NCS12 Series Isolated 12W 4:1 Input Single & Dual Output DC/DC Converters

Size: px
Start display at page:

Download "NCS12 Series Isolated 12W 4:1 Input Single & Dual Output DC/DC Converters"

Transcription

1 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters FEATURES UL 95 recognition pending :1 Wide range voltage input Operating temperature range - C to 5 C Typical load regulation from.5% 1.5kVDC Isolation 3.3V, 5V, 1V & 15V outputs UL 9V- Package materials No electrolytic capacitors Thermal shutdown Under voltage lock out Current fold back PRODUCT OVERVIEW The NCS1 series of DC/DC converters offers single & dual output voltages from input voltage ranges of 9-3V and 1-75V. The NCS1 is housed in an industry standard package with a standard pinout. The NCS1 is packaged in a metal case for improved EMI shielding and is also encapsulated for superior thermal performance. Applications include telecommunications, battery powered systems, process control and distributed power systems. For full details go to /rohs SELECTION GUIDE Load Regulation Input Voltage Output Output Positive Negative Positive Negative Order Code Voltage Current Output Output Output Output Efficiency MTTF 1 Nom. Typical Max Min. Typ. V V A % % % % % Hrs NCS1S13C ,9 NCS1S15C ,57 NCS1S11C ,59 NCS1S115C ,59 NCS1S3C ,93 NCS1S5C ,117 NCS1S1C ,593 NCS1S15C ,5 NCS1D15C 1 ±5 ± ,55 NCS1D11C 1 ±1 ± ,75 NCS1D115C 1 ±15 ± ,35 NCS1D5C ±5 ± ,931 NCS1D1C ±1 ± ,533 NCS1D15C ±15 ± ,57 SELECTION GUIDE (Continued) Input Current Ripple and Noise 1% Load 1% Load 1% Load Order Code Typ. 1/V Typ. V Typ. 1/V Typ. Max A A A mvp/p mvp/p NCS1S13C NCS1S15C NCS1S11C NCS1S115C NCS1S3C NCS1S5C NCS1S1C NCS1S15C NCS1D15C NCS1D11C NCS1D115C NCS1D5C NCS1D1C NCS1D15C INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1V input types 9 3 Voltage range V V input types 1 75 Turn on threshold 1V input types.5 Turn off threshold 1V input types 7.5 Under voltage lock out V Turn on threshold V input types 1.7 Turn off threshold V input types 15. Power consumption at NCS1X1 1 mw shutdown NCS1X 1 V dual output types 15 Reflected ripple current ma p-p All other types 1 1 Calculated using MIL-HDBK-17 FN, parts stress method with nominal input voltage at full load. All specifications typical at TA=5 C, nominal input voltage and rated output current unless otherwise specified. KDC_NCS1C.A3 Page 1 of 1

2 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated power All output types 1 W Minimal load to meet datasheet specification 1 % Voltage set point accuracy Positive outputs ± Negative outputs ±3 % Line regulation Low line to high line Positive outputs..1 Negative outputs.3 1 % Cross Regulation D15 & D5 ± ±.5 D11, D115,D1, D15 ± ±5 % Transient response Peak deviation ( % & % swing) 5 %V out Settling time Single output types 5 (within 1% V out Nom.) Dual output types 5 μs ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 seconds 15 VDC Resistance Viso = 1kVDC 1 GΩ Capacitance S13, S15, S3, S5 All other types 3 pf ABSOLUTE MAXIMUM RATINGS Short-circuit protection (for SELV input voltages) 3 minutes Control pin input voltage 1V Max Lead temperature 1.mm from case for 1 seconds (to JEDEC JESD-B1 ISS C) C Input voltage, NCS1 1V input types V Input voltage, NCS1 V input types V GENERAL CHARACTERISTICS 1 Parameter Conditions Min. Typ. Max. Units Switching frequency S13, S15, S3 & S5 3 All other types khz Control pin input Module on, pin unconnected or open collector floating Module off. V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation With derating - see derating graph - 5 Storage Case temperature above ambient Thermal shutdown 1% Load, Nom VIN, Still Air Case Temperature NCS1S13C 5 NCS1S115C, NCS1D15C, NCS1D5C All other types Single 3.3V & 5V outputs 135 All other types 1 C KDC_NCS1C.A3 Page of 1

