Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Size: px
Start display at page:

Download "Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K"

Transcription

1 DUSA Pharmaceuticals, Inc. Table of Contents Go to Chart # Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K BLU-U Features: 10K BLU-U Features 10K BLU-U Symptom Fans Running, Timer Decrementing, Lamps NOT Operating (All 4170 Systems) 1 Timer Decrementing, Lamps & Fans NOT Operating (1K 6K Units) 2 te: For Timer 2 go to Chart 6 First (Serial # is 7026 or greater) Timer Decrementing, Lamps & Fans NOT Operating (10K Units) 3 Power 4 Timer 1 Error Conditions (1K, 3K or 6K Serial # is 7025 or less) F001, F101 (3x F001, High Voltage) -or- F002, F202 (3x F002, Low 5 Voltage) Displayed on Timer F303 Displayed on Timer 7 Timer 1: Codes to Clear F101/F202 Errors Timer 2 Error Conditions (6K Serial # is 7026 or greater & 10K Units) Lamps and Fans NOT Operating, Timer Decrementing -OR- 6 Timer Illuminated but NOT Functioning ERR Displayed on Timer 7 Status Indicator Light Conditions (All 4170 Systems) Flashing Rapidly, Lamps NOT Lit 8 Flashing Slowly, Lamps are Lit 9 On Steady, or Intermittent, Lamps are Lit 10 Does t Flash 3 Times at Cycle Start 11 Two or Three Lamps do NOT Light or are Dimmer than the Rest (All 4170 Systems) 12 Hard to Move Post Arm Up and Down (1K 6K Units) 13 Checking Lamp Connectors (All 4170 Systems) 14 Replacing F2 Fuse in Head (All 4170 Systems) 15 Frequently Asked Questions (All 4170 Systems) 16 te: This manual to be used in conjunction with FORM281 BLU-U Field Replacement Matrix and SOP2-016 Customer Service Process Table of Contents

2 DUSA Pharmaceuticals, Inc. Timer Identification Timer 1 ID: Colored Keys ( UP, DN, Start/Stop ) P/N: 1TM-035D Timer 2 ID: Black & White Keys ( UP, DN, Start/Stop ) (Serial # is DPCE7026 or greater) P/N: SCD-1477 BLU-U Timer Troubleshooting Root Cause Timer 1 Go to... Timer 2 Go to... Post Anderson s Miswired or Disconnected Base Fuse Orientation F001/F101 Displayed on Timer F002/F202 Displayed on Timer Chart 5 Lamps & Fans NOT Operating, Timer Chart 6 Illuminated but NOT Chart 5 Functional OR Timer Decrementing Chart 6 Timer Watchdog Clock out of Sync F303 Displayed on Timer Chart 7 ERR Displayed on Timer Chart 7 Timer ID

3 DUSA Pharmaceuticals, Inc. BLU-U Features 1K 6K Remove (4) screws and top cover of head to check terminal block wiring (see Chart 12) and change F2 fuse (see Chart 15). Serial number label on top of head. Post Anderson connectors located in oval slot on bottom of left side post arm. Post knob and pin. Remove (1) screw from upper timer housing & slide timer housing 1"-2" up post to check timer connectors. Remove (4) screws and (2) head end caps to check lamp connectors. See Chart 14 Power Inlet Module on back of base, see Fig. 1 Serial number label on bottom of post & back side of base. Caster adapter (outrigger style) located on right rear of base See FORM310 for old style casters. Country rth America Europe Voltage Indicator 115V 230V To reverse fuse module: Open cover, Remove red block, Rotate 180, Replace red block. Figure 1 (All 4170 Systems) BLU-U Features 1K 6K

4 DUSA Pharmaceuticals, Inc. BLU-U Features 10K Serial number label on top of head. Brake handle to lock head position: Clockwise = Lock Counter-Clockwise = Unlock Remove (4) screws and top cover of head to check terminal block wiring (see Chart 12) and change F2 fuse (see Chart 15). Remove (1) screw from bottom timer housing & rotate timer housing out and down to check timer fuse. Lift Pivot Latch & rotate post 90 clockwise to place post in storage mode Power Inlet Module on back of base, see Fig. 1 Serial number label on bottom of post & back side of base. Remove (4) screws and (2) head end caps to check lamp connectors. See Chart 14 Country rth America Europe Voltage Indicator 115V 230V Closed Position To reverse fuse module: Open cover, Remove red block, Rotate 180, Replace red block. Figure 1 (All 4170 Systems) BLU-U Features 10 K

5 DUSA Pharmaceuticals, Inc. Symptom: Fans Running, Timer Decrementing, Lamps NOT Operating (All 4170 Systems) Remove back cover of Head with a Phillips Screwdriver (#2). Locate F2 fuse on bottom left hand side of PCB (printed circuit board) when standing behind BLU-U. Is F2 Fuse blown? Change the F2 fuse, see Chart 15 for instructions. (Customer: See MAN-1212 in fuse kit for Proper Fuse & Instructions) Install back cover of head. (May leave screws off until unit tested) Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps turn on)? Tip: If head lights flickered then went out after replacing F2 fuse; the fuse may have blown again. Ship more fuses to customer, if required, and replace fuse again prior to replacing the head. Troubleshooting Complete Reconnect head screws F2 Fuse (Fig. 1 below) Remove back cover of head. Locate Green Terminal Blocks (6 pin & 7 Pin) on bottom left hand side of PCB (printed circuit board) when standing behind BLU-U. Check that wires are secure & tighten screws if loose. Install back cover of head. (May leave screws off until unit tested) Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps turn on)? Troubleshooting Complete Reconnect head screws HEAD needs repair. HEAD. 7 Pin Terminal Block 6 Pin Terminal Block Figure 1 Chart 1

