Electrical operating instructions

Size: px
Start display at page:

Download "Electrical operating instructions"

Transcription

1 en Electrical operating instructions Door control panel TS 981 FT Software (Design and functions subject to change) f

2 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION ADVICE...6 INSTALLATION OVERVIEW...7 ENCLOSURE INSTALLATION...8 CONNECTING THE CONTROL AND THE ELEKTROMATEN...8 MAINS SUPPLY...9 PHASE ROTATION...10 MOTOR CONNECTION (internal wiring)...10 RAPID ADJUSTMENT OF THE LIMITS...11 HARDWARE OVERVIEW...12 WIRING DIAGRAM...14 CONTROL PROGRAMMING...16 Operating mode...17 Door position...17 Functions...18 Safety functions...19 Settings only for ELEKTROMATEN frequency inverter FI...20 Extended door functions...21 Maintenance cycle counter...22 MEMORY CHECK...22 RESET...23 SOFTWARE...23 SAFETY DEVICES...24 Safety edge system X2 / X Typ 1: Safety device with external evaluator for 1 K2 resistance...24 Typ 2: Resistance evaluation 8K2 with normally open safety edge contact...24 Typ 3: Optical safety edge (Vitector)...24 Page 2

3 Page Pass door X Emergency stop X Function of the safety edge system X FUNCTION DESCRIPTION...27 Internal push button / Three push button / Key switch X5 / X Automatic closing...27 Automatic closing interruption...27 Photo-beam for Closing Direction X6 / X Ceiling pull switch / Radio control X7 / X Key switch (latching) interrupt automatic closing X Light indicator for traffic control X Potential free changeover contact X20 / X AIR look SLF...33 Status monitoring function SMF...33 Maintenance cycle counter...33 Software Update...34 Short circuit / overload monitor...34 OPERATING STATUS DISPLAY...35 TECHNICAL DATA...39 LIFETIME / DOORCYKLES...40 DECLARATION OF INCORPORATION...41 FUNCTION OVERVIEW...42 Page 3

4 SAFETY DIRECTIONS Basic Directions This control has been built in accordance with EN Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements and EN Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods; and left the factory in perfect condition from the point of view of safety. To maintain this condition and to ensure safe operation, the user must observe all the directions and warnings contained in these operating instructions. In principle, only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. Reconstruction of or changes to TS 981 FT are only permissible with the approval of the manufacturer. Original replacement parts and accessories authorised by the manufacturer guarantee safety. Liability ceases to apply if other parts are used. The operational safety of an TS 981 FT is only guaranteed if it is used in accordance with the regulations. The limiting values stated in the technical data should not be exceeded under any circumstances (see corresponding sections of the operating instructions). Safety Regulations During the installation, initial operation, maintenance and testing of the Control Panel, it is necessary to observe the safety and accident-prevention regulations valid for the specific application. In particular, you should observe the following regulations (this list is not exhaustive): European normative - EN Safety in use of power operated doors - Test methods - EN Safety in use of power operated doors - Requirements - EN Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods Please check normative s bellow. VDE-regulations - EN 418 Safety machinery Emergency stop equipment functional aspects Principles for design - EN / VDE Safety of machinery - Electrical equipment of machines - Part 1: Prescriptions générales - EN / VDE Safety of household and similar electrical appliances - Part 1: General requirements Regulations - Please ensure that the local regulations relating to the Safety of Operations of Doors are followed Page 4

5 SAFETY DIRECTIONS Explanation of warnings These operating instructions contain directions which are important for using the ELEKTRO- MATEN appropriately and safely. The individual directions have the following meaning: DANGER This indicates danger to the life and health of the user if the appropriate precautions are not taken. CAUTION This warns that the ELEKTROMATEN or other materials may be damaged if the appropriate precautions are not taken. General warnings and safety precautions The following warnings are to be understood as a general guideline for working with the ELEKTROMATEN in conjunction with other devices. These directions must be observed strictly during installation and operation. Check that all screw connections are secure before operating the control and adjusting the limit switches. Please observe the safety and accident prevention regulations valid for the specific application. The ELEKTROMATEN must be installed with the authorised coverings and protective devices. Care should be taken that any seals are fitted correctly and screw couplings are tightened correctly. In the case of ELEKTROMATEN with a permanent mains connection, an all-pole main switch with appropriate back-up fuse must be provided. Check live cables and conductors regularly for insulation faults or breakages. When a fault is detected in the cabling, the defective cabling should be replaced after immediately switching off the mains supply. Before starting operation, check whether the permissible mains voltage range of the devices corresponds to the local mains voltage. With three phase motor connection it must have right phase rotation Page 5

6 INSTALLATION ADVICE After the ELEKTROMATEN is fitted we recommend the following procedure to rapidly reach a fully functioning door. Installation Enclosure installation page 8 Installation Wiring the Drive to the Control page 8 Check Mains supply page 9 Check Phase rotation page 10 Programming Rapid limit adjustment page 11 The door is ready to work in Dead man mode. Installation Safety devices page 14, 24 Programming Door functions page 16 The door is ready to work in automatic mode. Check connection of external devices e.g. push button etc. Overview to connect external devices see diagram (page 14-15). After the devices are connected the programming of the control panel must be finalised (page 16). Page 6

7 INSTALLATION OVERVIEW Important! Using the connection cable out side the building is not permitted. Connection cable ELEKTROMAT for Motor and DES ( electronic limit) 11 Spiral cable for Safety edge system 4 Mains supply 5 Photo-beam 5 Pull switch 3 Three push button 5 Key switch (latching) interrupt automatic closing Emergency stop Red / Green Traffic- Light 3 3 2x4 ( ) Number of cores in the cable Page 7

8 ENCLOSURE INSTALLATION Before mounting the enclosure, the surface has to be checked for flatness, slope and freedom from vibrations. Mounting must be vertical. It is important that the door can be clearly seen from the position of the control through-out its travel. CONNECTING THE CONTROL AND THE ELEKTROMATEN After the drive and control are fitted they can be connected with a plug-in cable. The cable has plugs on each end and for easy fitting. The plugs for motor and control panel are different and cannot be interchanged. Control panel TS 981 FT ELEKTROMAT Motorconnection (MOT) PE Connection cable for digital limit (DES) 1 2 PE 3 4 Motor plug-in PIN PIN Cable identification Motor plug to control unit PIN - Wire-No. Excution: 1-3 Phase W 2-2 Phase V 3-1 Phase U 4-4 Neutral (N) (not used) 5 - PE Earth Limit plug-in to control panel TS 981 FT (DES) PIN - Wire-No. Excution: 1-5 Safety chain 24V DC 2-6 RS485 B 3-7 GND 4-8 RS485 A 5-9 Safety chain V DC Page 8