3 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters APPLICATION NOTES Output Capacitance and start-up times The NCS1 series does not require output capacitors to meet datasheet specification. To meet datasheet specification, total output capacitance should not exceed: Part No. Maximun Load Capacitance (per output) Start-up times μf ms NCS1S13C 7 1 NCS1S15C 7 NCS1S11C 7 NCS1S115C.5 NCS1S3C 7 1 NCS1S5C 7 NCS1S1C NCS1S15C.5 NCS1D15C 5 NCS1D11C 1 NCS1D115C 1 9 NCS1D5C 5 NCS1D1C NCS1D15C 1 7 TECHNICAL NOTES ISOLATION VOLTAGE Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand Voltage & Isolation Test Voltage are all terms that relate to the same thing, a test voltage, applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NCS1 series of DC/DC converters are all 1% production tested at their stated isolation voltage. This is 1.5kVDC for 1 second. A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation? For a part holding no specifi c agency approvals, such as the NCS1 series, both input and output should normally be maintained within SELV limits i.e. less than.v peak, or VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NCS1 series has an ER ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by % from specifi ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of ºC for 1 seconds. The pin termination finish on this product series is a Gold flash (.5-.1 micron) over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit /rohs KDC_NCS1C.A3 Page 3 of 1

4 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 1μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C than 1mΩ at 1 khz C3 1nF multilayer ceramic capacitor, general purpose R1 5Ω resistor, carbon film, ±1% tolerance R 5Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 1 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter SUPPLY + + Input Output C1 C C3 R1 T1 R OSCILLOSCOPE Y INPUT - - R LOAD KDC_NCS1C.A3 Page of 1

5 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters EFFICIENCY VS LOAD NCS1S13C NCS1S15C V 1V 7 5 V 1V % % 3% % 5% % 7% % 9% 1% 5 1% % 3% % 5% % 7% % 9% 1% NCS1S11C NCS1S115C 7 V 1V 7 7 V 1V % % 3% % 5% % 7% % 9% 1% 1% % 3% % 5% % 7% % 9% 1% NCS1S3C 9 NCS1S5C V V 7 5 V V % % 3% % 5% % 7% % 9% 1% 5 1% % 3% % 5% % 7% % 9% 1% NCS1S1C 9 NCS1S15C V V 75 V V % % 3% % 5% % 7% % 9% 1% 1% % 3% % 5% % 7% % 9% 1% KDC_NCS1C.A3 Page 5 of 1

6 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters EFFICIENCY VS LOAD NCS1D15C 9% NCS1D11C 9% % % 7% 7% % 5% % V 1V % 5% V 1V % 3% % 3% 1% 1% % 3% % 5% % 7% % 9% 1% % 1% % 3% % 5% % 7% % 9% 1% NCS1D115C 9% NCS1D5C 95% % 5% 75% 7% 5% % 5% V 1V 55% 5% V V 35% % 5% 3% 15% % 1% % 3% % 5% % 7% % 9% 1% 5% 1% % 3% % 5% % 7% % 9% 1% NCS1D1C NCS1D15C 9% 1% % 9% 7% % 7% % 5% % V V % 5% % V V 3% 3% % % 1% 1% % 3% % 5% % 7% % 9% 1% 1% 1% % 3% % 5% % 7% % 9% 1% KDC_NCS1C.A3 Page of 1

7 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters TEMPERATURE DERATING NCS1S13C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1S15C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1S11C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1S115C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm KDC_NCS1C.A3 Page 7 of 1

8 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters TEMPERATURE DERATING NCS1S3C Input Voltage Range = 1-75V Input Voltage = V lfm 1 lfm lfm lfm lfm lfm NCS1S5C Input Voltage Range = 1-75V Input Voltage = V lfm lfm lfm 1 lfm lfm lfm NCS1S1C 1 1 Input Voltage Range = 1-75V 1 1 Input Voltage = V 1 lfm lfm lfm 1 lfm lfm lfm NCS1S15C Input Voltage Range = 1-75V Input Voltage = V lfm 1 lfm lfm lfm lfm lfm KDC_NCS1C.A3 Page of 1

9 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters TEMPERATURE DERATING NCS1D15C 1 Input Voltage Range = 9-3V 1 Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1D11C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1D115C Input Voltage Range = 9-3V Input Voltage = 1V lfm lfm lfm 1 lfm lfm lfm NCS1D5C Input Voltage Range = 1-75V Input Voltage = V lfm 1 lfm lfm lfm lfm lfm KDC_NCS1C.A3 Page 9 of 1

