MS5000E Mach 3 Hot Sheet
|
|
- Hilary Knight
- 5 years ago
- Views:
Transcription
1 MS5000E Mach 3 Hot Sheet System Model # L2-MS5000E-RCA-3.0k Software Version # 21 EP # 1804 Base PCBA - P PCB L2000 P Rev B Base Panels MP700 P Template used: v21_C.pdf 05/25/2006.pdf 07/24/2006
2 Basic System Features and Functions Power Requirements 230VAC, 1~, 16A or 32A, 50Hz 3 wires (line, neutral, ground) System Outputs (As Configured) 230V Pump 1, 2-Speed 230V Pump 2, 2-Speed 230V Pump 3, 1-Speed 230V Circ Pump 230V Ozone 10V Spa Light 230V Audio\Visual (Stereo) 230V 3.0kW Heater Additional Options Full Feature Dolphin Remote and Spa-only Dolphin Remote Spa Monitor Connects to Main Panel terminal J70 or J71 or J72 IR or RF Dolphin Receiver Module Connects to Remote terminal 0 Ozone enerator Connects to terminal J9 MoodEFX Lighting Connects to Spa Light terminal J12 FiberEFX Lighting Connects to Spa Light terminal J12 Stereo System Connects to A.V. terminal J4 J9 K1 J30 RLY/TRIAC CF J31 J12 J17 TST J71 J72 J70 J10 J39 9 ADCM J13 J15 J17 2 J82 4 MAI MAI MAI REMOTE 0 EXT 2S P3 F ALARM SE A VAC SE B
3 W W Wiring Configuration J98 K3 F6 J57 J59 J58 J5 2-Spd W B P2 R HTR2 J53 J54 J97 5 J99 BALBOA ISTRUMETS, IC. L2000 TC MACH III P/ REV B COPYRIHT 2004 MADE I U.S.A. TB1 Use X-B CE Expander for Blower With 2-Speed P2 FUSE 0A 250V F5 BARCODE 7 J95 6 J3 J94 HTR1 3.0 kw 8 W B R 3 J32 W4 F2 FUSE T0 3A 240V F7 8 J4 W B R W3 J55 A.V. J79 J56 T1 K7 K6 K8 J1 R 2-Spd P1 B W J90 K4 K11 0 SWITCHBAK A J41 J33 J45 K9 J14 K10 J81 SWITCHBAK B J9 Circ W Pump B R R Ozone B W J83 CF K1 J30 EXT. RLY J31 J12 Spa Light TST J17 J71 J72 J70 J10 J39 9 ADCM J13 J15 J17 2 J82 Use Board for Blower With 2-Speed P2 4 EXT 2S P3 F ALARM SE A VAC SE B MAI MAI MAI REMOTE 0 J36 EXT I/O X-P CE P J4 R B W 1-Spd P3 2 Wiring Color Key eutral (Common) AC Connections Special AC Connections Line AC Connections 10 Volt Connections Relay Control Wires PCB Revision History B Production Release Connector Key Typically Line voltage Typically Line voltage for 2-speed pumps eutral (Common) round ote flat sides in connector HIPot Testing ote: Disconnect slip terminal with green wires from J90 prior to performing HiPot test. Failure to disconnect will cause a false failure of the test. Reconnect terminal to J90 after successful completion of HiPot test.
