1 General Specifications GS 1C2H1-E Model EJ11W, EJ11N and EJ11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium from entering directly into the -sensing assembly of the differential transmitter, they are connected to the transmitter using capillaries filled with fill fluid. Model EJ11W, EJ11N and EJ11Y Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and. They output a 4 to 2 ma DC signal corresponding to the measured differential. The transmitters also feature remote setup and monitoring through communications with the model BT2/1 BRAIN TERMINAL, CENTUM-CS/XL system, etc. STANDARD SPECIFICATIONS Measurement Ranges: Capsule Measurement Span Measurement Range M H V 2.5 to 13 kpa {25 to 13 mmh 2 O} 14 to 7 kpa {.14 to 7 kgf/cm 2 }.2 to 13.7 MPa {2. to 14 kgf/cm 2 } -13 to 13 kpa {-13 to 13mmH 2 O} -1 to 7 kpa {-1 to 7 kgf/cm 2 } -.1 to 13.7 MPa {-1 to 14 kgf/cm 2 } T1E.EPS Output Signal: 4 to 2 ma DC, 2-wire system Failure Alarm: Output status at CPU failure; Up-scale: 11%, 21.6 ma DC or more (fixed) Output status at Hardware error; Up-scale: 11%, 21.6 ma DC (standard) Down-scale: 2.5%, 3.6 ma DC Conditions of Communication Line: Power supply voltage; 1 to 42 V DC * Load resistance; See Figure 2. on page. Note: In case of an intrinsically safe transmitter, external load resistance includes safety barrier resistance. Communications distance; 2 km *, when polyethylene-insulated PVC-sheathed control (CEV) cables are used. Load capacitance;.22 F * or less. Load inductance; 3.3 mh * or less. Spacing from power line; 15 cm or more. * For general type and flameproof type Accuracy: See Table 1. (For wetted parts material code H, T or U, refer to GS 1C2V1-E.) Ambient Temperature Limits: -4 to 6 C (-4 to 14 F) (general-use type) -3 to 6 C (-22 to 14 F) (with integral indicator) (See Optional Specifications for Explosion-protected types) (Note: The ambient temperature limits must be within the fill fluid operating temperature range, see table 4.) Ambient Temperature Effect: See Table 1. (For wetted parts material code H, T or U, refer to GS 1C2V1-E.) Process Temperature Limits: See Table 4. Ambient Humidity Limits: 5 to 1 % R.H. (at 4 C) Working Pressure Range: 2.7 kpa abs {2 mmhg abs} to flange rating. For atmospheric or below, see Figure 1. Static Pressure Effect: See Table 1. (For wetted parts material code H, T or U, refer to GS 1C2V1-E.) Power Supply Effect:.5 %/V (21.6 to 32 V DC, 35 ) Mounting: Transmitter ; 2-inch pipe mounting Diaphragm seals ; flange mounting Mounting Flange Rating: See Model and Suffix Codes. Flanges conforming to ANSI are serrated on their gasket surfaces (ANSI B16.5). (Note: for model EJ11W wetted parts material code H, T, or U, no serration is done.) Yokogawa Electric Corporation Nakacho, Musashino-shi, Tokyo, 1-75 Japan Phone: Fax.: GS 1C2H1-E Copyright Dec th Edition Apr. 26
2 Degrees of Protection: IP67, NEMA4, JIS C92 immersion proof Explosion-protected Construction: See Optional Specifications. Electrical Connection: See Model and Suffix Codes. Amplifier Housing: Cast aluminum alloy Painting: Polyurethane resin baked finish For case ; frosty white (Munsell 2.5Y.4/1.2) For cover ; deep sea moss green (Munsell.6GY3.1/2.) Integral Indicator: LCD digital indicator (optional) Transmitter Material: Cover flange ; JIS SUS316 Cover flange bolts ; See Model and Suffix Codes. Diaphragm Seals Material: Diaphragm and other wetted parts ; See Model and Suffix Codes. Capillaries ; JIS SUS316 Protection tubes ; JIS SUS34 PVC-sheathed (Max. operating temperature of PVC, 1 C (212 F)) Fill fluid ; See Table 4. 2 EMC Conformity Standards: AS/NZS CISPR11 Damping Time Constant: (Sum of time constants for amplifier assembly and capsule assembly including diaphragm seals) Amplifier assembly time constant ; Can be set in 9 increments from.2 to 64 sec. Capsule assembly time constant ; Approximate values obtained at normal temperature when the capillary length is 3 m and the fill fluid code is A. Capsule Time Constant (sec) M Approx..9 H Approx..7 V Approx..7 T2E.EPS External Zero Adjustment: Continuously adjustable Resolution ;.1 % of span Zero Adjustment Limits: Zero can be fully elevated or suppressed as long as low and high range value are within the measurement range limits of the capsule. Tag Plate: JIS SUS34 Weight: 24 kg (52.9 lb) (Model EJ11W flange with Mounting bracket) Table 1. Accuracy, Ambient Temperature Effect, and Static Pressure Effect (With Linear Output, As Percent of x ) *1 Capsule M, H, V Accuracy.2 % Pref ( x ) % For x Pref For x < Pref Ambient temperature effect *2 Static effect Zero shift Total shift *4 Zero shift Total shift *3*4 (.2+.3 Pref x ) %/5 C change 1.1 %/5 C change Pref (.7+.4 x ) %/5 C change. %/.9 MPa {1 kgf/cm 2 } change Pref (.1+.7 