10 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters TEMPERATURE DERATING NCS1D1C 1 Input Voltage Range 1-75V 1 Input Voltage = V lfm lfm lfm 1 lfm lfm lfm NCS1D15C Input Voltage Range = 1-75V Input Voltage = V lfm lfm lfm 1 lfm lfm lfm KDC_NCS1C.A3 Page 1 of 1

11 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters EMC FILTERING AND SPECTRA FILTERING The module includes a basic level of filtering, sufficient for many applications. Where lower noise levels are desired, filters can easily be added to achieve any required noise performance. A DC/DC converter generates noise in two principle forms: that which is radiated from its body and that conducted on its external connections. There are three separate modes of conducted noise: input differential, output differential and input-output. This last appears as common mode at the input and the output, and cannot therefore be removed by filtering at the input or output alone. The first level of filtering is to connect capacitors between input and output returns, to reduce this form of noise. It typically contains high harmonics of the switching frequency, which tend to appear as spikes on surrounding circuits. The voltage rating of this capacitor must match the required isolation voltage. (Due to the great variety in isolation voltage and required noise performance, this capacitor has not been included within the converter.) Input ripple is a voltage developed across the internal Input decoupling capacitor. It is therefore measured with a defined supply source impedance. Although simple series inductance will provide filtering, on its own it can degrade the stability. A shunt capacitor is therefore recommended across the converter input terminals, so that it is fed from a low impedance. If no filtering is required, the inductance of long supply wiring could also cause a problem, requiring an input decoupling capacitor for stability. An electrolytic will perform well in these situations. The input-output filtering is performed by the common-mode choke on the primary. This could be placed on the output, but would then degrade the regulation and produce less benefit for a given size, cost, and power loss. Radiated noise is present in magnetic and electrostatic forms. The latter is suppressed by the metal case, which is connected to the output return, typically a zero-volt point. Thanks to the small size of these units, neither form of noise will be radiated efficiently, so will not normally cause a problem. Any question of this kind usually better repays attention to conducted signals. EMC FILTER AND VALUES TO OBTAIN SPECTRA AS SHOWN The following filter circuit shows the input filter typically required to meet CISPR Quasi-PeakCurve B. C1 L1 C C3 DC DC C1, C 1μF Polyester or ceramic capacitor C3 7μF Electrolytic capacitor C & C5 1nF 5 VAC Y Rated (15nf SXX3 & SXX5) L1 1μH Common-mode choke (Murata part number 5115C) C5 C KDC_NCS1C.A3 Page 11 of 1

12 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters EMC FILTERING AND SPECTRA NCS1S13C NCS1S11C NCS1S3C NCS1S1C E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E+ NCS1S15C NCS1S115C NCS1S5C NCS1S15C E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E+ KDC_NCS1C.A3 Page 1 of 1

13 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters EMC FILTERING AND SPECTRA NCS1D15C NCS1D115C NCS1D1C E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E+ NCS1D11C NCS1D5C NCS1D15C E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E E+5 1.E+ 1.E+7 1.E+ KDC_NCS1C.A3 Page 13 of 1

14 NCS1 Series Isolated 1W :1 Input Single & Dual Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS.77 (.) NCS1S15C XYYWW 1. (3.) PIN CONNECTIONS Pin Function Single Dual 1 Control Control -VIN -VIN 3 -VIN -VIN 9 No pin V 11 N/C -VOUT 1 +VOUT +VOUT 1 V V +VIN +VIN 3 +VIN +VIN.39 (1.) TUBE OUTLINE DIMENSIONS 1.±.15 (.±.).17-. (.-5.7). (.5). (.5).5 (.335) 3. (.9). (5.) (.5) Tube length 5 (.7).5 (.7) All dimensions in mm (inches) ±.5 (.1). Quantity: 15. (15.) Bottom View RECOMMENDED FOOTPRINT DETAILS HOLES mm Ø.5 (.1).1 (.5).1-.7 (.1-5.) Weight: 17g All dimensions in inches (mm) ±. (.5) except pin to pin tolerance ±.1 (.5). All pins on a.1 (.5) pitch and within.1 (.5) of true position. The copper case is connected to the V pin(s). Care is needed in the design of this circuit board on which the converter is mounted. Top side tracks must not contact the edge of the case on the underside of the unit..5 (.1) All dimensions in mm (inches) ±.5 (±.1). Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA U.S.A. ISO 91 and 11 REGISTERED /support This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. 13 Murata Power Solutions, Inc. KDC_NCS1C.A3 Page 1 of 1

