HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

Size: px
Start display at page:

Download "HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer"

Transcription

1 HDI inch Choke Position Indicator User s Manual Rev 2 New 2522 Indicator Gauge Linear Potentiometer w/open Housing 2200 Indicator Gauge Linear Potentiometer

2 TABLE OF CONTENTS HDI inch Indicator Contents 1.0 Systems General Information General Information: Unpacking and Inspection: Precautionary Information: Personnel Qualifications: Systems Description Systems Description: System Components: Choke Position Display Choke Position Potentiometers Cables System Capacities Choke Position Indicators System Options: Remote Display ma Output VDC Output Intrinsic Safety Certifications Installation Control Head and Sensors Cables Mounting Hardware Choke Position Sensor Assembly and Standard Installation General Assembly Choke Position Display Cables Info Choke Positioning Systems Calibration Choke Position System

3 HDI inch Indicator Setting Closed Position Level Setting Open Position Level MAINTENANCE Choke Position System Choke Position Systems Battery Replacement Tools Required for Field Repair or Annual Service: Warranty APPENDIX A APPENDIX B

4 1.0 Systems General Information HDI inch Indicator 1.1 General Information: This manual describes the installation, operation, and maintenance of the HDI 2522 Choke Position Indicator System. Included in this manual are all the necessary procedures to install and maintain this Choke Position Indicator System properly. 1.2 Unpacking and Inspection: Upon receipt of the equipment, the customer should make sure that all items are accounted for on the packing list. If any items are missing, immediately inform the freight forwarder. Inspect all items for damage. If any items are damaged immediately inform the freight forwarder and HDI Instruments. 1.3 Precautionary Information: The customer should verify that all directions on the packages are followed during unpacking and handling. Caution: If the return spring is preinstalled on the linear potentiometer shaft (if purchased), the user should use caution to prevent damage to the potentiometer shaft. The fully compressed spring has enough force to shear the holding clip and launch the potentiometer stem from the housing, destroying the unit. There is enough force when compressed that the linear shaft can be pulled from the internal body. If damaged, the linear potentiometer must be replaced since this is an oil-filled sealed unit and cannot be repaired. 1.4 Personnel Qualifications: This equipment requires minimal experience to handle, install and maintain. HDI offers technical training on our premises at customer request. 4

5 2.0 Systems Description HDI inch Indicator 2.1 Systems Description: The HDI 2522 System is an Electronic Choke Position Indicator System. The system consists of three primary components as detailed in Section 2.2. An electronic potentiometer is housed inside a stainless steel housing and is adjustable to ensure the sensor is located properly to detect travel movement of the choke. HDI has several different housing configurations that have been designed to adapt to the most commonly used chokes: Shaffer/NOV, Cameron, Swaco, Control Flow, Cortec. HDI can assist the customer in the design for a specific application. The electronic bar graph display indicates choke position from closed to open, where 100% if fully Open. 2.2 System Components: Choke Position Display The display is a liquid crystal display (LCD), which includes a four digit numerical display (for accuracy) and a bar-graph representation (for trend) Choke Position Potentiometers As noted above, HDI has designed several different sensor housings to be compatible to various choke styles to reduce onsite customization and to simplify installation after removing the existing pneumatic sensors. General dimensional drawings or photos are available upon request to ensure compatibility Cables All interconnecting cables supplied by HDI or can be adapted to use junction box for open termination. Wiring details are provided later in this manual. 5

6 2.3 System Capacities HDI inch Indicator Choke Position Indicators HDI s Choke Position Indicators will display from 0 to 100 percent and will be respective to the customer s choke body orientation for an open or close position. By default, the display is configured to represent the open state of the choke and 100% represents fully open. 2.4 System Options: HDI offers the following options to the customer at an additional cost Remote Display Remote displays may be provided to allow secondary indicators at an alternate location at the customer s request ma Output HDI offers as an option, a signal current loop providing a 4-20 ma remote output that may be used for chart recorder inputs, data logging or to PLC systems for remote graphical representation. This is a factory installed option and does not require calibration. The customer is required to provide a 24 Vdc current loop and related barrier for zone installation VDC Output HDI offers as an option, a signal providing a 0-1 Vdc remote output that may be used for chart recorder inputs and / or data logging. This is a factory installed option and does not require calibration Intrinsic Safety Certifications The HDI 2522 was designed based on HDI s experience and current products to meet safety concerns to be intrinsically safe rated; however, this product does not have any current IS Certificates. IECEX and IS certificates are pending at this time. 6