9 MAINS SUPPLY DANGER! To the life and health thru electric shock. Before mounting the mains supply must be switched OFF. External fuse! Control must be saved against short circuit and overload by an external fuse, max. 10A delayed, in the mains supply. An automatic cut off switch is required, regarding the supply for three-phase or single-phase. When connecting control to mains supply a mains isolator switch or (16A CEE plug) according EN is required. The control panel has an integrated auto controlled power unit for voltages from 230V up to 400V +/- 10%. The supply disconnect device (Main switch or CEE plug) must be installed between 0,6m and 1,7m above floor level. The Control panel TS 981 FT has a universal electric supply and works with the following supplies. (See diagram Fig.1-5) Mains supply terminal Fig.: 1 Fig.: 4 Fig.: 2 Fig.: 5 symmetric winding Fig.: 3 asymmetric winding FU 0,85KW =1x230V/N/PE or 3x400V/N/PE Page 9

10 MOTOR CONNECTION (internal wiring) Three-phase 3 x 400 V AC, N, PE Star connection Three-phase 3 x 230 V AC, PE Delta connection brown blue supply for brake rectifier Important note! For 3x400V AC PE no neutral, the brake rectifier must be connected between terminal V and starpoint terminal. brown blue supply for brake rectifier Single-phase 1x 230 V AC, N, PE symmetrical winding Single-phase 1x 230 V AC, N, PE asymmetrical winding On several ELEKTROMATEN the connection U1 und V1 on the motor-plug are interchanged. PHASE ROTATION Important Notice! After the mains supply has been connected: to confirm that the phase rotation of the electrical motor is correct the door shall move OPEN if the OPEN push button is operated. If the door does not OPEN change first phase rotation. For all three phase ELEKTROMATEN : Change wiring at terminal X1: For inverter drives FI-ELEKTROMATEN see page 11. For all single phase ELEKTROMATEN :Change wiring at the connection cable plug, change core no. 1+3 reciprocal. DANGER! To the life and health through electric shock. Before changing phase rotation the mains supply must be switched OFF. Page 10

11 RAPID ADJUSTMENT OF THE LIMITS When the phase rotation has been checked the Rapid limit adjustment can be made. The final setting can be made with the fine adjustment (Control Programming page 17). Safety limits and pre-limits are automatically adjusted. 1. Setting final limit open Door open press button to reach open limit Display blinking 1a. Reversing FI-ELEKTROMAT rotation 2. Memorise the final limit open Reversing reverse the motor rotation keep both buttons pressed for three seconds until the display changes Display blinking Display changes stop-button for 3 sec. until the display changes Display changes The final limit OPEN is memorised when the door moves for at least one second from close into the open limit position. 3.Setting the final limit close Door close press button to reach close limit Display blinking 4. Memorise the final limit close stop-button for 3 sec. until the display changes Display changes The Rapid adjustment is finished The door could be moved in DEADMAN mode OPEN /CLOSE Further adjustments see programming mode Page 11

12 HARDWARE OVERVIEW MOT DES MMC/SD MOT DES MMC / SD TS 981 FT SLF SLF X1 V1 SMF X F1 = 1,6A t SMF S1 X V GND V GND X11 X V GND V 12V GND X3 X5 X6 X7 X13 X15 X16 X17 X18 Page 12

13 HARDWARE OVERVIEW Description Print: X1 Mains supply external supply 230V 1.9 = L1 L1 fused with F1 = 1,6A 1.8 = N (only with 3 x 400V, N, PE und 1 x 230V, N, PE symmetric winding) X2 Safety edge system and pass-door plug only open function (input for photo-beam etc.) X3 Emergency push button X11 Key switch ON / OFF for automatic closing X13 Traffic lights 2x Red / Green X18 Safety edge input for two door leafs X20 Potential free relay contact 1 X21 Potential free relay contact 2 DES Limit connection MOT Motor connection MMC/SD Slot for memory cards SLF Slot for Air-lock control function SMF Slot for Status / Information function S1 Selector switch V1 7-segment display Internal push button Command from inside Command from outside X5 Three push button / Key switch X6 Reflective photo-beam / photo-beam X7 Ceiling pull switch / Radio control X15 Three push button / Key switch X16 Reflective photo-beam / photo-beam X17 Ceiling pull switch / Radio control Page 13

14 WIRING DIAGRAM N L1 L1 fused via F1 = 1,6At Pass-door contact Emergency stop button inside Safety edge for open direction Typ1: safety device with external evaluator for 1K2 resistance Typ 2: electrical safety edge with 8K2 brown green Typ 3: optical safety edge system white Transmitter Receiver Safety edge for closing direction or or br wh gr 1 gr 2 Safety device with external evaluator for 1K2 Electrical safety edge 8K2 Transmitter - Receiver br br gr 1 gr 1 wh wh Receiver - Transmitter br gr 2 wh br gr 2 wh Optical safety edge (left and right leaf) Page 14

15 WIRING DIAGRAM outside inside or or OPEN STOP CLOSE Three push button station inside or outside OPEN/ CLOSE STOP Key switch with stop button inside or outside OPEN/ CLOSE Key switch inside or outside outside or inside Reflective photo-beam inside or outside for closing direction Transmitter- Receiver photo-beam inside or outside Ceiling pull switch / Radio control inside or outside Key switch ON / OFF automatic closing N L external or X1 1.8/ Red - Green light outside Red - Green light inside Potential free relay contact Potential free relay contact Page 15

16 CONTROL PROGRAMMING 1. Enter programming Mode switch for 3 sec. until display = Chose program and confirm and Turn 3. Adjustment Functionen Door position or Turn foil buttons 4. Memorise Functions Door position or stop-button further adjustments 5. Exit programming and Turn until display = 00 Page 16