NCS6 Series Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters

NCS6 Series Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters FEATURES RoHS compliant : Wide range voltage input Operating temperature range C to 8 C Typical load regulation from.%.kvdc Isolation Typical effi ciency to 8% V & 8V Nominal input Power density.9w/cm

More information

NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters

NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters www.murata-ps.com NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters FEATURES UL 9 recognized RoHS compliant : Wide range voltage input Operating temperature range C to 8 C Short circuit

More information

NCS6 Series Isolated 6W 4:1 Input Single Output DC/DC Converters

NCS6 Series Isolated 6W 4:1 Input Single Output DC/DC Converters Isolated W : Input Single Output DC/DC Converters FEATURES RoHS compliant : Wide range voltage input Operating temperature range C to 8 C.% Typical load regulation.kvdc Isolation Effi ciency from % V &

More information

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage www.murata-ps.com CME Series SELECTION GUIDE FEATURES Single Isolated output 1kVDC or 3kVDC option Wide temperature performance at full 1 Watt load -40 C to 85C Industry Standard Pinout 3.3V and 5V Inputs

More information

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current www.murata-ps.com NML Series FEATURES RoHS compliant Single isolated output 1kVDC isolation Efficiency up to 85% Wide temperature performance at full 2 watt load, 40 C to 85 C Power density 2.01W/cm 3

More information

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters www.murata-ps.com NMA 5V, 12V & 15V Series FEATURES Efficiency up to 80% Wide temperature performance at full 1 Watt load, 40 C to 85 C Dual output from a single input rail Industry standard pinout Power

More information

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current www.murata-ps.com FEATURES RoHS compliant Efficiency up to 82% Wide temperature performance at full 1 Watt load, 40 C to 85 C UL 94V-0 package material Reduced footprint at 0.98cm 2 Industry standard pinout

More information

NMH Series Isolated 2W Dual Output DC/DC Converters

NMH Series Isolated 2W Dual Output DC/DC Converters www.murata-ps.com NMH Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Efficiency Isolation Capacitance MTTF1 V V ma ma % pf khrs Package

More information

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS MEE3 Series SELECTION GUIDE FEATURES UL 695 recognized RoHS compliant Typical efficiency from 83% Power density 2.68W/cm 3 Wide temperature performance at full 3 Watt load, 4 C to 85 C 3 UL 94V- package

More information

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage www.murata-ps.com SELECTION GUIDE - SINGLE OUTPUT 1 Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise

More information

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters www.murata-ps.com CMR Series SELECTION GUIDE FEATURES Short circuit protection options UL 60950 recognised Single or Dual Isolated Outputs 1kVDC or 3kVDC options Hi Pot Test Wide temperature performance

More information

MEE1 Series Isolated 1W Single Output DC/DC Converters

MEE1 Series Isolated 1W Single Output DC/DC Converters www.murata-ps.com MEE1 Series FEATURES UL69 recognised Operation to zero load Single isolated output 1kVDC isolation Hi Pot Test Efficiency up to 87% typical Wide temperature performance at full 1 watt

More information

NKE Series. Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES

NKE Series.   Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES www.murata-ps.com NKE Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Efficiency Isolation Capacitance MTTF 1 Package Style FEATURES RoHS

More information

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters www.murata-ps.com MTU1 Series SELECTION GUIDE FEATURES Patent Protected UL60950 recognised Footprint over pins 0.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 88% (Typ.)

More information

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters NMA 5V, 12V & 15V Series FEATURES RoHS compliant Effi ciency up to 80% Power density up to 0.85W/cm 3 Wide temperature performance at full 1 Watt load, 40 C to 85 C Dual output from a single input rail

More information

MEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters

MEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters www.murata-ps.com MEA1 Series FEATURES UL 695 recognised Typical efficiency to 89.5% 1kVDC isolation Hi Pot Test Wide temperature performance at full 1 Watt load, 4 C to 85 C Industry standard pinout Power

More information

SELECTION GUIDE. Nominal Input Voltage. Output Current. Output Voltage. Reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Current. Output Voltage. Reflected ripple current www.murata-ps.com SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Isolation Efficiency Capacitance MTTF1 V V ma % pf khrs Package Style FEATURES

More information

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters www.murata-ps.com MTU2 Series SELECTION GUIDE FEATURES Patent Protected UL 9 Recognised Footprint over pins.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 85% (Typ.)