4 Electrical Service Configuration Options L1 J53 J99 BALBOA ISTRUMETS,IC. L2000 TC MACH III P/ REV B COPYRIHT 2004 MADE I U.S.A. TB1 7 J95 6 J J32 W4 F7 8 W3 Single Service (1 x 16 Amp or 1 x 32 Amp) This option is configured and shipped as the default. For 1 x 32 Amp Service: DIP Switch A2 can be O For 1 x 16 Amp Service: DIP Switch A2 must be OFF 1 K7 J57 J59 J58 BARCODE HTR2 HTR1 L2 2 J53 J99 BALBOA ISTRUMETS,IC. L2000 TC MACH III P/ REV B COPYRIHT 2004 MADE I U.S.A. TB1 J94 7 J J32 F7 W3 Dual Service Option (2 x 16 Amp) Completely remove the white wire from 6 and J32. ote: J32 and 3 are electrically identical. The white wire may be attached to either terminal before removal. DIP Switch A2 must be O L1 6 W4 8 1 K7 J57 J59 J58 BARCODE HTR2 HTR1 L3 L2 L1 1 J57 J59 J58 HTR2 J53 J99 BALBOAISTRUMETS,IC. L2000 TC MACH III P/ REV B COPYRIHT 2004 MADE I U.S.A. TB1 BARCODE 7 J95 6 HTR1 J J32 W4 F7 8 K7 W3 3-Phase Service Option IMPORTAT - Service MUST include a neutral wire, with a line to neutral voltage of 230VAC. Completely remove the white wire from 6 and J32. ote: J32 and 3 are electrically identical. The white wire may be attached to either of these terminals before removal. Completely remove the blue wire from 8 and J57. ote: J57, J58 and J59 are electrically identical. The blue wire may be attached to any of these terminals before removal. Move the brown wire from 3 or J32 to 8. DIP Switch A2 must be O
5 Configuration Options A J98 K3 J5 5 J97 F5 J3 F2 FUSE T0.3A 240V J4 J41 J33 J36 EXT I/O A B C D E F F6 J93 J54 FUSE 0A 250V J99 J53 T1 TB1 F7 7 W3 J55 J56 8 J W4 K7 K6 K8 J57 J59 J58 BALBOA ISTRUMETS, IC. L2000 TC MACH III P/ REV B COPYRIHT 2004 MADE I U.S.A. BARCODE J94 J95 3 J32 J79 J1 J90 K4 K11 0 SWITCHBAK A J45 K9 J14 K10 J81 SWITCHBAK B J9 J83 K1 J30 J31 RLY/TRIAC CF J12 TST J17 J71 J72 J70 J10 J39 9 ADCM J13 J15 J17 2 J82 4 MAI MAI MAI REMOTE 0 B C D E F HTR2 HTR1 EXT 2S P3 F ALARM SE A VAC SE B Outut Features Quadrant J1 2-Speed Pump 1 5-D Circ Pump (Separate Relay) 7-C OR Fiber Optic Light J3 1-Speed Blower (with 1-speed Pump 2) 5 to J97 3-A OR 1-Speed Pump 3 (with 1-speed Pump 2) 5 to J99 J4 Audio Visual (always hot - no relay) 5-B J5 2-Speed Pump 2 (with O Blower on J3) 5 to J98 2-A OR 1-Speed Pump 2 (See J3 and 5) J9 Ozone (Separate Relay) 7-E J12 Spa Light (10V or 230V) 8-D X-Mount P P Used for mounting any Expander Board in a plastic enclosure. Standoffs attach to heater mounting bracket. 10 VAC Light Configuration 230 VAC Light Configuration K1 J33 Instruments Incorporated J45 Light Connector K1 J56 J1 W B R K11 0 K10 Light Connector
6 Expander Options F5 2 0A 250V X-B CE P Used for a Blower output OLY when Pump 2 (J5) is a 2-speed pump. (5 connected to J98) J3 J1 F30A 250V X-P231 CE P Can replace the X-P CE in cases where branch circuit protection is needed for high amperage devices that would over-burden power input fuse F6 or F7 (4-C) on the main PCBA. on X-P632 CE connects directly to Line AC Use 7, J32, or 6 on the main L2000 PCBA, depending on AC Service Configuration. J7 J1 J4 2 X-P CE P Used for a 1-speed Pump 3 output when Pump 2 (J5) is a 1-speed pump and a blower is connected to J3. (5 connected to J97) Also used for a 1-speed Pump 4 when Pump 3 replaces a Blower on J3 F30A 250V X-P632 CE P Used for a 2-speed Pump 3 output when Pump 2 at J5 (2-A) is a 2-speed pump or when Pump 2 is a 1-speed pump and a blower are on main PCBA. on X-P632 CE connects directly to Line AC Use 7, J32, or 6 on the main L2000 PCBA, depending on AC Service Configuration. J4 J7 J5 2 Adapter P To Spa Light (J12) on L2000 (230V Setup) X-O3 CE (P 53427) To J5 on X-O3 CE X-FOW CE Kit P Special setup with X-03 CE and Adapter P to operate a fiber-optic light and color wheel. Document P 40502_F