7 3.0 Installation HDI inch Indicator 3.1 Control Head and Sensors The control head and sensors are to be mounted by the customer at the locations deemed most suitable for such equipment. The system potentiometer assembly comes from the factory as a complete assembly and only requires mounting of the sensor housing using standard practices for such installations. 3.2 Cables All cable lengths from the control panel to the sensors shall be supplied by the customer. This is so that HDI can provide prefabricated cables for a quick and simple plug and play installation. HDI s systems may differ from other similar position indicators on the market. HDI s cables will have a male (pin) and female (socket) connectors that easily allow cables to be added to extend cable lengths. 3.2 Mounting Hardware Sensor integration to the choke bodies will generally use the existing bolts from the pneumatic sensors once removed. The HDI sensor assembly will be complete with all necessary hardware or adaptive stems as required. For example, both Swaco Rotary and Cameron s M3D Sensors will include a choke specific adaptive stem. Custom fit ups are available as options by HDI. 3.3 Choke Position Sensor Assembly and Standard Installation General Assembly The Choke Position Potentiometer and mounting brackets are provided to replace an existing pneumatic regulator choke position system presently in use. This assembly is designed to mount in the original choke position enclosure utilizing the existing hole patterns and mounting hardware. The customer should remove the existing choke position assembly and install the new stainless steel housing and potentiometer assembly with mounting brackets with the existing mounting hardware. 7

8 Bracket Style Linear Housing: HDI inch Indicator Using a 1 ¾ wrench, loosen the potentiometer nuts on both sides of the bracket to allow the customer to adjust the sensor depth. With the choke body in the fully closed position, adjust the cylinder potentiometer assembly to allow for a 1/8 to 1/4" compression of the shaft. Hand tighten the potentiometer nuts to secure the potentiometer from movement. Slowly function the choke while observing the potentiometer to prevent it from bottoming out inside the cylinder housing. Once confirmed that there are no issues, tighten the nuts and then proceed to calibration Standard Linear Potentiometer Housing Loosen the potentiometer brass mounting brackets to allow for adjustment. With the choke body in the fully closed position, adjust the cylinder potentiometer assembly to allow 1/8 to 1/4" compression of the shaft into the potentiometer housing and tighten the bolts on the brass mounting brackets. Observe the choke bodies and sensor while opening the choke to make sure the potentiometer does not bottom out inside the cylinder housing. Rotary Potentiometer HDI provides an adaptive shaft (for a Swaco application) that must be threaded into the existing choke shaft via the adjustment stud. The customer will note on the face of the rotary potentiometer a Dead Spot marked in red. The remaining section is the working zone of the potentiometer. The potentiometer is left loose at this point for a future adjustment to the HDI provided bolt which is threaded into the choke stem. Orientation to clockwise and counter-clockwise operation is critical to avoid crossing into the dead span of the potentiometer, which will cause a spike or erratic reading on the LCD. Once the orientation of the rotary potentiometer matches clockwise and Counterclock-wise orientation, gently tighten the set screw on the brass mounting block to secure the potentiometer assembly from rotating during operation. An instructional video of this installation is available on the HDI website. 8

9 HDI inch Indicator Choke Position Display The LCD gauge is designed to be a direct drop in replacement for all similar 4-inch round position indicators to include the bolt hole pattern to secure the gauge. The only noticeable difference is that the HDI unit may require one to two inches of additional clearance once installed into the control panel. In the event there is any interference with hydraulic plumbing, the interconnect cable can be configured with a 90 degree elbow to offset any cable clearance. Remove the lock nuts, drop the gauge in the appropriate hole and replace the lock nuts and secure the gauge. Do not overtighten Cables The system comes complete with cable and connectors made to the customer s specifications. Simply route the cable from the transducer to the gauge, connect the cables to the transducer and gauge, and tighten the collars. Note the pin terminator side attaches to the LCD display. 9

10 4.0 Info HDI inch Indicator 4.1 Choke Positioning Systems The LCD (Control head) has a 3.6 V E606 (replaceable) battery pack that supplies power to the LCD via the power cable. The Control Head then supplies the excitation to the Sensor and measures the ohm resistances generated during the extension or compression of the potentiometer. The information is then converted to be displayed on the LCD as a numeric digit readout with a corresponding bar graph. The choke position indicator does not require any warm up period. Note: HDI sensors are typically 2 or 5K potentiometers, but are compatible with client specific potentiometers up to a 25K unit. Turning the system off when not in use will greatly extend battery life. 5.0 Calibration 5.1 Choke Position System This device is field calibrated directly from the front membrane panel. Calibration is required for the first time install and anytime the main processor board or the potentiometer sensor is field repaired or replaced. See table below for descriptions of the button functions. Mode Select Button UP ARROW 100% Calibration Select Button DOWN ARROW 0% Calibration Select Button Enter Select Button Selects calibration. Allows for calibration at open choke position. Allows for calibration at closed choke position. Enters Mode and Calibration Selections Power ON/OFF Power on/off switch. 10

