Vacuum Producers. Vacuum Producers

Size: px
Start display at page:

Download "Vacuum Producers. Vacuum Producers"

Transcription

1

2

3 Vacuum roducers Vacuum roducers 7

4 Vacuum roducers About Vacuum roducers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. In Dustcontrol extraction systems, the vacuum level is gene rally from ka. Our normal source extraction and vacuum cleaning systems use turbopumps. This device has an ideally suited characteristic capacity for this type of system. Vacuum level increases as more resistance is pre sented, an important quality in minimizing the possibility of blockages in the tubing system. For applications involving fume and light dust, such as paper, radial blowers are used. These have larger air-flows and operate at a lower, relatively constant, vacuum level. Our turbopumps and radial blowers have very high quality silencing, see technical speci fications. Turbopumps Dustcontrol s turbopumps are regener ative blowers, both the direct and belt driven models. As the impeller rotates, centrifugal force moves the air from the root of the blade to the tip. Leaving the tip, air flows around the contour of the housing and is picked up at the root of the succeeding blade. The closed area of the housing between the outlet and inlet, forces the air to atmosphere. The many blades on the impeller create increasing stages of pressure generation and result in a very stable pressure differential capability. This pressure generation causes heat to be generated naturally which dissipates in the air flow and through the blower housing. Silencing, particularly on the larger units is very effective.when two or more units are installed in parallel, they can be operated on demand for maximum efficiency and minimum energy consumption. Radial Blowers Dustcontrol fans are radial blowers, air is introduced at the center of the fan wheel and forced outward with centrifugal force toward the fan housing. These fans can be operated fully restricted in a free-wheel ing condition without adverse effect and can therefore be operated without vacuum relief valves. The fans are designed for pressure and are overloading type units. They cannot be operated without being connected to the restriction of a tubing system. Operation above their maximum rated flow will result in overloading and the motor protection will trip out. To limit the power surge at start-up, install a shutter valve on the inlet which should be closed when the fan starts.

5 Vacuum roducers Turbopumps Source Extraction, Cleaning, neu matic Trans portation. ka ka 1 p 1 1 p Hz ka p 5 Hz, Hz Hz m /h m /h TLD.. TED 5.5. TSD 9./11. TD 9./11 5. TLD H. TED H TSD 15 H. TD 15 H 9. TR TR TR m /h 1. TSR TR 7 1. TSR TR 5 1. TSR 5 Radial Blowers Fume extraction of fine dust from light material, ie: wood and paper. ka 1 1 p m /h 17. RAF 5 1. RAF 5 S 19. RAF 1. RAF 5 1. RAF 51. RAF 5. RAF 5 Silencer The capacity curves for Dustcontrol vacuum producers have been measured and are stated empirically. Outlet pressure losses from a normal outlet (silencer, back-flow valve/bend) have been accounted for in the curve. Additional equipment such as a diffuser can result in increased pressure loss and must be taken into consideration. Stated air-flows are for standard air (1. ka@ C). The stated curves are for negative application, all pressures stated are assumed to be below relative atmospheric pressure at sea level. These devices can also be used for positive pressure application and will generate a greater pressure differential. 9

6 Vacuum roducers TLD/TED / Turbopump TLD / and TED / are direct driven single stage units. To ensure constant pressure and that cooling air is available to the pump when all outlets are closed, the tubing system should be equipped with a vacuum relief valve. TD / Turbopump TD / is a direct driven twin impeller parallel series con nected unit. To ensure constant pres sure and that cooling air is avail - able to the pump when all outlets are closed, the tubing system should be equipped with a vacuum relief valve. TSD / Turbopumps TSD / are direct driven twin impeller series connected units. This is used in demand ing applications where high vacuum levels are required. To ensure that cooling air is available to the pump when all outlets are closed, the turbo-pump can be equipped with a cooling air inlet. art No Hz TLD TLD TED TED TD TSD TSD TD. H 5.5 H H S 15 H / V 5 V V / V 19 V US/CAN V CAN TD / TED / TSD / TLD / LUBRICATION INTERVAL TLD TLD TED TED TD TSD TSD TD. H 5.5 H 9./11 9./11 15 H 15 H h h h h 15 h 15 h 15 h 15 h g Grease Cartridge for Dustcontrol Turbopumps, art No 99 These direct driven units are extremely reliable and have low service requirements. Always change the O Ring when repacking the outboard bearing in the TSD and TD pump.