17 CONTROL PROGRAMMING 2. Choose program and confirm Operating mode Door function Door position Final limit open coarse adjustment Final limit close coarse adjustment Final limit open fine adjustment Final limit close fine adjustment Pre-limit safety edge fine adjustment Switching position Relay 1 Switching position Relay 2 3. Adjustment Dead man OPEN Dead man CLOSE Self-hold OPEN Self-hold CLOSE Self - hold OPEN, CLOSE (X5/X15) release for external pushbutton function only dead man close Move door to open or close direction Move door to open or close direction Final limit open can be changed without door movement using +/- Final limit close can be changed without door movement using +/- Pre-limit safety edge can be changed without door movement using +/- Move to switching position relay 1 Move to switching position relay 2 4. Memorise stop Button stop Button stop Button stop Button Page 17

18 CONTROL PROGRAMMING 2. Choose program and confirm Functions Safety edge function in Pre - limit area 3. Adjustment Safety edge is activated Safety edge is deactivated 4. Memorise Automatic closing feature Automatic closing after photo-beam is interrupted and re-made Step by Step function (X7 / X17): only Ceiling pull switch / Radio remote control time can be set between sec. 0 = OFF OFF ON Vehicle recognition, closes when the contact is more than 1,5 sec. triggered X7 / X17 = Command 1 X7 = Command 1, X17 = Command 2 ATTENTION!.2 and.3 not applicable with traffic light function and inerlocking function. Programming item 6.1 to.0 Programming item 7.1 to.0 X7 = Command 2, X17 = Command 1 X7 / X17 = Command 2 X7 / X17 = Command 3 Function Relay 1 OFF Switch contact impulse: 1sec. only available with menu 1.7 Switch contact continuous only available with menu 1.7 Switch contact impulse: 1sec. by open - commands Page 18

19 CONTROL PROGRAMMING 2. Chose program and confirm 3. Adjustment 4. Memorise Functions Function Relay 2 Safety functions OFF Switch contact impulse: 1sec. only available with menu 1.8 Switch contact continuous only available with menu 1.8 Switch contact impulse: 1sec. by open - commands Door overload monitor OFF Not useable with Folding Doors Page 19

20 CONTROL PROGRAMMING 2. Choose program and confirm 3. Adjustment 4. Memorise Settings only for ELEKTROMATEN frequency inverter FI OPENING speed CLOSING speed HIGHER CLOSING speed Not useable with Folding Doors Changeover position CLOSING speed OPEN acceleration Output speed rpm Output speed rpm Increased output speed down to door height of 2.5 m 0 = OFF Changeover position higher/lower speed Setting in 0.1 s steps stop Button CLOSE acceleration OPEN deceleration CLOSE deceleration Setting in 0.1 s steps Setting in 0.1 s steps Setting in 0.1 s steps The appeared numbers for output speed OPEN and CLOSE corresponding to the real RPM of the drive unit. The speed has a direct influence into operating forces of the door. The maximum and minimum speed will be delivered by the drive unit in use and can not be raised or reduced. Check again the adjustment and drive unit s speed. Page 20

21 CONTROL PROGRAMMING 2. Choose program and confirm Extended door functions Traffic light management selection Attention! Programming item and.3 not applicable 3. Adjustment OFF One-way traffic Two-way traffic - priority OFF Two-way traffic - priority inside 4. Memorise Two-way traffic - priority outside Extended green light period Fore-warning period Gateway evacuation period Red light function if the door is CLOSED Adjustment 0-90 seconds Adjustment 0-10 second Adjustment 0-90 seconds Red lights OFF Red light inside ON Red light outside ON Red light inside/outside ON Air-lock function Attention! Programming item and.3 not applicable Door OPEN command transmission if the Air-lock function is ON Status message function SMF ON / OFF OFF ON Time adjustment between 0 10 seconds. Delayed opening door 2 starts if door 1 is closed SMF OFF SMF for message module SMF for unidirectional RS 232 interface module Page 21

22 CONTROL PROGRAMMING 2. Chose program and confirm 3. Adjustment 4. Memorise Maintenance cycle counter Counter adjustment Reaction when reaching correspond from up to Count down cycles Display appears CS and adjusted number of cycles Changing to DEADMAN display appears CS and adjusted number of cycles Changing to DEADMAN same as 0.2 reset to about 500 cycles possible, press 3 sec. Stop Button Display appears CS and adjusted number of cycles and Relay contact is activated MEMORY CHECK 2. Chose program and confirm Displayed Info Cycle counter 7- digit Info last 2 faults Info Program changes 7- digit Info Program version M HT ZT T H Z E The cycles would be displayed as follow. M = H = 100 HT = Z = 10 ZT = E = 1 T = Last 2 faults would be alternately displayed. M HT ZT T H Z E The Number of program changes would be displayed as follow. M = H = 100 HT = Z = 10 ZT = E = 1 T = Program version will be displayed Page 22

23 RESET 2. Chose program and confirm RESET except cycleand Program change counter 3. Adjustment Reset 4. Memorise stop button 3 sec. SOFTWARE 2. Chose program and confirm Software loading 3. Adjustment Select required software version from S-D card 4. Loading stop button 3 sec. 2. Chose program and confirm Software saving Page 23

24 SAFETY DEVICES Safety edge system X2 / X18 The control panel TS 981 FT recognises and works with 3 different safety edges, and monitors automatically these systems in OPEN and CLOSE direction. The safety edge for CLOSING direction can be connected at X18 with one of these for each door leaf. At terminal X2 an additional system can be connected to monitor OPEN direction. Typ 1: Safety device with external evaluator for 1 K2 resistance This external evaluator must have an NC output contact available, and a 1 k2 resistance is required to recognise eventually failures in the connection line between output contact and control panel input. Typ 2: Resistance evaluation 8K2 with normally open safety edge contact This evaluation system is made for electrical safety edges within an end-of-line resistor of 8K2 +/- 5% 0,25W. The resistor must be connected parallel with the switch in the safety edge. Typ 3: Optical safety edge (Vitector) The principle of operation is as a one way light barrier. By activating the safety edge, the photobeam will be interrupted. Important note! The terminal input X18.1 and X 18.2 for closing direction must be connected always with 2 of the similar safety edge systems. Important note! When using a safety edge system for closing the automatic pre-limit adjustment (5 cm) must be checked. When the safety edge is activated the door should stop and reverse to the open position. Important note! When connecting a safety edge, take account of EN for Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods. Page 24