x ) %/.9 MPa {1 kgf/cm 2 } change.1 %/.9 MPa {1 kgf/cm 2 } change Pref (.2+. x ) %/.9 MPa {1 kgf/cm 2 } change For x Pref For x < Pref For x Pref For x < Pref For x Pref For x < Pref T5E.EPS *1: (1) x is the highest value among the absolute values of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. x Percent of span = Percent of x span Accuracy of square root output is as shown in Table 3. (2) Characteristics in Table 1 are for cases where the wetted parts material code S is selected. (As for other codes, see GS 1C2V1-E.) *2: The ambient temperature effect specification applies to the range of (32) to 6 C (14 F). (Below C (32 F), value is three times that given in the table.) *3: Values for measurement span 4.9 kpa {5 mmh 2 } or below are estimated values. *4: Combined zero and span shift
3 3 Table 2. Value of Pref Table 3. Accuracy for Square Root Output Capsule M H V Pref 2 kpa{2 mmh 2 O} 1 kpa{1 kgf/cm 2 }.7 MPa{7 kgf/cm 2 } Square Root Output 5 % or greater 5 % down to dropout point Accuracy Same as accuracy for linear output 5 (linear output accuracy) (square root output [%]) T6E.EPS T7E.EPS Process temperature *1 Ambient temperature *2 Fill Fluid Code A -1 to 25 C (14 to 42 F) -1 to 6 C (14 to 14 F) Table 4. Process Temperature and Ambient Temperature Silicone Oil Fluorinated Oil Ethylene Glycol Fill Fluid Code B -3 to 1 C (-22 to 356 F) -15 to 6 C (5 to 14 F) Working See Figure 1 Specific gravity *3 Fill Fluid Code C 1 to 3 C (5 to 572 F) 1 to 6 C (5 to 14 F) Fill Fluid Code D -2 to 12 C (-4 to 24 F) -2 to 6 C (-4 to 14 F) 51 kpa abs or more {3 mmhg abs} Fill Fluid Code E -5 to 1 C (-5 to 212 F) -4 to 6 C (-4 to 14 F) Vacuum not allowed to TE.EPS *1: See Figure 1. Working Pressure and Process Temperature. Process Temperature Limits for the wetted parts material tantalum (code T) is -1 to 2 C (14 to 392 F) *2: This ambient temperature is the transmitter ambient temperature. *3: Approximate values at a temperature of 25 C (77 F) *4: The differential transmitter should be installed at least 6 mm below the high (HP) process connection. However, this value (6 mm) may be affected by ambient temperature, operating, fill fluid or material of the wetted diaphragm. Contact YOKOGAWA when the transmitter can not be installed at least 6 mm below the HP process connection. Process temperature for fill fluid code B Transmitter ambient temperature range (For fill fluid code A, B) Process temperature for fill fluid code A Process temperature for fill fluid code C Flange max. working 1 {75} Working kpa abs {mmhg abs} Atmospheric 1 {75} 2.7 {2} 1 {7.5}.1 {.75} Process Temperature (C) Figure 1. Working Pressure and Process Temperature F1E.EPS
4 4 MODEL AND SUFFIX CODES Model EJ11W Model Suffix codes Description EJ11W Diaphragm sealed differential transmitter (Flush diaphragm type) Output signal Measurement span (capsule) -D 4 to 2 ma DC with digital communication (BRAIN protocol) M H V Wetted parts material *4 S H T U Process flange rating J1 J2 J4 A1 A2 A4 Process flange size/ material D E Cover flange bolts material A B Fill fluid -A *1 -B -C *2 -D *3 -E A Always A Installation - -2 Electrical connection Integral indicator D N 2.5 to 13 kpa {25 to 13 mmh 2 O} 14 to 7 kpa {.14 to 7 kgf/cm 2 }.2 to 13.7 MPa {2. to 14 kgf/cm 2 } [Diaphragm] [Others] JIS SUS316L JIS SUS316L Hastelloy C-276 *5 Hastelloy C-276 *5 Tantalum Tantalum Titanium Titanium JIS 4K ANSI class 15 ANSI class 3 ANSI class 6 3-inch ( mm)/ JIS S25C 3-inch ( mm)/ JIS SUS34 JIS SCM435 JIS SUS63 [Process Capillary length (m) Specify capillary length from 1 to 5 m in. (Example for 2 m: 2) Vertical impulse piping type, left side terminal box Vertical impulse piping type, right side terminal box G 1/2 female G 3/4 female 1/2 NPT female G 1/2 female, with external indicator connection and a blind plug G 3/4 female, with external indicator connection and a blind plug 1/2 NPT female, with external indicator connection and a blind plug Digital indicator (None) Mounting bracket A JIS SECC B JIS SUS34 N (None) Optional codes [Ambient temperature] temperature] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C -4 to 6 C / Optional specification 2-inch pipe mounting (flat type) 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Example: EJ11W-DMSJ1DA-AA2-2NA/ T9E.EPS *1: In case of wetted parts material code T (Tantalum), the process temperature limit is -1 to 2 C. *2: Wetted parts material code T (Tantalum) cannot be applied. *3: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment for the wetted parts is required, specify optional code K1. *4: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 ºC [32 ºF] or above). Contact Yokogawa for detailed information of the wetted parts material. *5: Hastelloy C-276 or ASTM N1276.