7 TECHNICAL DATA, description TLD TLD TED TED TD TSD TSD TD ower Supply Hz ump RM Weight kg Max d ka * * * 1* Nominal ressure ka Max m /h Sound Level of Unit 1m db(a) Inlet/Outlet Ø mm 5/5 5/5 / / / / / / * Standard DC Green System Max ka Vacuum roducers Capacity and ower Consumption ka u Hz 1. TLD.. TED 5.5. TSD 9./11 * ). TD 9./11 m /h Accessories art No 7 Console 5 mm ( req d) For wall installation of TLD /. art No 77 ump Chassis For separate mounting of TED /, TD / and TSD /. art No 9 Silencer / Used for silencing of 7 mm vacuum valve and also exhaust silencing on.5 11 / 1.9 H turbopump. For accompanying tubing details, see installation example. art No 195 Silencer /1 Used for silencing of 5 mm vacuum valve. art No 5 Vacuum Relief Valve 5 mm Used with TLD /. The vacuum relief valve is installed on the tubing system (inlet side) on a branch tube. This delivers cooling air to the turbopump and can be adjusted for the desired vacuum level in the system. art No 1 Vacuum Relief Valve 7 mm Used with TED / and TD /. The vacuum relief valve is installed on the tubing system (inlet side) on a branch tube. This delivers cooling air to the turbopump and can be adjusted for the desired vacuum level in the system. art No 595 Cooling air inlet with silencer for TSD / Cooling air is introduced to the turbopump between stages so the unit can be driven with all outlets closed without the risk of overheating. art No 97 Back Flow Valve Ø Installed on the inlet side of the turbopump when two or more units are parallel installed. Silencing Covers. The silencing covers will reduce the sound level by db. art No 1 Silencing Cover for TLD art No 97 Silencing Cover for TED 5.5 art No 9 Silencing Cover for TED 9. art No 59 Intermediate piece Ø /195 ka 1 TLD / Hz u 5. TLD H. TED H 7. TSD 15 H * ) 7. TD 15 H 5 5 TD / TED / TSD / m /h Figure shows available capacity in an extraction system. * ) Turbopump with cooling air inlet. Installation Example, Silencers 1 1

8 Vacuum roducers TR Turbopumps with TR designation are parallel connected twin impeller belt driven units. Cooling air is introduced into the unit through an adjustable vacuum relief valve. The vacuum pressure in the system can be held constant when different outlets are opened. The turbopumps are equipped with thermal overload protection on the outboard bearing which will trip out when bearing temperature becomes excessive. A back flow valve is built into the unit on the inlet side. TSR Turbopumps with TSR designation are series connected two stage belt driven units. Cooling air is introduced into the pump through a slot between the two stages. In this way the second stage cools the first stage indirectly, allowing the pump to run at extremely high vacuum and low airflow without overheating. The turbopumps are equipped with thermal overload protection on the outboard bearing which will trip out when bearing temperature becomes excessive. A back flow valve must be optionally installed on the inlet side of the unit when several units are to be installed in parallel. Dimensions, Installation Example TR TSR ART NO/MOTOR Hz TR 5 TR TR TSR TR 7 TSR 7/ TR 5 TSR 5/5 V 5 /15 7/1.5 75/1.5 77/ 775/ 9/ 95/ V 5 /11 /15 7/1.5 75/1.5 77/ 775/ 9/ 95/ V USA/CAN 5/ H 77/5 H 757/5 H 777/ H 7757/ H 97/ H 957/ H V CAN / H 7/5 H 75/5 H 77/ H 775/ H 9/ H 95/ H

