 500 Ohm. c4) Plug the 5-channel-plug of the connection cable back into the connector of the drive unit and adjust the positions "Door OPEN" and "Door CLOSED". IV/2 Arm of the drive unit moves into the wrong direction IV/3 Arm reverses immediately after reaching a final position Change the sense of rotation: plug the 5-channel-plug of the connection cable from the control system into the other connector on the casing of the drive unit. The response level of the reverse function has been adjusted at too low a value (see technical manual of the SQUARE 820). IV/4 When reaching the position "Door OPEN" the door goes on opening until hitting a mechanical stop, the motor is not switched off and does not accept a CLOSE command Readjust the position "Door OPEN" of the position control system (see technical manual of the SQUARE 820). Tel. (0821) Fax (0821) info@dictator.de 0032 Page

12 V. Wiring diagram SQUARE 820 / X reserved Limit switch Door OPEN Limit switch Crawling speed OPEN X s + The screening of this cable is only to be connected in the control system. On the side of the drive unit it has to be insulated. 32/33 reserved Control System SQUARE Limit switch Crawling speed CLOSE Limit switch Door CLOSED OPEN switch for partial opening Switch CLOSE Switch STOP Switch OPEN Relay contact K1 16A/250V M+ M- L N PE NC C NO VDC 24 VDC for external consumers* Netztrafo Safety device* max. length of the connection cables 30 m 230 VAC Drive Unit + - Motor Position Door CLOSED Position Door OPEN - s + * Max. power supply for additional consumers: 895 ma (valid for the drive units DICTAMAT 304, DICTAMAT and DICTAMAT ) Page Tel. (0821) Fax (0821) info@dictator.de 0032

DICTATOR Door Checks

DICTATOR Door Checks DICTATOR Door Checks Ensure Doors to Close Quietly. Doors can be incredibly noisy. Not only when people slam them, but also due to air pressure, gusts of wind and inadequate door closers. The more violent

More information

Oil Dampers with Fixings on Both Ends

Oil Dampers with Fixings on Both Ends amping Engineering Oil ampers with Fixings on Both Ends Oil ampers with Fixings on Both Ends Oil dampers with fixings on both ends are used when moving objects may not exceed a certain speed e.g. flaps,

More information

DICTATOR Door Checks

DICTATOR Door Checks DICTATOR Door Checks Ensure Doors to Close Quietly. Doors can be incredibly noisy. Not only when people slam them, but also due to air pressure, gusts of wind and inadequate door closers. The more violent

More information

Closing Devices DICTAMAT 50 Series

Closing Devices DICTAMAT 50 Series Closing Devices DICTAMAT 50 Series DICTATOR offers also for small sliding doors a reliable, mechanical closing device, the DICTAMAT 50. One of its advantages is that both closing speed and force are exactly

More information

Closing Devices DICTAMAT 50 Series

Closing Devices DICTAMAT 50 Series Closing Devices Series DICTATOR offers also for small sliding doors a reliable, mechanical closing device, the. One of its advantages is that both closing speed and force are exactly adjustable. The door

More information

DICTATOR Solutions for Sliding Doors

DICTATOR Solutions for Sliding Doors DICTATOR Solutions for Sliding Doors Even moving small sliding doors may implicate quite a lot of requirements: - The sliding door should close automatically, but an expensive door operator is not required

More information

Lift Equipment. Table of Contents Lift Equipment. DICTATOR DHM 500 Homelift Page (according to the Machinery Directive)

Lift Equipment. Table of Contents Lift Equipment. DICTATOR DHM 500 Homelift Page (according to the Machinery Directive) Table of Contents Lift Equipment Lift Equipment DICTATOR DHM 500 Homelift Page 01.003.00 (according to the Machinery Directive) 200 mm DICTATOR DHE Lift Page 01.009.00 (according to Lift Standard EN 81-2)

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

DICTATOR Damping Solutions

DICTATOR Damping Solutions DICTATOR Damping Solutions Types of Dampers and Functioning DICTATOR damping solutions offer four different lines of dampers: 1) EDH and ZDH final dampers Final dampers are used to slow down a movement

More information

Damping Engineering Radial Dampers RD 240/241. Radial Damper RD 240/241 with Gear Wheel. Installation and Operating Instructions.