More information

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

NXE1 Series Isolated 1W Single Output SM DC/DC Converters NXE1 Series SELECTION GUIDE FEATURES Patents pending Lower Profile UL695 Recognition pending ANSI/AAMI ES661-1 Recognition pending 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture

More information

NTA Series Isolated 1W Dual Output SM DC/DC Converters

NTA Series Isolated 1W Dual Output SM DC/DC Converters www.murata-ps.com NTA Series FEATURES RoHS compliant Efficiency up to 78% Wide temperature performance at full 1 Watt load, 40 C to 85 C UL 94V-0 Package material Footprint over pins 1.64cm 2 Lead frame

More information

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters MTC2 Series SELECTION GUIDE FEATURES UL 9 recognised for reinforced insulation ANSI/AAMI ES1-1, 1 MOPP/ 2 MOOPs recognised 3kVAC isolation test voltage Hi Pot Test Continuous short circuit protection Output

More information

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters www.murata-ps.com MEJ2 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise (Typ)

More information

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters www.murata-ps.com MEJ2 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise (Typ)

More information

MEV3 Series 3kVDC Isolated 3W Single Output DC/DC Converters

MEV3 Series 3kVDC Isolated 3W Single Output DC/DC Converters SELECTION GUIDE FEATURES RoHS compliant Typical effi ciency from 83% Power density 1.9W/cm 3 Wide temperature performance at full 3 Watt load, 4 C to 85 C UL 94V- package material No heatsink required

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognition pending ANSI/AAMI ES1-1 Recognition pending 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters NXJ2 Series SELECTION GUIDE FEATURES Patents pending Lower Profile UL69 Recognition pending ANSI/AAMI ES661-1, 2 MOOP, 1MOPP recognition pending 5.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85 SELECTION GUIDE Order Code 1 Nominal Input Voltage Output Voltage Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Efficiency

More information

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

NXE1 Series Isolated 1W Single Output SM DC-DC Converters NXE1 Series SELECTION GUIDE Order Code 1 Nominal Input Voltage Output Voltage Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise

More information

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES-, 2 MOOP, MOPP Recognised 4.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES1-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry Standard Footprint

More information

SELECTION GUIDE. Nominal Input Voltage. Voltage Order Code1. Output

SELECTION GUIDE. Nominal Input Voltage. Voltage Order Code1. Output CRE1 Series www.murata-ps.com FEATURES UL 69 recognised3 Single Isolated output 1kVDC or 3kVDC option Hi Pot Test Wide temperature performance at full 1W load - C to 8 C4 Industry Standard Pinout 3.3V,

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

NXE2 Series Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

NME 5V & 12V Series Isolated 1W Single Output DC/DC Converters

NME 5V & 12V Series Isolated 1W Single Output DC/DC Converters FEATURES RoHS compliant Single isolated output 1kVDC isolation Efficiency up to 80% Wide temperature performance at full 1 watt load, 40 C to 85 C Power density 1.53W/cm 3 UL 94V-0 package material Footprint

More information

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W (S)D-2W Isolated 2W Single Output DC/DC Converters SELECTION GUIDE Order code Input Voltage (V) Output Voltage (V) Output Current (MA) Input Current (Rated Load) (MA) Efficiency (%) Isolation Capacitance

More information

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage www.murata-ps.com NTE Series FEATURES RoHS compliant Lead frame technology Single isolated output 1kVDC Isolation Efficiency up to 78% Power density 1.8W/cm 3 Wide temperature performance at full 1 Watt

More information

SELECTION GUIDE. Order code B0303NXT-1W B0305NXT-1W B0309NXT-1W

SELECTION GUIDE. Order code B0303NXT-1W B0305NXT-1W B0309NXT-1W B-NXT-1W 1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER FEATURES Footprint over pins 1.37cm 2 Short Circuit Protection(automatic recovery) I/O isolation voltage 1000VDC Operating Temperature:

More information

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W Isolated 1W Single Output DC/DC Converters SELECTION GUIDE Order code Input Voltage (V) Output Voltage (V) Output Current (MA) Input Current (Rated Load) (MA) Efficiency (%) Isolation Capacitance (PF)

More information

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code 1. V V ma

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code 1. V V ma www.murata-ps.com CRE1 Series SELECTION GUIDE FEATURES UL 69 recognised 3 Single Isolated output 1kVDC or 3kVDC option Hi Pot Test Wide temperature performance at full 1W load -4 C to 85 C 4 Industry Standard

More information

SELECTION GUIDE. Order code Voltage(VDC) NTE0303XMC NTE0305XMC

SELECTION GUIDE. Order code Voltage(VDC) NTE0303XMC NTE0305XMC 1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER FEATURES Footprint over pins 1.37cm 2 Short Circuit Protection(automatic recovery) I/O isolation voltage 1000VDC Operating Temperature: -40 ~+85