6 DUSA Pharmaceuticals, Inc. Symptom: Timer Decrementing, Lamps & Fans NOT Operating (1K 6K Units) Locate Anderson connectors in post. (In oval slot on bottom of post yoke) Remove Anderson connectors from slot. Are Anderson connectors securely connected? (See Figure 1: May need to remove black tape) Post Anderson Wiring Chart 6K Units 1K & 3K Units Grn/Yel Black Green Green Black #1 Red Black #1 Black #1 Black #2 Orange Black #2 Black #2 Black #3 Brown Black #3 Black #3 Reconnect Anderson connectors. (See wiring table) Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps & fans turn on)? (see Fig. 1 on Chart 1) Remove screws from head cover and remove head cover. Locate Green Terminal Blocks (6 pin & 7 Pin) on bottom left hand side of PCB (printed circuit board) when standing behind BLU-U. Check that wiring is secure & tighten screws if loose. Ensure terminal block is securely seated on PCB (push down on terminal block) Locate F2 fuse on bottom left hand side of PCB when standing behind BLU-U. Change the F2 fuse, see Chart 15 for instructions. (Customer: See MAN-1212 in fuse kit for proper fuse & instructions) Install back cover of head. (May leave screws off until unit tested) Reconnect power and turn BLU-U on. Troubleshooting Complete Troubleshooting Complete Reconnect head screws Is the BLU-U functioning (lamps & fans turn on)?, Unit is a 6K Figure 1 Post Anderson Connectors HEAD needs repair. HEAD., Unit is A 1K 3K Perform this step ONLY if troubleshooting with a field technician. Tools required: multimeter Check for 120 Volt power coming from post. Measure power from post Andersons connected to Black #2 and Black #3 wires. If no power, POST needs repair, send replacement POST. If there is power, HEAD needs repair, send replacement HEAD. Perform this step ONLY if troubleshooting with a field technician. Tools required: multimeter Check for 120 Volt power coming from post. Measure power from post Andersons connected to Black #2 and Black #3 wires. If no power, POST needs repair, send replacement POST. If power is 120 V reconnect Anderson connectors using wiring chart. Check for 120 V power on Pin 2 and Pin 3 of circular metal connector on end of post cable. If there is no power, the ADAPTER CABLE is faulty, send replacement ADAPTER CABLE. If there is power, the HEAD needs repair, send replacement HEAD. Chart 2

7 DUSA Pharmaceuticals, Inc. Symptom: Timer Decrementing, Lamps & Fans NOT Operating (10K Units) Turn timer key off. Disconnect circular metal connector from head. Turn timer key on and press Start/Stop button. Check power on Pin 2 and Pin 3 of circular metal connector on end of post cable. Is voltage 120 V? Disconnect the head from the stand arm, carefully remove the head and set the head aside. Remove (2) screws securing yoke to post. Disassemble yoke from post (feed head cable into yoke to aid disassembly). Check that 6 pin connector is securely fastened. Reconnect 6 pin connector if required. Reassemble yoke to post (gently pull head cable out of yoke to aid in assembly). Replace (2) screws securing yoke to post. Replace head on yoke & reconnect circular head connector. Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps & fans turn on)? Turn Timer off with key. (see Fig. 1 on Chart 1) Remove screws from head cover and remove head cover. Locate Green Terminal Blocks (6 pin & 7 Pin) on bottom left hand side of PCB (printed circuit board) when standing behind BLU-U. Check that wiring is secure & tighten screws if loose. Ensure terminal block is securely seated on PCB (push down on terminal block) Locate F2 fuse on bottom left hand side of PCB (printed circuit board) when standing behind BLU-U. Change the F2 fuse, see Chart 15 for instructions. (Customer: See MAN-1212 in fuse kit for Proper Fuse & Instructions) Install back cover of head. (May leave screws off until unit tested) Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps & fans turn on)? POST needs repair. POST. HEAD needs repair. HEAD. Troubleshooting Complete Troubleshooting Complete Chart 3

8 DUSA Pharmaceuticals, Inc. Symptom: Power (All 4170 Systems) If possible, check the wall outlet for 120VAC (either with voltmeter or other equipment such as a desk lamp). Did outlet work? problem found with BLU-U. Possible problems with facility power. Check the following: o Is the BLU-U plugged into the wall outlet? If no, plug it in o Is the Power Inlet Module Switch turned on? If no, turn it on to I o Is the Key Switch turned on? If no, turn key on... Is the timer Illuminated? If yes...push Start/Stop button Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? Remove fuse holder from Power Inlet Module and check fuses (flat bladed screw driver may be needed to remove). Troubleshooting Complete Are the fuses good? Replace both of the fuses and verify proper orientation of the fuse holder for 115V or 230V. (see Fig. 1) Turn Power on at base and turn key on. Verify proper orientation of the fuse holder for 115V or 230V. (see Fig. 1) Turn Power on at base and turn key on. Country rth America Europe Voltage Indicator 115V 230V Is the timer Illuminated? If yes...push Start/Stop button Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? End of Troubleshooting with customer. Turn over to DUSA Tech Support for Further Troubleshooting. If Service Technician on site Continue Troubleshooting at top of Chart 4 Part B for 1K-6K; & Chart 4 part C for 10K. To reverse fuse module: Open cover, Remove red block, Rotate 180, Replace red block. Figure 1 (All 4170 Systems) Chart 4 Part A

9 DUSA Pharmaceuticals, Inc. Power: Continued from Chart 4 Part A; 1K 6K Units Only Perform this step ONLY if troubleshooting with a Field Technician. Disconnect the head from the stand arm, carefully remove the head and set the head aside. Place the unit on it s side with the yoke/arm facing up and remove the dust cover from the base. Inspect resistor connectors for signs of arcing and give slight crimp if loose. Is Base/Post Anderson Connector connected? Connect the Base/Post Anderson Connector. Plug in the unit, Turn on base power inlet module Turn on the timer key. Is timer illuminated? Disconnect the Anderson Connector. Turn the power back on and measure AC voltage at Base connector side (Black wire to Black wire) Does voltage measure approx. 120VAC? Connect head to post. Press Start/Stop button on timer to start cycle. Troubleshooting Complete (reassemble unit) BASE needs repair. BASE. Is the BLU-U functioning (lamps & fans turn on)? Go to Chart 1 to check and replace F2 fuse in head Reconnect Anderson Connectors. Remove top screw from timer housing and open carefully. Replace the Timer fuse (250V 313, 1-¼ Amp) Is Timer fuse blown? (Fuse located on back of timer) Check for loose connectors inside the Timer. Reconnect power and test unit. Reconnect the timer housing. Reconnect power and test unit. Did it fix the problem? POST needs repair. POST. Did it fix the problem? Troubleshooting Complete (reassemble unit) POST needs repair. POST. Chart 4 Part B