Damping Engineering Radial Dampers RD 240/241. Radial Damper RD 240/241 with Gear Wheel. Installation and Operating Instructions. Radial Damper RD 240/241 with Gear Wheel For continuous damping with a revolving chain DICTATOR radial dampers provide continuous damping over unlimited distances. Although designed for sliding doors,

More information

SERIES A & AA ROLLER DOORS INSTALLATION GUIDE

SERIES A & AA ROLLER DOORS INSTALLATION GUIDE SERIES A & AA ROLLER DOORS INSTALLATION GUIDE THESE INSTRUCTIONS ARE PROVIDED FOR USE BY EXPERIENCED INSTALLERS OF GARAGE DOORS BY UNDER-TAKING THE INSTALLATION OF THIS DOOR, THE INSTALLER UNDERSTANDS

More information

AUTOMATIC CONTROL ROLLING DOOR OPENER

AUTOMATIC CONTROL ROLLING DOOR OPENER AUTOMATIC CONTROL ROLLING DOOR OPENER INSTALLATION INSTRUCTION AUTOMATIC OBSTRUCT PHOTOELECTRIC BEAM ROLLING CODE SYSTEM AUTO CLOSE DOOR ANTI-THEFT SYSTEM INSTALLATION INSTRUCTION AND RDO OWNERS MANUAL

More information

user's manual nx frequency converters brake resistors

user's manual nx frequency converters brake resistors user's manual nx frequency converters brake resistors INDEX Document code: ud00971e Date edited: 1.10.010 1. GENERAL... 3 1.1 Requirement for braking... 3 1. Brake components... 3 1.3 Classes of use...

More information

DICTATOR Final Dampers

DICTATOR Final Dampers DICTATOR DICTATOR final dampers are needed to slow down all kinds of rotative or linear movement. Their relatively long strokes offer sufficient saftey distances. The final dampers are available in both

More information

Electro-Mechanical Swing Operator. Table of Contents

Electro-Mechanical Swing Operator. Table of Contents *640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product

More information

Electrical Actuator HH-500 REsearch COntrol

Electrical Actuator HH-500 REsearch COntrol Badger Meter Europa GmbH Electrical Actuator HH-500 REsearch COntrol Instruction Manual January 2008 WARNING This electrical actuator can be used in high voltage areas. Hazardous voltages are present in

More information

vacon nx ac drives brake resistors user manual

vacon nx ac drives brake resistors user manual vacon nx ac drives brake resistors user manual GENERAL vacon 1 TABLE OF CONTENTS Document code: DPD01573C Date edited: 7.1.016 1. GENERAL... 1.1 The requirements for braking... 1. Brake components...

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

Operating manual and installation instructions ENGLISH. Electronic engine remote control. Copyright 2001 Vetus den Ouden n.v.

Operating manual and installation instructions ENGLISH. Electronic engine remote control. Copyright 2001 Vetus den Ouden n.v. Operating manual and installation instructions ENGLISH Electronic engine remote control Copyright 00 Vetus den Ouden n.v. Schiedam Holland Contents Introduction... General conditions of use... Operating....

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

HIGH SPEED SLIDING GATE OPENER

HIGH SPEED SLIDING GATE OPENER HIGH SPEED SLIDING GATE OPENER Model: is1200 + Elsema s Eclipse Control Card with GDS Operator USER MANUAL CONTENTS Section No: Page No: 1 Safety Precautions 3 2 Wiring Requirements 4 3 Installation details

More information

TECHNICAL MANUAL GTB16N

TECHNICAL MANUAL GTB16N TECHNICAL MANUAL GTB16N 1/20 1. INTRODUCTION 1.1 Purpose 1.2 Before Service 1.3 Safety 1.3.1 Hazard Definitions 1.3.2 For Your Safety 1.4 Specifications & dimensions 1.5 Description 2. HYDRAULIC SYSTEM

More information

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş. 1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.

More information

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş. 1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.

More information

VBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers)

VBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers) Thickness and Width Gauge for Strip and Profile (with lateral guide rollers) VBK 2596/12E/RSF Operating- & Service Instructions erstellt am 5.2.1998 freigegeben am Bemerkungen Rev.01 Seiten:16 Name: Rietdorf

More information

Push Type Gas Springs

Push Type Gas Springs Push Type Gas Springs ICTATOR high-performance push type gas springs make life easier by lifting loads smoothly and effortlessly. We have a vast product range with many potential applications. We manufacture

More information

Features IN THIS CHAPTER

Features IN THIS CHAPTER CHAPTER THREE 3Special Features IN THIS CHAPTER Motor Braking Regeneration Solutions Sharing the Power Bus: V Bus+ and V Bus- Current Foldback (I T Limit) Front Panel Test Points Resolver Alignment ➂ Special

More information

Target Retrieval Systems

Target Retrieval Systems Target Retrieval Systems Basic Motor Manual Rev 10 Note: Check our website for the latest version of this manual Super Target Systems www.supertargetsystems.com TRSX-36024V Basic Motor Super Target Systems

More information

Trouble Shooting Guide for V100 Positioner

Trouble Shooting Guide for V100 Positioner Trouble Shooting Guide for V100 Positioner 1) 1.V100 not responding to input signal a) The tubing to the actuator may be incorrect i) Plant Air Supply should be ported to the Sport on the side of the positioner.