7 DIP Switches and Jumpers Switchbank A Switchbank B 1 2 A1, Test Mode OFF A2, Low High Amp A3, Filter by Time A4, 12 Hr Time A5, Degrees F C A6, Short Timeouts A7, Cleanup Cycle OFF A8, 1Hr O 3 Supress OFF A9/A10, o Circ Pump A11, O 3 w/ P1 Low and P1 is 2-Spd B1, Pump 2 2-Speed B2, Pump 2 Enabled Disabled B3, Blower Disabled B4, o Fiber/Wheel B5, Pump 3 Enabled Disabled B6, Panel Scrunching O OFF RTC Enabled (o Jumper) DIP Switch Key A 1...Test Mode (normally Off) A 2...In O position, heater can run while any/all high-speed pumps or blowers are running (High amperage - dual 16A service, single 32A service, or 3-phase)...In OFF position, heater is disabled while any high-speed pump or blower is running (Low amperage - single 16A service) A 3...In O position, filter cycles are programmed by duration...in OFF position, filter cycles are programmed to start and end times A 4...In O position, displays time in 24 hours (military\european time)...in OFF position, displays 12 hour time A 5...In O position, displays temperature in Celsius...In OFF position, displays temperature in Fahrenheit A 6...In O position, Equipment timeout 30 minutes (4 hours for Pump 1 Low)...In OFF position, Equipment timeout 15 minutes (2 hours for Pump 1 Low) A 7...In O position, Cleanup Cycle 30 minutes after spa use/timeout, Pump 1 Low & Ozone or Circ Pump & Ozone run for 1 hour...in OFF position, no Cleanup Cycle A 8...In "O" position, Ozone suppression for one hour after pump/blower button press...in"off" position, no Ozone suppression A9 and A10...SeeFigure 2 for Circ Pump Behavior settings A 11...In O position (non-circ mode operation) Circ Pump Pump 1 is two-speed, Ozone is O in Filter & A9 A10 Behavior Cleanup Cycles only OFF OFF o Circ Pump (in any circ mode) or Circ Pump not Pump 1 is single-speed, Ozone is O with Circ Pump plumbed w/heater...in OFF position O OFF 24 Hour (non-circ mode operation) Pump 1 is two-speed, OFF O 24 Hr w/3 F Shut-Off Ozone is O with Pump 1 Low (in any circ mode) Pump 1 is two-speed, Ozone is O with Circ Pump O O Acts like Pump 1 Low (Filter Cycles, Polls) A 12...Persistent memory reset (used when spa is powering up)
8 DIP Switches and Jumpers DIP Switchbank B Key B 1...In O position, single-speed Pump 2...In OFF position, two-speed Pump 2 B 2...In O position, Pump 2 enabled...in OFF position, Pump 2 disabled B 3...In O position, Blower enabled with Pump 2 Low relay...in OFF position, Blower disabled B 4...In O position, Fiber and Wheel instead of Spa Light...(on circ relay if A9, A10 off, external relay otherwise)...in OFF position, Spa light enabled B 5...In O position, Pump 3 enabled (Jets 3 replaces Blower on Aux panel)...in OFF position, Pump 3 disabled B 6...In O position, Alternate Panel layout...(ml900 scrunching enabled - ML550 and ML700 Jets 3 replaces Blower)...In OFF position, ormal Panel layout Jumper on 1 Pin only enables Real Time Clock function, for use with time capable panels. Jumper on Pin 1 and 2 disable RTC function for use with non-time capable panels (not included).
9 Ozone Connections ote: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Account Manager for information on purchasing a pin-removal tool. Ozone connector configuration for 230VAC 50Hz: Black or Brown Line Conductor Empty White or Blue eutral Conductor Empty L Flat sides of sockets as shown J30 J31 J12 J70 MAI MAI Line - Black or Brown conductor ot used eutral - White or Blue conductor ot used J14 K10 J9 J10 0 J39 9 ADCM REMOTE 0 SWITCHBAK B EXT. RLY CF J83 J13 J15 J17 2 J82 4 EXT 2S P3 F ALARM SE A VAC SE B
10 Panel Configurations MP700 P with o Overlay (Customer supplied) Connects to Main Panel terminal J70, J71, or J72 on Main PCBA must be OFF (1 pin only)
WN501Z Tech Sheet MANDERASPA. Winer Spas. System PN System Model # GS5-WN501Z-RCA-3.0 Software Version # 38 EPN # 2854
W50Z Tech Sheet MADERASPA Winer Spas System P 559-0 System Model # S5-W50Z-RCA-.0 Software Version # 8 EP # 85 Base PCBA - P 559 PCB S500Z - P 05 Rev B Base Panels VL0 (LCD Lite Duplex) P 509 VL0 (LCD
More informationGS510SZ Tech Sheet. Balboa Instruments. System PN System Model # GS5-GS510SZ-RCA-3.0 Software Version # 43 EPN # 2765
GS50SZ Tech Sheet Instruments System P 557-0 System Model # GS5-GS50SZ-RCA-.0 Software Version # EP # 765 Base PCBA - P 558-0 PCB GS500Z - P 05 Rev B Base Panels VL700S P 58 VL70S (Serial Standard) P 589-0
More informationPart Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element
BP500 Tech Sheet Balboa Water Group Part Number: 55697-04 4kW 800 Incoloy Element 55967-03 3kW 800 Incoloy Element 55700-04 With 4kW Titanium Element 55968-03 3kW 800 Titanium Element Compatible Plumbing
More informationTroubleshooting & Service for GL/GS Systems. 50 Hz
Troubleshooting & Service for GL/GS Systems 50 Hz 1 Balboa s Patented M7 Technology TOPSIDE CTROL PAEL The control panel activates functions at the touch of a button. Each function will echo from the circuit
More informationCOAST SPAS TSPA-MP SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.