9 Vacuum roducers TECHNICAL DATA, description TR 5 TR TR TSR TR 7 TSR 7/ TR 5 TSR 5/5 ump RM rpm Weight kg Max d ka * * 9* 5 * 5 Nominal ressure ka Max m /h Sound Level of Unit 1 m db(a) Inlet/Outlet Ømm 1/1 1/1 1/1 / 1/1 / 1/1 / * Standard DC Green System Max ka Capacity and ower Consumption The diagram shows available capacity for an extraction system. ka 5 u TR 5. TR. TR. TSR 5. TR 7. TSR 7/ 7. TR 5. TSR 5/5 m /h p TR 5 TR TR TSR TR 7 TSR 7/ TR 5 TSR 5/5 Lubrication Interval ka 15 h 15 h 15 h 15 h 15 h 5 ka 75 h 75 h 15 h 15 h 15 h ka h h h ka 15 h 15 h 75 h 15 h ka h h h Grease for Dustcontrol Turbopumps, art No 99 Accessories Silencer art No Conn Dimensions 1 Ø1 L=1, Ø55 1 Ø1 L=, Ø55 1 Ø1 L=, Ø art No 51 Back Flow Valve 1 mm Installed on the inlet side of the TSR when two or more units are parallel installed. A art No A 75 db(a) 1 db(a) 1 db(a)

10 Radial blowers RAF 5 Vacuum roducers The RAF 5 is ideal for small fume extraction systems, for example with Flexpipes. Spiral tubing is generally used. The blower is a direct driven unit with minimal service requirements. (Lubrication interval hours.) Without Silencing Enclosure: art No / V, 5 Hz art No 1119 H V, Hz Can/US art No 1119 H V, Hz Can With Silencing Enclosure: art No , / V, 5 Hz art No H V, Hz Can/US Dimensions RAF 5 without Silencing Enclosure Wall installation Floor installation Spacer x 7 Dimensions RAF 5 with Silencing Enclosure and RAF 5 S RAF 5 S The RAF 5S is for application in extraction systems for lighter dust, ie: wood dust. It is a twin wheel, series connected unit. The unit is direct drive and has minimal service requirements. (Lubrication interval hours.) Without Silencing Enclosure: art No / V, 5 Hz art No 111 H V, Hz Can/US With Silencing Enclosure: art No , / V, 5 Hz art No 1111 H V, Hz Can/US Accessories RAF 5 and RAF 5S art No 7 Silencer, / mm Used for silencing exhaust and inlet. art No 97 Back Flow Valve mm Installed on the inlet side of the fan when two or more units are parallel installed. art No Shutter valve auto mm art No Solenoid valve VAC A closed shutter valve on the inlet at start-up decreases the power surge. TECHNICAL DATA RAF 5 RAF 5S Motor.5 / H 5.5 / H ump RM rpm Weight kg 9 15 Max dp ka Max m/h 9 1 Sound Level * ) db(a) without silencing enclosure with silencing enclosure Inlet/Outlet mm /7 / 97 7 ka u 1 5 A B C D RAF RAF 5S Capacity and ower Consumption RAF 5 RAF 5 RAF 5S m /h RAF 5S Figure shows available capacity in an extraction system. * ) with exhaust silencer, 1 m

11 Vacuum roducers RAF 1/5 ART NO Hz RAF 1 RAF 5 V , V , V US/CAN 117 H 117 H V CAN 11 H 11 5 H RAF 1/5 are single stage direct driven radial blowers for less demand ing pressure applications such as fume extraction. The blowers are equipped with vibration isolators and silenced enclosure. They should always be equip ped with an exhaust silencer (inlet also if required). These units have minimal service requirements (lubrication interval hours). Accessories art No 51 Back Flow Valve 1 mm Installed on the inlet side of the fan when two or more units are parallel installed. art No 75 Shutter valve auto mm art No Solenoid valve VAC A closed shutter valve on the inlet at start-up decreases the power surge. Dimensions, Installation Example Capacity and ower Consumption ka u TECHNICAL DATA RAF 1 RAF 5 5Hz Hz 5Hz Hz RAF 1 RAF 5 ump RM rpm Weight ca kg 9 Max dp ka Max m /h 5 Sound Level* db(a) 7 Inlet/Outlet mm /1 /1 * with exhaust silencer, 1 m. RAF 1 Figure shows available capacity in an extraction system. m /h RAF 5 5