10 DUSA Pharmaceuticals, Inc. Power: Continued from Chart 4 Part A; 10K Units Only Remove screw from bottom of timer housing. Rotate timer housing out and then down to remove timer housing from post. Perform this step ONLY if troubleshooting with a Field Technician. Is Timer fuse blown? (Fuse located on back of timer) Replace the Timer fuse (250V 313, 1-¼ Amp) Check for loose connectors inside the Timer. Reconnect the 6 pin electrical connector & timer housing. Reconnect power and test unit. Open timer housing. Check for loose connections inside timer. Disconnect 6 pin electrical connector. Measure voltage at Pin 1 and 2 of 6 Pin connector located inside post. Is voltage 120 V? TIMER needs repair. TIMER. Disconnect the head from the yoke, carefully remove the head and set the head aside. Loosen (1) screw at bottom of post. Disassemble post from base. Check that 6 pin connector is securely fastened. Reconnect 6 pin connector if required. Reassemble post to base. Tighten (1) screw at bottom of post. Replace head on yoke & reconnect circular head connector. Reconnect power and turn BLU-U on. Did it fix the problem? Is timer illuminated? Is the timer illuminated? Troubleshooting Complete (reassemble unit) Are fans running and lamps NOT illuminated? Replace F2 fuse in head; check wiring & terminal block in head. Go to Chart 1. BASE needs repair. BASE. Check power on Pin 2 and Pin 3 of circular metal connector on end of post cable. Is voltage 120 V? Check wiring & terminal block in head. Go to Chart 1. Troubleshooting Complete Disconnect the head from the stand arm, carefully remove the head and set the head aside. Remove (2) screws securing yoke to post. Disassemble yoke from post (feed head cable into yoke to aid disassembly). Check that 6 pin connector is securely fastened. Reconnect 6 pin connector if required. Reassemble yoke to post (gently pull head cable out of yoke to aid in assembly). Replace (2) screws securing yoke to post. Replace head on yoke & reconnect circular head connector. Reconnect power and turn BLU-U on. Is the BLU-U functioning (lamps & fans turn on)? POST needs repair. POST. Troubleshooting Complete Chart 4 Part C

11 DUSA Pharmaceuticals, Inc. Symptom: Timer 1: F001/F101 (3x F001, Post Andersons) Error Code Displayed on Timer F002/F202 (3x F002, Power Inlet Module Orientation) Error Code Displayed on Timer -OR- F002/F202 Error Fuse Module Check Power Inlet Module on Base. Verify proper orientation of the fuse holder for 115V (or 230V). Is power inlet module oriented with 115V (or 230V) visible? Unplug power cord from base. Remove Fuse Block from power inlet module and orient correctly (See Fig. 1 on Chart 6, may require the use of a flat bladed screw driver) F001/F101 Error Post Andersons Are Anderson Connectors in post yoke properly connected? (See Fig. 2 on Chart 6, may need to remove black tape) Unplug power cord from base. Reconnect Anderson Connectors (see wiring table above). Post Anderson Wiring Chart 6K Units Grn/Yel Black Black #1 Red Black #2 Orange Black #3 Brown 1K & 3K Units Green Black #1 Black #2 Black #3 Green Black #1 Black #2 Black #3 Plug unit back into wall outlet. Turn on power switch on Base. Press Start/Stop button on Timer. Does timer display 0:00? Set timer for 16:40 Press Start/Stop button Four digit Patient Code is displayed on timer. Find the displayed code in Chart under Displayed on Timer column (or in SOP2-030 under Patient Code Number column). Is the BLU-U functioning (lamps & fans turn on, timer decrementing)?. Repeat up to 3 times. If code does not clear, check Post Anderson connectors. Find code to clear timer on Chart in Code to Clear Timer column (or in SOP2-030 in 75 Treatments column). Hold UP or DOWN button on Timer until password is displayed. Press Start/Stop button. Troubleshooting Complete Does timer display 0:00? Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? Set timer for 16:40 Press Start/Stop button Turn over to technical support for further troubleshooting with field technician. Check power through post cables per Chart 2. Chart 5

12 DUSA Pharmaceuticals, Inc. Symptom: Timer 2: Lamps & Fans NOT Operating, Timer Decrementing -OR- Timer Illuminated but NOT Functional (All 4170 Systems) Check Base Fuses Check Power Inlet Module on Base. Verify proper orientation of the fuse holder for 115V (or 230V). (6K Units Only) Check Anderson Connectors in Post Yoke Are Anderson connectors properly connected? (See Fig. 2, may need to remove black tape) Post Anderson Wiring Chart Grn/Yel Black #1 Black #2 Black #3 6K Units Black Red Orange Brown Is power inlet module oriented with 115V (or 230V) visible? Unplug power cord from base. Remove Fuse Block from power inlet module and orient correctly (See Fig. 1, may require the use of a flat bladed screw driver) Unplug power cord from base. Reconnect Anderson Connectors in Stand Arm (see wiring table above). Plug unit back into wall outlet. Turn on power switch on Base. Press Start/Stop button on Timer. Does timer display 0:00? Set timer for 16:40 Press Start/Stop button Turn over to technical support for further troubleshooting with field technician. Check timer fuse, see Chart 4 Part B for 1K-6K; & Chart 4 Part C for 10K. Is the timer decrementing? Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? Country rth America Europe Voltage Indicator 115V 230V Troubleshooting Complete Turn over to technical support for further troubleshooting with field technician. Check wiring in head and change F2 fuse, see Chart 1 To reverse fuse module: Open cover, Remove red block, Rotate 180, Replace red block. Figure 1 (All 4170 Systems) Anderson Connectors in Post Yoke Figure 2 (6K Units Only) Chart 6

13 DUSA Pharmaceuticals, Inc. Symptom: F303 or Err Displayed on Timer Timer 1: F303 Displayed on Timer Timer 2: ERR Displayed on Timer Timer clocks are out of Sync Timer clocks are out of Sync POST needs repair. Post. TIMER needs repair. Timer. Chart 7

14 DUSA Pharmaceuticals, Inc. Symptom: Status Indicator Light Flashing Rapidly, Lamps NOT Lit (All 4170 Systems) Lamp Control Circuit Defective HEAD needs repair. HEAD. Chart 8

15 DUSA Pharmaceuticals, Inc. Symptom: Status Indicator Light Flashing Slowly, Lamps Are Lit (All 4170 Systems) Perform this step ONLY if troubleshooting with a Field Technician Measure AC voltage at wall outlet with voltmeter, 1K systems Is AC Voltage higher than 122VAC? Disconnect the head from the stand-post arm and carefully remove the head and set the head aside. Place the stand-post on it s side with the yoke/arm facing up. Remove the dust cover from the base. Ensure power resistor has been installed., 3K, 6K, and 10K systems Lamp control circuit needs repair HEAD Needs repair. HEAD. Resistor installed? Inspect resistor connectors for signs of arcing and give slight crimp if loose. problem found with BLU-U. Possible problems with facility power. Reassemble system. Install Resistor Kit. Reassemble Base. Plug back into wall outlet, turn on power switch on base. Turn timer key on. Press Start/Stop button. If resistor arced, send replacement RESISTOR KIT Is the BLU-U functioning (lamps & fans turn on, timer decrementing)?, but SSI continues to flash Troubleshooting Complete Chart 9