5 5 Model EJ11N Model Suffix codes Description EJ11N Diaphragm sealed differential transmitter (Extended diaphragm type) Output signal Measurement span (capsule) Wetted parts material *3 -D 4 to 2 ma DC with digital communication (BRAIN protocol) M H Process flange rating J1 J2 A1 A2 Diaphragm extension length Process flange size/material G H B Cover flange bolts material A Fill fluid S A -B -C -D *1 -E 2.5 to 13 kpa {25 to 13 mmh 2 O} 14 to 7 kpa {.14 to 7 kgf/cm 2 } X 2 = 5. mm X 2 =11.6 mm X 2 =152.4 mm 4-inch (1 mm)/ JIS S25C 4-inch (1 mm)/ JIS SUS34 JIS SCM435 JIS SUS63 B Always B [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 ANSI class 15 ANSI class 3 [Process [Ambient temperature] temperature] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C -4 to 6 C Capillary length (m) *2 Specify capillary length from 1 to 5 m in. (Example for 2 m: 2) Installation - -2 Vertical impulse piping type, left side terminal box Vertical impulse piping type, right side terminal box Electrical connection Integral indicator D N G 1/2 female G 3/4 female 1/2 NPT female G 1/2 female, with external indicator connection and a blind plug G 3/4 female, with external indicator connection and a blind plug 1/2 NPT female, with external indicator connection and a blind plug Digital indicator (None) Mounting bracket A B N JIS SECC JIS SUS34 (None) 2-inch pipe mounting (flat type) 2-inch pipe mounting (flat type) Optional codes / Optional specification The marks indicate the most typical selection for each specification. Example: EJ11N-DMSJl2GA-AB2-2NA/ T1E.EPS *1: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment for the wetted parts is required, specify optional code K1. *2: The specified capillary length includes the diaphragm extension length(x 2 ) and the flange thickness(t). *3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 ºC [32 ºF] or above). Contact Yokogawa for detailed information of the wetted parts material.
6 6 Model EJ11Y Model Suffix codes Description EJ11Y Output signal Measurement span (capsule) High side (extended diaphragm type) wetted parts material *1*4 Diaphragm sealed differential transmitter (Combination of extended diaphragm and flush diaphragm type) -D 4 to 2 ma DC with digital communication (BRAIN protocol) M H Process flange rating J1 J2 A1 A2 Diaphragm extension length Process flange size/material P Q Cover flange bolts material A B Fill fluid S A -B -C -D *2 -E C Always C Installation to 13 kpa {25 to 13 mmh 2 O} 14 to 7 kpa {.14 to 7 kgf/cm 2 } [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 ANSI class 15 ANSI class 3 X 2 = 5. mm X 2 =11.6 mm X 2 =152.4 mm High side 4-inch (1 mm)/ JIS S25C Low side 3-inch ( mm)/ JIS S25C High side 4-inch (1 mm)/ JIS SUS34 Low side 3-inch ( mm)/ JIS SUS34 JIS SCM435 JIS SUS63 [Process [Ambient temperature] temperature] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C -4 to 6 C Capillary length (m) *3 Specify capillary length from 1 to 5 m in. (Example for 2 m: 2) Vertical impulse piping type, left side terminal box Vertical impulse piping type, right side terminal box Electrical connection Integral indicator D N G 1/2 female G 3/4 female 1/2 NPT female G 1/2 female, with external indicator connection and a blind plug G 3/4 female, with external indicator connection and a blind plug 1/2 NPT female, with external indicator connection and a blind plug Digital indicator (None) Mounting bracket A JIS SECC B JIS SUS34 N (None) 2-inch pipe mounting (flat type) 2-inch pipe mounting (flat type) Optional codes / Optional specification The marks indicate the most typical selection for each specification. Example: EJ11Y-DMSJ12PA-AC2-2NA/ T11E.EPS *1: Low side (Flush diaphragm) wetted parts material: Diaphragm; SUS3l6L, Others; SUS316L. *2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment for the wetted parts is required, specify optional code K1. *3: The specified capillary length of high side(extended diaphragm side) includes the diaphragm extension length(x 2 ) and the flange thickness(t). *4: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 ºC [32 ºF] or above). Contact Yokogawa for detailed information of the wetted parts material.