More information

NME 5V & 12V SERIES. Technical enquiries tel: +44 (0) Isolated 1W Single Output DC/DC Converters

NME 5V & 12V SERIES.  Technical enquiries   tel: +44 (0) Isolated 1W Single Output DC/DC Converters FEATURES RoHS compliant Single isolated output 1kVDC isolation Efficiency up to 80% Wide temperature performance at full 1 watt load, 40 C to 85 C Power density 1.53W/cm 3 UL 94V-0 package material Footprint

More information

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters www.murata-ps.com MGJ1 Series FEATURES Patent pending Optimised bipolar output voltages for IGBT/ SiC & MOSFET gate drives Reinforced insulation to UL69 recognised ANSI/AAMI ES661-1 recognition pending

More information

NMJ Series 5.2kVDC Isolated 1W DC-DC Converters

NMJ Series 5.2kVDC Isolated 1W DC-DC Converters www.murata-ps.com NMJ Series FEATURES UL60950 recognised Wide temperature performance at full 1 watt load, 40 to 85 Single and dual outputs SIP package style 5.2kVD isolation Hi Pot Test 3V, 5V & 12V input

More information

MGJ6 14mm Series 10.2kVDC Isolated 6W Gate Drive SM DC/DC Converters

MGJ6 14mm Series 10.2kVDC Isolated 6W Gate Drive SM DC/DC Converters www.murata-ps.com MGJ6 14mm Series 1.2kVDC Isolated 6W Gate Drive SM DC/DC Converters SELECTION GUIDE Output 1 Output 2 FEATURES Patents protected No opto feedback Optimised bipolar output voltages for

More information

OBSOLETE SELECTION GUIDE 1. Recommended alternative: OKY-T/10-W5P-C >> click here to download the data sheet

OBSOLETE SELECTION GUIDE 1. Recommended alternative: OKY-T/10-W5P-C >> click here to download the data sheet NNL10 Series FEATURES RoHS compliant Industry standard footprint Short circuit protection High effi ciency Under voltage lock out Output voltage trimming Operating temperature range -40ºC to 85ºC SMD Construction

More information

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033 DC/DC High Efficiency Regulated Output W Minmax MKW Series FEATURES Smallest Encapsulated W Ultra-compact 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage Excellent Efficiency

More information

(typ.) (Range) ±18 330# 89 MPW MPW

(typ.) (Range) ±18 330# 89 MPW MPW DC/DC 30W, Single & Dual Output FEATURES 2 x 1.6 x 0.4 Metal Package Ultra-wide 4:1 Input Range Operating Temp. Range 40 C to 80 C Short Circuit Protection I/O-isolation 1500 VDC Input Filter meets EN

More information

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033 MKW SERIES DC/DC CONVERTER W, Highest Power Density FEATURES Smallest Encapsulated W Ultra-compact 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage Excellent Efficiency up to

More information

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S MKW SERIES DC/DC CONVERTER W, Highest Power Density FEATURES Smallest Encapsulated W Ultra-compact 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage Excellent Efficiency up to

More information

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2. FEATURES Industrial Standard 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage High Efficiency up to 88% I/O Isolation 1500 VDC Operating Ambient Temp. Range -40 to 85 Overload

More information

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features: DC/DC Converter 18-36 VDC Input 5.1 VDC Output at 2.4A Features: Applications: Distributed Power Architectures Communications Equipment Computer Equipment Work Stations UL TUV CB CE MARK RoHS Compliant

More information

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ. FEATURES 2"x 1"x 0.4" Metal Package Wide 2:1 Input Range High Efficiency up to % Operating Ambient Temp. Range 40 C to 80 C Short Circuit Protection I/O-isolation 1500 VDC Input Filter meets EN 55022,class

More information

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters Applications Intermediate Bus architectures Telecommunications equipment LAN/WAN applications Data processing applications Features RoHS lead solder exemption compliant High efficiency up to 94% High power

More information

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

MJWI20 SERIES FEATURES PRODUCT OVERVIEW.  DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series DC/DC 2W, Highest Power Density MINMAX MJWI2 Series MJWI2 SERIES DC/DC CONVERTER 2W, Highest Power Density FEATURES Smallest Encapsulated 2W! Package Size 1. x1. x.4 Ultra-wide 4:1 Input Range Very high