16 DUSA Pharmaceuticals, Inc. Symptom: Status Indicator Light On Steady, or Intermittent, Lamps Are Lit (All 4170 Systems) Check number of hours on Timer 1 Timer 1: Determine the number of hours on the unit as follows: Hold the start/stop button down, turn the key on, while still holding the start/stop button, the timer will display NBC and then the hours h000. (i.e., h003, will indicate 3 hours). Timer 2: Can not check number of hours on the unit. 6K units: Are hours 445 or greater? See table below for 1K and 3K units. Measure AC voltage at wall outlet with voltmeter Replace the HEAD. Head has reached Max # of treatments. AC Voltage less than 111VAC? Lamp control circuit needs repair. problem found with BLU-U. Possible problems with facility power. HEAD needs repair. Send replacement HEAD. 1K Series = Serial # DH thru DH K Series = Serial # DHCE3000 thru DHCE5999 6K Series = Serial # DHCE6000 and above 10K Series = Serial # DHCE10100 and above Maximum Number of Cycles for 1K and 3K Heads Only: If the S/N does not have a -10 or -16 suffix, assume 500 cycles (139 hours) If the S/N has -10 suffix, maximum cycles is 1050 (306 hours) If the S/N has a -16 suffix, maximum cycles is 1600 (445 hours) Maximum Number of Cycles for 6K & 10K = 1600 (445 hours) Number of Hours x 3.6 = Number of Cycles Replace Head when maximum number of cycles is reached. Chart 10

17 DUSA Pharmaceuticals, Inc. Symptom: System Status Indicator (SSI) Light Does NOT Flash 3 Times at Cycle Start (All 4170 Systems) Turn on timer with key. Press Start/Stop button. Does SSI flash 3X at power up? problem found with BLU-U. Let run for at least 3 mins. and observe lamps (ensure Blue light blocking goggles are used) Does light output step up or down? Unit is unsafe to use. HEAD needs repair. Send replacement HEAD. Unit is safe to operate to complete currently treated patients. (SSI bulb is broken) 1K 6K Units 10K Units Post needs repair but is safe to use. Replace post when possible. SSI needs repair but is safe to use. Replace TIMER ASSEMBLY when possible. Chart 11

18 DUSA Pharmaceuticals, Inc. Symptom: Two or Three Lamps do NOT Light or are Dimmer than the Rest (All 4170 Systems) Remove 4 screws from Head cover, see Figure 1. Examine connector TB2 (6 pin terminal block) on circuit board, see Figure 2. Push in connector securely and tighten all wires as necessary. Replace head cover. Reconnect power and test unit. Is it pushed in securely and are all the wires tightened? Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? Check lamp connectors per Chart 14 HEAD needs repair. Send replacement HEAD. Reassemble system Is the BLU-U functioning (lamps & fans turn on, timer decrementing)? TB2 6-pin terminal block Troubleshooting Complete Figure 1 Figure 2 Chart 12

19 DUSA Pharmaceuticals, Inc. Symptom: Hard to Move Post Arm Up and Down (1K 6K Units Only) Unscrew post knob. Using a pair of pliers remove the nylon pin. Using the pliers squeeze the v-notch back to the normal size of the pin. Replace pin and post knob. Do not over tighten the knob. Field Technician Support Did it fix the problem? Disconnect the head from the stand-post arm and carefully remove the head and set the head aside. Place the stand-post on it s side with the yoke/arm facing up and remove the dust cover from the base. Troubleshooting Complete Ensure service loop is not hung up on any items located in the base. Ensure cable is not bound/kinked inside post. Ensure cable tensioner, if present, is securely attached to baffle and is functioning properly. Reassemble unit. Raise & lower post. Did it fix the problem? POST needs repair. Send replacement POST. Chart 13

20 DUSA Pharmaceuticals, Inc. Checking Lamp Connectors (All 4170 Systems) Tool Required: Phillips Head Screwdriver (#2) Remove screws from Endcaps. Remove (4) screws from Endcaps on BLU-U Head, see Figure 1. Remove Endcaps and Foam Filter from BLU-U Head, see Figure 1. Remove Endcaps and Foam Filter Figure 1 Ensure all (14) lamp connectors are firmly seated on lamp ends. Reseat loose connectors as required, see Figure 2. Check all lamp connectors on both ends of lamps. Reseat loose connectors. Figure 2 Re-install endcaps with foam filter on BLU-U head. Securely fasten with (4) screws, see Figure 1. Plug BLU-U into wall outlet and turn on timer key. Press Start/Stop button on timer. Verify all lamps are illuminated. Chart 14

21 DUSA Pharmaceuticals, Inc. Replacing F2 Fuse in Head (All 4170 Systems) Tool Required: Phillips Head Screwdriver (#2) Remove (4) screws from head cover (see Figure 1). Remove head cover and set aside. Locate Circuit Board and F2 fuse near green terminal block (see Figure 2). Remove the existing F2 fuse. Install new F2 fuse into same location taking care not to touch any other component on the board. Re-install head cover (may leave screws out for testing). Plug BLU-U into wall outlet. Turn Power Inlet Module on. Turn timer key on. Press Start/Stop button on timer. Confirm unit powers up, and lights illuminate. See tip if lamps do not light. Reinstall head cover screws. Tip: If head lights flickered then went out after replacing F2 fuse; the fuse may have blown again. Ship more fuses to customer, if required, and replace fuse again prior to replacing the head. Figure 1 Figure 2 Figure 3 Chart 15

22 DUSA Pharmaceuticals, Inc. Frequently Asked Questions Wavelength of BLU-U? 417 nm ± 5 nm (nm = nanometers) Power output of lamps? The BLU-U lamp power output is 9-11 mw/cm 2. The BLU-U delivers 10 Joules/cm 2 during the approved treatment time of 16:40. Customer can reference MAN-1211 Operating Manual, page 12, Procedure for treating acne, number 3. Can lamps be replaced in the field?, lamps cannot be replaced in the field. This is because the lamps are calibrated as a set in the head and lamp replacement requires recalibration of the head. Can the BLU-U be used with one or more lamps not lit?, the BLU-U should not be used when lamps are out. Check lamp connectors (see Chart 14) and terminal block in head (see Chart 12). If problem is not resolved, a replacement head is recommended. BLU-U longevity -or- number of cycles? 6K units run to 1600 cycles, 1K & 3K units run to 500, 1050 or 1600 cycles. The status indicator light will be on steady or intermittent and the lamps will be lit. See Chart 10 for instructions to check number of hours on Timer 1. Does the BLU-U require Preventive Maintenance? The BLU-U does not require scheduled preventive maintenance. The BLU-U is calibrated to 9-11 mw/cm 2 at the factory and the calibration is monitored by the electronics in the head. If a units power output is above or below the 9-11 mw/cm 2 specification the Status Indicator will illuminate and DUSA should be contacted at this time. What parts are serviceable on the BLU-U? The customer can change parts such as fuses and knobs in the field. Other components which can be changed in the field, such as the power inlet module or caster upgrade, require a MERA technician. Field replaceable parts can be found on FORM281. Why do the lamps change brightness, or pulse, during power up or operation? The lamp pulsing is normal as the electronics in the head regulate the lamp power output. If there is a lamp power output issue or electronics problem the system status indicator lamp will flash (see operating manual for error conditions) and the customer should contact DUSA customer service to troubleshoot and resolve. What safety materials or information is there for the BLU-U? Safety information can be found in MAN-1211 Operating Manual, page 4. What is the difference between patient goggles and physician goggles? Patient goggles are small and fit just over the eyes. Clinician goggles are larger. Chart 16