7 7 OPTIONAL SPECIFICATIONS Painting Item Color change Coating change Lightning protector Oil-prohibited use Calibration units No serration *1 Teflon film *2 Operating temperature correction *3 Capillary without PVC sheaths CPU failure alarm down-scale *4 Gold-plate *5 Mill Certificate EJ11W EJ11N EJ11Y Pressure test/ Leak test Certificate *9 JIS ANSI Description Amplifier cover only Epoxy resin-baked coating *1 Transmitter power supply voltage: 12.5 to 32 V DC Allowable current: Max. 6 A (14 µs), Repeating 1 A (14 µs) 1 times Degrease cleaning treatment P calibration (psi unit) bar calibration (bar unit) (See Table 5.) M calibration (kgf/cm 2 unit) No serration work on the flange gasket surface (for ANSI flange only) Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil. Operation range: 2 to 12 C, to 2 MPa(Not applicable for vacuum service). Adjusting range: C to Maximum temperature of specified fill fluid. When ambient temperature exceeds 1 C, or use of PVC is prohibited Output status at CPU failure and hardware error for 5%, 3.2 ma DC or less with attached user selectable high-low jumper switch. Inside of isolating diaphragms(fill fluid side) are gold plated, effective for hydrogen permeation. Process flange, Block Process flange, Block, Pipe, Base High side: Process flange, Block, Pipe, Base Low side: Process flange, Block 1K : 2 MPa{2 kgf/cm 2 } 2K : 5 MPa{5 kgf/cm 2 } 4K : 1 MPa{1 kgf/cm 2 } Nitrogen (N 2) Gas *7 15 : 3 MPa{29. kgf/cm 2 } Retention time: 1 minutes 3 : 7.7 MPa{77 kgf/cm 2 } *6 3 : 7 MPa{7 kgf/cm 2 } * 6 : 14 MPa{14 kgf/cm 2 } *6 *1: Not applicable for model EJ11W with Wetted part material code H, T, or U, whose gasket contact surface are not serrated as standard specifications. *2: Teflon film can only be specified for model EJ11W. *3: Specify the process operating temperature for zero correction. Example: Zero correction by process temperature 9 C. *4: The direction of hardware error alarm is user selectable by BT2. *5: Applicable for wetted parts material code S and H. *6: Applicable for model EJ11W. *7: Pure nitrogen gas is used for oil-prohibited use (Optional code K1) *: Applicable for model EJ11N and EJ11Y. *9: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4. *1: Not applicable for color change option. Table 5. Calibration Units Measurement Optional code Span and Range D1 (psi Unit) D3 (bar Unit) D4 (kgf/cm 2 Unit) Span 1 to 52 inh 2 O 25 to 13 mbar 25 to 13 mmh 2 O M Range -52 to 52 inh 2 O -13 to 13 mbar -13 to 13 mmh 2 O Code P X1 A K1 D1 D3 D4 Q T R V C1 A1 M5 M6 M7 T31 T32 T33 T36 T37 T3 T39 T12E.EPS EJ11W EJ11N, Y H V Span 56 to 2 inh 2 O 14 to 7 mbar.14 to 7 kgf/cm 2 Range -4 to 2 inh 2 O -1 to 7 mbar -1 to 7 kgf/cm 2 Span 4 to 2 psi 2. to 137 bar 2. to 14 kgf/cm 2 Range -15 to 2 psi -1 to 137 bar -1 to 14 kgf/cm 2 M Span 1 to 52 inh O 2 25 to 13 mbar 25 to 13 mmh O 2 Range -52 to 52 inh 2 O -13 to 13 mbar -13 to 13 mmh 2 O H Span 56 to 2 inh 2O 14 to 7 mbar 2.14 to 7 kgf/cm Range -4 to 2 inh 2 O -1 to 7 mbar -1 to 7 kgf/cm 2 T13E.EPS
8 OPTIONAL SPECIFICATIONS (For Explosion Protected types) Item Description Code TIIS Flameproof Approval, Ex do IIC T4X *2 *3 Certificate: TC131 (Without integral indicator) TC1311 (With integral indicator) JF3 Amb. Temp. : -2 to 6 C, Max. Process Temp. : 12 C Explosionproof type FM Explosionproof Approval Applicable standard: FM36, FM3615, FM31, NEMA 25, ANSI/NFPA 7 Class I, II and III, Division 1, Groups B, C, D, E, F and G. FF1 Outdoor hazardous locations (NEMA 4), Temperature class : T6 Electrical connection : 1/2 NPT female, Amb. Temp. : -4 to 6 C TIIS Intrinsically Safe Approval, i3ag4 *2 *5 *6 (Using Model BARD- safety barrier : Model BARD-4 can also be used.) Vm : 31.5 V DC, Im : 29.2 ma, Pm :.92 W, Load inductance : 1. mh or less, JS11 Load capacitance :.4 µf or less Amb. Temp. : -1 to 6 C, Max. Process Temp. : C Intrinsically safe type FM Intrinsically Safe Approval *4 Class I Division 1 groups A, B, C and D Class II Division 1 groups E, F and G, Class III Division 1 Vmax : 31.5 VDC Imax : 93 ma Pmax : 1.1 W Ci=2 nf Li=1.4 mh Temperature Class : T4 Outdoor hazardous locations (NEMA 4) Amb. Temp. : -2 to 6 C FS1 Electrical connection : G1/2 female 1 pc. G11 Attached flameproof packing Applicable cable O.D. : to 12 mm 2 pcs. G12 adapter *1 Electrical connection : G3/4 female 1 pc. G21 Applicable cable O.D. : 1 to 16 mm 2 pcs. G22 T14E.EPS *1: If cable wiring is to be used to a TIIS flameproof transmitter, do not fail to add the YOKOGAWA-assured flameproof packing adapter. *2: TIIS (The Technology Institution of Industrial Safety) Certification is a new notation for the explosionproof approval in Japan instead of JIS. *3: In case the ambient temperature exceeds 5 C, use heat-resistant cables with maximum allowable temperature of 75 C or above. *4: Model BARD- is not applicable. *5: The communication distance is about m when using polyethylene-insulated PVC sheathed control (CEV) cables. *6: See certificate list of TIIS intrinsically safe approval below. Without lightning protector (option code /A) With lightning protector (option code /A) Connection to BARD- T56212 T56213 Connection to BARD-4 T54512 T21E.EPS 6 External load resistance R () 25 R= E ;;;; Communication ;;;; applicable Power supply voltage E (V DC) range F2E.EPS Figure 2. Relationship Between Power Supply Voltage and External Load Resistance <Settings when Shipped> Tag Number Output Mode Display Mode Operation Mode Damping Time Constant *2 Calibration Range Lower Range Value Calibration Range Higher Range Value Calibration Range Units As specified in order *1 Linear unless otherwise specified in order Linear unless otherwise specified in order Normal unless otherwise specified in order 2 sec. As specified in order As specified in order Selected from mmh 2 O, mmaq, mmwg, mmhg, Pa, hpa, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh 2 O, inhg, fth 2 O, or psi. (Only one unit can be specified.) T15E.EPS *1: Up to 16 alphanumeric characters (including - and ) will be entered in the amplifier memory. *2: If using square root output, set damping time constant to 2 sec. or more.