11 HDI inch Indicator Power ON: Press the Power button once (Unit performs self-test, all display segments turn on) Power OFF: Press the Power button once Setting Closed Position Level 1. Once the installation is complete the choke should be closed completely. 2. Apply power to device by pressing the POWER button. 3. Choke Position Indicator will perform a short self-test during which time all LCD segments will be active. 4. After the self-test is complete, the display will be in the run/active mode. (RUN indicator will appear at the lower left side of the LCD display). 5. Check to verify the Choke is completely CLOSED, press the MODE button. (RUN indicator will turn OFF). 6. Press the Down button. (Unit is now in calibration mode) 7. The down arrow and a four digit number will appear at the top of the LCD display. 8. Press the Enter button. (This function causes the gauge to accept (store) the low / closed set point position, unit returns to RUN mode). 9. The closed position level is now set, and the three digit display should read Setting Open Position Level 1. Function the Choke to the fully Open position. 2. Once in the Open position, press MODE button. (RUN indicator will turn OFF) 3. Press UP button. (Now in calibration mode) 4. The up arrow and a four digit number will appear at the top of the LCD display. 5. Press the Enter button. (This function causes the gauge to accept the high / open set point position, unit returns to RUN mode). 6. The Open position level is now set, and the three digit display should read

12 HDI inch Indicator 7. The unit is now fully calibrated. 6.0 MAINTENANCE 6.1 Choke Position System Generally, this system should only require calibration every 2 years, when the power pack is replaced, or if there are any change in system wiring or if a repair is completed. It is suggested that a visual inspection be performed from time to time, perhaps every 6 months to ensure the stem has not been bent. The sensor box when mounted has some play in the mounting pattern allowing alignment of the unit to avoid putting any bind on the stem while in operation. This may need some adjustment. The customer should also periodically check the cables for any visual damage or cuts that will allow water or moisture into the cable causing interference and erroneous results. 6.2 Choke Position Systems Battery Replacement Remove the cable from the back side of the case, along with the 3/8 locknuts that are securing the gauge to the panel. Using a 7/64 Allen wrench, remove the machine screws from the front of the unit to gain access to the electronics. Remove the front trim ring and the membrane panel with the gasket. Disconnect the battery lead from the main processor board. Remove 3 of the 5 PCB screws. See photo. 12

13 HDI inch Indicator Remove the battery retainer plate then proceed to remove the battery, desiccant pack, corrosion inhibitor and humidity indicator. Insert the new battery in the case. Replace the desiccant pack, corrosion inhibitor and humidity indicator and install the retainer clip. It is recommended that the system be tested at this time to ensure everything is working before closing up the gauge. Connect the battery to the main processor board and connect the interconnect cable to the gauge and have the choke functioned to calibrate the unit per Section 5. If the system operates properly, finish assembling the unit in the reverse order. The power pack is covered under a one year warranty from date of shipment and will generally last months when continuously running. When not in use, it is suggested to power off the unit to extend battery life. 6.3 Tools Required for Field Repair or Annual Service: 1. Screwdriver, Phillips (small) 2. Allen wrench, 7/64 3. Socket Wrench, 3/8 7.0 Warranty HDI Instruments, LLC. (HDI) warrants this product for a period of one year from the date of shipment. HDI s manufactured products to the extent that HDI will replace those parts having defects in material or workmanship when used for the purpose or specification HDI recommends for Normal Oilfield Usage. HDI shall not honor the Warranty if any evidence of tampering, misuse or intrusion is indicated except by an HDI authorized technician or agent. HDI will replace or repair, as it deems necessary, any products covered by this warranty, after HDI's examination discloses to its satisfaction, that in fact the products are defective and an adjustment is required. If an adjustment is required, the amount of the adjustment is the net sales price of the defective product. No allowances shall be made for labor or expenses of repairing defective products or damage resulting from same. All products accepted under the provisions of 13

