EXAMINATION CERTIFICATE

Size: px
Start display at page:

Download "EXAMINATION CERTIFICATE"

Transcription

1 CGT-02 KDB 04ATEX036 English translation CERTIFICATE [1] EC TYPE EXAMINATION CERTIFICATE [2] Devices, protection systems, parts and sub-assemblies for explosion hazardous areas. Directive 94/9/EC (introduced into polish law by the Order of the Ministry of Economy of Official Journal of the Republic of Poland No. 143, pos. 1393). [3] EC Type examination certificate KDB 04ATEX036 [4] Device: CGT-02 turbine gasmeter [5] Manufacturer: Common S.A. [6] Address: ul. Aleksandrowska 67/93, Łódź [7] The device or protective system subject to this certificate, with its all approved versions, is described in the attachment to this certificate and in the documentation mentioned there. [8] Notified Body No. 1453, according to Article 9 of the Directive 94/9/WE of , certifies that this device or protection system meets the essential health and safety requirements relating to the design and construction of devices and protection systems intended for use in explosion hazardous areas specified in the Attachment 2 to the Directive 94/9/EC (Order of the Ministry of Economy of chapter 2, Official Journal of the Republic of Poland No. 143, pos. 1393). The test and examination results are recorded in the report KDB No [9] Compliance with the essential health and safety requirements has been assured by accordance with the following standards: PN-EN :2003, PN-EN 50014:2002(U), PN-EN 50020:2003(U) [10] X sign given after certificate number states for special conditions of use in explosion hazardous areas, specified in the attachment to this certificate. [11] This EC type examination certificate applies only to the design, evaluation and testing of the device or protection system, according to the Directive 94/9/EC. This certificate does not cover other requirements of the Directive, related to the manufacturing process and introducing into the market. [12] The device or protective system should be marked: II 2G EExiaIIBT4 II 2G EExiaIICT4 Date of issue page 1 of 5 (stamps & signatures)

2 [14] EC Type examination certificate KDB KDB 04ATEX036 [15] Description: Turbine gasmeters are electro-mechanical pressure devices designed for gas volume measurement. They are usually installed in places like rooms, buildings, boxes and enclosures, where explosive mixtures of fumes, gas or mist mixed with air described by explosion classes IIA, IIB & IIC may occur. The principle of operation of turbine gasmeter: impeller rotation speed is proportional to linear speed of gas flow, which means it is proportional to gas volume flux. Incoming gas is guided into measuring cartridge and causes the impeller to rotate. Gear unit and magnetic coupling transfer rotary motion of the rotors to the counterhead. Volume of gas flowing through the meter is summed up and displayed on the 8 digits totalizer. Gasmeter is equipped with electric pulse sensors, powered by intrinsically safe circuits. CGT-02 turbine gasmeters consist of 5 integrated units: main body unit, measuring cartridge, rotation transfer unit, counterhead and lubrication system. Every unit has a metal body, all bodies are connected to each other and the connections resistance is lower that 1MΩ. Main body unit consists of outer body and flow conditioner. Flow conditioner is made of metal or plastic with surface resistance lower than 1 GΩ. There are several connection sockets in outer body, designed for: pressure measurement, temperature measurement, and sensors outputs. There can be maximum 4 HF (high frequency) inductive sensors installed in the gasmeter: - 2 HF sensors taking pulses from impeller - 2 HF sensors taking pulses from reference wheel. Above mentioned pulse sensors should be of at least protection level. Example: - HF sensor type CHFI-02 by Common S.A. ; II 2G EEx ia IIC T6 II 2G EEx ia IIC T5 - HF sensor type NJ1,5-10GM-N-Y07451 by Pepperl+Fuchs GmbH II1GEEx ia IICT6 - HF sensor type Bi1-EH04-Y1 by Hans Turck GmbH ; II 2G EEx ia IIC T6 Allowable supply parameters (of above mentioned sensors) from intrinsically safe circuits, and maximum inductance & maximum self-capacitance of sensors: - CHFI-02 Ui=15,5V, Ii=52mA, Pi=169mW, Li 40µH, Ci=28nF - NJ1,5-10GM-N-Y07451 Ui=16V, Ii=25mA, Pi=64mW, Li=50µH, Ci=20nF - Bi1-EH04-Y1 Ui=15V, Ii=60mA, Pi=80mW, Li=150µH, Ci=150nF Above data is given on the casing of each sensor. (stamp & signature) page 2 of 5