25 SAFETY DEVICES Pass door / input X2 The pass door switch Entrysense features a protective function complying with safety category 2 under EN The electrical contact is monitored by the control panel that outputs fault F1.7 when it malfunctions. The electronic pass door switch Entrysense: function and test The pass door switch Entrysense is fitted with two reed contacts that are switched by a permanent magnet. The control panel evaluates the switching states and the contact resistance independently of each other. At the lower limit position F1.2 is displayed when an OPEN command is given and at the same time the pass door / open. The door can be moved only after the pass door has closed or when the pass door / signal is OK. If the circuit will be opened when the door is moving the door is stopped immediately. F1.7 is displayed when an OPEN command is given after the door controller has detected beforehand asymmetrical pass door switch positions (see below for reasons). This fault can be reset when the door is reopened. This ensures that contact misalignments caused by vibrations from the moving door do not trigger door shutdown. Possible reasons for fault F1.7 Decription Door was not fully closed for longer than 2 s so that only one reed contact was switched during this time. The control voltage was less than 21,6V for longer than 2 s (by 10%). Contact resistances too high in the pass door. Electronic pass door switch is not installed correctly: distance between switch and magnet too large switch and magnet not attached at the same height switch installed at wrong position Measures to solve the problem Reopen and close the door. Measure the control voltage at the terminals 24V-GND. After troubleshooting reopen and close the door. With the pass door closed: Measure resistance and if necessary replace the contact resistances in the pass door. Check that the door pass door switch is installed correctly. After troubleshooting reopen and close the door. Page 25

26 SAFETY DEVICES Emergency stop X3 These terminals are to connect an emergency stop button according to DIN EN 418. Alternatively the terminals can be used to connect a safety device against entrapment (e.g. self-testing light barrier). Function of the safety edge system X18 With Menu 2.1 the function of the safety edge system (close direction) can be chosen. Function Active safety edge De-activated safety edge Reaction following the activation stop no reaction, door moves until final limit close Important note! When the safety edge has been operated twice the automatic closing feature will be interrupted and fault F2.2 will be displayed. To reset the fault press the internal push button so that the door close until the final limit is reached. Page 26

27 FUNCTION DESCRIPTION Internal push button / Three push button / Key switch X5 / X15 Internal and external push button Internal and external push button working seperately from each other. Pushing at the same time, the internal push button has priority. Important note! Dead man mode OPEN and CLOSE with internal push button. Dead man mode CLOSE with external push button. (Menu 0.1 Adjustment.4) In Dead man mode the user shall be in full view of the door throughout its travel. Automatic closing Menu 2.3 the timer works between sec. If the automatic closing is actived, the door will close, from each limit position after the pre-adjusted time. Important note! The timer can be interrupted by pressing the internal pushbutton stop when the door has reached a limit position. With a new command the timer is re-set. Automatic closing interruption Menu 2.4 can be used if the timer operation is required after interrupting and re-making the photo-beam. The door closes after 3 seconds. Page 27

28 FUNCTION DESCRIPTION Photo-beam for Closing Direction X6 / X16 Control works with reflexive and through photo-beams connected on terminal X6 / X16. A 24V DC supply for the photo-beam is available. The light barrier is used in a normally closed operating mode. In case the light barrier is activated or it malfunctions the contact will open and cause following reactions. Door Position Door closed Door opening End position open without timer active End position open with timer active End position open with timer active and time interruption Closing Door Reaction when Photo-beam is Interrupted no reaction no reaction no reaction resets open timer for automatic closing mode With the photo-beam connected the door closes after 3 sec. when the beam has been interrupted and remade The time delay is cancelled and re made. Stops and re-opens fully These terminals could also be used to connect other devices e. g. radar, etc. Important! At connection to 24V DC consumes of external devices shall not exceed 1000 ma. Page 28

29 FUNCTION DESCRIPTION Ceiling pull switch / Radio control X7 / X17 It is possible to connect a ceiling pull switch or a radio receiver. The radio receiver's switching contact must be potential free. Menu 2.6: Several types of commands can be adjusted. With each command (impulse) the door operates in the following sequences. With each command (contact) the door operates in the following sequence: Command 1: Without stop Door position Door closed Door moving open Door open Door moving close Door operation Door travels to fully OPEN-position No reaction Shutter moves to fully closed position Shutter will STOP and moves BACK to final open Position Command 2: With stop Door position Door closed Door moving open Door open Door somewhere in between position Door moving close Door operation Door moves to fully open or intermediate position Door closed Door moves to fully closed position Door moves in opposite direction Door closed Command 3: Open With each impulse the door travels to the final open position Page 29

30 FUNCTION DESCRIPTION Key switch (latching) interrupt automatic closing X11 The automatic closing time can be interrupted with a normally open switch (latching) Light indicator for traffic control X13 TS 981 FT control have a complete one-way and two-way traffic light management integrated. Two pairs of red/green light indicators may be connected on terminal X13. Supply voltage for these light indicators is selectable and could be provided from external or directly from internal terminals X1 1.8 / 1.9. A neutral is always required. Attention! Light indicators with 230V LED-bulbs are recommended. They have a big luminosity, low requirement of energy, and they are maintenance free. If conventional bulbs in use the maximum power for each indicator light shall not exceed 40W. Page 30

31 FUNCTION DESCRIPTION Menu 6.1 Traffic light management The integrated traffic light management of TS 981 FT supplies two traffic modes One-Way Two-Way One-Way mode: This could be selected if the door width delivers enough space for two cars driving through the door. The lights indicating only when the door is fully OPEN. Additionally the lights supplying fore - warning signal when the door travels downwards. Two-way mode: This could be selected if the door gateway does not deliver enough space for two cars and sequence must be controlled. Priority for inside or outside could be adjusted. Menu 6.2 Extended green light period Timer could be selected from 3 seconds up to 90 seconds. This works only if the door is OPEN and the green light is illuminated. Timer counts down after a CLOSE command or if two-way traffic mode is selected, and a command from opposite side is given. The indicator keeps green light during the whole time. This function could be used for green light activation only, and without automatic closing function. Menu 6.3 Fore warning period Fore - warning supplies an additional signal before the door closes; red lights flushing hereby with a frequency of 1 Hz. Selectable time is 10 seconds and the function starts when green light period has finished. Menu 6.4 Doorway evacuation period The selected mode supplies the possibility to keep the gateway free from present car, before a new car drives into the doorway. Timer counts down if green period has finished, respectively after adjuster pre-warning time; during this time the red light is indicated. Menu 6.7 Red light function if door closed On requirement continuous red light function ON or OFF may be selected. Attention: Traffic light management works independent of automatic closing or continuously Open command. Page 31