14 HDI inch Indicator this warranty shall be shipped prepaid to HDI and returned to the customer prepaid by HDI. This is to include all applicable custom clearance fees, etc. for inbound international shipments. All products not accepted under the provisions of this warranty shall be shipped prepaid to HDI and returned freight collect. HDI shall not be responsible for repair or replacement of products, resulting from improper handling, storage, installation, misuse, negligence, or use in a manner contrary to the recommendations of HDI. HDI warrants only the products that it sells of Other Manufacturers to the extent of their warranties. All warranty claims shall be made in writing to the nearest HDI office or authorized factory representative. HDI makes no other warranty of any kind, expressed or implied, and all implied warranties of merchantability or fitness for a particular purpose which exceed HDI's afore-stated obligation are hereby disclaimed by HDI and excluded from this warranty. This Warranty is non transferable and HDI shall not be liable for any damage, injury, loss to property or persons resulting from the use of any HDI's products or equipment whether such damage, injury or loss results from, or is caused by: manner of use, defects in materials or workmanship or otherwise. Only exception: when the purchase is made from a known supply house, the end user should be identified. 14

15 APPENDIX A HDI inch Indicator WIRING INFORMATION: Sensor Wiring: Linear Potentiometer Device Markings Connector Processor Board Color Code 1 A P BLACK 2 B S WHITE 3 C G GREEN Rotary Potentiometer w/ stem facing user Connector Processor Board Color Code Left A P BLACK Middle B S WHITE Right C G GREEN 4-20mA Output Connector A B C D E Function Code Not Used Not Used Grnd Color Black White Red Green Shield 0-1 Vdc Output 5-pin Connector A B C D E Function Code N/A N/A Signal + Signal - Grnd Color Black White Red Green Shield 15

16 HDI inch Indicator APPENDIX B 16

17 HDI inch Indicator 17

18 HDI inch Indicator 18

19 HDI inch Indicator Client Maintenance Notes 19

20 ISO 9001:2008 Office Phone After Hours Support, Primary: After Hours Support, Secondary: Directors Row Houston, TX 77092

PSC-301 Pump Stroke Counter

PSC-301 Pump Stroke Counter PSC-301 Pump Stroke Counter 3 PUMP MODEL Operations and Maintenance Manual Rev 1000 WG Industries, Inc. 2825 Creek Bend Drive Friendswood, TX 77546 Ph 713 416 1585 Fax 281 404 9054 Toll Free 800 440 1153

More information

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com

More information

HDI 2000B/P Panel & All-in-One Gauge User s Manual Rev 0

HDI 2000B/P Panel & All-in-One Gauge User s Manual Rev 0 HDI 2000B/P Panel & All-in-One Gauge User s Manual Rev 0 2000B Panel Gauge 2000P All-in-One TABLE OF CONTENTS HDI 2000B/P Pressure Gauges Section 1 Introduction.4 1.A General Information 1.B Unpacking

More information

LU23, LU28 & LU29 Series Quick Start

LU23, LU28 & LU29 Series Quick Start Ultrasonic Liquid Level Transmitter LU23, LU28 & LU29 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f

More information

Universal Bevel Drives Service Manual

Universal Bevel Drives Service Manual Engineering Service Bulletin #SB241202 Universal Bevel Drives Service Manual Cautions Following are some general cautions. All personnel shall use safe and sound practices and take all necessary precautionary

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Single-Stud/Dual-Stud Short-Throw Projector Wall Mount Model: EST100/EST200 NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700

More information

XP88 & XP89 Series Quick Start

XP88 & XP89 Series Quick Start Ultrasonic Liquid Level Transmitter XP88 & XP89 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507

More information

LU27 Series Quick Start

LU27 Series Quick Start Ultrasonic Liquid Level Transmitter LU27 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Short Throw Projector Wall Mount Model: NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700 Fax: 1-800-832-4888 Other

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:

More information

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MPV1 series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional

More information

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MPV1 series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MM series proportional control valves utilize ProportionAir's unique closed loop control technology for superior control

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Current Transducer January 2012 Case Backup Washer Connection Stem O Ring Stem Seal Fig. 1 - Current Tranducer UNPACKING Page 2 SPECIFICATIONS Page 2 ACQUAINT YOURSELF WITH THE PARTS

More information

A S S E M B L Y I N S T R U C T I O N S

A S S E M B L Y I N S T R U C T I O N S A S S E M B L Y I N S T R U C T I O N S Please Do Not Return This Product to the Store! Contact Escalade Sports customer service department at: Phone: 1-888-USA-GOAL Toll-Free! Fax: 1-866-873-3536 Toll-Free!