More information

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms. FEATURES Smallest Encapsulated 50W! Package Size 2.0 x 1.0 x 0.4 Wide 2:1 lnput Range Excellent Efficiency up to 92% Over-Temperature Protection I/O-isolation Voltage 1500VDC Remote On/Off Control Shielded

More information

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS FEATURES 2:1 Wide Input Voltage Range: 4.5-12 Input, 9-18 and 18-36 and 36-75 5000Vac Input to Output 2MOPP Isolation Remote On/Off

More information

S24SP series 40W Single Output DC/DC Converter

S24SP series 40W Single Output DC/DC Converter 4W Single Output DC/DC Converter FEATURES Efficiency up to 92.8% Wide input range, 9V-36V Package with Industry Standard Pinout Package Dimension: Without heat sink 5.8 x25.4 x1.2mm (2. x1. x.4 ) With

More information

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05 Doc. EC-0094 FEATURES Industrial Standard Quarter Brick Package Wide Input Range 43-101VDC & 66-1VDC Excellent Efficiency up to 92% I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp.

More information

Application Note TES 1 Series

Application Note TES 1 Series 1W, Miniature SMD, Single & Dual Output DC/DC Converters Features SMD Package with Industry Standard Pinout Small Footprint: 11.0 x 13.7 mm (0.43 x 0.54 ) Single Output Models 11.0 x 16.3 mm (0.43 x 0.64

More information

(typ.) (Range) Load

(typ.) (Range)  Load FEATURES Highest Power Density 1" x 1" x 0.4" Shielded Metal Package Wide 2:1 Input Range Excellent Efficiency up to % Operating Temp. Range - C to + C Optional Heatsink I/O-isolation Voltage 10VDC Remote

More information

DH50 SERIES. DATASHEET Rev. A

DH50 SERIES. DATASHEET Rev. A DATASHEET DH50 SERIES 2:1 Wide Input Voltage Ranges Single Outputs, Efficiency up to 92% 2.0 x 1.0 x 0.4 Encapsulated Shielded Metal Package FEATURES RoHS & UL 94V-0 Compliant 50 Watts Output Power 2:1

More information

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf % Doc. EC-0093 FEATURES Industrial Standard 2"x1" Package Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range -40 C to +88 C

More information

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE FEATURES 4:1 Ultra Wide Input Range Output Current up to 2000 ma Miniature SIP (Single-In-Line) Package, 0.86 0.36

More information

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection Features Regulated Converters 2:1 Wide Voltage Range 1.6kV Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection Description The series / converters are certified

More information

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option

More information

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % FEATURES Industrial Standard Quarter Brick Package Wide Input Range 43-101VDC & 66-1VDC Excellent Efficiency up to 92% I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range - C

More information

2W, Low Cost DIP, Dual Output DC/DC Converters

2W, Low Cost DIP, Dual Output DC/DC Converters 2W, Low Cost DIP, Dual Output DC/DC s Key Features Low Cost 500 Isolation MTBF > 0,000 Hours mv P-P Ripple and Noise Input 12 Output {15 Temperature Performance -25] to +71] Short Circuit Protection UL

More information

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE WATT RAILWAY APPLICATIONS FEATURES No Minimum Load Required 225 Input to Output Basic Insulation Railway Applications 4:1 Wide Input Voltage Range

More information

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G) Features Regulated Converters 2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM-G) Description The series DC/DC

More information

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter Features Regulated Converters Description 2:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield No Minimum Load The series / converters are certified

More information

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd. Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE HAE100-48 S 05 - P TH HS Series Name Input Output Output Ctrl and Through hole Assembly

More information

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE DIP Type: HAE100-48 S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option

More information

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E) Features Regulated Converters 2:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to % Six-Sided Continuous Shield Available as Power Module (RPM30-E) Description The series / converters

More information

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES DATA DATA SHEET SHEET HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 15 WATT RAILWAY APPLICATIONS FEATURES No Minimum Load Required 225 Input to Output Basic Insulation Railway Applications 4:1

More information

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW) Features Regulated Converters Description 4:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW) The series wide

More information

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction Table of Contents Output specification Input specification General specification Environmental specifications EMC characteristic curves Output voltage adjustment Input source impedance Output over current

More information

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd. Railway Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV PART NUMBER STRUCTURE HAE100-48 S 05 W - P TH HS Series Name Input Output Output Input Ctrl and Through hole

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE FED60-48 S 05 W - M3 N HC Series Name Input Output Output Input Operating Temp. Remote