9 9 DIMENSIONS Model EJ11W Unit: mm (approx. inch) 34 f t 31(1.22) n-h 9 *1 (3.54) D C 134(5.2) Wetted parts material code U (Titanium) Shrouding bolts (for TIIS flameproof type) External indicator conduit connection (Optional) Ground terminal Conduit connection 6 (2.6) Low side 125 (4.92) 193 (7.6) 2-inch pipe mounting bracket (Optional) 7 (2.76) High side 15 (.59) 53 ( 2.9) 225(.6) 111(4.37) 2-inch pipe (O. D. 6.5mm) Zero adjustment 112(4.41) 4 17(6.69) (1.9) 97 (3.2) 124(4.) 224(.2) 47 (1.5) *1: Indicates inside diameter of gasket contact surface. Process flange size: 3-inch ( mm) Flange Rating JIS 4K ANSI Class 15 ANSI Class 3 ANSI Class 6 D C 15(7.2) 15(5.91) 2(7.7) 16(6.3) 21(.27) 17(6.69) 19.5(7.5) 152.4(6.) 29.6(.25) 16.1(6.62) 29.6(.25) 16.1(6.62) t 1(.71) 22(.7) 32(1.26) 23.9(.94) 2.5(1.12) 31.(1.25) f * 2 1.6(.6) 1.6(.6) 6.4(.25) n 4 h 19(.75) 23(.91) 23(.91) 19.1(.75) 22.4(.) 22.4(.) *2: In case where process flange material is JIS S25C, value of f is. T16E.EPS
10 1 Model EJ11N Unit: mm (approx. inch) D C X n-h Diaphragm extension length code 2: X2 = 5. mm (2-inch) 4: X2 = 11.6 mm (4-inch) 6: X2 = mm (6-inch) Shrouding bolts (for TIIS flameproof type) LOW Low side 14.3(.52) t 3 (1.1) High side fhigh 12 (4.72) Zero adjustment External indicator conduit connection (Optional) Ground terminal Conduit connection 6 (2.6) 53 ( 2.9) 111 (4.37) 124(4.) 224(.2) 47 (1.5) 125 (4.92) 193 (7.6) 7 (2.76) 112(4.41) 4 17(6.69) (1.9) 97 (3.2) 2-inch pipe mounting bracket (Optional) 2-inch pipe (O. D. 6.5mm) Process flange size: 4-inch (1 mm) Flange Rating ANSI Class 15 ANSI Class 3 D C 21(.72) 175(6.9) 225(.6) 15(7.2) 22.6(9.) 19.5(7.5) 254(1.) 2.2(7.) t 1(.71) 24(.94) 23.9(.94) 31.(1.25) f*1 n 1.6(.6) 1.6(.6) *1: In case where process flange material is JIS S25C, value of f is. h 19(.75) 23(.91) 19.1(.75) 22.4(.) T17E.EPS
11 Model EJ11Y 11 Unit: mm (approx. inch) n-h Shrouding bolts (for TIIS flameproof type) External indicator conduit connection (Optional) Ground terminal 9 *1 (3.54) 6 (2.6) 134(5.2) 225(.6) 31(1.22) t f C D 15 (.59) Low side Conduit connection (4.92) (7.6) 2-inch pipe mounting bracket (Optional) 12 (4.72) 7 (2.76) D C 154.5(6.) 3 (1.1) High side 96.5 (3.7) 53 ( 2.9) 111(4.37) f n-h thigh X (.52) Zero adjustment Diaphragm extension length code 2: X2 = 5. mm (2-inch) 4: X2 = 11.6 mm (4-inch) 6: X2 = mm (6-inch) 112(4.41) 4 17(6.69) (1.9) 97 (3.2) 2-inch pipe (O. D. 6.5mm) 124(4.) 224(.2) 47 (1.5) *1: Indicates inside diameter of gasket contact surface. Low side Process flange size: 3-inch ( mm) Flange Rating D 15(7.2) 2(7.7) C 15(5.91) 16(6.3) t 1(.71) 22(.7) f * 2 n h 19(.75) 23(.91) ANSI Class 15 ANSI Class (7.5) 152.4(6.) 29.6(.25) 16.1(6.62) 23.9(.94) 2.5(1.12) 1.6(.6) 1.6(.6) (.75) 22.4(.) High side Process flange size: 4-inch (1 mm) Flange Rating D C t f * 2 n h ANSI Class 15 ANSI Class 3 21(.72) 175(6.9) 225(.6) 15(7.2) 22.6(9.) 19.5(7.5) 254(1.) 2.2(7.) 1(.71) 24(.94) 23.9(.94) 31.(1.25) 1.6(.6) 1.6(.6) 19(.75) 23(.91) 19.1(.75) 22.4(.) *2: In case where process flange material is JIS S25C, value of f is. T19E.EPS
12 12 Terminal Configuration Terminal Wiring Jumper Note: When external indicator is used, remove this jumper. SUPPLY / BT METER Power supply and output terminal External indicator (ammeter) terminal Ground terminal CHECK METER Connection hook BRAIN TERMINAL Connection hook Note: When using an external indicator, the internal resistance must be 1 or less. T2E.EPS F3.EPS <Ordering Information> Specify the following when ordering 1. Model, suffix codes, and optional codes 2. Calibration range and units: 1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -32 to 32. 