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

Operating Manual Model- P282 Digiflow Controller

Operating Manual Model- P282 Digiflow Controller Operating Manual Model- P282 Digiflow Controller Totalizer mode Controller 00.00 LPH 0000000.0 L t s SET SCL ENT Model- P282 Tecnical specification of flow sensor P812 Flow Rate Range : 0.5 to 5 m/s (1.6

More information

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 000/S-X MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S000X- VER045- For information on this product and other

More information

OPERATOR TROUBLESHOOTING GUIDE

OPERATOR TROUBLESHOOTING GUIDE OPERATOR TROUBLESHOOTING GUIDE ABOUT THE TROUBLESHOOTING GUIDE This document is provided for the use of qualified operator installers. The installer should familiarize themselves with this guide Options

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER R MAGIC BUTTON FS0 & LPK5 FAST SLIDER OPERATORS MANUAL FEATURES High speed -800mm/second Corrosion resistant - Hot dip galvanised base with stainless steel cover Speed flexibility - Slow start / slow stop

More information

STAKA. Manual for electric operation. Dakluiken Flachdachausstiege Roof access hatches Trappes de toit

STAKA. Manual for electric operation. Dakluiken Flachdachausstiege Roof access hatches Trappes de toit STAKA Manual for electric operation General This manual provides instructions in how to correctly hook up and operate the Staka electrical operating system. The electrical operating system may only be

More information

NSGV EVE-ER I, O, & M MANUAL

NSGV EVE-ER I, O, & M MANUAL TABLE OF CONTENTS Rail Layout.. Page 1 Support Placement...Page 1 Rail Assembly.Page 1 Rail Duct Connections.. Page 2 Rubber Lip Installation.. Page 3 Pneumatic End Stop. Page 4 End Stop. Page 4 End Cap..

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

Starter Removal and Installation Instructions

Starter Removal and Installation Instructions er Removal and Installation Instructions CAUTION: Always use care when working on your vehicle! Do NOT disconnect any electrical cables or wiring while the engine is running! WARNING: Before starting work,

More information

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS TABLE OF CONTENTS 1.0 - WARNINGS 2.0 - GENERAL DATA 2.1 - Technical characteristics 2.2 - Data on electrical

More information

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual Electro-Pneumatic Positioner Series 830/831-WP/EX Operation & Maintenance Manual Electro-Pneumatic Positioner Model 830/831- WP/EXP This operation & maintenance manual corresponds to Forbes Marshall Arca

More information

MOTOR MANUAL. Rev 9.2 TRSX-36024V. Note: Check our website for the latest version of this manual. Super Target Systems.

MOTOR MANUAL. Rev 9.2 TRSX-36024V. Note: Check our website for the latest version of this manual. Super Target Systems. MOTOR MANUAL Rev 9.2 TRSX-36024V Note: Check our website for the latest version of this manual Super Target Systems www.supertargetsystems.com Motor Manual Rev 9.2 Super Target Systems www.supertargetsystems.com

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009 OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

AF Series Spring Return Direct Coupled Actuator

AF Series Spring Return Direct Coupled Actuator AF Series Spring Return Direct Coupled Actuator Minimum in-lb torque For damper areas up to sq-ft* (For lower torque, see NF or LF series) Applications Direct Coupling - The Belimo Concept Remove for /

More information

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend: General technical data: 1.) Anodised aluminium housing with a connecting rod made of aluminium (in the case of motor types G..B, G..C, G..D and G..E, the connecting rod is Ø18, for all other motor types

More information

ED SERIES SAFETY LIMIT SWITCH

ED SERIES SAFETY LIMIT SWITCH Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make

More information

632 Western Avenue Henniker, New Hampshire Tel. (603) Fax (603) POSITION OF THE ROLLER PLATES

632 Western Avenue Henniker, New Hampshire Tel. (603) Fax (603) POSITION OF THE ROLLER PLATES POSITION OF THE ROLLER PLATES The roller plate must be positioned as shown. The measurement to both of the roller plates is taken from the face of the kingpin shaft to the inside edge of the roller wheel

More information

SKiM 63/93 IGBT Modules. Content. Mounting Instruction

SKiM 63/93 IGBT Modules. Content. Mounting Instruction Mounting Instruction SKiM 63/93 IGBT Modules Revision: 1.7 Issue date: 2016-02-26 Prepared by: Anastasia Schiller Approved by: Peter Beckedahl Keyword: SKiM63/93, Mounting Instruction Content 1. Preparation,