3 [14] EC Type examination certificate KDB KDB 04ATEX036 [15] Description (continued): The measuring cartridge consists of measuring cartridge body, impeller and gear unit. It is mounted in the main gasmeter body. The impeller is positioned in the centre line of gasmeter body, supported by precise ball bearings. Both: measuring cartridge body and impeller are made of aluminium. Gear unit reduces the rotating speed and transfers it to magnetic coupling. Rotation transfer unit connects measuring cartridge unit with counterhead unit, and separates gas zone from environment. Rotation transfer unit consists of base, hermetic (gas tight) barrier and magnetic coupling. Driving part of magnetic coupling is in gas zone and is connected to the impeller by jointed shaft. Driven part of coupling is separated from gas zone by hermetic barrier and is connected to counterhead unit. Counterhead unit consists of lower body, upper body, gears, 8 digit totalizer, and LF and HF sensors with wiring and plugs. Connection between lower and upper bodies assures IP65 protection class. Upper body is fixed to lower body with bolts, and sealed with seals. There can be maximum 6 pulse sensors installed in the counterhead: - two HF high frequency inductive sensors - two LFI low frequency inductive sensors - two LFK low frequency reed contact sensors. Above mentioned pulse sensors should be of at least protection level. Example: II 2G EEx ib IIC T4 - HF sensor type NJ0,8-5GM-N by Pepperl+Fuchs GmbH ; II 1G EEx ia IIC T6 - LFI sensor type CLFI-01 by Common S.A. ; II 2G EEx ia IIC T6 - LFK sensor type CLFK-01 by Common S.A. ; II 2G EEx ia IIC T6 Nameplates are mounted on the upper body of counterhead. Nameplates for use in explosive atmosphere class IIA or IIB, are made of polycarbonate foil glued to metal plate of less than 100 cm 2 area. Nameplates for use in explosive atmosphere class IIC, are made of stainless steel and inscriptions are made by electrochemical etching. Lubrication system consists of hand-driven oil pump and oil container, it is meant for impeller bearings lubrication. Other CGT-02 mechanisms (and DN50 impeller bearings) are not lubricated using oil pump they are equipped with self-lubricating bearings. Oil container is made of transparent plastic and it has outer body made of metal against electrostatic charge accumulation. (stamp & signature) page 3 of 5

4 [14] EC Type examination certificate KDB 04ATEX036 [15] Description (continued): Technical parameters: Ambient temperature: -25 C +70 C Body protection level: IP65 Intrinsic safety parameters: HF U i = 16 V DC I i = 25 ma P i = 64 mw L i = 50 µh C i = 30 nf pulse sensor type LFI U i = 15,5 V DC I i = 52 ma P i = 169 mw L i 40 µh C i = 28 nf LFK U i = 15,5 V DC I i = 52 ma P i = 169 mw L i 0 C i 0 (stamp) page 4 of 5

5 [14] EC Type examination certificate KDB 04ATEX036 [16] Test report: Test report KDB No [17] Special conditions of use: none [18] Essential health and safety requirements: Assured by the compliance with the standards mentioned in point 9 of this certificate. [19] Documentation specification: Documentation specification CGT-02 turbine gasmeters description Gasmeter structure CGT-02 gasmeters technical data CGT-02 gasmeters dimensions Bill of materials Sensors position in gasmeter body HF sensor taking pulses from impeller type I HF sensor taking pulses from impeller type II HF sensor taking pulses from reference wheel Counterhead unit structure Sensors position in counterhead unit Different sensors-to-plugs connection versions Name plates Technical data of parts & units Manual CGT/A04-00 CGT/A04-01 CGT/A04-02 CGT/A04-03 CGT/A04-04 CGT/A04-05 CGT/A04-06 CHF/A04-01 CHF/A04-02 CHF/A04-03 CZL/A04-01 CZL/A04-02 CZL/A04-03 CGT/A04-07 CGT/ELH04 CGT/IU04 (stamp) Page 5 of 5

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1. (13) SCHEDULE (14) to EC- Examination Certificate KEMA 04ATEX1152 X Issue No. 5 (15) Description Two Wire Proximity Sensors with digital output signal...-.-.ay1..-.. /. and...-.-.ry1..-.. /. are used for

More information

Attachment to Certificate IECEx PTB X

Attachment to Certificate IECEx PTB X Applicant: Electrical Apparatus: Pepperl + Fuchs GmbH Cuboidal inductive proximity sensors Types Fj, NJ, NB and NC The cuboidal inductive proximity sensors of types Fj, NJ, NB and NC are used to convert

More information

The filling level sensors are designed in accordance to the following standards

The filling level sensors are designed in accordance to the following standards Instructions according to Portaria N 179/2010 UL-BR 17.0706 Filling Level Sensors type VISY-Stick and type TORRIX Ex Version: 09.2017 I Range of application The filling level sensors are designed for continuous

More information

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2012-06-12 Issue No.: 3 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Germany Manufacturing

More information

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858 Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858 Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO

More information

Quantometer MZ. Description

Quantometer MZ. Description Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Volumeter. RMG Meßtechnik GmbH. Publication No E

Volumeter. RMG Meßtechnik GmbH. Publication No E Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Flap-Type Flow Meter Prall