32 FUNCTION DESCRIPTION Potential free changeover contact X20 / X21 In Menu 2.7 / 2.8 this contact is able to work for several functions. Important note! It is only possible to work with one adjusted function. When activating the switching point the door must be moved to the point. Menu 1.7 / 1.8 must be activated. AIR look SLF Air-lock management could be realised by means an easy electrical cable connection between two doors with TS 981 FT. The required module with cable should be connected into SLF plug-in. This module would be delivered complete within a manual. When cable connection is finalized select AIR-LOCK ON in Menu 7.1 in both control panels. Automatic OPEN - Transmission To realise Air-lock operation a push button is not required. An automatic open impulse about timer adjustment could be selected in Menu 7.2, thereafter the present closed door OPENS when acting door has CLOSED. Page 32

33 FUNCTION DESCRIPTION Status monitoring function SMF When in use a port supplies status or error information s to a central monitoring unit. To realise a lot of different uses the control has a socket to be used with external modules that supplies relay contacts or BUS-gateway. Users manual would be delivered with the module. Maintenance cycle counter Free adjustable maintenance cycle counter Menu 8.5 makes it possible to pre-adjust a max. No of cycles until a maintenance is agreed. The no of cycles can be adjusted from up to ; the adjustment is possible in steps of cycles. Three different reactions can be chosen if the point of pre- adjusted maintenance cycles has been reached, see Menu 8.6 Whenever the final open limit has been contacted the pre-adjusted number will be reduced with 1 until 0 is reached. When maintenance was done the cycle counter could be re-adjusted to a new maintenance period and count down starts again. Page 33

34 FUNCTION DESCRIPTION Software Update For software updates TS 981 FT have a MMC/SD card slot available. With this function the software can be updated respectively in external places saved. For that purpose the new program can be taken from a PC with special card reader function for GFA cards, following the card could be guided into the control panel existing slot. Attention! Before loading the new program check the existing program is saved. Menu 9.7 MMC/SD card program can be uploaded. If this function is selected the display appears 0. When pushing the integrated open and close button the display appears all existing software versions on MMC/SD card. To start the uploading mode the stop-button shall be pushed for three seconds. As long the loading has not started the mode may be interrupted if pushing the switch. With Menu 9.8 present up to date programs could be saved onto MMC/SD card. Down load initialising: Insert MMC/CD card, select menu 9.8 and push switch. Short circuit / overload monitor The TS 981 FT control panel delivers 2 supplies for external devices. 230V AC; max. 1,6 A 24V DC; max. 1000mA At a short circuit or overload at the 24V DC supply, the display is off. Page 34

35 OPERATING STATUS DISPLAY The control TS981 FT can display up to three different status conditions one after another. Each status is displayed with a letter and a number. The letter and the number are flashing alternately, thereby the control differentiates between a FAULT = F and a command = E. Report Description Measure to solve the problem Pass door contact open X 2.1- X 2.2 Check the proper operation of pass door contact, or whether the supply cable is broken Emergency operator or motor-winding thermal protection operated Emergency stop activated Error AIR-LOCK function Check emergency operator or whether the drive unit is overloaded. Check the emergency stop is activated, or whether the supply cable is broken Check, whether opposite control panel is ON and Air-lock function is adjusted or possibly the cable connection is interrupted Failure pass door contact X 2.1- X 2.2 or control voltage circuit less than 24V Check pass door circuit s transition resistance and weather pass door switch works; verify the voltage is OK at 24V terminal to GND Failure input pass door X 2.1- X 2.2 For reset switch control panel OFF-ON Safety edge X18 not recognised Check the safety edge is connected correctly or the wrong type has been selected in the program Light barrier activated Check the light barrier has been fitted properly, or whether the connecting cable is broken Safety edge operated in two consecutive cycles Safety edge X18 8K2 activated Check if there is an obstacle in the door area, or the connecting cable is broken or there is a short circuit in the cable Check the safety edge is activated or there is a short circuit in the connecting cable Page 35

36 OPERATING STATUS DISPLAY Report Description Measure to solve the problem Safety edge X18 8k2 defect Check safety edge and connecting cable is not broken Safety edge X18 1K2 activated Check safety edge and connecting cable is not broken Safety edge X18 1k2 defect Check safety edge and connecting cable do not have a short circuit Optical safety edge X18 activated or defect Check the proper safety edge function or whether the supply cable is interrupted Limits not adjusted Adjust limits Safety open limit operated Turn mains supply OFF and move the door open - with the manual operator- until the safety limit is free or the open limit should be re-adjusted. Safety close limit operated Turn mains supply OFF and move the door close - with the manual operator- until the safety limit is free or the close limit should be re-adjusted. Safety edge X2 not recognised Door load monitor has activated Check the safety edge is connected correctly or the wrong type has been selected in the program Not useable with Folding Doors. Adjust Menü 3.1 to.0 (OFF) Safety edge X2 8K2 activated Check the safety edge is activated or there is a short circuit in the connecting cable Safety edge X2 8k2 defect Check safety edge and connecting cable is not broken Safety edge X2 1K2 activated Check safety edge and connecting cable is not broken Safety edge X2 1k2 defect Check safety edge and connecting cable do not have a short circuit Optical safety edge X2 activated or defect Check the proper safety edge function or whether the supply cable is interrupted Page 36