More information

Damping Engineering Radial Dampers LD. Radial Dampers LD. Damping Characteristics. Variation Possibilities

Damping Engineering Radial Dampers LD. Radial Dampers LD. Damping Characteristics. Variation Possibilities Patented new development with extremely broad damping range DICTATOR has broken new ground with the LD radial damper. It is an in-house newly developed, patented technology. Its flexible, extremely adaptable

More information

Model 2300DL Installation Guide

Model 2300DL Installation Guide Model 2300DL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300DL

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FD-2A AUTOMATIC RESETTING FIRE DOOR HOIST OPERATOR R US RECOGNIZED COMPONENT CONFORMS TO UL 325 3040233 9045.DWG ECN 0986 REV 2 PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENTS:

More information

TURN-TiLT WiNDOWs A11.16 CHRONO ACCessORies

TURN-TiLT WiNDOWs A11.16 CHRONO ACCessORies A11 TURN-TILT WINDOWS A11.16 CHRONO Accessories 01.02.2014 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. Window stay

More information

XR Conveyor Maintenance Guide

XR Conveyor Maintenance Guide XR Conveyor Maintenance Guide EN-0035 Rev. A XR Conveyor Maintenance Guide www.qdraw.com Table of Contents 05/20/2009 Overview Page 3 XR Conveyor Assembly Page 4 General Information Exploded View of an

More information

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Technical Description GenMan-TEN082730 98-2001230 Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this manual..............................

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

Product features & Overview. N1 - N4 A Rotary and part-turn actuators Product features & Overview N1 - Rotary and part-turn actuators 20 N1 - Rotary and part-turn actuators Rotary and part-turn actuators Product features Wide torque range Wide selection of output shafts

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24 Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24 2 Contents Contents Product Information and Specs. 3 Mechanical 3 Electrical, Line Connections 3 Electrical, Control Connections

More information

Door Closer Solutions

Door Closer Solutions Door Closer Solutions Contents Door Closer Solutions DICTATOR Door Checks from page 02.003.00 Closing Springs Swing Door Hinges from page 02.029.00 Special Door Closers (Tube door closer, DIREKT, from

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax: ARCHITECTURAL SPECIFICATION ED-700 SECTION 08460 Automatic Entrance Doors DORMA Automatics, Inc. Series ED-700 (Surface Applied) LOW ENERGY OPERATING SYSTEM FOR SWINGING DOORS 1.01 SUMMARY: A. Section

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

Maintenance and service manual for elevator control valve

Maintenance and service manual for elevator control valve Maintenance and service manual for elevator control valve EV 100 blain Biofial s.a. Pontou 52 street (behind B K.T.E.O.) P.C. 54628 Thessaloniki Greece Tel: +302310755032 Fax: +302310754929 www.biofial.gr

More information

Diaphragm Valve, Plastic

Diaphragm Valve, Plastic Diaphragm Valve, Plastic Construction The GEMÜ motorized plastic diaphragm valve has a low maintenance electric actuator and a reversible synchronous motor. It is operated via a non-self-locking reduction

More information

TECHNICAL DATA HYDRAULIC UNIT

TECHNICAL DATA HYDRAULIC UNIT GB INSTRUCTIONS MANUAL RISING BOLLARD OIL-HYDRAULIC AUTOMATION COMPONENTS strabuc 918 RELEASE KEY PLUG FOR RELEASE HOLE BOLLARD COVER 12 V WARNING LIGHTS REFLECTORS COMPLETELY RETRACTABLE POST WITH ELECTROPHORESIS

More information

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 1000-X OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S1000X-110 VER0215-1 For information on this product and

More information

SERIES B & C ROLLER DOORS INSTALLATION GUIDE

SERIES B & C ROLLER DOORS INSTALLATION GUIDE SERIES B & C ROLLER DOORS INSTALLATION GUIDE THESE INSTRUCTIONS ARE PROVIDED FOR USE BY EXPERIENCED INSTALLERS OF GARAGE DOORS BY UNDERTAKING THE INSTALLATION OF THIS DOOR, THE INSTALLER UNDERSTANDS THE

More information

Premium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1

Premium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1 Premium Dry Freight (Plywood) Door Installation A Premium door can be identified as usually having a two-spring balancer, 2 diameter (nominal) rollers, and end hinges with removable covers. If your Whiting

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary EA GDE/GLB-2 Description OpenAir direct coupled 24 Vac non-spring return rotary electric actuators are designed for 3-position (floating)

More information

access

access 184 Table of Contents Access Garage door Motors Dexxo Pro 800 RTS... 188 Dexxo Pro 1000 RTS... 189 Dexxo Optimo RTS... 190 Receiver Axroll NS... 191 Freeroll ESE RTS, RTS receiver for roller garage doors...