Flap-Type Flow Meter Prall Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

IBExU Institut für Sicherheitstechnik GmbH

IBExU Institut für Sicherheitstechnik GmbH [1] EC-TYPE EXAMINATION CERTIICATE according to Directive 94/9/EC, Annex 111 [2] Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres, Directive 94/9/EC [3] EC-Type Examination

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

General Specifications

General Specifications General Specifications Model RAGG Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in

More information

RMG Meßtechnik GmbH. Publication No E

RMG Meßtechnik GmbH. Publication No E Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

K - Flow Meter with Float

K - Flow Meter with Float K - Flow Meter with Float Doc. no.: 18, en_cat_k, 12/2014, rev. 1 Application All-metal flow meters with float type K are used for signaling and measuring of instant flow, flowed volume of liquid and fluent

More information

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 12.3.2013 Internet: www.labkotec.com 1/12 WBS 3000 Water Bottom Sensor for fuel oil and chemical storage

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR LOR STER INDUSTRIL UTOMTION Intrinsically safe barrier with separation FIELDUS TRNSMISSION LINES CONVERTER-SEPRTOR type SEx-RS RS/RS, RS/, /RS, /, RS/RS - group I, category M and group II and III, category

More information

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift 90 D C MZ 002-099-4115 Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift CE Certificate of Conformity Actaris Gaszählerbau GmbH 76161 Karlsruhe

More information

Type 4746 Electric or Pneumatic Limit Switch

Type 4746 Electric or Pneumatic Limit Switch Type 4746 Electric or Pneumatic Limit Switch Application Limit switches with inductive, electric or pneumatic contacts for attachment to pneumatic or electric control valves, to Type 4763 Electropneumatic

More information

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications

More information

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM Operating Instructions for Viscosity Compensated Flow Meter / Monitor Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Use in Hazardous Areas...

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Control Panels, Distribution Panels and Components

Control Panels, Distribution Panels and Components 11 Control Panels, Distribution Panels and Components EEx d Enclosures in Light Metal or stainless steel Flexible modular design for combining enclosures Can be used in Zone 1 and Zone 2 in Zone 21 and

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 4 6. Use in Hazardous

More information

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift FLUXI 2000/TZ 652-099-2025 Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift ANNEX 6: CE Certificate of Conformity declares that the product:

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It

More information

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal

More information

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME MASZYNY ELEKTRYCZNE CELMA SA ISO 9001: 2000 ISO 14001 THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME 80 132 Type: ECS(K,L,1)g, ECS(K,L,1)gb CS(K,L,1)g, CS(K,L,1)gb GENERAL INFORMATION

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

Safety Instructions Proline Promass 300

Safety Instructions Proline Promass 300 XA01472D/06/EN/01.16 71327890 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 1, AEx/Ex de ia IIC/IIB Class I, Zone 1, AEx/Ex d ia IIC/IIB Zone 21, AEx/Ex tb IIIC Txx

More information

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION 1. GENERAL INFORMATION The MICROSOL intrinsic safety solenoid valves produced by Fluid Automation Systems SA are dedicated to piloting fluids in explosive atmospheres according to the ATEX 94/9/CE directive,

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed

More information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information 00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled

More information

Annex 1 to Certificate of Conformity IECEx KEM X, issue 4 Annex 1 to IECEx Test report NL/KEM/ExTR /04 Annex 1 to KEMA 02ATEX1090 X, issu

Annex 1 to Certificate of Conformity IECEx KEM X, issue 4 Annex 1 to IECEx Test report NL/KEM/ExTR /04 Annex 1 to KEMA 02ATEX1090 X, issu Annex 1 to Certificate of Conformity IECEx KEM 06.0036X, issue 4 Annex 1 to IECEx Test report NL/KEM/ExTR06.0032/04 Annex 1 to KEMA 02ATEX1090 X, issue 7 T... -. -. Y1. -.. /. Identification of special

More information

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water. Technical Datasheet

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water.  Technical Datasheet www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet HM...TC-R Turbine Flow Meters for Solvents and Di-Water HMTC-R_D_E_150128_E003 Application Turbine flow meters serve to accurate

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Valve Position Monitors

Valve Position Monitors Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X 1 LIMIT SWITCHES Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1345550 (LR 36637) Master Contract: 152423 Issued to: Measurement Technology Limited Great Marlings Butterfield Luton, Bedfordshire LU2 8DL United Kingdom Attention:

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

Series Level-Trol Electronic Liquid Level Transmitters

Series Level-Trol Electronic Liquid Level Transmitters 0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring

More information

Capacitive level sensors CLS 23

Capacitive level sensors CLS 23 For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg REPORT IB-07-8-003 about the experimental testing of enclosed-break devices Thermostat type 077Bxxxx/L

More information

Modern Explosion Protection

Modern Explosion Protection Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Modern Explosion Protection ATEX valves for use in industrial

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C) Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.