2) Specify only one unit from the table, Settings when shipped. 3. Select linear or square root for output mode and display mode. (Note) If not specified, the instrument is shipped set for linear mode. 4. Select normal or reverse for operation mode (Note) If not specified, the instrument is shipped in normal operation mode. 5. Display scale and units (for transmitters equipped with integral indicator only) Specify either to 1 % or engineering unit scale and Range and Unit for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of to Tag Number. (if required) 7. Process fluid temperature for zero compensation (if required) <Related Instruments> Power Distributor: Refer to GS 1B4T1-2E or GS 1B4T2-2E BRAIN TERMINAL: Refer to GS 1CA11-E <Reference> 1. JIS SUS316L stainless steel; Equivalent to AISI 316L. 2. JIS SUS316 stainless steel; Equivalent to AISI JIS SUS34 stainless steel; Equivalent to AISI JIS S25C carbon steel; Equivalent to AISI Teflon; Trademark of E.I. DuPont de Nemours & Company (USA) for polytetrafluoroethylene. 6. JIS SCM435 chrome molybdenum steel; Equivalent to AISI JIS SUS63 stainless steel; Equivalent to ASTM 63.. Hastelloy C-276; Trademark of Union Carbide Corporation (USA) for nickel-molybdenum alloy. 9. Other company names and product names used in this material are registered trademarks or trademarks of their respective owners. Subject to change without notice.
General Specifications
General Specifications Model EJB430 Gauge Pressure Transmitter GS 01C23E01-00E [Style: S2] The model EJB430 Gauge Pressure Transmitter can be used to measure liquid, gas, or steam pressure. It outputs
More informationGeneral Specifications
General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the differential
More informationGeneral Specifications
General Specifications GS 01C31J03-01EN EJA438E Diaphragm Sealed Gauge Pressure Transmitter Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly of the transmitter,
More informationGeneral Specifications
General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the differential
More informationGeneral Specifications
General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the
More informationGeneral Specifications
General Specifications EJA210E Flange Mounted Differential Pressure Transmitter The high performance flange mounted differential pressure transmitter EJA210E can be used to measure levels of densities
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based smart transmitter
More informationGeneral Specifications
General Specifications EJX210A Flange Mounted Differential Pressure Transmitter [Style: S2] The high performance flange mounted differential pressure transmitter EJX210A can be used to measure levels of
More informationGeneral Specifications
General Specifications Models RM and RH Resistance Temperature Sensor GS 06B03B01-00E GENERAL Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in
More informationGeneral Specifications
General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in
More informationEDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code
Intelligent Absolute Pressure Transmitter Absolute Pressure Transmitter incorporates semiconductor sensors and a microcomputer and converts measured s to 4 to 20mA DC signal with high accuracy. is suitable
More informationC S. Sanitary Differential Pressure Transmitter with Diaphragm Displacement Device CS Range Code. Accuracy. Note 1)
C S CODE AND SPECIFICATIONS SHEET Sanitary Differential Pressure Transmitter with Diaphragm Displacement Device EDR-N7SD is intelligent transmitter equipped with semiconductor sensers and micro processors.