23 DUSA Pharmaceuticals, Inc. Timer 1: Codes to Clear F101/F202 Errors Continued on next page Chart 17

24 DUSA Pharmaceuticals, Inc. Timer 1: Codes to Clear F101/F202 Errors Chart 18

Troubleshooting Guide: 255 LED Light

Troubleshooting Guide: 255 LED Light Troubleshooting Guide: 255 LED Light Note Use only factory replacement lights (refer to parts list for order number). Caution Carefully handle parts near membranes and wire harnesses. Allow the light to

More information

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL INSTALLATION MANUAL 51170 SPECTRUM BRAKE CONTROL TABLE OF CONTENTS Controls & Components Tools List Before You Begin Wiring Wiring Diagram Mounting the LED Display Rotary Knob Wiring the Plug Connector

More information

Detroit Speed, Inc. Electric Headlight Door Kit Corvette P/N: &

Detroit Speed, Inc. Electric Headlight Door Kit Corvette P/N: & Detroit Speed, Inc. Electric Headlight Door Kit 1968-82 Corvette P/N: 122006 & 122007 The Detroit Speed Inc. Electric Headlight Door Kit replaces the stock vacuum actuated system on all 1968-82 Corvettes.

More information

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (12V) Troubleshooting Guide: 355 Lights (12V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling)

More information

If You Are Experiencing This, Click Thru:

If You Are Experiencing This, Click Thru: HTM04 0 Jericho Turnpike New Hyde Park, NY 040 Tel: () 38-3970 Fax: () 38-7 www.techno-isel.com Techno Stepper DaVinci Trouble Shooting Guide Power Entry Module E-Stop Button 3 Inside 4 Inside 4 3 If You

More information

Troubleshooting Guide: 355 Lights (24V)

Troubleshooting Guide: 355 Lights (24V) Troubleshooting Guide: 355 Lights (24V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling)

More information

PONTIAC FIREBIRD

PONTIAC FIREBIRD 1974-78 PONTIAC FIREBIRD Two Panel Sequential LED Tail Light Kit Installation Guide Kit Contents: 2 LED panels 2 LED panel mount kits 6 rubber grommets 1 power wire 1 pigtail harness Kit 1 crimp terminal

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER Table of Contents Page Tools Needed (A) 3 Replacement

More information

TC1000 Service Manual SALES: CUSTOMER SERVICE:

TC1000 Service Manual SALES: CUSTOMER SERVICE: TC1000 Service Manual SALES: 800-278-3933 CUSTOMER SERVICE: 800-745-1373 Table of Contents Section Page I. Overview 2 II. Troubleshooting Tables 3 III. Maintenance Procedures Procedure 1 Removal and Reinstallation

More information

TOYOTA CAMRY HANDS FREE BLU LOGIC Preparation

TOYOTA CAMRY HANDS FREE BLU LOGIC Preparation TOYOTA CAMRY 2008- HANDS FREE BLU LOGIC Preparation Part #: PT923-00111 Conflicts: JBL Audio, Factory Navigation NOTE: Part number of this accessory may not be the same as the part number shown. Kit Contents:

More information

ALU-29CF Portable Light NSN:

ALU-29CF Portable Light NSN: ALU-29CF Portable Light NSN: 6520-01-446-4170 COMMAND l AIR OPERATION / MAINTENANCE MANUAL & PARTS LIST TABLE OF CONTENTS Introduction................................................................3 Purpose.............................................................3

More information

PN R CHEVY CAMARO w/reverse Two panel Sequential LED Taillight kit installation guide. Kit Contents:

PN R CHEVY CAMARO w/reverse Two panel Sequential LED Taillight kit installation guide. Kit Contents: Two panel Sequential LED Taillight kit installation guide Kit Contents: 2 LED panels 4 rubber grommets 1 power wire with t-tap 1 driver side LED harness, 24 1 passenger side LED harness, 48 2 LED extension

More information

Service Manual Mozart Fireplace

Service Manual Mozart Fireplace Service Manual Mozart Fireplace Model Numbers: CFP3913 REV PCN DATE 00 11637 Sep 23, 09 Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1-888-346-7539 www.dimplex.com In

More information

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair. thru 391-001 -002 Otolaryngology Chair Serial Number Prefixes: EN, PD & V Service and Parts Manual NO LONGER IN PRODUCTION Some service parts may not be available for this product. 391-001 thru -002 NOTE:

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide 1 TABLE OF CONTENTS How To Use Guide...3 Figure 1...4 Figure 2......5 Electrical Problems...6 Vacuum Motor Problems...8 Fragrance Delivery Problems...10 Timer Problems...15 Coin/Bill

More information

5000TOC Sensor Service Manual

5000TOC Sensor Service Manual Part No. 84449 5000TOC Sensor Service Manual This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied (other

More information

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce USER S MANUAL TUBE SEALER Model SE250 No. CAT.SE25010Ce Centron Technologies Corporation 319-25 Sadang-4-dong, Dongjak-ku Seoul, Korea 156-823 Tel. +82-2.522.7807 Fax +82-2.522.7806 Important Note 1. Safety

More information

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number 28640996 and After Record Platter System Identification Numbers Here: Model # Serial # Table of Contents Program

More information

OLYMPIAN MODEL 740 Operation and Service Manual

OLYMPIAN MODEL 740 Operation and Service Manual OLYMPIAN MODEL 740 Operation and Service Manual P/N 133911-102 FCI MANUAL P/N 133865-001 Data herein has been verified and validated and believed adequate for the intended use. If the machine or procedures

More information

SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1)

SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1) SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1) IMPORTANT Before performing any Service Operation or other procedure described in this Section, refer to Section 00 CAUTIONS AND NOTES

More information

9.2, 9.2s, 9.20, 9.20s Treadmill

9.2, 9.2s, 9.20, 9.20s Treadmill 9.2, 9.2s, 9.20, 9.20s Treadmill Warning: This service manual is for use by Precor trained service providers only. If you are not a Precor Trained Servicer, you must not attempt to service any Precor Product;

More information

2005 and 09 Mustang install instructions Sequential / Chase Unit Partial Plug-N-Play Kit Meter4it Eng. Updated: 3/28/09

2005 and 09 Mustang install instructions Sequential / Chase Unit Partial Plug-N-Play Kit Meter4it Eng. Updated: 3/28/09 Updated: 3/28/09 Verify content of kit: 1- Unit with wiring harness 1- Red power wire with 15 amp fuse 1- Color instruction 2- Velcro for mounting 1-Driver taillight harness 1- Passenger taillight harness