12 Vacuum roducers RAF 51 V Hz Motor art No USA/CAN H 11 H 11 The RAF 51 is applied in extraction systems requiring large air-flows for lighter types of dust and cleaning. ressure gene ration is achieved through two series connected stages. The unit is equipped with vibration isolation and a silenced enclosure. The unit should always be equipped with an exhaust silencer (inlet also if required). The unit is direct driven and has minimal service requirements (lubrication interval hours). Accessories art No 51 Back Flow Valve 1 mm Installed on the inlet side of the fan when two or more units are parallel installed. art No 75 Shutter valve auto mm art No Solenoid valve VAC A closed shutter valve on the inlet at start-up decreases the power surge. RAF 5 V Hz Motor art No USA/CAN H 11 H 11 RAF 51/RAF 5 RAF 5 The RAF 5 is applied in extraction systems requiring large air-flows such as systems for fume extraction. RAF 5 work with two parallel impellers. The unit is equipped with vibration isolation and a silenced enclosure. The unit should always be equipped with an exhaust silencer (inlet also if required). The unit is direct driven and has minimal service requirements (lubrication interval hours). RAF 5 V Hz art No 5 11 ressure gene ration is achieved through two series connected stages. The unit is equipped with vibration isolation and a silenced enclosure. The unit should always be equipped with an exhaust silencer (inlet also if required). The unit is direct driven and has minimal service requirements (lubrication interval hours). RAF 5 developes a maximum negative pressure of ka. Note though that the maximum airflow is m /h. Above this, the power consumption would be too large for the motor, so the design of the system must throttle to this level for all cases. Accessories lease see RAF 51. TECHNICAL DATA RAF 51 RAF 5 RAF 5 5Hz Hz 5Hz Hz 5 Hz ump RM rpm Weight ca kg 5 Max dp ka Max m /h Sound Level* db(a) Inlet/Outlet mm /1 x/x1 /1 * with exhaust silencer, 1 m.

13 Vacuum roducers Capacity and ower Consumption ka 1 u RAF5 1 RAF51 RAF5 5 m /h RAF51 RAF5 RAF5 Figure shows available capacity in an extraction system. 1 Fan Silencers In order to decrease the noise level of our fans, RAF 1 5, an in-line silencer must be installed on the exhaust duct. Several examples are illustrated of how noise level measurements can be affected. It is not unusual to obtain measurements of up to 1 1 db(a) in completely non-silenced installations. art No Conn. Dimensions 1 Ø1 L=1, Ø55 mm 1 Ø1 L=, Ø55 mm 1 Ø1 L=, Ø mm Silencer Ø1 x x (art No 1) Ø 1 Ø Silencer Ø1 x 1 x (art No. 1) Ø

14 Vacuum roducers Installation Examples TR 5 TR 5, S S, F S, RAF 5 S F S S TR 5 TR 5 RAF 5 TR 5 TR 5 S S S RAF 5 F RAF 51, S RAF 5, S X S X S RAF 51 RAF 5 RAF 51 S S X RAF 5

15

16

Vacuum Producers. The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system.

Vacuum Producers. The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. Vacuum Producers The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. 23 About Vacuum Producers The heart of the system The vacuum producer is the

More information

About Vacuum Producers

About Vacuum Producers Vacuum Producers About Vacuum Producers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. In Dustcontrol extraction systems,

More information

5 Compact Vacuum Systems. Compact Vacuum Systems

5 Compact Vacuum Systems. Compact Vacuum Systems Compact Vacuum Systems Compact Vacuum Systems 7 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about

More information

Compact Vacuum Systems

Compact Vacuum Systems Compact Vacuum Systems 6 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about every kind of dust

More information

About Dustcontrol Filter Units

About Dustcontrol Filter Units An extraction system should always be equipped with a filter unit. The filter unit separates coarse material in the cyclone body of the unit and fine dust in an internal arrangement of conical pleated

More information

Industry. We call it Healthy Business.