COAST SPAS TSPA-MP SERVICE MANUAL Gecko Electronics Inc. Visual step-by-step guide to easily identify & correct technical problems! Table of Contents Power & Ground Check Electrical Wiring 4 GFCI 5 Programming
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11
Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified
More informationOnCommand Troubleshooting Guide Hayward Industries
OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters
More informationINSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern
More informationTroubleshooting Manual
DISPLAY HOLD/RELEASE SPA AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 Troubleshooting Manual HEATERS POOL SPA SOLAR MENU CANCEL BACK FORWARD ENTER Table of Contents This is the Troubleshooting Manual for
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these
More informationINOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual
INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationInstallation and Operation Manual
Installation and Operating Data Installation and Operation Manual Jandy Laminar Jet Pulse Controller LPC4 H0566900A WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion
More informationTable of Contents. Balboa Control Service Checklist. Topside Control Panel. System Description. Panel Messages. Wiring Checks.
50 HzTechnical Service Manual Table of Contents Balboa Control Service Checklist Preface....................................3 Tools Required..............................3 System Components Required...................3
More information2011 EXPORT 50HZ PARTS LIST RRP INC VAT 1ST January 2011
Part Number Description Balboa Entry Level Replacement Parts(Cascade Tortola) EL-67010 LA500 Complete, w / Heater & Sensors Balboa 1P N / Air, 50Hz 695.00 EL-67012 LA500 Pack Only, No Heater or Sensors,
More informationInstallation Instructions & Users Manual
Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL
More informationNon-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.
End User Disclaimer End User Disclaimer: United Spa Controls systems have absolutely no end user serviceable parts. United Spa Controls does not authorize attempts by the spa owner/ user to install or
More informationInstallation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Double Oven Electric Range MER6549BAQ/W MER6769BAQ/W Due to possibility of personal injury or property damage, always contact an authorized technician to service or repair this unit.
More informationPULSE-8: MASTER PULSATION CONTROL
PULSE-8: CONTROL Version - February 2006 For Software Version V1.02 Part Number - 39-0020 CONTROL: INDEX GOOD PRACTICE: Mains Supply. A separate mains supply and earth running directly from the consumer
More informationLX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS
LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS: All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should be observed
More informationTechnical Service Manual
2004 Technical Service Manual Table of Contents Balboa Control Service Checklist Preface..................................... 4 Tools Required............................... 4 System Components Required....................
More informationDIESEL Engine Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More informationFincor Series 2230 MKII/2240
Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new
More informationThe POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.
The POWER In PRESENTATION PRODUCTS Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137
More informationFincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible
DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific
More informationAir-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.
Supplement #1 -A, -B Air-Cooled Scroll Compressor Chillers Models 010A to 034A Models 026B to 130B Revised Electrical Data Tables Replaces Electrical Tables in PM -6, IOMM 1, and IOMM -5 Engineered for
More informationOwners Manual. Features
Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks,
More informationInduction Power Supplies
Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.
More information2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /
Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationFIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER
APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent
More informationContents. Delivering your Canadian Spa. Pre-Delivery Guide.