More information

********SERVICE MANUAL********* MODELS:

********SERVICE MANUAL********* MODELS: ********SERVICE MANUAL********* MODELS: -------------- 7553-70 Variable Speed Drive/Controller System, 600 rpm, 115v 7553-71 Variable Speed Controller only, 600 rpm,115v 7553-80 Variable Speed Drive/Controller

More information

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company Oreck Magnesium Series Service Manual The Oreck Manufacturing Company 08/2012 10/2011 The Oreck Manufacturing Company Contents Covering all Magnesium Upright Models Including: LW100, LW125, LW1000, AND

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. P/N 08V31-SDA-102 2007 ACCORD 4-DOOR AII 32672 Issue Date JULY 2006 NOTE: Fog lights can be installed in a vehicle equipped with a factory

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

Source Capture Air Purification System

Source Capture Air Purification System Source Capture Air Purification System HA-SCP-G3 Owner s Manual Table of Contents HealthyAir HA-IFM-1111 Filter 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Packing

More information

ENERGY SMART TROUBLESHOOTING

ENERGY SMART TROUBLESHOOTING ENERGY SMART TROUBLESHOOTING Symptom No power to the unit. Possible Solution Verify the unit is plugged into a 20 Amp, GFCI circuit and the Power Switch is set to the ON position. Is the GFCI circuit breaker

More information

Detroit Speed, Inc. Electric Headlight Door Kit Corvette P/N: &

Detroit Speed, Inc. Electric Headlight Door Kit Corvette P/N: & Detroit Speed, Inc. Electric Headlight Door Kit 1968-82 Corvette P/N: 122006 & 122007 The Detroit Speed Inc. Electric Headlight Door Kit replaces the stock vacuum actuated system on all 1968-82 Corvettes.

More information

Bubble King. User Manual

Bubble King. User Manual Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. P/N 08V31-SDA-102 2007 ACCORD HYBRID AII 32762 Issue Date JULY 2006 NOTE: The outside temperature gauge cannot be installed in a vehicle

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 24307 SYSTEM 2003 ELEMENT Issue Date DEC 2002 NOTE: An optional keyless entry system (sold seperately) must be installed before you

More information

T621 Repair Manual (Electronics)

T621 Repair Manual (Electronics) T621 Repair Manual (Electronics) Table of Contents 1-1-1. Product Picture-T621 1-2-1. Display-T621 1-3-1. Component Placement-T621 Display 1-3-2. Component Placement-T621 Drive Board Area 1-4-1. Block

More information

Mazda S

Mazda S INSTALLATION INSTRUCTIONS FOR PART 99-7523S KIT FEATURES Double DIN radio provision ISO DIN radio provision with pocket Painted silver Pre-wired ASWC-1 harness included (ASWC-1 sold separately) APPLICATIONS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. SYSTEM 2005 ACCORD All 27511 (DX, LX) 2-AND 4-DOOR Issue Date AUG 2004 PARTS LIST Security System Attachment (LX): P/N 08E55-SDA-100A Unit

More information

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL MX3510 Includes Installation, Operation, and Service Instructions CAUTION Read complete instructions before operating. Please file for future reference.

More information

Validator and Control Board Update Instructions for BC1

Validator and Control Board Update Instructions for BC1 Validator and Control Board Update Instructions for BC1 Installation Overview The update kit for the Rowe BC1 enables the changer to interface with a Mars AE/VN 120-volt validator. The validator determines

More information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more

More information

Detroit Speed, Inc. RS Electric Headlight Door Kit 1969 Camaro P/N: (3)

Detroit Speed, Inc. RS Electric Headlight Door Kit 1969 Camaro P/N: (3) Detroit Speed, Inc. RS Electric Headlight Door Kit 1969 Camaro P/N: 122001 (3) (1) (2) (5) (4) Figure 1 Item QTY Description 1 1 LH actuator w/bracket and linkage 2 1 RH actuator w/bracket and linkage

More information

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical

More information

Solstice Electric Fryers SE Series Service Manual

Solstice Electric Fryers SE Series Service Manual Solstice Electric Fryers SE Series Service Manual L22-330 R1 (10/12) Notice In the event of problems or questions about your order, contact the Pitco Frialator factory at (603) 225-6684. In the event of

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. S P/N 08V31-SCV-102 2008 ELEMENT AII 36531 Issue Date MAY 2007 PARTS LIST 15 Wire ties 2 Fog lights 4 Wire ties with clip Switch harness

More information

LS200 Procedure Light

LS200 Procedure Light SERVICE MANUAL LS200 Procedure Light MODELS: 44200...Domestic 44202...Europe 44204...U.K. 44206...Australia 44210...Wall Mount 44250...Mobile Stand Copyright 1995 Welch Allyn Co. 4341 State Street Road

More information

Deep Space Lighting. VOLVO VNL BI-XENON HEADLAMP KIT Installation Instructions. Tools Needed: #2 Philips screwdriver 10mm socket and ratchet

Deep Space Lighting. VOLVO VNL BI-XENON HEADLAMP KIT Installation Instructions. Tools Needed: #2 Philips screwdriver 10mm socket and ratchet Deep Space Lighting VOLVO VNL BI-XENON HEADLAMP KIT Installation Instructions Estimated Installation Time: 15-45 minutes Tools Needed: #2 Philips screwdriver 10mm socket and ratchet Before starting, make

More information

9.17, 9.17si Treadmill

9.17, 9.17si Treadmill 9.17, 917si Treadmill 9.17, 9.17si Treadmill Warning: This service manual is for use by Precor trained service providers only. If you are not a Precor Trained Servicer, you must not attempt to service

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 24288 S ELEMENT Issue Date DEC 2002 PARTS LIST Fog Light Kit ( P/N 08V31-SCV-100 2 Fog lights Switch harness TOOL AND SUPPLIES REQUIRED

More information

P-600. Technical Manual. Troubleshooting Repairs Replacements

P-600. Technical Manual. Troubleshooting Repairs Replacements P-600 Technical Manual Troubleshooting Repairs Replacements Table of Contents P-600 Lift Symptoms and Problems Finding the Problem Before Getting Inside 3 Pneumatic Systems 4 Electrical Systems 5 Mechanical

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 24664-25319 SYSTEM 2003 CR-V Issue Date MAY 2003 PARTS LIST Security System (sold separately) P/N 08E51-EP4-100 Security System Attachment

More information

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

Part Number cc/min Water/Methanol Injection Flow Gauge

Part Number cc/min Water/Methanol Injection Flow Gauge Part Number 30-5141 500 cc/min Water/Methanol Injection Flow Gauge Figure 1. Wiring Schematic This product is legal in California for racing vehicles only and should never be used on public highways. AEM