Industry. We call it Healthy Business. Industry Removing dust from the workplace is not just a working environment and health issue, it is also a business issue. The cleaner the working environment, the better the end result. We call it Healthy

More information

About Pre-Separators. When a Pre-Separator is to be used the following should be considered: Pre-Separators should be used: Dustcontrol Pre-Separators

About Pre-Separators. When a Pre-Separator is to be used the following should be considered: Pre-Separators should be used: Dustcontrol Pre-Separators Pre-Separators When large quantities of material are to be separated, it is advisable to use a pre-separator. The pre-separator can be placed at the workplace or in conjunction with the central unit. 49

More information

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE COMPARISON Blowers Exhausters Page 1 of 6 Technical comparison... P 4 Positive Displacement blowers (PD), as the name implies, compress an incremental volume of gas between the inlet and outlet of the

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D045M, E045... 6 D05M, E05... 7 D052M, E052... 8 D060, E060... 9 D064, E064... 10 D066, E066...

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

Side Channel Blowers & Turboblowers

Side Channel Blowers & Turboblowers 1406 Side Channel Blowers & Turboblowers ENGINEERING & TRADING COMPANY Phone +45 4386 8333. Fax +45 4386 8388. e-mail: klee@klee.dk. www.klee.dk Index Side Channel Blowers Characteristics page 5 Application

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications

More information

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package. 5H Z VERSION Experts in Spray Technology Spray Nozzles Spray Control Spray Analysis Spray Fabrication WindJet Air Knife Packages Deliver superior blowing and drying performance in a complete, customizable

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps Page M-M MTH PUMPS M L Series - Hz Metric Edition Multistage Regenerative Turbine Pumps Capacities to LPM Heads to 6 Meters Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic new CA V E RANGE In-line centrifugal fans in self-extinguishing plastic Suitable for the continuous or intensive ventilation of medium or large domestic, commercial or industrial environments. 7 models:

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 Bild fehlt noch DIAPHRAGM PUMPS SLL series 8 EL-N series 9 EL-S series single system 1 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 5 Applications Water treatment and environmental

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

M50 L50 Series Multistage Regenerative Turbine Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps Page M- MTH PUMPS M L Series Multistage Regenerative Turbine Pumps Capacities to 4 GPM Heads to Feet Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal Close Coupled Horizontal

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum

More information

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control

More information

SIDE CHANNEL BLOWERS

SIDE CHANNEL BLOWERS SIDE CHANNEL BLOWERS RT-1 / RT-2 / RT-3 / RT-4 series 23 RT-4 / RT-5 / RT-6 / RT-7 / RT-8 / RT-9 series 24 RT-23 / RT-33 / RT-43 / RT-63 / RT-83 series 25 19 Applications Aeration Swiing pools and whirlpools

More information

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL Absorptive Silencers s UIVERSAL EERGY EVIROMETAL The absorptive type silencer is the classic dissipative design that absorbs noise energy by the use of various types of fibrous packing materials. As sound

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

Model Number Structure

Model Number Structure Solid State Relays Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing Soldering/Desoldering Convection Rework Fume Extraction Fluid Dispensing www.beasuperproducer.com BVX-100 Benchtop Single User Arm/Plenum System Portable, single user fume extraction system Low noise unit

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS APPENDIX A 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS The Technology Center of DuPage is seeking bids for fifteen (15) dual weld stations (total of 30 individual welding booths) with fume

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content: LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D05M, E05... 6 D052M, E052... 7 D060, E060... 8 D064, E064... 9 D066, E066... 10 D07, D072...

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans. 4 AC Fans AC Fans Overview 7 AC Axial Fans 8 AC Radial Fans 38 AC Radial Fans AC Axial Fans AC Fans ACmaxx Axial Fans Technology DC Axial Fans Specials DC Radial Fans 5 Accessories AC Fans Technical Informations

More information

Overview of Blower Technologies and Comparison of High-Speed Turbo Blowers

Overview of Blower Technologies and Comparison of High-Speed Turbo Blowers Math and Maintenance for Pumps and Blowers Overview of Blower Technologies and Comparison of High-Speed Turbo Blowers Juan Loera, P.E. Carollo Engineers Today s Buzzword in Wastewater Treatment High Speed