Contents CHOOSE YOUR LOCATION PLANNING PERMISSION PRE-DELIVERY PREPARATION DELIVERY AND ACCESS Delivering your Canadian Spa POSITIONING OF YOUR SPA SETTING UP YOUR HOT TUB/SPA INSTALLATION AND ELECTRICAL
More informationSingle & Three-Phase Soft Starters
Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More informationBL-40 UNIVERSAL CIRCUIT BOARD REPLACEMENT KIT
ALLIED INNOVATIS, LLC Manufacturing the Product Lines of Len Gordon 7215 Bermuda Rd Las Vegas NV 89119-4304 BL-40 UNIVERSAL CIRCUIT BOARD REPLACEMENT KIT IMPORTANT INSTALLATI INSTRUCTIS - PLEASE READ!
More informationNordson Airless Nozzle Tester
Instruction Sheet P/N Nordson Airless Nozzle Tester. Introduction The Nordson airless nozzle tester is used to test the flow rate of flanged airless nozzles. The results of the tests can be used to determine
More informationDocument: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
More information3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter
pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color
More information2. RUN JUMPER INPUT A Run Jumper is factory installed as shown on the enclosed wiring diagram.
Amplitude Controller Model 6400.1 & 6400.2 Series Model 6400.1 Listed, File No. E183233 Input: 120 VAC, 50/60 HZ. Output: 0120 VAC Single Unit Fuse Size: 15 AMPS 80% Duty Cycle at Rated AMPS ELECTRICAL
More informationOperating & Installation Manual
Operating & Installation Manual Variable Speed Controller for DC Motors Up To /2 hp 5 VAC, 50/60 Hz, Single-Phase Input Models: 7-2 & 7-22 85-26 Rev. E Table of Contents.0 Safety Considerations...................................................
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationRCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2
RCP200 Series Motor Controls Instruction Manual Model RCP202-000 Model RCP205-000 Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2 You ve just purchased the best! Congratulations! You ve just purchased
More informationDC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC
DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC Instruction Manual D2-3453 The information in this manual is subject to change without notice. Throughout this manual, the following notes
More informationECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications
An ISO 9001:2015 Registered Company ECO3-601/602 EcoStar III 2009-2019* Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications * In 2017-2018, the ignition switches on Chevy Express
More informationACR RECESSED AIRCURTAIN ELECTRICALLY HEATED, AMBIENT & LPHW INSTALLATION AND OPERATING MANUAL
Instruction Manual. ACR RECESSED AIRCURTAI ELECTRICALLY HEATED, AMBIET & LPHW ISTALLATIO AD OPERATIG MAUAL IDEX Section General information ----------------------------------------------------------- 1
More informationPARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
1/2 SIZE CONVECTION TJ CINNAMON MCO-E-5 PARTS LIST Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com TJ Cinnamon Oven (Rev 01) Page
More informationELECTRICAL PANELS. Chap.
ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch
More informationGTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More informationPREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.
EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4
More informationGLM SERIES CONTROL Users Manual Rev:
GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction
More informationElectronic Products ELECTRONIC MAINTENANCE
SubDrive2W, 75, 100, 150, 300, MonoDrive, and MonoDrive XT Should an application or system problem occur, built-in diagnostics will protect the system. The FAULT light or digital display on the front of
More informationSMT-150 Installer Manual
SMT-150 Installer Manual 3 Stage Digital HVAC Controller Version 1.0 Version History January 2019 Version 1 - Original Document Thank you for your purchase of this premier product. Please take the time
More informationPRODUCT INFORMATION BULLETIN
724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationTS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY
TS1 SMARTBOB REMOTE UNIT INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 No. 98th Street P.O. Box 29709 Lincoln, NE 68507 Lincoln, NE 68529 (402) 434-9102
More informationInstallation Instructions
AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in
More informationAnthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A
Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A 99-16999-0000 Table of Contents 1. Removing Fluorescent Lighting... 4 1.1. Detach the lens assembly... 4 1.2. Remove
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationPivot Point Lite Wiring Manual
2009-10 Pivot Point Lite Wiring Manual (small square single circuit board design) Section 1 Pages 2-3 Pivot wiring to monitor and/or stop the irrigation system. Section 2 Page 4 Section 3 Page 4 Simple
More informationThree-Phase Soft Starters
Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229
More informationPOWERLINE 2000 Energy Management System TM
Display Panel TM The PowerLine 00 EMS is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed in the standard main distribution
More informationGTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM V Gas Turbine Flow Monitor Operation / Installation
More informationVertical Vinyl Curtain Door
Vertical Vinyl Curtain Door Face Mount Installation Instructions System Overview: Your Aleco Vinyl Vertical Curtain Door is a high quality, high performance flexible door system based on proven components
More information2904 Power Supply Installation Instructions I-EA00041
FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and
More informationHAN-L62 MOUNTING PLATE
DATE : 23/01/2013 BULLETIN NO : L62-132E-INST-REV11 SUPERSEDES : 30/11/2012 Z ABN 92 431 001 201 INSTALLATION INSTRUCTIONS FOR MODEL HAN-L62 / PCB-132 WITH EARTH SHIELD CABLE MICROPROCESSOR AIR CONDITIONING
More informationDIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual
DI Rail US Model: DI-US 48-5 Installation/Operation Manual Table of Contents Section age Section age Quick Start 2 1) General Information 4 Materials rovided 4 Optional quipment 4 2) Safety Information
More informationIdle Free Systems, Inc. Reference Guide System Component Information
Idle Free Systems, Inc. Reference Guide System Component Information #68004 REV 3 #68004 REV 3 Idle Free Reference Sheets System Components & Trouble shooting Table of Contents RF # 101.0 102.0 103.0 104.0
More informationCellwatch Battery Monitoring Systems
Cellwatch Battery Monitoring Systems A battery can fail overnight leaving an entire power system without backup capability... So what did your batteries do today? If you want to know, read on... Cellwatch
More informationFlight Systems. Replacement for KASSEC DESCRIPTION
DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most
More informationBLOWER VACUUM SWITCH FAILED OPEN
F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check
More informationUL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD
UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you
More informationMCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP
MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # MCO E5 Elec (Rev
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationPBA Series Prelube Controls
VARNA Products Engineered Innovation PBA Series Prelube Controls Simple, Compact, Industrial Full featured control for running prelube from the control or from a remote station Easy internal wiring connections
More informationLP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999
/2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table
More informationINSTALLATION INSTRUCTIONS
TT-338 /0 INSTALLATION INSTRUCTIONS Original Issue Date: /0 Model: Transfer Switches with Programmable Controllers Market: ATS Subject: Transformer Kits GM6369 (480 V) and GM6859 (600 V) Introduction A
More informationANZI Transfer Switch and Generator Wiring Installation Addendum
ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE
More informationOwners Manual. Features
Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks,
More informationSITESTAR ELECTRONICS CABINET DESCRIPTION
SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationFactory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide
Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature
More informationAutomation Devices, Inc West Ridge Road, Fairview, PA AUTODEV.COM
Amplitude Controller Model 6400.1 GENERAL PURPOSE Automation Devices, Inc. 7050 West Ridge Road, Fairview, PA 164152099 Email SALES@AUTODEV.COM AUTODEV.COM Input: 120 VAC, 50/60 HZ. (Operating range 90130
More informationAxpert-CSS AMTECH DRIVES Axpert-CSS Amtech
The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationMPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene
MPS AND MPS PR¼ 16 OUTPUT DEMAND PENTAIR CLEAN AIR SYSTEMS MPS DESCRIPTION The Model MPS has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing
More informationCD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER
CD100 Series SINGLE COLUMN CARD DISPENSER Operators Manual Contents 1 Specifications...1 2 Installation...2 2.1 Unpacking and inspection...2 2.2 Installation...2 2.3 Electrical Connections...2 2.4 Initial
More informationSOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.
AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CONTROLS INC. www.goldlinecontrols.com 888-921-7665 IMPORTANT SAFETY
More information33 FLASH CODE 33 - TBS HIGH
33 FLASH CODE 33 - TBS HIGH Section Page 33.1 DESCRIPTION OF FLASH CODE 33... 33-3 33.2 SAE J1587 EQUIVALENT CODE FOR FLASH CODE 33... 33-3 33.3 TROUBLESHOOTING FLASH CODE 33... 33-4 Figure 33-1 Turbo
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationControl Parts. AquaLink Touch Replacement Parts 2011 ZODIAC POOL SYSTEMS CATALOG 141. Control Parts
AquaLink Touch Replacement Parts 0 R000 Control Panel Complete, Wired Flush Mount, AquaLink Touch, R-Kit $,00.00 R000 Back Housing W/ RS PCB, Wired, Flush Mount, AquaLink Touch, R-Kit $. R000 Power Booster,
More informationControl. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)
Part B, Section 2 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, G) Manifold 4-Port (A) 6-Port (B, C) 2-Port (S, T) Vista Standard (V) B 2-0
More informationMitsubishi. VFD Manuals
Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi
More information