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. SYSTEM ACCORD 2-DOOR (LX/EX L4, LX V6) AII 25749 Issue Date FEB 2004 PARTS LIST Double-sided adhesive tape XM Radio Attachment Kit : P/N

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. S P/N 08V31-SCV-100B 2008 ELEMENT (SC) AII 36532 Issue Date MAY 2007 PARTS LIST Relay bracket Right fog light Relay Left fog light Fuse

More information

Conflicts: JBL Audio, Factory Navigation, Accessory XM Satellite Radio, and Accessory Sirius Satellite Radio

Conflicts: JBL Audio, Factory Navigation, Accessory XM Satellite Radio, and Accessory Sirius Satellite Radio TOYOTA YARIS SEDAN 2008- HANDS FREE BLU LOGIC Preparation Part #: PT923-00111 NOTE: Part number of this accessory may not be the same as the part number shown. Conflicts: JBL Audio, Factory Navigation,

More information

Tension Control System MCS-166, MCS-203, MCS-204

Tension Control System MCS-166, MCS-203, MCS-204 Tension Control System MCS-166, MCS-203, MCS-204 P-257-WE 819-9027 Installation & Operation Instructions An Altra Industrial Motion Company Table of Contents Introduction...3 Specifications... 3-4 Installation

More information

Technical Manual. Table of Contents

Technical Manual. Table of Contents Technical Manual Table of Contents Section Page 1. FASTDRAW System Description... 2 2. FASTDRAW Equipment Available... 3 3. FASTDRAW Equipment Packing Lists... 3 4. Parts Diagram... 4 5. Pre-Installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. All 27176-28932 2005 CR-V Issue Date S P/N 08V31-S9A-115 FEB 2005 PARTS LIST 6 Washer-bolts Left fog light 6 Spring nuts Harness bracket

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 7.5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND

More information

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

Cybex Arc Trainer Owner s & Service Manual. 7 - Service 7 - Service Table of Contents......... iii Warnings/Cautions All warnings and cautions listed in this chapter are as follows:! WARNING: All maintenance activities shall be performed by qualified personnel.

More information

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72 Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72 KIT COMPONENTS: One (1) Digital Circuit Board One (1) Smoked Acrylic See-Through Lens *Peel off protective covering from both sides of lens attached

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. All 27176 2005 CR-V Issue Date P/N 08V31-S9A-114 SEP 2004 PARTS LIST 25 Wire ties Left fog light 6 Washer-bolts Right fog light 6 Spring

More information

9.33i, 9.35i Treadmill

9.33i, 9.35i Treadmill 9.33i, 9.35i Treadmill Warning: This service manual is for use by Precor trained service providers only. If you are not a Precor Trained Servicer, you must not attempt to service any Precor Product; Call

More information

Please forward any questions or comments regarding this Troubleshooting Guide to

Please forward any questions or comments regarding this Troubleshooting Guide to 2009 Human Touch, LLC. All rights reserved. May 28, 2009 Please forward any questions or comments regarding this Troubleshooting Guide to documentation@humantouch.com. HT-1650 Troubleshooting This Troubleshooting

More information

COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL

COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL Copyright 2003 VALPAR International Corporation P.O. Box 5767 Tucson, Arizona 85703-5767 All rights reserved. No part of this manual

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. P/N 08V31-SDN-100 2004 ACCORD 2-DOOR AII 25735 Issue Date SEP 2003 NOTE: The outside temperature gauge can not be installed in a vehicle

More information

PowerOhm Installation Manual for LG ATV Series Braking Modules

PowerOhm Installation Manual for LG ATV Series Braking Modules PowerOhm Installation Manual for LG ATV Series Braking Modules IMPORTANT: These instructions should be read thoroughly before installation. All warnings and precautions should be observed for both personal

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1433-000-E, 1434-000-E, 1456, 1457 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804

More information

RAAS Troubleshooting Guide. Confirm that the power switch to the unit is in the on position.

RAAS Troubleshooting Guide. Confirm that the power switch to the unit is in the on position. RAAS 2.5-300 Troubleshooting Guide 1 Power Out Confirm that the power switch to the unit is in the on position. - The power switch is located to the lower left on the interior of the cabinet. It is a large

More information

PARTS LIST. REPLACEMENT PARTS and ACCESSORIES PREPARATION VN1600. PREPARATION VN1500D and VN800B

PARTS LIST. REPLACEMENT PARTS and ACCESSORIES PREPARATION VN1600. PREPARATION VN1500D and VN800B INSTALLATION AND OWNER S MANUAL Light Bar N925 for Installation to: Kawasaki VN1500D&E and VN800B Pages 1,2,3 and 5 Kawasaki VN1600 Pages 1, 4 and 5 PARTS LIST QTY. PART NO. DESCRIPTION 1 N925 Light Bar

More information

ISO1000R Service Manual SALES: CUSTOMER SERVICE:

ISO1000R Service Manual SALES: CUSTOMER SERVICE: ISO1000R Service Manual SALES: 800-278-3933 CUSTOMER SERVICE: 800-745-1373 Revision: August 1999 Table of Contents Section Page I. Overview 2 II. Troubleshooting Tables 3 III. Maintenance Procedures Procedure

More information

POLARIS 4500 HD WINCH KIT

POLARIS 4500 HD WINCH KIT POLARIS 4500 HD WINCH KIT P/N 2883860 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain

More information

SCION TC HANDS FREE BLU LOGIC Preparation

SCION TC HANDS FREE BLU LOGIC Preparation SCION TC 2008- HANDS FREE BLU LOGIC Preparation Part #: PT923-00099 Conflicts: JBL Audio NOTE: Part number of this accessory may not be the same as the part number shown. Kit Contents: For kits manufactured

More information

Detroit Speed, Inc. RS Electric Headlight Door Kit 1968 Camaro P/N: (3)

Detroit Speed, Inc. RS Electric Headlight Door Kit 1968 Camaro P/N: (3) Detroit Speed, Inc. RS Electric Headlight Door Kit 1968 Camaro P/N: 122002 (3) (1) (2) (5) (4) Figure 1 Item QTY Description 1 1 LH Actuator w/bracket and Linkage 2 1 RH Actuator w/bracket and Linkage

More information

FE 35, 40, 55, EC Every time you open the housing, clean the motor with a soft brush.