37 OPERATING STATUS DISPLAY Report Description Measure to solve the problem ROM - Fault Internal fault report RAM - Fault Internal control fault DES no response Drive unit does not work Phase rotation failure Fault acknowledgement: open and close the pass door switch or switch OFF and ON the main switch or disconnect and reconnect the mains plug. Fault acknowledgement: open and close the pass door switch or switch OFF and ON the main switch or disconnect and reconnect the mains plug. Fault acknowledgement: open and close the pass door switch or switch OFF and ON the main switch or disconnect and reconnect the mains plug. Fault acknowledgement: open and close the pass door switch or switch OFF and ON the main switch or disconnect and reconnect the mains plug. Check electronic limit DES connection. To acknowledge the fault switch off and on the main switch or disconnect and reconnect the mains plug. If necessary replace the control panel or digital limit DES). Check the door mechanics. Check the limit shaft for function (turning) Check phase rotation. Check main supply phase rotation turns right Inadmissible door movement when stopped, e.g. owing to worn brake or by a failure delivered from the inverter. The drive does not follow the given command e.g. torque overload or a failure at the frequency inverter. Fault acknowledgement: with next command being given. Check function of the brake and replace if necessary. If the brake works correct and if the fault reappears replace the frequency inverter. Fault acknowledgement: with next command being given. Check drives load and mains voltage. If this is correct and if the fault reappears replace the frequency inverter. Closing rpm over speeded at FI Internal FI communication fault at FI. Insufficient mains supply or by a fault delivered from FI. Fault acknowledgement: switch OFF/ON on the mains or disconnect and reconnect the mains plug and if the fault reappears replace the frequency inverter. Fault acknowledgement: switch OFF/ON on the mains or disconnect and reconnect the mains plug and if the fault reappears replace the frequency inverter. Fault acknowledgement: with next command being given. Braking time must be increased, see menu. Intermediate circuit overload, e.g. braking time too short Fault acknowledgement: with next command being given. Braking time must be increased, see menu. Exceeding of the admissible Fault acknowledgement: with next command being temperature of the FI e.g. delivered by exceeded no cycles, heat given. accumulation, heat transmission etc. Exceeded motor current by overload of the drive unit or failure at the frequency inverter. Check the door mechanism and weight. Fault acknowledgement: with next command being given and if the fault reappears replace the frequency inverter. FI Group status Fault acknowledgement: with next command being given and if the fault reappears replace the frequency inverter. Page 37

38 OPERATING STATUS DISPLAY Report Command description open command being given stop command being given close command being given adjusted cycles for maintenance reached Display off = short circuit or overload at the 24V DC supply Report Status opening flashing flashing closing door stopped between the adjusted limits door stopped at open limit door stopped at close limit Page 38

39 TECHNICAL DATA Housing Dimensions 190mm x 300mm x 115mm (W x H x D) Mounting vertical ELEKTROMATEN Supply Three-phase 3 x 230 / 400V AC ± 5%, Hz Single-phase 1 x 230V ± 5%, Hz Power max. at 3 x 400V AC, max. 3kW Control supply via L1,L2 400V AC or 230V AC %, Hz, voltage changing with bridge to 3- pole terminal, safety fuse F1 (1,6A t) External supply fuse 10A delayed Permitted Load ca. 40 VA (without motor and ext. 230V) External supply 1 230V via L1 and N, safety fuse F1 (1,6A t) External supply 2 24V DC uncontrolled, max. Load 150mA, Protected via electronic fase Inputs 24V DC / typ. 10mA signal length must be more than 100ms Relay output If inductive loads are to be switched (e.g. other relays) those have to be protected with free-wheeling Diodes contact load at 230V max. 1A Traffic light contacts Temperature Humidity: Vibration: Protection class LED - bulb 230V or Normal bulb 230V shock resistant max. 40W Working: C Storage: C To 93% not condensing Vibration free mounting, e.g. on flat built wall IP54 (CEE Plug), IP65 available Page 39

40 LIFETIME / DOORCYKLES The GfA control panels working with electro mechanical contactor boards. Contactor boards having generally a limited life time; this depends on the switched power of ELEKTROMATEN in use and the amount of switching cycles. Therefore we recommend a replacement for control boards in use after doors having reached their confirmed lifetime cycles. Coherence between power and amount of cycles for ELEKTROMATEN describes diagram bellow. Torzyklen Cycles according nach to DIN EN ~ 230/400V, 50Hz ~230V, 50Hz ,25 0,50 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 Leistung in kw Power in KW Page 40

41 DECLARATION OF INCORPORATION in the terms of Machinery Directive 2006/42/EC for partly completed machinery, Appendix II Part B Declaration of conformance in terms of EMC Directive 2004/108/EC GfA-Gesellschaft für Antriebstechnik Dr.-Ing. Hammann GmbH & Co. KG Wiesenstraße Düsseldorf Telefon: +49 (0) Telefax: +49 (0) We, the GfA - Gesellschaft für Antriebstechnik Wiesenstr. 81, Duesseldorf (Heerdt), Germany hereby declare that the following products are conform with the above EC Guidelines and are only intended for installation in door equipment. Standards applied Door control panel TS 981FT DIN EN Doors - safety in use of power operated doors DIN EN Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods DIN EN Safety of household and similar electrical appliances Purposes - Part 1 : General requirements DIN EN Electromagnetic compatibility (EMC) Part 6-2 Generic standard Emission standard for industrial environments DIN EN Electromagnetic compatibility (EMC) Part 6-3 Generic standard Emission standard for residential, commercial and light-industrial environments We undertake to transmit in response to a reasoned request by the appropriate regulatory authorities the special documents on the partly completed machinery. Authorised representative for the compilation of the relevant technical documents (internal EU address) Dipl.-Ing. Bernd Synowsky Documentation representative Incomplete machines within the meaning of the EC Directive 2006/42/EC shall only be intended to be integrated into other machines (or into other incomplete machines/systems) or to be assembled with them to form a complete machine within the sense of the Directive. Therefore, this product cannot be commissioned before it is determined that the entire machine/system to which it was integrated shall comply with the provisions of the Machinery Directive indicated above. Düsseldorf, Stephan Kleine CEO Signature Erstelldatum: Zeichnungs-Nr.: Revisionsstand: b Page 41