More information

SINGLE STAGE TWO STAGES

SINGLE STAGE TWO STAGES BLOWERS CATALOG Table of contents SINGLE STAGE TWO STAGES 3 4 1 1 5 6 7 8 9 10 11 12 Weight (Kg) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2RSC 50-65 Performance curve for Vacuum

More information

scfm (6.5 psi) Max HP

scfm (6.5 psi) Max HP Direct Drive, Energy Efficient, High- Speed Turbo Blowers Alvin C. Firmin, PE, BCEE Presented at: PNCWA 2009 Annual Conference Boise, Idaho September 16, 2009 Introduction of Blower Technologies PD Blowers

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

series RVV Variable flow rate controllers

series RVV Variable flow rate controllers series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate

More information

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355. Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection

More information

KV sileo 100 M. Circular duct fans. Circular duct fans

KV sileo 100 M. Circular duct fans. Circular duct fans KV sileo 100 M Speed-controllable Integral thermal contacts Can be installed in any position Can be installed outdoors Maintenance-free and reliable Electrical accessories RE p. 20 The K series is designed

More information

Side channel blowers

Side channel blowers 19 Side channel blowers 20 Characteristics Quiet Equipped with low-noise, high-efficiency IP54 induction motor and specially designed mufflers, all blower series feature quiet operation. Type number Types

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax F. Modular dust collector with integrated pre-separator. Models Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum Pump

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

Series

Series MTH PUMPS 15 25 26 17 27 Series Flexible Coupled Capacities to 15 GPM Heads to 115 Feet Low NPSH Requirements Page 1-19 15 17 25 26 27 LIMITATIONS Discharge Pressure Seal Pressure* Suction Pressure (Min.)

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin 40 October 008 40 40 80 80 Series Regenerative Turbine Pumps Capacities to 60 GPM Heads to 800 Feet MTH PUMPS 40 40 80 80 Series regenerative turbine pumps represent the most economical, high

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315 Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7 W1860BE.book Page 7 Tuesday, January 28, 2003 11:01 PM 3. Fuel System A: GENERAL The fuel pressurized by the fuel tank inside pump is delivered to each fuel injector by way of the fuel pipe and fuel filter.

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

FilterBox Wall. Automatically or manually cleaned for dust & fume applications. Automatically or manually cleaned for dust & fume applications. FilterBox Wall can come with or without a attached. The models without a are suitable for installations with an external and contactor, and

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes Product information - Version 4 BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes Table of contents Economic considerations... 4 Choice

More information

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust. VARIO VARIO Separation of fine dust particles The VARIO series is particularly suitable for separation of fine dust. The VARIO units are of modular construction in order to meet different requirements,

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

PRECISION UK Ltd DUPLEX AGSS PLANT

PRECISION UK Ltd DUPLEX AGSS PLANT DUPLEX AGSS PLANT Contents Page Section Page Product Description General 3 AGSS Plant 3 AGSS Remote Switch 3 Operation General 4 Safety General 5 Installation General 5 Mechanical 5 Electrical 7 Wiring

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

3000W HF/PFC Battery Charger

3000W HF/PFC Battery Charger 3000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments > 0.98 Power

More information

Dalamatic Cased Dust Filters Series DLM 15

Dalamatic Cased Dust Filters Series DLM 15 Dalamatic Cased Dust Filters Series DLM 8 1 bank 1100 2 bank 2105 3 bank 3110 1005 1005 5 5 290 700 2285 10 1360 (17 required for maintenance) 600 required for maintenance 465 (4- to 8-tier) 235 (2- &

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

Agilent Turbo-V 750 and Turbo-V 850 TwisTorr. The new molecular-drag Technology

Agilent Turbo-V 750 and Turbo-V 850 TwisTorr. The new molecular-drag Technology Agilent Turbo-V 75 and Turbo-V 85 TwisTorr The new molecular-drag Technology The new molecular-drag technology What is TwisTorr 2 Agilent Technologies, presents the new TwisTorr molecular drag technology

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin 0 0 2 0 2 170 270 Series Regenerative Turbine Pumps Capacities to 0 GPM Heads to Feet MTH PUMPS 0 2 0 2 170 270 Series Regenerative Turbine Pump MTH 0 2 0 2 170 270 Series regenerative turbine

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information