More information

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual SEC SEC America, LLC Model 7048 DC-DC Converter Rev 1 Owner's Manual July 19, 2016 TABLE OF CONTENTS page I Introduction 1 II Installation 1 2.1 Mounting 1 2.2 Connections 1 2.3 Methods of Converter Activation

More information

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL Model 7200 Transducers GP:50 2770 Long Road, Grand Island, NY 14072 Tel: 716-773-9300 Fax: 716-773-5019 Email: sales@gp50.com Website: http://www.gp50.com

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING KURYAKYN! Protect yourself and others from possible injury and property damage or loss. Pay close attention to all instructions, warnings, cautions, and notices regarding the installation,

More information

Effective June 2016 New Issue

Effective June 2016 New Issue Voltage Regulators MN225035EN Effective June 2016 New Issue COOPER POWER SERIES QD8 Quik-Drive Tap-Changer Switch Assembly Kit 5740785B13 and Switch Neutral Stationary Assembly Kit 5791646A48 Installation

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Please retain for future usage Level Transmitters for Magnetic Level Gauges BT / BTX / BTXI 120872 / Rev. 02-26.02.2016 INTRODUCTION KSR Kuebler level transmitters

More information

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter EchoPod Ultrasonic Liquid Level Transmitter UG06 & UG12 Series Quick Start 2017 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015

More information

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN Fusing Equipment MN132031EN Effective November 2016 Supersedes July 2008 (S240-92-1) COOPER POWER Edison Modular Fuse (EMF) Installation Instructions SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

POWER CELL FOR DYNA WITH CLEAN CHROME COVER 562

POWER CELL FOR DYNA WITH CLEAN CHROME COVER 562 POWER CELL FOR DYNA WITH CLEAN CHROME COVER 562 THANK YOU FOR CHOOSING CRUSHER! PROTECT YOURSELF AND OTHERS FROM POTENTIAL INJURY AND PROPERTY DAMAGE OR LOSS. PAY CLOSE ATTENTION TO ALL INSTRUCTIONS, WARNINGS,

More information

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS SPECIFICATIONS 1 PRINCIPLE OF OPERATION 1 INSTALLATION 2 Choosing a Sampling Location 2 Mounting the Enclosure 2 Remote Alarm

More information

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA EchoPod Ultrasonic Level Switch, Controller & Transmitter DL10, DL14, DL24, DS14 & DX10 Series Quick Start DL14-00 Shown 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt

More information

SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual

SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual SEC SEC America, LLC Model 680 CE, DC-DC Converter Owner's Manual April 15, 2010 TABLE OF CONTENTS page I Introduction 1 II Installation 1 2.1 Mounting 1 2.2 Connections 1 2.3 Methods of Converter Activation

More information

LNW-5. Installation... 2 Lift Truck Conditions Indicator Installation Hose Installation

LNW-5. Installation... 2 Lift Truck Conditions Indicator Installation Hose Installation Table Of Contents Important Notice... ii Caution... iii DC Power Filters... iv Introduction & Description... 1 Principle of Operation Pressure Transducer Digital Indication Housing Power Requirements Installation...

More information

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

EchoPod. Technical Support. Model: DL14-(XX) Quick Start Technical Support For complete product documentation, video training, and technical support, go to www.flowline.com. For phone support, call 562-598-3015 from 8am to 5pm PST, Mon - Fri. (Please make sure

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet!

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet! US Patent 0540, 400 Other Patents Pending Read this manual completely before assembling and riding our 500 Always wear a Helmet! Priority Electric Transportation, LLC. 1007 West College Ave. #293 Santa

More information

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Single Lever Vessel Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories

More information

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review

More information

INSTALLATION MANUAL FOR PILOT WORKSTATION

INSTALLATION MANUAL FOR PILOT WORKSTATION INSTALLATION MANUAL FOR PILOT WORKSTATION Weight Capacity: 5-25 lbs. Monitor Weight: 5-20 lbs. 6011180 Rev. B Contents Tools Required / Supplied Part Kits / Warnings/Disclaimer...2 Possible Base Mounting

More information

Installation Instructions

Installation Instructions Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers

More information

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,

More information

Phase Sequence Tester

Phase Sequence Tester User's Guide Phase Sequence Tester Model 8000 Introduction Congratulations on your purchase of the Extech Model 0800 Phase Sequence Tester. This handheld instrument detects the phase sequence of three-phase

More information

Rotary Cutter Drives Service Manual

Rotary Cutter Drives Service Manual Engineering Service Bulletin #SB241227 Rotary Cutter Drives Service Manual Cautions Following are some general cautions. All personnel shall use safe and sound practices and take all necessary precautionary

More information

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS B133-05, Page 1 952-361-3026 PROCESS CONTROL SYSTEMS, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS Introduction The