42 FUNCTION OVERVIEW Control panel for ELEKTROMATEN up to. 3 kw at 400V / 3~ with electronic limit DES designed for only low-level adjustment 7- Segment led display showing - Programming the control panel - Displays Command - / Info- / Fault Software release loading and saving Mains supply - 400V / 3~ with and without Neutral - 230V / 3~ - 230V / 1~ (for single-phase motors) Door operating modes - Dead-man open- and close - Self-hold open- and dead-man mode close (without safety edge) - Automatic open- and close (with safety edge connected) Integrated safety edge systems - 8K2 normally open contact - 1K2 normally close contact - Optical safety edge system (System Vitector) automatic close feature - Free programmable from 1 up to max. 240 Sec. - On interrupting and re-making light barrier closing after 3 sec.. - Can be interrupted by a separate switch supply for external devices - 230V (at 400V / 3~ with N), up to 1,6A load - 24V DC, up to 1000mA load Plug for 5 pole motor connector 6 pole for electronic limit DES Plug for spiral cable (safety edge and pass-door contact) integrated internal pushbutton OPEN / STOP / CLOSE Additional terminals for different control equipment - Emergency stop ( LATCHING) - Additional safety stops - External three push button OPEN / STOP / CLOSE - Light barrier activated Stop and Reverse function, time reset, time interruption 3 sec. - One channel - impulse functions e. g. Ceiling pull switch for OPEN / CLOSE / STOP sequencing or radio control - 2x potential free relay output (NC / NO), output signal from aux. limit If a signal lamp is in use, the potential free limit is not available Integrated traffic light management - One-way - Two-way Page 42

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Door control panel TS 958 Software 1.0 - (Design and functions subject to change) 51171324 - c 03.2007 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION

More information

Electrical Operating Instructions

Electrical Operating Instructions Electrical Operating Instructions Door Control Panel TS 958 Software 1.2 - (Design and functions subject to change) 51171324 - f 01.2010 Northern Sales & Distribution Centre The Door Centre, Discovery

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Door control panel TS 961 Software 2.6 (Design and functions subject to change) 51171292 - f 02.2013 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION

More information

Electrical Operating Instructions

Electrical Operating Instructions Electrical Operating Instructions Door Control Panel TS 970 Software 4.5 - (Design and functions subject to change) 51171271 - i 01.2012 Northern Sales & Distribution Centre The Door Centre, Discovery

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Door control panel TS 981 Software 2.6 (Design and functions subject to change) 0000000 0000 51171314 XXXXX 51171314 - q 07.2015 OPERATING INSTRUCTIONS Page SAFETY

More information

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Door Control Panel TS 960. instructions. (Design and functions subject to change) / Electrical operating Operating instructions Door Control Panel TS 960 GB (Design and functions subject to change) 51171098 / 10.2002 OPERATING INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 FUNCTION OVERVIEW...6

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009 OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical

More information

Operating instructions

Operating instructions en Operating instructions Safety brake Size 4 51172121 - b 072010 OPERATING INSTRUCTIONS 52210087 List of Contents Page SAFETY DIRECTIONS 3 DESIGN AND FUNCTION4 MAINTENANCE AND EXAMINATION 4 SERVICE /

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions ELEKTROMATEN without reversing contactor with / without terminal box with / without magnetic brake 51171321 - c 03.2010 OPERATING INSTRUCTIONS 52210079 consisting

More information

Operating instructions

Operating instructions Pos: 1.1 /BA_Module/BA_AA Deckblatt/BAAA000001_M001 @ 0\mod_1190623555800_6.doc @ 448 Pos: 1.2 /BA_Module/BA_Seitenumbruch @ 0\mod_1190719383361_0.doc @ 548 en Operating instructions Safety brake FG 220-60

More information

Mechanical Operating Instructions

Mechanical Operating Instructions Mechanical Operating Instructions SE 5.24 WS / SE 5.24 51172095 / 04.2006 Bau muster Zertifizierung geprüft EN 13241-1 OPERATING INSTRUCTIONS 52210111 consisting of: M : Mechanical Operating Instructions

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Mechanical operating instructions

Mechanical operating instructions en Mechanical operating instructions Safedrive - ELEKTROMATEN SI / SIK 51172028 - i 09.2011 OPERATING INSTRUCTIONS 52210113 consisting of: M : Mechanical operating instructions E : Electrical operating

More information

Installation Instructions

Installation Instructions Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom

More information

Installation instructions

Installation instructions aus Installation instructions Door Control TS 970 51171635 b 11.2013 0000000 0000 511711635 XXXXX 2 GfA-ELEKTROMATEN Australia Pty Ltd P.O. Box 267 Roseville 2069 NSW Telephone: 02 9882 2782 Facsimile:

More information

Installation instructions

Installation instructions en Installation instructions Door control TS 970 51171582_c_01.2014 0000000 0000 51171582 XXXXX 2 GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf, Germany www.gfa-elektromaten.de

More information

Installation instructions

Installation instructions Installation instructions Door control TS 971 Automatic control panel with radio Version: 51171521 -en- Version: f / 07.2015 0000000 0000 51171521 XXXXX GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 40549

More information

Operating Instructions for Control CS 300

Operating Instructions for Control CS 300 Operating Instructions for Control CS 00 GB CS 00 Gate Controls / Rev.A 5.5 . Contents. General safety instructions. Contents. Key to symbols. General safety instructions 4. Overview of products 5. Initial

More information

CS300FU SYSTEM. Pro-Line OPERATING INSTRUCTION

CS300FU SYSTEM. Pro-Line OPERATING INSTRUCTION CS300FU OPERATING INSTRUCTION Pro-Line EN 1. Contents 1. Contents 2 2. Information in this document 2 3. General safety instructions 3 4. Overview of products 4 5. Frequency Converter 6 6. Initial Operation

More information

Operating Instructions for Control CS 300

Operating Instructions for Control CS 300 Operating Instructions for Control CS 00 GB CS 00 Gate Controls / Rev. 5.5 . Contents. General safety instructions. Contents. Key to symbols. General safety instructions 4. Overview of products 5. Initial

More information

Operating Instructions for Roll-Up Door Operators / MDF

Operating Instructions for Roll-Up Door Operators / MDF Operating Instructions for Roll-Up Door Operators / MDF GB Roll-Up Door Operator / MDF / Rev. 0.0 1 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions

More information

EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453

EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453 EURO ECO / EURO deluxe DC EURO ECO DC EURO deluxe DC DC - Control Unit conforms to DIN EN DC EURO ECO DC EURO deluxe Connection -phase 0VAC motor power supply C L N PE PE L N M remove bridge when installing

More information

Sliding doors / fire doors

Sliding doors / fire doors Sliding doors / fire doors Installation Instructions for SCDmini TSm01.3 Please note that this documents relates to software for sliding doors and requires that program no. 20 is selected. If using UPS

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Installation Instructions

Installation Instructions ``````````````````````` Wolf cdn een n en Installation Instructions SDS SPRINGLESS DOOR SYSTEM 230VAC 1PH Date: 23.03.2016 Version: II-SDS-001-01 1 1 1. SAFETY DIRECTIONS Basic Directions This system has