FE 35, 40, 55, EC Every time you open the housing, clean the motor with a soft brush. FE 35, 40, 55, EC 70 1 Service Manual FE 35, FE 40, FE 55 Electric Trimmers, EC 70 Electric Edger As the design concept of the FE 35 and FE 40 trimmers is almost identical, the descriptions and servicing

More information

USB Charge Port Installation Instructions

USB Charge Port Installation Instructions USB Charge Port Installation Instructions Lifetime Technical Support support@logolites.com 770-476-7322 www.logolites.com Manual 100-0014C Thank you for purchasing a Logo Lites USB Charge Port! USB Charge

More information

SX1000 Service Manual SALES: CUSTOMER SERVICE:

SX1000 Service Manual SALES: CUSTOMER SERVICE: SX1000 Service Manual SALES: 800-278-3933 CUSTOMER SERVICE: 800-745-1373 Revision: August 1999 Table of Contents Section Page I. Overview 2 II. Troubleshooting Tables 3 III. Maintenance Procedures Procedure

More information

Quickie S-11 Service Manual

Quickie S-11 Service Manual Quickie S-11 Service Manual 05 Sunrise Medical Inc. 100740 Rev A Quickie S-11 Troubleshooting Guide INTRODUCTION... 0.1 Specifications VSI Controller... 0.2 Plugs/Connectors... 0.3 Main Wiring Diagram/

More information

Spray Height Controller

Spray Height Controller Spray Height Controller UC5 SERVICE MANUAL 2012 Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC5 SERVICE MANUAL 2012 Rev B NOTICE: NORAC Systems International Inc.

More information

DEFINITIONS OF SAFETY TERMS DANGER indicates an imminent hazard. If you fail to avoid this hazard, it WILL cause death or serious injury.

DEFINITIONS OF SAFETY TERMS DANGER indicates an imminent hazard. If you fail to avoid this hazard, it WILL cause death or serious injury. CRUIS N EXOTICA S E C T I O N THREE Service SAFETY INSTRUCTIONS The following safety instructions apply to operators and service personnel. Read these instructions before servicing or preparing the Video

More information

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual 200 Shadylane Drive Philipsburg, PA 16866 Phone: (814) 342-6205 Fax: (814) 342-4510 www.druckerdiagnostics.com Service Manual Model 755VES Centrifuge MODEL 755VES SERVICE MANUAL REV: A 1 CONTENTS 1 PREFACE...

More information

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

VECTRIX VX-2 SERVICE MANUAL.   Version 1.0/May 2011 VECTRIX, LLC www.vectrix.com CONTENTS SECTION A: Tools 1 Tools Needed SECTION B: Mechanical Parts 1 Front Fairing 2 Front Console Cover 3 Speedometer Cover 4 Front Vertical Panel Cover-Lower 5 Front Vertical Panel

More information

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual FinishPro 390/395 Airless/AirAssisted Sprayer Repair Electrical Manual First choice when quality counts. Rev. B 10/11 /07 FinishPro 395 3.00 ti9026a Red Yel Yel Air Hose Connection FinishPro 390 Exhaust

More information

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18) LED Exam Light Model Numbers: 253 Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY 004-0779-00 Rev. (1/23/18) Table of Contents Section C Section B Section A General Info GENERAL INFORMATIOn

More information

AQUOS LE810/820 QUATTRON LED REPLACEMENT LC-60LE810/820

AQUOS LE810/820 QUATTRON LED REPLACEMENT LC-60LE810/820 AQUOS LE810/820 QUATTRON LED REPLACEMENT LC-60LE810/820 Ver. FF Kit LEDKIT60LE8x Part number: LEDKIT60LE8x AQUOS LE810/820 QUATTRON LED REPLACEMENT LEDKIT60LE8X (1) Wiring Harness (1) Side LED Strip (2)Top

More information

ONE TOUCH CONTROL BOX

ONE TOUCH CONTROL BOX ONE TOUCH CONTROL BOX CONVERSION KIT INSTRUCTIONS REMOVAL, INSTALLATION, OPERATION, AND REMOTE CONTROL PROGRAMMING THUNDERSTONE PART #101322 REVISION A JULY 14 TH 2016 2 P a g e INSTALLING THE THUNDER

More information

SCION tc SECURITY (V5) Preparation

SCION tc SECURITY (V5) Preparation Preparation Part Number: PT398-21070 Kit Contents Item # Quantity Reqd. Description 1 1 2 1 GBS ECU Hardware Bag Contents Item # Quantity Reqd. Description 1 1 V5 Security ECU 2 1 ECU Mounting Bracket

More information

Tru-Billet Climate Control Knob Installation Instructions

Tru-Billet Climate Control Knob Installation Instructions P/N S197-525-07 2007-08 Tru-Billet Climate Control Knob Installation Instructions Thank you for your purchase of SilverHorse Racing products. Please read all directions before beginning the installation.

More information

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS Customer Service and Technical Support: 8:00 AM to 5:00 PM central (M-Th) 8:00 AM to 4:30 PM central (Fri) Phone: 800-257-7407

More information

POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS

POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS AN POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS page GENERAL INFORMATION INTRODUCTION...1 POWER LOCK SYSTEM...1 REMOTE KEYLESS ENTRY SYSTEM...1 DESCRIPTION AND OPERATION CENTRAL TIMER

More information

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX10 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A.

More information

HOW - TO WIRING & LIGHTING

HOW - TO WIRING & LIGHTING HOW - TO WIRING & LIGHTING Tool And Material Checklist Test Light Service Manual Penetrating Oil Long-Nose Pliers T-Square or Right Angle Screwdriver Black Electrical Tape Fuses Fuse Puller Cloth or Paper

More information

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge 200 Shadylane Drive Philipsburg, PA 16866 Phone: (814) 342-6205 Fax: (814) 342-4510 www.druckerdiagnostics.com Service Manual Model 642E Centrifuge MODEL 642E SERVICE MANUAL REV: Original Issue 1 CONTENTS

More information

Section 7 - Troubleshooting Guide

Section 7 - Troubleshooting Guide Section 7 - Troubleshooting Guide Section 7 - Troubleshooting Guide IMPORTANT While this troubleshooting guide provides information to aid in troubleshooting problems with the range, it does not contain

More information

4000 SYSTEM OPERATING MANUAL

4000 SYSTEM OPERATING MANUAL 4000 SYSTEM OPERATING MANUAL REV 1.4 COPYRIGHT 1996 Xenotech, Inc. PAGE 1 INSTRUCTIONS FOR REMOVING AND INSTALLING A TYPE XT XENON BULB IN A BL4000 FIXTURE NOTE FAMILIARIZE YOURSELF WITH THE LOCATION AND

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 23086 SYSTEM CR-V Issue Date NOV 2001 PARTS LIST Security System P/N 08E51-EP4-100 Security System Attachment P/N 08E55-S9A-100 Security

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

T-Dolly Troubleshooting Guide

T-Dolly Troubleshooting Guide T-Dolly Troubleshooting Guide Complete following items before beginning troubleshooting 1. Place wheel chocks and jack stands in place per the BLOCKING DIAGRAM decal. Located on the underside of the pump

More information