More information

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options Railway Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV PART NUMBER STRUCTURE DIP Type: HAE100-48 S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly

More information

UL Certified RP30-FW

UL Certified RP30-FW Features 4:1 Wide Input Voltage Range 30 Watts Output Power 1.kVDC Isolation UL Certified Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 91% POWERLINE

More information

PG02S Series 2W DC/DC CONVERTER, SIP-Package

PG02S Series 2W DC/DC CONVERTER, SIP-Package PG02S Series 2W DC/DC CONVERTER, SIP-Package FEATURES Efficiency up to 81% SIP Package with Industry Pinout Small Footprint: 21.8 x 9.3 mm (0.86 x 0.37 inch) Wide 2:1 Input Range Operating Temperature

More information

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power FEATURES NO MINIMUM LOAD REQUIRED 1600VDC INPUT TO OUTPUT ISOLATION SCREW TERMINALS

More information

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF Features Switching Regulator Description Efficiency up tpo 94%, no need for heatsinks Pin-out compatible with LM78XX linears Low profile (L/W/H=11.5 x 7.5 x 1.2mm) Wide input range Short circuit protection,

More information

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power FEATURES NO MINIMUM LOAD REQUIRED 1600VDC INPUT TO OUTPUT ISOLATION SCREW

More information

LSS-T/10-W12. Adjustable Output 10 Amp SIP-mount DC/DC Converter. PRODUCT OVERVIEW FEATURES

LSS-T/10-W12.   Adjustable Output 10 Amp SIP-mount DC/DC Converter.   PRODUCT OVERVIEW FEATURES www.murata-ps.com FEATURES Vertical SIP-mount small footprint package Output from 0.6 to 6 Volts up to 51 Watts Ultra-wide 4.5 to 13.8 Vdc input range Outstanding thermal performance and derating Extensive

More information

RCD15W Series PART NUMBER STRUCTURE

RCD15W Series PART NUMBER STRUCTURE DC/DC Railway Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV PART NUMBER STRUCTURE RCD15-48 S 05 W - M3 A HC Series Name Input Output Output Input Operating Temp.

More information

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter FEATURES DOSA Standard Form, Fit & Function Industry standard 1/8th brick footprint 4:1 input voltage range: 9-36 or 18 75Vin ROHS II Directive 2011/65/EU Compliant No minimum load required -40 0 C to

More information

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS Features Description The 4:1 Input Voltage 150 W single HEW Series of DC/DC converters provide precisely regulated dc outputs. The output voltage is fully isolated from the input, allowing the output to

More information

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required Features Regulated Converters Description 4:1 Input Voltage Range 2.25kV Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required The series are SMD open frame

More information

RP40- _FR/ Package (4) CTRL Logic (3)

RP40- _FR/ Package (4) CTRL Logic (3) Features Regulated Converters Description Wide 4:1 Input Voltage Range 1.6kVDC Isolation for 24Vin and 48Vin, 3kVDC Isolation for 1Vin Efficiency up to 92% Six-Sided Continuous Shield UL695-1 AM2 Certified,

More information

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power FEATURES NO MINIMUM LOAD REQUIRED 1600VDC INPUT TO OUTPUT ISOLATION SCREW TERMINALS

More information

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES* CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS * FEATURES 4:1 Wide Input Range (9-36, 43-160Vdc) No Minimum Load Required High Efficiency: Up to 89% Built In EN55011

More information

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power FEATURES NO MINIMUM LOAD REQUIRED 1600VDC INPUT TO OUTPUT ISOLATION SCREW TERMINALS FOR INPUT AND

More information

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE Railway Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV PART NUMBER STRUCTURE RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage

More information

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power FEATURES NO MINIMUM LOAD REQUIRED 1600VDC INPUT TO OUTPUT ISOLATION SCREW TERMINALS FOR INPUT AND OUTPUT

More information

North America Asia-Pacific Europe, Middle East

North America Asia-Pacific Europe, Middle East Bel Power Solutions point-of-load converters are recommended for use with regulated bus converters in an Intermediate Bus Architecture (IBA). The YMS nonisolated dc-dc converters deliver up to A of output

More information

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE FDC10-48 S 05 W - M2 P HC Series Name Input Output Output Input Operating Temp. Remote

More information

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage

More information

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power Small 2.32 x 0.9 x 0.37 Size Constant Frequency High Typical Efficiency of 90% (12Vout) Low Output Noise 18 to 60VDC Input Voltage Range Output Over Voltage Protection Current Limit/Short Circuit Protection

More information