More information

The overfill prevention sensor GWG with tube plug type 907. More than 25 years of FAFNIRexperience. Integrated QSS and ASS function

The overfill prevention sensor GWG with tube plug type 907. More than 25 years of FAFNIRexperience. Integrated QSS and ASS function The Overfill Prevention Sensor GWG and QSS/ASS Plugs The filling sensor is a safety mechanism to prevent overfilling of storage and bunker tanks when they are filled with gasoline, diesel, and fuel oil

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

MAGNETIC FLOAT SWITCH

MAGNETIC FLOAT SWITCH INSTALLATION AND OPERATING INSTRUCTIONS MAGNETIC FLOAT SWITCH 1. FUNCTIONAL DESCRIPTION: 2 2. AREA OF APPLICATION: 2 3. ASSEMBLY: 2 4. HAZARD NOTICES: 2 5. ELECTRICAL CONNECTION: 2 6. OPTIONS: 3 7. CAUTION:

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

High Precision Turbine Wheel Flow Meter for Liquids

High Precision Turbine Wheel Flow Meter for Liquids High Precision Turbine Wheel Flow Meter for Liquids measuring monitoring analysing Measuring ranges: 0.006-0.1 to 10-500 L/min water Measuring accuracy: ± 1.25% f. s. pmax: 345 bar; tmax: 135 C Viscosity

More information

Note: Boldrin reserves the right, to modify the gas meters without changing the request concerning accuracy and security. page 2

Note: Boldrin reserves the right, to modify the gas meters without changing the request concerning accuracy and security. page 2 Manual 0. List of contents 1. Design and Function 1.1. Description 1.2. Function 1.3. Meter sizes 1.4. Dimensions 1.5. Construction 1.5.1. Main housing 1.5.2. Measuring cartridge 1.5.3. Counter head 1.5.4.

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Limit Switches. Series NI700 Installation, Maintenance and Operating Instructions

Limit Switches. Series NI700 Installation, Maintenance and Operating Instructions Limit Switches Series NI700 Installation, Maintenance and Operating Instructions 7 NI 72 en 12/2008 2 7 NI 72 en Table of Contents 1 INTRODUCTION... 3 1.1 General description... 3 1.2 Markings... 3 1.3

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use

More information

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102 No. SS2-SVX100-0100 Smart Valve explorer Smart Valve Positioner for Rotary Valve Model SVX100 / SVX102 OVERVIEW Smart Valve explorer (SVX) models SVX100 and SVX102 are microprocessor-equipped, currentpneumatic

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors

More information

Delta Commercial & Industrial Rotary Meter

Delta Commercial & Industrial Rotary Meter Delta Commercial & Industrial Rotary Meter Itron's Delta range of rotary gas meters comprises innovative and high quality products. Characterized by compact dimensions and easy maintenance, the Delta

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Turbine flowmeters Series TM

Turbine flowmeters Series TM Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure

More information

PRODUCT INFORMATION. Monitoring device ARM-2000

PRODUCT INFORMATION. Monitoring device ARM-2000 PRODUCT INFORMATION Monitoring device ARM-2000 Description The objective of monitoring HERMETIC canned motor pumps are thoroughly inspected and tested before shipment. An integral part of the test is the

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1. SPECIFICATIONS MEASUREMENT SOLUTIONS MV Series Bulletin SS02016 Issue/Rev. 1.7 (9/14) We put you first. And keep you ahead. SMITH METER TURBINE METERS The Smith Meter MV Series Turbine Meter is intended

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve

More information

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact

More information

Flow Sensors & Instruments

Flow Sensors & Instruments STAINESS STEE TURBINE FOWMETERS Serie X IG PRESSURE AND IG TEMPERATURE Principle of Operation The x range of Turbine Flowmeters meet the demand of most liquid measurement applications. They basically consist

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

Accessories Cable glands

Accessories Cable glands Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:

More information

General Specifications

General Specifications General Specifications Model RAGK Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

TORRIX Magnetostrictive level sensor

TORRIX Magnetostrictive level sensor TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over

More information

General Specifications

General Specifications General Specifications Model RAGG Rotameter GS 01R01B06-00E-E This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float

More information

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008 Data Sheet GT1000 Series Brooks GT1000 Series Industrial Glass Tube Variable Area Flowmeters Model GT1020 Model GT1024 DESIGN FEATURES Brass or 316L SS (1.4404) end fittings Flanged or threaded connections

More information

Wolflite XT Rechargeable LED Handlamp

Wolflite XT Rechargeable LED Handlamp Wolflite XT Rechargeable LED Handlamp Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Wolflite XT Rechargeable Handlamp exploits advanced technology to deliver excellent performance,