More information

RVF4109CH. Features. Dimensions RUVATI. Model: RVF4109CH Single Handle Bathroom Faucet

RVF4109CH. Features. Dimensions RUVATI. Model: RVF4109CH Single Handle Bathroom Faucet Single Handle Bathroom Faucet Features Chrome Finish Ceramic valve cartridge Solid brass construction Single handle lever for easy use Includes hot and cold water supply lines with 1/2 IPS connections

More information

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual RoughDeck TM FXB Flexure Base Floor Scale Installation/Operation Manual SM 32958 13 Contents 1. Introduction... 1 1.1 Scale Components... 1 1.2 Operating Requirements... 2 1.3 How Flexure Levers Work...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thank you for purchasing ROXTERTM Hitch Mounted Mud Flaps. Agri-Cover, Inc. proudly manufactured these mud flaps using superior quality materials and workmanship. With proper

More information

AXD 530 MicroManometer

AXD 530 MicroManometer OWNER S MANUAL AXD 530 MicroManometer A TSI Company Table of Contents Features 2 Using the AXD530 Safely 3 Getting Started 4 Installing Batteries 4 Preparing the Instrument 4 Attaching the Optional Pitot-Static

More information

Artesian2 Owners Manual

Artesian2 Owners Manual Artesian2 Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

Artesian Owners Manual

Artesian Owners Manual Artesian Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

BEAMER Tilt Beam Sensor

BEAMER Tilt Beam Sensor User s Manual BEAMER Tilt Beam Sensor Serial No. 140 Chestnut Street San Francisco, CA 94111 Phone: 415 364 3200 Fax: 415 861 1448 www.geomechanics.com CAUTION: Never measure the sensor inside your Beamer

More information

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS Thank you for purchasing ROCKSTARTM Splash Guard Mud Flaps. Agri-Cover, Inc. proudly manufactured these mud flaps using superior quality materials

More information

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System Instruction Sheet SRSR SERIES Rotating Sliding Rail System THANK YOU Thank you for purchasing the SRSR Series Rotating Sliding Rail System. Please read these instructions thoroughly before assembling this

More information

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual Warranty, Service and Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: FLOWLINE Inc. 10500 Humbolt Street Los Alamitos, CA 90720

More information

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator Joyce/Dayton Corp. Operation and Maintenance Manual for Multipurpose Actuators 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator The recommendations in this manual for installation, operation and maintenance

More information

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD 2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD Thank you for your purchase of this Hotchkis Performance product. Please call us at (800) 4NO-ROLL if you have any questions regarding this product.

More information

COMPRESSED AIR LOADER MODEL: AL-1

COMPRESSED AIR LOADER MODEL: AL-1 COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection

More information

MOVE ON TO THE REAR BAR INSTALLATION

MOVE ON TO THE REAR BAR INSTALLATION 22410 STREET SWAY BAR SET 2001-UP LEXUS IS300 Thank you for your purchase from our line of Lexus parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service or installation

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

DeZURIK KUL KNIFE GATE VALVES

DeZURIK KUL KNIFE GATE VALVES KUL KNIFE GATE VALVES Instruction D11025 September 2013 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KUL knife

More information

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment MSI150X SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM User Guide Quality Industrial Weighing and Force Measurement Equipment Measurement Systems International Page 2 MSI-150X Sky-Weigh User Guide

More information

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY Issue 5 24/48 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-4124 and VP-4124-E, 24/48 Volt Power Supplies.

More information

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate! INSTALLATION / OWNER'S MANUAL Single Handle Kitchen Faucet Model # LK500 Important! You choose the flow rate! This faucet ships with an eco-friendly.5gpm flow regulator installed. If you desire higher

More information

SETRA Operating Instructions Series DPT 230 Pressure Transducers

SETRA Operating Instructions Series DPT 230 Pressure Transducers SETRA Operating Instructions Series DPT 230 Pressure Transducers GENERAL INFORMATION Your Setra Pressure Transducer has been carefully tested and calibrated before shipment. Specific performance information

More information

AD-7 THERMAL INDICATING AMMETER

AD-7 THERMAL INDICATING AMMETER AD-7 THERMAL INDICATING AMMETER a nd ACCESSORIES Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7.