More information

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions electronic Softstarter SAS 3...11 SAS 11PUST, 22PUST Assembly- and Commissioning Instructions Quality is our Drive. SAS 3...11, SAS 11PUST, 22PUST 1 Stand 03/17 10800.10002 Table of contents Page 1. Safety

More information

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE Comfort 800E/1000E WARNING Please read the manual carefully before installation and use. The installation of your new door opener

More information

ELEKTROMATEN ST Sliding-door-drive

ELEKTROMATEN ST Sliding-door-drive ST Sliding-door-drive for sliding doors ST 9.5 ST 80. Output torque: 90-800 Nm Output speed: 5 - rpm Control panels for ST WS 905 / TS 00.0.0 Subject to alterations. (_Db).000 ST Sliding-door-drive For

More information

Operator systems for garage doors Comfort 260, 270, 280 speed

Operator systems for garage doors Comfort 260, 270, 280 speed GB Operating instructions Last updated: 02.2014 Operator systems for garage doors Comfort 260, 270, 280 speed Table of Contents 1. General safety instructions...3 1.1 Intended use...3 1.2 Target group...3

More information

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual RESOL TLR2 Mounting Connection Handling Fault localization *48001550* 48001550 TLR2 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit. B Manual www.resol.de

More information

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10 our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70

More information

Local Control Network - building controls in perfection

Local Control Network - building controls in perfection 2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

Assembly and Operating Instructions

Assembly and Operating Instructions BECK-O-TRONIC 6 Version: Centronic en Assembly and Operating Instructions Door control unit Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must

More information

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH EN Dusty / Dusty Ex Operating Instructions Low-Cost Broken Bag Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Introduction.............................................................. 3 1.1

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

HIB Enclosed Inverter User Guide

HIB Enclosed Inverter User Guide HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Sectional and Tilting Door Opener

Sectional and Tilting Door Opener Sectional and Tilting Door Opener Installation Instructions and User Guide 600 800 1000 S/N WARNING Please read the manual carefully before installation and use. The installation of your new door opener

More information

Sectional and Tilting Door Opener Installation Instructions and User Guide

Sectional and Tilting Door Opener Installation Instructions and User Guide Sectional and Tilting Door Opener Installation Instructions and User Guide ET-600E ET-800E ET-1000E S/N WARNING Please read the manual carefully before installation and use. The installation of your new

More information

GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2

GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2 5048551A- 26/04/07 14:36 Page 1 CONTENTS GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2 PRODUCT DESCRIPTION 2 Product components 2 Types of door 2 POINTS TO CHECK PRIOR TO

More information

FMC-1/2 Tina Muting unit

FMC-1/2 Tina Muting unit Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Sectional And Tilting Door Opener

Sectional And Tilting Door Opener Sectional And Tilting Door Opener Installation Instructions and User Guide FS 600 FS 1000 FS 1200 600N 1000N 1200N FS 600-Speed FS 1000-Speed 600N 1000N S/N WARNING Please read the manual carefully before

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

Roll Up Door Operator

Roll Up Door Operator INSTRUCTIONS & OWNERS MANUAL Roll Up Door Operator 2 INDEX Preparation before installation 4. Terms and definitions 5. Pictures & names of parts 6. Mounting the weight bar 7. Installing the operator 7.

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Important instructions

Important instructions Operation manual Please read this manual, before starting the unit. It contains important notes on commissioning and handling. Keep these instructions for future reference. Be careful even if you pass

More information

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Braking Devices BR 230/ Assembly- and Commissioning Instructions electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

ST Wiring diagram. Product description. Temperature controller. Order number

ST Wiring diagram. Product description. Temperature controller. Order number ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point

More information

SINAMICS GM150 IGCT version

SINAMICS GM150 IGCT version /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /14 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds Motor for Venetian blinds: GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

Tina 10A/B/C Adaptor unit

Tina 10A/B/C Adaptor unit Original instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04) INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS 300 6720613720-00.1 SD UK/IE CONTENTS Contents Contents 2 1 Safety instructions and explanation of symbols 5 1.1 General safety instructions

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Operating instruction and technical description

Operating instruction and technical description Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with

More information

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI5000 SI / / 2007 Operating instructions Flow monitors SI5000 SI5001 704056 / 01 06 / 2007 Contents 1 Safety instructions... 3 2 Functions and features... 4 2.1 Application area... 4 2.2 Operating principle flow monitoring...

More information

Operation Instructions

Operation Instructions Operation Instructions AKKUTEC 2405 USB NBPA0616G01 device designation notes art.no. nominal input voltage nominal output voltage AKKUTEC 2405-0 USB standard device, single module NBPA0616G01001 115-230V

More information

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information

More information

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

TM 50 TM 80 USER MANUAL GARAGE DOOR OPERATORS ENGLISH TM50/80 MO911/1V0 SKRW433 SKR Note the operator s serial number here:

TM 50 TM 80 USER MANUAL GARAGE DOOR OPERATORS ENGLISH TM50/80 MO911/1V0 SKRW433 SKR Note the operator s serial number here: GARAGE DOOR OPERATORS TM 50 TM 80 USER MANUAL Note the operator s serial number here: Final Factory check by: TM50/80 MO911/1V0 SKRW433 SKR433-1 ENGLISH Content General Information Important Safety Instructions

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

EC DECLARATION OF CONFORMITY

EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY Manufacturer : Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 844 T control board, conforms to the essential safety requirements of the

More information

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment. Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow

More information

The electro-mechanical power steering with dual pinion

The electro-mechanical power steering with dual pinion Service Training Self-study programme 317 The electro-mechanical power steering with dual pinion Design and function The electro-mechanical power steering has many advantages over the hydraulic steering

More information

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE Operating instructions FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE 1547440000 IE-CL240W-PP-REMOTE 1547450000 Technical service: freecon.contactless@weidmueller.com Weidmüller

More information

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal... Safety sensor 7 Disassembly and disposal 7.1 Disassembly....5 7.2 Disposal...5 8 Appendix 8.1 Wiring example...6 Operating instructions.............pages 1 to 8 Original 9 EU Declaration of conformity

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

Manual for Inverter system type PCI05

Manual for Inverter system type PCI05 - 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause

More information