More informationSmart Pressure Transmitter
DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationMonocrystalline silicon smart differential pressure transmitter. High stability, Diaphragm sealed. Benefits. Application
Monocrystalline silicon smart differential pressure transmitter DRS380 High stability, Diaphragm sealed Detailed Information www.dersensor.com Application the flow of gas, vapor and liquid measurement
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationSmart Pressure Transmitter
DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More informationUser's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter
User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity
More informationUser s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition
User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement
More informationSPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)
Specifications 571T, 572T Electronic Differential Pressure Transmitter with Sanitary/ Aseptic Remote Seal Elements ±0.2% of span accuracy Spans from 25 to 800 inches H2O Outstanding temperature stability
More informationC S. Differential Pressure Transmitter CS Range Code. Accuracy
C S CODE AND SPECIFICATIONS SHEET Differential Pressure Transmitter EDR-N7P is intelligent transmitter equipped with semiconductor sensers and micro processors. EDR-N7P Range Measuring Code Span Settable
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More information2010TC for Differential Pressure, Pressure and Temperature (Mass Flow)
Technical data 2 Principle of Operation and Construction The transmitter has a modular design and consists of the differential pressure sensor module with an integrated electronic matching unit, an amplifier
More informationSATRON VT Pressure Transmitter
SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring
More informationSmart Pressure Transmitter
DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationPRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER
PRESSURE PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE The PYRP-28 pressure transmitter is suitable for the measurement of pressure, vacuum and absolute pressure of gases, vapours and liquids for industrial
More informationJUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")
Page 1/15 JUMO dtrans p20 Process pressure transmitter Brief description The device with the HART interface combines maximum precision with simple operation. It is used to measure the system pressure of
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process
More informationUNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
More informationINTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter
INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers
More informationUser s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)
User s Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals by electronic
More informationModel 1151 Alphaline Pressure Transmitters
Alphaline Pressure Transmitters FEATURES A complete family of transmitters Ranges from 0 0.5 inh 2 0 to 6,000 psig (1.24 kpa to 41370 kpa) Solid-state, plug-in circuit boards Compact, rugged construction
More information2600T Series Pressure Transmitter
Data Sheet 2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute standard overload Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi 0.3 to 3000kPa abs; 2.25mmHg
More informationST3000 Ace Smart Transmitter Sanitary Differential Pressure / Pressure Transmitters
ST3000 Ace Smart Transmitter Sanitary Differential Pressure / Pressure Transmitters Model JTC929A/JTC940A, JTE929A/JTE930A OVERVIEW The Food and beverage industry and fermentation industry require equipment
More informationJUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb
sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure
More informationMagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus
MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven
More informationRosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:
Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference
More informationDL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless
More informationUNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features
GE Sensing & Inspection Technologies UNIK 5000 Pressure Sensing Platform The UNIK 5000 is a high performance configurable solution to pressure measurement. The use of Druck silicon technology and analogue
More informationSmart Valve Positioner 700 Series with HART Communication Protocol
No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core
More informationSmart Valve Positioner 700 Series with HART Communication Protocol
No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core
More information압력트랜스미터 Model ADP9000 Series
ALIA PRODUCT 압력트랜스미터 Model ADP9000 Series GEERAL ADP9000 series is a digital differential pressure transmitter designed for industrial pressure measurement applications. The ADP9000 offer Configurations
More informationSATRON VVFe Pressure Transmitter
SATRON VVFe pressure transmitter belongs to Vtransmitter family. SATRON VVFe is used for 0 4 kpa...0500 kpa ranges. It is a 2wire transmitter with HART standard communication. SATRON VVFe pressure transmitter
More informationDifferential Pressure Gauges (701P Series)
Applications Equipped two Process Connections Indicating low and high pressure Measuring differential pressure as well as liquid or flow levels Recommended to use 3-way & 5-way valve manifold Pressure
More informationPressure transmitter PASCAL CV4
Pressure transmitter PASCAL CV4 with threaded connection, Type series CV4100 Features Application area Pharmaceutical industry Food industry Biotechnology General process technology Compact case of stainless
More informationRosemount 3051S Electronic Remote Sensor (ERS) System
Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure
More informationModel Y/13FA, Y/13FEA and Y/15FA Pneumatic Flange Mounting Differential Pressure Transmitters
User s Manual Model Y/13FA, Y/13FEA and Y/15FA Pneumatic Flange Mounting Differential Pressure Transmitters 5th Edition Model Y/13FA, Y/13FEA and Y/15FA Pneumatic Flange Mounting Differential Pressure
More informationProduct Data Sheet , Rev GA Catalog Content
HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line sizes Reduces leak
More informationRosemount 3152N Nuclear Qualified Pressure Transmitter
Product Data Sheet Rosemount 3152N Nuclear Qualified Pressure Transmitter Rosemount 3152N INDUSTRY LEADING PERFORMANCE Qualified per: o IEEE Std 323-1974/1983/2003 o IEEE Std 344-1975/1987/2004 6.5 Mrad
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for general application, Type Series CI4300 Features Differential pressure transmitter with metallic diaphragm High-resolution graphic display with
More informationGeneral Specifications
General Specifications DO0G Sensor for Dissolved Oxygen Analyzer GS 2J05D0-0E GENERA The DO0G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent
More information2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device
2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering
More informationSITRANS P measuring instruments for pressure
Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)
More informationModel 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)
Data Sheet DS/266HSH/LowP-EN Rev. B Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART) Engineered solutions for all applications Measurement made easy Base accuracy 0.15
More informationM3500 Industrial Pressure Transmitter
M3500 Industrial Pressure Transmitter The M3500 is a high accuracy industrial pressure transmitter featuring HART communications and a cast aluminum enclosure for indoor or outdoor use. Typical output
More informationTemperature Indicating Controller
\ KF Series Temperature Indicating Controller Model KFT OVERVIEW The KF Series instruments are field-installed type of pneumatic indicating controllers which are used to measure and control the various
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationSafir-M digital. Features. LCD indicator and controls. Industries. Applications
Features Reference accuracy, % FS 0.1 0.15 0.25 0.5 (draft pressure) Turndown 1:25 Output 4 20 ma, 0 5 ma Linear (increasing or decreasing) Square root (differential pressure) Damping (optional), s 0.5
More informationGeneral Specifications
General Specifications DO30G Sensor for Dissolved Oxygen Analyzer GS 2J05D03-0E GENERA The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works,
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationSmart Displacement type Level Transmitter
No. SS-SLX100-0100 Smart Displacement type Level Transmitter model SLX OVERVIEW The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters
More informationPiezoresistive single crystal silicon pressure transmitter
Product introduction Description Piezoresistive single crystal silicon pressure transmitter 305PI TSD single crystal silicon pressure transmitter is a high performance pressure transmitter with international
More informationL D FB DEVICES FIELDBUS PRESSURE TRANSMITTERS. Features 0 ~125 Pa to 0 ~ 40 MPa. (0 ~0.5 inh 2
L D 3 0 2 FIELDBUS PRESSURE TRANSMITTERS FB DEVICES Features 0 ~125 Pa to 0 ~ 40 MPa. (0 ~0.5 inh 2 0 to 0 ~ 500 psi). 0.075% accuracy of the calibrated range. Accepts calibration from URL to URL/120.