More information

2000SR. Installation Instructions May Donovan Enterprises 3353 S.E. Gran Park Way Stuart, Florida

2000SR. Installation Instructions May Donovan Enterprises 3353 S.E. Gran Park Way Stuart, Florida 311499-Donovan 4/28/04 11:22 PM Page 1 Installation Instructions May 2003 Donovan Enterprises 3353 S.E. Gran Park Way Stuart, Florida 34997 1-800-327-8287 Visit our web site at: www.donovan-ent.com 311499-Donovan

More information

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Instruction Sheet DWRSR-ZL. Zero Clearance Latch Instruction Sheet DWRSR-ZL Zero Clearance Latch US Patent 7,188,570 B2 THANK YOU Thank you for purchasing the DWRSR-ZL Zero Clearance Latch. Please read these instructions thoroughly before installing

More information

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

DODGE CUMMINS Arctic-Heat Grid Relocation Kit Installation Manual P/N 07509-350-GRK 2007.5-09 DODGE CUMMINS Arctic-Heat Grid Relocation Kit Installation Instructions P/N 07509-350-GRK GDP Arctic-Heat Grid Heater Installation PLEASE READ ALL INSTRUCTIONS

More information

EchoPod. UG01 & UG03 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Switch, Controller & Transmitter

EchoPod. UG01 & UG03 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Switch, Controller & Transmitter EchoPod Ultrasonic Liquid Level Switch, Controller & Transmitter UG01 & UG03 Series Quick Start 2017 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

INSTALLATION. Note: Not all of the included parts will be used during this installation. -cont.-

INSTALLATION. Note: Not all of the included parts will be used during this installation. -cont.- Driving Lights for Road Glide 5007 Fits: 98-up Road Glide PartS Included 1 Right Light Assembly 1 Left Light Assembly 1 Right Mounting Bracket 1 Left Mounting Bracket 1 Hardware Kit Including: 2 Narrow

More information

PIPE FITTING ACCESSORIES EFFECTIVE FEBRUARY 5, 2018

PIPE FITTING ACCESSORIES EFFECTIVE FEBRUARY 5, 2018 CANADIAN IMPORT PRICE LIST PIPE FITTING EFFECTIVE FEBRUARY 5, 2018 version: EFFECTIVE: FEBRUARY 5, 2018 (SUPERSEDES ALL PREVIOUS PRICING) CORONA CALL CENTER (U.S.) Toll Free: (877) 701-7827 Fax: (951)

More information

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL INSTRUCTION MANUAL IV STANDS Assembly, Usage and Maintenance Read and understand all of the instructions and safety information in this manual before operating this product. MAN-045 REV A 2018 MAC Medical,

More information

CRUSHER MAVERICK 2 INTO 2, BLACK 566

CRUSHER MAVERICK 2 INTO 2, BLACK 566 CRUSHER MAVERICK 2 INTO 2, BLACK 566 THANK YOU FOR CHOOSING CRUSHER! PROTECT YOURSELF AND OTHERS FROM POTENTIAL INJURY AND PROPERTY DAMAGE OR LOSS. PAY CLOSE ATTENTION TO ALL INSTRUCTIONS, WARNINGS, CAUTIONS,

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

LA19 Series Ricochet Battery Powered Level Transmitter and Display

LA19 Series Ricochet Battery Powered Level Transmitter and Display Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If

More information

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE COMPRESSOR 1 EMERGENCY SHUTDOWN OFF POWER ON COMP LOADED COM PRESSOR OPERATING HOURS SYSTEM PRESSURE COMPRESSOR 2 EMERGENCY SHUTDOWN OFF POWER ON COMP LOADED COM PRESSOR OPERATING HOURS LEAD/LAG CONTROL

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS 2019-ON RAM 1500 INSTALLATION INSTRUCTIONS Thank you for purchasing ROCKSTARTM Splash Guard Mud Flaps. Agri-Cover, Inc. proudly manufactured these mud flaps using superior quality materials and workmanship.

More information

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER Sanitary Mixing and Blending Equipment 2 Fristam Pumps DESCRIPTION This manual contains installation, operation, assembly, disassembly

More information

INSTALLATION. Note: Not all parts will be used in the installation of this product. -cont.-

INSTALLATION. Note: Not all parts will be used in the installation of this product. -cont.- 5005 Fits: 06-up FLHX, 04-up Screamin Eagle Ultra Classic Electra Glide & Screamin Eagle Electra Glide Classic, '97-up FLHT, FLHTC, FLHTCU, FLHR PartS Included 1 Right Driving Light Assembly 1 Left Driving

More information

Easytork Solenoid Valve IOM

Easytork Solenoid Valve IOM Easytork Solenoid Valve IOM General This installation document is to be read in conjunction with the Easytork Vane Actuator IOM. Description The Easytork Solenoid Valve ( ESV ) series is intended for the

More information

Spring Mount SAB30403 (Sold Separately)