More information

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI Steca Elektronik INVERTER / CHARGER WITH MPPT: 5000-48 Inverter / Charger with MPPT charge controller All-in-one: 5 kw / 5 kva pure sine wave inverter (10 kw / 10 kva up to 5 s) 80 A MPPT charge controller

More information

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar 4 Function and features K A1 G1 B1 G2 KM Y B2 RE A2 Z S2 A S1 W B KS [ Operation ] [ Operating pressure ] The Eckart rotary-linear actuator HSE4 is a combination

More information

Allegion LCN Benchmark AU9100 Series

Allegion LCN Benchmark AU9100 Series Allegion LCN Benchmark AU9100 Series Low Energy Operators Installation Manual LCN Low Energy Operators should be installed in accordance with the current Allegion LCN installation instructions. Commissioning

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

Model 20 DPS.2005 Doc: J2-20DPS2005/01 Nov 2006

Model 20 DPS.2005 Doc: J2-20DPS2005/01 Nov 2006 Model 20 DPS.2005 Doc: J2-20DPS2005/01 J2-20 IP65 Modulating Electric Actuator Main Features: The maintenance free J2 electric actuator is very user friendly. It offers more standard features than any

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) Installation Guide VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) VICPA222 Technical Data Power 24 Vac ±20%, 50/60 Hz Power consumption 8 VA (running)

More information

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH EN Dusty / Dusty Ex Operating Instructions Low-Cost Broken Bag Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Introduction.............................................................. 3 1.1

More information

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + 8 CABIN DOORS DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

HORIZONTAL SLIDING DOORS

HORIZONTAL SLIDING DOORS HORIZONTAL SLIDING DOORS INSTALLATION MANUAL V2 INSTALLATION MANUAL HERCULES HORIZONTAL SLIDING DOORS OUR COMPLETE LINE TESTED & APPROVED Vertical Lift Bi-Parting Sliding BUILDING CERTIFICATION & GREEN

More information

7100SZ Series SafeZone Installation and Instruction Manual

7100SZ Series SafeZone Installation and Instruction Manual 7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 80-9371-0081-00 (10-10) Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 5 for template) 3 1 Push Side Applications

More information

Speed controller LR36-K-118. Locking device. Torque motor. Electrical connection

Speed controller LR36-K-118. Locking device. Torque motor. Electrical connection ATS00MOF Door drive 10 M12 40 120 56 17,5 6 8 56 Speed controller LR6K118 11,5 242 Locking device Torque motor Electrical connection 210,5 Description Electrical drive for opening fire protection doors

More information

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe

More information

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW BSW 819-492, -493, -494 User's Guide Mechanical Rotary Cam Switches BSW 819-492 BSW 819-493 BSW 819-494 The CE Marking is your guarantee that our products meet the requirements of EC Directive 89/336/EC

More information

RCEL005 / RCEL

RCEL005 / RCEL Top Quality Valve Actuators Made in Sweden RCEL005 / RCEL006-250 High quality electric actuators ROTORK SWEDEN has been manufacturing actuators since 1961 Technical Data RCEL005 RCEL006-250 RCEL series

More information

ARI-PACO Electric thrust actuator

ARI-PACO Electric thrust actuator Electric thrust actuator Electric thrust actuator ARI-PACO ARI-PACO 0,85 kn Electric thrust actuator for Heating-, Ventilation- and Air-Conditioning- Systems, 3... 20 mm travel Thrust 0,85 kn Tightly-closed

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

GL1200T Cut & Seal. (GL1200 Seal only)

GL1200T Cut & Seal. (GL1200 Seal only) GL INSTRUMENTS Technical Description & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions

More information

PRODUCT INFORMATION BULLETIN

PRODUCT INFORMATION BULLETIN 724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DTP. Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl 8600 AD Sneek, Holland

More information

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5 2.22 415 range Features Metal enclosure Two switches in one enclosure Problem-free opening of stressed doors by means of bell-crank system Robust design Long life High holding force 3,500 N Adjustable

More information

Model 2300JL Installation Guide

Model 2300JL Installation Guide Model 2300JL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300JL

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 1. INTRODUCTION 2. SAFETY INSTRUCTIONS 3. SPECIFICATION 4. OPERATING INSTRUCTIONS AND CONTROL FUNCTIONS 5. SET UP PROCEDURE 6. CONNECTIONS

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information