More informationSATRON VTe pressure transmitter
SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in
More informationUIB3351 Metal Capacitive Pressure/Differential Pressure Transmitters
UIB3351 Metal Capacitive Pressure/Differential Pressure Transmitters 1. Description UIB3351 series intelligent pressure transmitters are suitable for the measurement of flow, level and pressure (differential
More informationMETAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER
TECHNICAL INFORMATION METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER Electronic Transmitter INTRODUCING THE METAL TUBE VAREA-METER U.S. Filter/Wallace & Tiernan Products straight through metal tube
More informationMasoneilan Series
Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle
More informationRosemount 1151 Pressure Transmitter
Product Data Sheet Rosemount 1151 Rosemount 1151 Pressure Transmitter Proven field performance and reliability Commitment to continuous improvement Reference accuracy of 0.075% Two-year stability of 0.1%
More informationElectric Top-Guided Single-Seated Control Valves
No. SS2-AGV200-0300 CV3000 Alphaplus series Electric Top-Guided Single-Seated Control Valves Model AGVB / AGVM OVERVIEW The CV3000 Alphaplus range of top-guided single-seat control valves features a compact
More informationRemote-sealed type of Differential Pressure Transmitters
AT9000 Advanced Transmitter Remote-sealed type of ifferential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for high static working pressure, PN 160, Type series CI4340 Features Simultaneous display of differential pressure and static pressure Long-term stability
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationFIELD DEVICES - PRESSURE
FIELD DEVICES - PRESSURE Product Specifications Logo Models IAP10, IGP10, IAP20, and IGP20 I/A Series Electronic Absolute and Gauge Pressure Transmitters with 4 to 20 ma Analog Output PSS 2A-1C13 C IAP20/IGP20
More informationRosemount 3152K Nuclear Qualified Pressure Transmitter
Nuclear Qualified Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per KTA 3505 Mild Environment Qualifications 50 kgy (5 Mrad) TID Gamma Radiation Vibration to 5g seismic and 8g APC LOCA/HELB
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationGeneral Specifications
General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order
More informationTEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE
Technology Solutions TEK-B AR 3110A Differential Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar 3110A Differential
More informationCV3000 Series Low-Noise Cage type Control Valve Model ACN
No. SS2-ACN110-0100 CV3000 Series Low-Noise Cage type Control Valve Model ACN OVERVIEW The model ACN low-noise cage type control valves are designed to reduce acoustic noise in services of compressible
More informationUser s Manual Model EJA110A, EJA120A and EJA130A Differential Pressure Transmitters
User s Manual Model EJA110A, EJA120A and EJA130A Differential Pressure Transmitters 12th Edition i Model EJA110A, EJA120A and EJA130A Differential Pressure Transmitters Contents 12th Edition 1. Introduction...
More informationIGP10, IGP20 Intelligent Gauge Pressure Transmitters IAP10 Intelligent Absolute Pressure Transmitter
, Intelligent Gauge Pressure Transmitters Intelligent Absolute Pressure Transmitter 1 for compact light weight and direct-to-process mounting (bracket optionally available), bracket mounted, for lower
More informationABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet
Specification sheet 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use Ranges : - 100 to 4000 kpa - 1 to 40 bar - 14.5 to 600 psi Base accuracy : 0.2%(BFSL) Piezoresistive
More informationCV3000 Series Pressure-Balanced Cage type Control Valve
No. SS2-ACP110-0100 OVERVIEW The model ACP pressure-balanced cage type control valves are designed for heavy duty service. The valve plug employs a pressure balance function to control high differential
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts
More informationRosemount DP Level Transmitters and 1199 Remote Seals
Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationCeramic Trim Angle Control Valves
No. SS2-8113-2610 Ceramic Trim Angle Control Valves Model HAF OVERVIEW Model HAF ceramic trim angle control valves provide the valve plug and sheet ring employing high performance ceramic with excellent
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationSmart Electromagnetic Flowmeter Detector for Sanitary use
MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable
More informationRosemount 3051S Series of Instrumentation
Product Data Sheet 3051S Series delivers highest field performance and reliability SuperModule Platform provides a foundation for integrated pressure, flow, and level solutions IEC 62591 (WirelessHART
More informationSeries 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability
Series 60 New Smart Positioner Compact design Convenient & powerful function Enhanced reliability J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com
More informationThree Way Control Valves
No. SS2-HDT110-0100 Three Way Control Valves Model HDT OVERVIEW The valve model HDT is a three-way control valve for diverting service. It has a small-sized, high-output diaphragm motor which is suitable
More informationModel 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute. Series 2600T Pressure Transmitters. Engineered solutions for all applications
Contents Data Sheet SS/261GC/AC-EN Rev. 05 Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute Series 2600T Pressure Transmitters Engineered solutions for all applications With direct mount
More informationModel FVP General Specification. Flanged Vortex Plate. Product Features
Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from
More informationUNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F
UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature
More informationRosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications
Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More information