Spring Mount SAB30403 (Sold Separately) 1. System Components Spring Mount SAB30403 (Sold Separately) Cable (Sold Separately) 1. System Components: Blue Black To Customer's Control Sensing Area Sensor Power On LED Load On LED Monitor Monitor

More information

Installation Instructions

Installation Instructions Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers

More information

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS SPORT COIL SPRINGS 2004+ Scion xa & xb Part #19412 Thank you for your purchase from our new line of Scion xa / xb parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service

More information

5000 Series Covering Systems Installation Instructions

5000 Series Covering Systems Installation Instructions ENTERPRISES Donovan R a I s e T h e S t a n d a r d 5000 Series Covering Systems Installation Instructions The following hardware is universal to all kits: Bent arm extension (L) 1 905 Hose clamp 1 ½ 4

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Ultra Short-Throw Projector Wall Mount Model: UNIU NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700 Fax: 1-800-832-4888 Other

More information

Smile 11 RA/-B Smile 12 RF/-G Reset button

Smile 11 RA/-B Smile 12 RF/-G Reset button Original Instructions Smile 11 RA/-B Smile 12 RF/-G Reset button ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this User Manual Please read

More information

FOR SIT-STAND WORKSTATION

FOR SIT-STAND WORKSTATION INSTALLATION MANUAL FOR SIT-STAND WORKSTATION Weight Capacity: 6.5-24.5 lbs. 6017180 Rev. B Contents Tools Required / Supplied Part Kits / Warnings/Disclaimers...2 Base Installation Clamp Mount Base Location...3

More information

Installation Instructions & Warranty

Installation Instructions & Warranty Installation Instructions & Warranty Commercial Style Pullout Spray Kitchen Faucet w/ Pot Filler Commercial Style Pullout Spray Kitchen Faucet w/ Pot Filler Features Stainless steel finish Kerox Ceramic

More information

Assembly, Use and Care

Assembly, Use and Care Model 2000 SR Professional Rotary Spreader Assembly, Use and Care Thank You! You have purchased the highest quality professional broadcast spreader available on the market today. The Model 2000 SR is the

More information

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual 25500181 Rev. A0 415 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification Systems

More information

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS

More information

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions Voltage Regulators MN225025EN Effective March 2016 Supersedes S225-50-48 November 2008 COOPER POWER SERIES QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit 5791646A26 installation

More information

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE VOLLEYBALL SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE REV083115 Sports Attack, LLC. 800-717-4251 sportsattack.com WARRANTY STATEMENT

More information

HOW TO INSTALL YOUR BOV

HOW TO INSTALL YOUR BOV Product Name: Product Description: Product Number: BMW Kompact BOV Kit Model specific BOV Kit TS-0203-1050/TS-0203-1250 ------------------------------------------------------------------------------------------------------------------------

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Service/Installation Manual Full Wall Slide Systems

Service/Installation Manual Full Wall Slide Systems Service/Installation Manual Full Wall Slide Systems 7 East 7th Street Mishawaka, IN 65 888-9-57 Fax 57-56-67 www.powergearus.com 8-S079 Rev Page CONTENTS Page Major Components Full Wall Slide System Operation

More information

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source. OWNER S MANUAL RK2 Systems Pro Pump Energy-Efficient, Self Priming Centrifugal Pumps Important Safety Instructions Please read all instructions completely before you install or operate your new pump. Save

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

OPERATOR S MANUAL with Parts List & Warranty. For Model 100SP Topdresser

OPERATOR S MANUAL with Parts List & Warranty. For Model 100SP Topdresser OPERATOR S MANUAL with Parts List & Warranty For Model 100SP Topdresser July 30, 2009 Model 100SP Topdresser LIMITED WARRANTY Earth & Turf Products, LLC warrants to the original Purchaser, all Earth &

More information

MLS DEFENDER SOCCER TABLE ASSEMBLY INSTRUCTIONS

MLS DEFENDER SOCCER TABLE ASSEMBLY INSTRUCTIONS MLS DEFENDER SOCCER TABLE ASSEMBLY INSTRUCTIONS NGD1032 THANK YOU! Thank you for your purchase of this Harvil product. We work around the clock and around the globe to ensure that Harvil products maintain

More information

Air Lift. Kit PERFORMANCE INSTALLATION GUIDE Scion xb

Air Lift. Kit PERFORMANCE INSTALLATION GUIDE Scion xb Air Lift PERFORMANCE Kit 75699 2008- Scion xb MN-689 (041108) ECR 7072 INSTALLATION GUIDE For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information